메뉴 건너뛰기




Volumn 4, Issue , 2004, Pages 2334-2338

The RatCAP conscious small animal PET tomograph

Author keywords

[No Author keywords available]

Indexed keywords

MAXIMUM LIKELIHOOD EXPECTATION MAXIMIZATION (MLEM); MICRODIALYSIS; PET SCANS; SMALL ANIMAL POSITRON EMISSION TROMOGRAPHY;

EID: 23844474864     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 1
    • 33645210175 scopus 로고    scopus 로고
    • RatCAP: Miniaturized head mounted PET for conscious rodent brain imaging
    • Paper M3-7
    • P.Vaska et.al., "RatCAP: Miniaturized Head Mounted PET for Conscious Rodent Brain Imaging", IEEE NSS/MIC Conference Record, paper M3-7,
    • IEEE NSS/MIC Conference Record
    • Vaska, P.1
  • 3
    • 0035555136 scopus 로고    scopus 로고
    • Imaging the unanesthetized rat brain with PET: A feasibility study
    • P.Vaska et.al., "Imaging the Unanesthetized Rat Brain with PET: A Feasibility Study", IEEE NSS/MIC Conference Record, Vol. 3, pp 1569-1571, 2001.
    • (2001) IEEE NSS/MIC Conference Record , vol.3 , pp. 1569-1571
    • Vaska, P.1
  • 4
    • 2942754331 scopus 로고    scopus 로고
    • RatCAP: A small head-mounted PET tomograph for imaging the brain of an awake rat
    • C.Woody et.al., "RatCAP: A Small Head-Mounted PET Tomograph for Imaging the Brain of an Awake Rat", Nucl. Inst. Meth., Vol 527, pp. 166-170, 2004
    • (2004) Nucl. Inst. Meth. , vol.527 , pp. 166-170
    • Woody, C.1
  • 5
    • 33645190899 scopus 로고    scopus 로고
    • Proteus, Inc, Chagrin Falls, OH
    • Proteus, Inc, Chagrin Falls, OH.
  • 6
    • 11944263486 scopus 로고    scopus 로고
    • Light output measurements of LSO single crystals and 4×8 arrays: Comparison of experiment with Monte Carlo simulations
    • Paper M14-183
    • A.Kriplani et.al., "Light Output Measurements of LSO Single Crystals and 4×8 Arrays: Comparison of Experiment with Monte Carlo Simulations", IEEE NSS/MIC Conference Record, paper M14-183, 2003.
    • (2003) IEEE NSS/MIC Conference Record
    • Kriplani, A.1
  • 7
    • 33645195319 scopus 로고    scopus 로고
    • PDAQ - A fast data acquisition system for the RatCAP tomograph
    • paper N33-41 presented at this conference and submitted to the
    • M.Purschke et.al., "PDAQ - A Fast Data Acquisition System for the RatCAP Tomograph", paper N33-41 presented at this conference and submitted to the Conference Record.
    • Conference Record
    • Purschke, M.1
  • 8
    • 19944430047 scopus 로고    scopus 로고
    • Front End Electronics for the RatCAP Mobile Animal PET Scanner
    • Paper N1-7
    • J.-F. Pratte et.al., "Front End Electronics for the RatCAP Mobile Animal PET Scanner", NSS/MIC Conference Record, paper N1-7, 2003
    • (2003) NSS/MIC Conference Record
    • Pratte, J.-F.1
  • 9
    • 33645206332 scopus 로고    scopus 로고
    • accepted for publication
    • and accepted for publication in the IEEE Trans. Nucl. Sci.
    • IEEE Trans. Nucl. Sci.
  • 10
    • 33645204348 scopus 로고    scopus 로고
    • Timing discriminator and 32 line address prority serial encoder for the front end electronics for the RatCAP tomograph
    • paper N45-2 presented at this conference and submitted to the
    • J.-F. Pratte et.al., "Timing Discriminator and 32 Line Address Prority Serial Encoder for the Front End Electronics for the RatCAP Tomograph", paper N45-2 presented at this conference and submitted to the Conference Record.
    • Conference Record
    • Pratte, J.-F.1
  • 12
    • 11844286331 scopus 로고    scopus 로고
    • System performance simulations of the RatCAP awake rat brain scanner
    • Paper M7-6
    • S.Shokouhi et.al., "System Performance Simulations of the RatCAP Awake Rat Brain Scanner", IEEE NSS/MIC Conference Record, paper M7-6, 2003
    • (2003) IEEE NSS/MIC Conference Record
    • Shokouhi, S.1
  • 13
    • 33645208242 scopus 로고    scopus 로고
    • submitted for publication
    • and submitted for publication in the IEEE Trans. Nucl. Sci.
    • IEEE Trans. Nucl. Sci.
  • 15
    • 33645196279 scopus 로고    scopus 로고
    • Statistical 3D image reconstruction for the RatCAP PET tomograph using a physically accurate, Monte Carlo based system matrix
    • paper M10-136 presented at this conference and submitted to the
    • S.Shohouhi et.al., "Statistical 3D Image Reconstruction for the RatCAP PET Tomograph Using a Physically Accurate, Monte Carlo Based System Matrix", paper M10-136 presented at this conference and submitted to the Conference Record.
    • Conference Record
    • Shohouhi, S.1
  • 16
    • 0345734448 scopus 로고    scopus 로고
    • Development and evaluation of an automated atlas-based image analysis method for MicroPET studies of the rat brain
    • J.D.Rubins, W.P.Melega, G.Lacan, B.Way, A.Plenevaux, A.Luxen and S.R.Cherry, "Development and Evaluation of an Automated Atlas-based Image Analysis Method for MicroPET Studies of the Rat Brain", Neuroimage, Vol. 20, pp. 2100-2118, 2003.
    • (2003) Neuroimage , vol.20 , pp. 2100-2118
    • Rubins, J.D.1    Melega, W.P.2    Lacan, G.3    Way, B.4    Plenevaux, A.5    Luxen, A.6    Cherry, S.R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.