1
-
-
0036056821
-
Alumina-onalumina total hip arthroplasty: A minimum 18.5-year follow-up study
-
Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-onalumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69-77.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 69-77
-
-
Hamadouche, M.1
Boutin, P.2
Daussange, J.3
Bolander, M.E.4
Sedel, L.5
-
2
-
-
0033781825
-
Alumina ceramic bearings for hip endoprostheses: The Austrian experiences
-
Boehler M, Plenk H Jr, Salzer M. Alumina ceramic bearings for hip endoprostheses: the Austrian experiences. Clin Orthop Relat Res. 2000;379:85-93.
-
(2000)
Clin Orthop Relat Res
, vol.379
, pp. 85-93
-
-
Boehler, M.1
Plenk Jr., H.2
Salzer, M.3
-
3
-
-
79953857652
-
-
New York Times, May 11, Accessed 2010 Nov 5
-
Feder BJ. That must be Bob. I hear his new hip squeaking. New York Times. 2008 May 11. http://www.nytimes.com/2008/05/11/business/11hip.html?fta=y. Accessed 2010 Nov 5.
-
(2008)
That Must Be Bob. i Hear His New Hip Squeaking
-
-
Feder, B.J.1
-
4
-
-
34249933860
-
Squeaking in Ceramic-on-Ceramic Hips. The Importance of Acetabular Component Orientation
-
DOI 10.1016/j.arth.2006.06.018, PII S0883540306005122
-
Walter WL, O'Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-onceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496-503. (Pubitemid 46880178)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.4
, pp. 496-503
-
-
Walter, W.L.1
O'Toole, G.C.2
Walter, W.K.3
Ellis, A.4
Zicat, B.A.5
-
5
-
-
33845389612
-
Early diagnosis of ceramic liner fracture: Guidelines based on a twelve-year clinical experience
-
DOI 10.2106/JBJS.F.00587
-
Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, Squarzoni S. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88 Suppl 4:55-63. (Pubitemid 44901974)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.SUPPL. 4
, pp. 55-63
-
-
Toni, A.1
Traina, F.2
Stea, S.3
Sudanese, A.4
Visentin, M.5
Bordini, B.6
Squarzoni, S.7
-
6
-
-
48949118899
-
The Noisy Ceramic Hip: Is Component Malpositioning the Cause?
-
DOI 10.1016/j.arth.2008.04.001, PII S0883540308004403
-
Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008;23:643-9. (Pubitemid 352004114)
-
(2008)
Journal of Arthroplasty
, vol.23
, Issue.5
, pp. 643-649
-
-
Restrepo, C.1
Parvizi, J.2
Kurtz, S.M.3
Sharkey, P.F.4
Hozack, W.J.5
Rothman, R.H.6
-
9
-
-
67649881919
-
The squeaking hip: A phenomenon of ceramic-on-ceramic total hip arthroplasty
-
Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344-9.
-
(2009)
J Bone Joint Surg Am
, vol.91
, pp. 1344-1349
-
-
Jarrett, C.A.1
Ranawat, A.S.2
Bruzzone, M.3
Blum, Y.C.4
Rodriguez, J.A.5
Ranawat, C.S.6
-
10
-
-
77955565740
-
The squeaking hip is a multifactorial concern
-
Accessed 2010 Nov 5
-
Rodriquez JA. The squeaking hip is a multifactorial concern. Orthop Today. 2008;28:92. http://www.orthosupersite.com/view.aspx?rid=27495. Accessed 2010 Nov 5.
-
(2008)
Orthop Today
, vol.28
, pp. 92
-
-
Rodriquez, J.A.1
-
11
-
-
0035215635
-
Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
-
DOI 10.1054/arth.2001.27233
-
Morlock M, Nassutt R, Janssen R, Willmann G, Honl M. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001;16:1071-4. (Pubitemid 33151887)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.8
, pp. 1071-1074
-
-
Morlock, M.1
Nassutt, R.2
Janssen, R.3
Willmann, G.4
Honl, M.5
-
12
-
-
33845347570
-
Squeaking in ceramic on ceramic total hip
-
Zippel H, Dietrich M, editors, 2003 Mar 28-29. Darmstadt, Germany: Steinkopf 13
-
Eickmann TH, Clarke IC, Gustafson GA. Squeaking in ceramic on ceramic total hip. In: Zippel H, Dietrich M, editors. Ceramics in orthopaedics. Bioceramics in joint arthroplasty: 8th BIOLOX Symposium Proceedings; 2003 Mar 28-29. Darmstadt, Germany: Steinkopf; 2003. p 187-92.13.
-
(2003)
Ceramics in Orthopaedics. Bioceramics in Joint Arthroplasty: 8th BIOLOX Symposium Proceedings
, pp. 187-192
-
-
Eickmann, T.H.1
Clarke, I.C.2
Gustafson, G.A.3
-
13
-
-
55649088197
-
Osteolysis in thirdgeneration alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis
-
e13-9
-
Murali R, Bonar SF, Kirsh G, Walter WK, Walter WL. Osteolysis in thirdgeneration alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. J Arthroplasty. 2008;23:1240.e13-9.
-
(2008)
J Arthroplasty
, vol.23
, pp. 1240
-
-
Murali, R.1
Bonar, S.F.2
Kirsh, G.3
Walter, W.K.4
Walter, W.L.5
-
14
-
-
38949162593
-
A Rare Complication of Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty
-
DOI 10.1016/j.arth.2006.12.046, PII S0883540306008904
-
Rosneck J, Klika A, Barsoum W. A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty. J Arthroplasty. 2008;23:311-3. (Pubitemid 351226491)
-
(2008)
Journal of Arthroplasty
, vol.23
, Issue.2
, pp. 311-313
-
-
Rosneck, J.1
Klika, A.2
Barsoum, W.3
-
16
-
-
58149337269
-
Squeaking in total hip replacement: No cause for concern
-
884
-
Ecker TM, Robbins C, van Flandern G, Patch D, Steppacher SD, Bierbaum B, Murphy SB. Squeaking in total hip replacement: no cause for concern. Orthopedics. 2008;31:875-6, 884.
-
(2008)
Orthopedics
, vol.31
, pp. 875-876
-
-
Ecker, T.M.1
Robbins, C.2
Van Flandern, G.3
Patch, D.4
Steppacher, S.D.5
Bierbaum, B.6
Murphy, S.B.7
-
17
-
-
0027479381
-
The definition and measurement of acetabular orientation
-
Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993;75:228-32. (Pubitemid 23087178)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.2
, pp. 228-232
-
-
Murray, D.W.1
-
18
-
-
62349119720
-
Measurement of the acetabular cup anteversion on simulated radiographs
-
Liaw CK, Yang RS, Hou SM, Wu TY, Fuh CS. Measurement of the acetabular cup anteversion on simulated radiographs. J Arthroplasty. 2009;24:468-74.
-
(2009)
J Arthroplasty
, vol.24
, pp. 468-474
-
-
Liaw, C.K.1
Yang, R.S.2
Hou, S.M.3
Wu, T.Y.4
Fuh, C.S.5
-
19
-
-
79953870247
-
-
Standard test methods for determining average grain size. West Conshohocken: ASTM International; 2004
-
ASTM Standard E112 - 96(2004)e2 Standard test methods for determining average grain size. West Conshohocken: ASTM International; 2004.
-
(2004)
ASTM Standard E112
, vol.96
-
-
-
21
-
-
34547291715
-
Ceramics for prosthetic hip and knee joint replacement
-
DOI 10.1111/j.1551-2916.2007.01725.x
-
Rahaman MN, Yao A, Bal BS, Garino JP, Ries MD. Ceramics for prosthetic hip and knee joint replacement. J Am Ceram Soc. 2007;90:1965-88. (Pubitemid 47146904)
-
(2007)
Journal of the American Ceramic Society
, vol.90
, Issue.7
, pp. 1965-1988
-
-
Rahaman, M.N.1
Yao, A.2
Bal, B.S.3
Garino, J.P.4
Ries, M.D.5
-
22
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
-
DOI 10.1016/S0142-9612(99)00081-2, PII S0142961299000812
-
Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials. 1999;20:1833-40. (Pubitemid 29421733)
-
(1999)
Biomaterials
, vol.20
, Issue.19
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Fisher, J.4
Nevelos, A.B.5
-
23
-
-
0031758471
-
Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces
-
Yoon TR, Rowe SM, Jung ST, Seon KJ, Maloney WJ. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg Am. 1998;80:1459-68. (Pubitemid 28503260)
-
(1998)
Journal of Bone and Joint Surgery - Series A
, vol.80
, Issue.10
, pp. 1459-1468
-
-
Yoon, T.R.1
Rowe, S.M.2
Jung, S.T.3
Seon, K.J.4
Maloney, W.J.5
-
24
-
-
0033038236
-
Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro
-
DOI 10.1302/0301-620X.81B3.8737
-
Catelas I, Petit A, Marchand R, Zukor DJ, Yahia L, Huk OL. Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg Br. 1999;81:516-21. (Pubitemid 29245912)
-
(1999)
Journal of Bone and Joint Surgery - Series B
, vol.81
, Issue.3
, pp. 516-521
-
-
Catelas, I.1
Petit, A.2
Marchand, R.3
Zukor, D.J.4
Yahia, L'H.5
Huk, O.L.6
-
25
-
-
0036145052
-
Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyenthylene particles
-
DOI 10.1016/S0736-0266(01)00077-8
-
Petit A, Catelas I, Antoniou J, Zukor DJ, Huk OL. Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles. J Orthop Res. 2002;20:9-15. (Pubitemid 34071415)
-
(2002)
Journal of Orthopaedic Research
, vol.20
, Issue.1
, pp. 9-15
-
-
Petit, A.1
Catelas, I.2
Antoniou, J.3
Zukor, D.J.4
Huk, O.L.5
-
27
-
-
55849139351
-
Squeaking hips
-
Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, Hozack WJ, Tuke MA. Squeaking hips. J Bone Joint Surg Am. 2008;90 Suppl 4:102-11.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL. 4
, pp. 102-111
-
-
Walter, W.L.1
Waters, T.S.2
Gillies, M.3
Donohoo, S.4
Kurtz, S.M.5
Ranawat, A.S.6
Hozack, W.J.7
Tuke, M.A.8
-
28
-
-
79953871297
-
Squeaking ceramic-on-ceramic total hip replacements-A numerical vibration approach
-
Hothan A, Weiss C, Morlock MM, Hoffmann N. Squeaking ceramic-on-ceramic total hip replacements-a numerical vibration approach. J Biomech. 2008;41 Suppl 1:S435.
-
(2008)
J Biomech
, vol.41
, Issue.SUPPL. 1
-
-
Hothan, A.1
Weiss, C.2
Morlock, M.M.3
Hoffmann, N.4
-
30
-
-
0035176116
-
Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results
-
Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, Miller RK. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am. 2001;83:1688-94.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 1688-1694
-
-
Urban, J.A.1
Garvin, K.L.2
Boese, C.K.3
Bryson, L.4
Pedersen, D.R.5
Callaghan, J.J.6
Miller, R.K.7
-
31
-
-
0027407506
-
In vivo wear of polyethylene acetabular components
-
Kabo JM, Gebhard JS, Loren G, Amstutz HC. In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br. 1993;75:254-8. (Pubitemid 23087182)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.2
, pp. 254-258
-
-
Kabo, J.M.1
Gebhard, J.S.2
Loren, G.3
Amstutz, H.C.4
-
32
-
-
0028345998
-
Polyethylene wear in uncemented acetabular components
-
Hernandez JR, Keating EM, Farris PM, Meding JB, Ritter MA. Polyethylene wear in uncemented acetabular components. J Bone Joint Surg Br. 1994;76:263-6. (Pubitemid 24083244)
-
(1994)
Journal of Bone and Joint Surgery - Series B
, vol.76
, Issue.2
, pp. 263-266
-
-
Hernandez, J.R.1
Keating, E.M.2
Faris, P.M.3
Meding, J.B.4
Ritter, M.A.5
-
33
-
-
14844286982
-
Metal-on-metal total hip replacement: What does the literature say?
-
DOI 10.1016/j.arth.2004.08.011
-
Dumbleton JH, Manley MT. Metal-on-metal total hip replacement: what does the literature say? J Arthroplasty. 2005;20:174-88. (Pubitemid 40342704)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.2
, pp. 174-188
-
-
Dumbleton, J.H.1
Manley, M.T.2
-
35
-
-
0037785310
-
Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria
-
DOI 10.1016/S0142-9612(03)00120-0
-
Warashina H, Sakano S, Kitamura S, Yamauchi KI, Yamaguchi J, Ishiguro N, Hasegawa Y. Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria. Biomaterials. 2003;24:3655-61. (Pubitemid 36773601)
-
(2003)
Biomaterials
, vol.24
, Issue.21
, pp. 3655-3661
-
-
Warashina, H.1
Sakano, S.2
Kitamura, S.3
Yamauchi, K.-I.4
Yamaguchi, J.5
Ishiguro, N.6
Hasegawa, Y.7
-
36
-
-
16644390786
-
Particle bioreactivity and wear-mediated osteolysis
-
Wang ML, Sharkey PF, Tuan RS. Particle bioreactivity and wear-mediated osteolysis. J Arthroplasty. 2004;19:1028-38.
-
(2004)
J Arthroplasty
, vol.19
, pp. 1028-1038
-
-
Wang, M.L.1
Sharkey, P.F.2
Tuan, R.S.3
-
37
-
-
52749083004
-
The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses
-
Revell PA. The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses. J R Soc Interface. 2008;5:1263-78.
-
(2008)
J R Soc Interface
, vol.5
, pp. 1263-1278
-
-
Revell, P.A.1
-
38
-
-
74449092529
-
A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions
-
Glaser D, Komistek RD, Cates HE, Mahfouz MR. A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions. J Biomech. 2010;43:426-32.
-
(2010)
J Biomech
, vol.43
, pp. 426-432
-
-
Glaser, D.1
Komistek, R.D.2
Cates, H.E.3
Mahfouz, M.R.4
|