메뉴 건너뛰기




Volumn 44, Issue 8, 1999, Pages 2015-2027

A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner

Author keywords

[No Author keywords available]

Indexed keywords

GALLIUM 68;

EID: 0032765446     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/8/312     Document Type: Article
Times cited : (92)

References (14)
  • 3
    • 0028606312 scopus 로고
    • Use of a magnetic field to increase the spatial resolution of positron emission tomography
    • Hammer B E, Christensen N L and Heil B G 1994 Use of a magnetic field to increase the spatial resolution of positron emission tomography Med. Phys. 21 1917-20
    • (1994) Med. Phys. , vol.21 , pp. 1917-1920
    • Hammer, B.E.1    Christensen, N.L.2    Heil, B.G.3
  • 4
    • 0001040102 scopus 로고
    • A simulation study to reduce positron annihilation spread distributions using a strong magnetic field in positron emission tomography
    • Iida H, Kanno I Miura S, Murakami M, Takahashi K and Uemura K 1986 A simulation study to reduce positron annihilation spread distributions using a strong magnetic field in positron emission tomography IEEE Trans. Nucl. Sci. 33 597-600
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , pp. 597-600
    • Iida, H.1    Kanno, I.2    Miura, S.3    Murakami, M.4    Takahashi, K.5    Uemura, K.6
  • 8
    • 0025266992 scopus 로고
    • Quality assurance methods and phantoms for magnetic resonance imaging: Report of AAPM nuclear magnetic resonance task group no 1
    • Price R R, Axel L, Morgan T, Newman R, Perman W, Schneiders N, Selikson M, Wood M and Thomas S R 1990 Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group no 1 Med. Phys. 17 287-95
    • (1990) Med. Phys. , vol.17 , pp. 287-295
    • Price, R.R.1    Axel, L.2    Morgan, T.3    Newman, R.4    Perman, W.5    Schneiders, N.6    Selikson, M.7    Wood, M.8    Thomas, S.R.9
  • 9
    • 0030215777 scopus 로고    scopus 로고
    • Combined MRI-PET scanner: A Monte Carlo evaluation of the improvements in PET resolution due to the effects of a static homogeneous magnetic field
    • Raylman R R, Hammer B E and Christensen N L 1996 Combined MRI-PET scanner: a Monte Carlo evaluation of the improvements in PET resolution due to the effects of a static homogeneous magnetic field IEEE Trans. Nucl. Sci. 43 2406-12
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 2406-2412
    • Raylman, R.R.1    Hammer, B.E.2    Christensen, N.L.3
  • 14
    • 0031117038 scopus 로고    scopus 로고
    • 4.5 Tesla magnetic field reduced range of high energy positrons - Potential implications for positron emission tomography
    • Wirrwar A, Vosberg H, Herzog H, Halling H, Weber S and Müller-Gärtner H 1997 4.5 Tesla magnetic field reduced range of high energy positrons - potential implications for positron emission tomography IEEE Trans. Nucl. Sci. 44 184-9
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 184-189
    • Wirrwar, A.1    Vosberg, H.2    Herzog, H.3    Halling, H.4    Weber, S.5    Müller-Gärtner, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.