-
2
-
-
12444336492
-
Optimizing outcomes with maximal surgical resection of malignant gliomas
-
SJ Hentschel R Sawaya 2003 Optimizing outcomes with maximal surgical resection of malignant gliomas Cancer Control 10 109 114 12712005 (Pubitemid 36437817)
-
(2003)
Cancer Control
, vol.10
, Issue.2
, pp. 109-114
-
-
Hentschel, S.J.1
Sawaya, R.2
-
3
-
-
0034871451
-
A multivariate analysis of 416 patients with glioblastoma multiforme: Prognosis, extent of resection, and survival
-
M Lacroix D Abi-Said DR Fourney, et al. 2001 A multivariate analysis of 416 patients with glioblastomamultiforme: prognosis, extent of resection, and survival J Neurosurg 95 190 198 11780887 10.3171/jns.2001.95.2.0190 1:STN:280:DC%2BD38%2FlsFGitA%3D%3D (Pubitemid 32799739)
-
(2001)
Journal of Neurosurgery
, vol.95
, Issue.2
, pp. 190-198
-
-
Lacroix, M.1
Abi-Said, D.2
Fourney, D.R.3
Gokaslan, Z.L.4
Shi, W.5
DeMonte, F.6
Lang, F.F.7
McCutcheon, I.E.8
Hassenbusch, S.J.9
Holland, E.10
Hess, K.11
Michael, C.12
Miller, D.13
Sawaya, R.14
-
4
-
-
14744272782
-
Survival rates in patients with low-grade glioma after intraoperative magnetic resonance image guidance
-
DOI 10.1002/cncr.20867
-
EB Claus A Horlacher L Hsu, et al. 2005 Survival rates in patients with low-grade glioma after intraoperative magnetic resonance image guidance Cancer 103 1227 1232 15690327 10.1002/cncr.20867 (Pubitemid 40328094)
-
(2005)
Cancer
, vol.103
, Issue.6
, pp. 1227-1233
-
-
Claus, E.B.1
Horlacher, A.2
Hsu, L.3
Schwartz, R.B.4
Dello-Iacono, D.5
Talos, F.6
Jolesz, F.A.7
Black, P.M.8
-
5
-
-
33645986455
-
Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: A randomised controlled multicentre phase III trial
-
16648043 10.1016/S1470-2045(06)70665-9 1:CAS:528:DC%2BD28XjvFWlsb0%3D
-
W Stummer U Pichlmeier T Meinel, et al. 2006 Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trial Lancet Oncol 7 5 392 401 16648043 10.1016/S1470-2045(06)70665-9 1:CAS:528:DC%2BD28XjvFWlsb0%3D
-
(2006)
Lancet Oncol
, vol.7
, Issue.5
, pp. 392-401
-
-
Stummer, W.1
Pichlmeier, U.2
Meinel, T.3
-
8
-
-
1342332067
-
Clinical application of robotic telemanipulation system in neurosurgery: Case report
-
T Goto K Hongo Y Kakizawa 2003 Clinical application of robotic telemanipulation system in neurosurgery J Neurosurg 99 6 1082 1084 14705738 10.3171/jns.2003.99.6.1082 (Pubitemid 44717406)
-
(2003)
Journal of Neurosurgery
, vol.99
, Issue.6
, pp. 1082-1084
-
-
Goto, T.1
Hongo, K.2
Kakizawa, Y.3
Muraoka, H.4
Miyairi, Y.5
Tanaka, Y.6
Kobayashi, S.7
-
9
-
-
25444488029
-
Microsurgical robotic system for the deep surgical field: Development of a prototype and feasibility studies in animal and cadaveric models
-
A Morita S Shigeo M Mitsuishi 2005 Microsurgical robotic system for the deep surgical field: development of a rototype and feasibility studies in animal and cadaveric models J Neurosurg 103 2 320 327 16175863 10.3171/jns.2005.103.2. 0320 (Pubitemid 43193909)
-
(2005)
Journal of Neurosurgery
, vol.103
, Issue.2
, pp. 320-327
-
-
Morita, A.1
Sora, S.2
Mitsuishi, M.3
Warisawa, S.4
Suruman, K.5
Asai, D.6
Arata, J.7
Baba, S.8
Takahashi, H.9
Mochizuki, R.10
Kirino, T.11
-
10
-
-
44349110795
-
Integrating an image-guided robot with intraoperative MRI
-
DOI 10.1109/EMB.2007.910272
-
GR Sutherland I Latour AD Greer 2008 Integrating an imageguided robot with intraoperative MRI: a review of the design and construction of neuroArm IEEE Eng Med Biol Mag 27 59 65 18519183 10.1109/EMB.2007.910272 (Pubitemid 351748045)
-
(2008)
IEEE Engineering in Medicine and Biology Magazine
, vol.27
, Issue.3
, pp. 59-65
-
-
Sutherland, G.R.1
Latour, I.2
Greer, A.D.3
-
11
-
-
77950789150
-
PWM type amorphous wire CMOS IC magneto-impedance sensor having high temperature stability
-
10.1109/TMAG.2008.2003175
-
Y Nakamura T Uchiyama CM Cai, et al. 2008 PWM type amorphous wire CMOS IC magneto-impedance sensor having high temperature stability IEEE Trans Magn 44 11. Part2 3981 3984 10.1109/TMAG.2008.2003175
-
(2008)
IEEE Trans Magn
, vol.44
, Issue.11 PART 2
, pp. 3981-3984
-
-
Nakamura, Y.1
Uchiyama, T.2
Cai, C.M.3
-
13
-
-
77953617196
-
Open core control software for surgical robots
-
10.1007/s11548-009-0388-9
-
J Arata H Kozuka HW Kim, et al. 2010 Open core control software for surgical robots Int J CARS 5 3 211 220 10.1007/s11548-009-0388-9
-
(2010)
Int J CARS
, vol.5
, Issue.3
, pp. 211-220
-
-
Arata, J.1
Kozuka, H.2
Kim, H.W.3
-
16
-
-
79956227680
-
Extirpating brain tumor using a volume controllable suction tube
-
Y Tada A Sano Y Hayashi, et al. 2010 Extirpating brain tumor using a volume controllable suction tube Int J CARS 5 Suppl 1 S257 S258
-
(2010)
Int J CARS
, vol.5
, Issue.SUPPL. 1
-
-
Tada, Y.1
Sano, A.2
Hayashi, Y.3
-
17
-
-
79956202390
-
Development of a back born shape allay force sensor using fiber optic
-
(in Japanese)
-
J Arata S Terakawa H Fujimoto 2009 Development of a back born shape allay force sensor using fiber optic J JSCAS 11 3 344 345 (in Japanese)
-
(2009)
J JSCAS
, vol.11
, Issue.3
, pp. 344-345
-
-
Arata, J.1
Terakawa, S.2
Fujimoto, H.3
-
20
-
-
84983156923
-
An integrated visualization system for surgical planning and guidance using image fusion and interventional imaging
-
D Gering A Nabavi R Kikinis, et al. 1999 An integrated visualization system for surgical planning and guidance using image fusion and interventional imaging Int Conf Med Image Comput Comput Assist Interv 2 809 819
-
(1999)
Int Conf Med Image Comput Comput Assist Interv
, vol.2
, pp. 809-819
-
-
Gering, D.1
Nabavi, A.2
Kikinis, R.3
-
21
-
-
79956198503
-
-
Open Core Control software (2010) http://svn.na-mic.org/NAMICSandBox/ trunk/IntelligentSI/Control/
-
(2010)
Open Core Control Software
-
-
|