Volumn 98, Issue 20, 2011, Pages

Power efficiency estimation of silicon nanocrystals based light emitting devices in alternating current regime

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE MATERIAL; ALTERNATING CURRENT; DIRECT CURRENT; ELECTRICAL POWER; EXPERIMENTAL METHODS; HIGH FREQUENCY; HIGHER FREQUENCIES; IMPEDANCE CHARACTERISTICS; IMPEDANCE SPECTROSCOPY; LIGHT EMITTING DEVICES; MICROSCOPIC STRUCTURES; POWER EFFICIENCY; POWER EFFICIENCY ESTIMATION; SILICON NANOCRYSTALS; THRESHOLD FREQUENCY;

EID: 79957562589     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.3592566     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 13144305112 scopus 로고    scopus 로고
    • Field-effect electroluminescence in silicon nanocrystals
    • DOI 10.1038/nmat1307
    • R. J. Walters, G. I. Bournianoff, and H. A. Atwater, Nature Mater. 1476-1122 4, 143 (2005). 10.1038/nmat1307 (Pubitemid 40178713)
    • (2005) Nature Materials , vol.4 , Issue.2 , pp. 143-146
    • Walters, R.J.1    Bourianoff, G.I.2    Atwater, H.A.3
  • 2
    • 42449136235 scopus 로고    scopus 로고
    • Auger quenching-based modulation of electroluminescence from ion-implanted silicon nanocrystals
    • DOI 10.1088/0957-4484/19/20/205201, PII S0957448408714673
    • J. Carreras, C. Bonafos, J. Montserrat, C. Dominguez, J. Arbiol, and B. Garrido, Nanotechnology 0957-4484 19, 205201 (2008). 10.1088/0957-4484/19/20/ 205201 (Pubitemid 351570963)
    • (2008) Nanotechnology , vol.19 , Issue.20 , pp. 205201
    • Carreras, J.1    Bonafos, C.2    Montserrat, J.3    Dominguez, C.4    Arbiol, J.5    Garrido, B.6
  • 6
    • 79957554046 scopus 로고    scopus 로고
    • In this work, the current was measured in an impedance bridge configuration. The bridge has to be balanced at each point of the frequency scan due to the nonlinear properties of the device under test. We used an LCR meter to analyze the impedance which automatically balances the bridge and yields higher accuracy than manual balancing. The used LCR meter was limited to frequency lower than 1 MHz
    • In this work, the current was measured in an impedance bridge configuration. The bridge has to be balanced at each point of the frequency scan due to the nonlinear properties of the device under test. We used an LCR meter to analyze the impedance which automatically balances the bridge and yields higher accuracy than manual balancing. The used LCR meter was limited to frequency lower than 1 MHz.
  • 10
    • 30744458365 scopus 로고    scopus 로고
    • CPE analysis by local electrochemical impedance spectroscopy
    • DOI 10.1016/j.electacta.2005.02.128, PII S0013468605008285, Electrochemical Impedance Spectroscopy Selection of Papers from the 6th International Symposium (EIS 2004)
    • J. -B. Jorcin, M. E. Orazem, N. Ṕb̀re, and B. Tribollet, Electrochim. Acta 0013-4686 51, 1473 (2006). 10.1016/j.electacta.2005.02.128 (Pubitemid 43098823)
    • (2006) Electrochimica Acta , vol.51 , Issue.8-9 , pp. 1473-1479
    • Jorcin, J.-B.1    Orazem, M.E.2    Pebere, N.3    Tribollet, B.4
  • 11
    • 0034215231 scopus 로고    scopus 로고
    • 0034-6861, 10.1103/RevModPhys.72.873
    • J. C. Dyre and T. B. Schroder, Rev. Mod. Phys. 0034-6861 72, 873 (2000). 10.1103/RevModPhys.72.873
    • (2000) Rev. Mod. Phys. , vol.72 , pp. 873
    • Dyre, J.C.1    Schroder, T.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.