메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3400-3403

Silicon photomultiplier performance tests in magnetic resonance pulsed fields

Author keywords

MRI; PET; Photomultiplier; Silicon; SiPM

Indexed keywords

MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; MICROWAVE INTEGRATED CIRCUITS; PHOTOELECTRON SPECTROSCOPY; PHOTOMULTIPLIERS; POLYETHYLENE TEREPHTHALATES; POSITRON EMISSION TOMOGRAPHY; RESONANCE; SILICON;

EID: 48349087537     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436860     Document Type: Conference Paper
Times cited : (37)

References (17)
  • 1
    • 31544451791 scopus 로고    scopus 로고
    • The contribution of PET/CT to improved patient management
    • P. J. Ell, "The contribution of PET/CT to improved patient management," The British Journal of Radiology, vol. 79, pp. 32-36, 2006.
    • (2006) The British Journal of Radiology , vol.79 , pp. 32-36
    • Ell, P.J.1
  • 2
    • 0036449145 scopus 로고    scopus 로고
    • A combined PET/CT scanner: The path to true image fusion
    • D. W. Townsend and T. Beyer, "A combined PET/CT scanner: the path to true image fusion," British J. of Radiol., vol. 75, pp. S24-230. 2002.
    • (2002) British J. of Radiol , vol.75
    • Townsend, D.W.1    Beyer, T.2
  • 3
    • 0031365485 scopus 로고    scopus 로고
    • Performance test of a LSO-APD PET modules in a 9.4Tesla magnet
    • B. L. Pichler et al., "Performance test of a LSO-APD PET modules in a 9.4Tesla magnet." NSS, IEEE, vol. 2, pp. 1237-1239, 1997.
    • (1997) NSS, IEEE , vol.2 , pp. 1237-1239
    • Pichler, B.L.1
  • 4
    • 0035428676 scopus 로고    scopus 로고
    • A 4 × 8 APD array, consisting of two monolithic silicon wafers, coupled to a 32-channel LSO matrix for high-resolution PET
    • B. J. Pichler et al. "A 4 × 8 APD array, consisting of two monolithic silicon wafers, coupled to a 32-channel LSO matrix for high-resolution PET," Trans. Nucl. Sci., vol. 48. no. 4, pp. 1391-1396. 2001.
    • (2001) Trans. Nucl. Sci , vol.48 , Issue.4 , pp. 1391-1396
    • Pichler, B.J.1
  • 5
    • 33846341025 scopus 로고    scopus 로고
    • New trends on photodetectors
    • D. Renker. "New trends on photodetectors," Nucl. Instr. and Meth. A. pp. 1-6, 2007.
    • (2007) Nucl. Instr. and Meth. A , pp. 1-6
    • Renker, D.1
  • 7
    • 33846873900 scopus 로고    scopus 로고
    • Simultaneous MRI and PET imaging of a rat brain
    • R. R. Raylman et al., "Simultaneous MRI and PET imaging of a rat brain," Phys. Med. Biol., vol. 51, pp. 6371-6379, 2006.
    • (2006) Phys. Med. Biol , vol.51 , pp. 6371-6379
    • Raylman, R.R.1
  • 8
    • 0032765446 scopus 로고    scopus 로고
    • A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner
    • R. B. Slates et al., "A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner," Phys. Med. Biol., vol. 44, pp. 2015-2027, 1999.
    • (1999) Phys. Med. Biol , vol.44 , pp. 2015-2027
    • Slates, R.B.1
  • 9
    • 15844400111 scopus 로고    scopus 로고
    • Comparison of a silicon photomultiplier to a traditional vacuum photomultiplier
    • V. Kovaltchouk, G. Lolos, Z. Papandreou, and K. Wolbaum, "Comparison of a silicon photomultiplier to a traditional vacuum photomultiplier," Nucl. Instr. and Meth. A, pp. 408-415, 2005.
    • (2005) Nucl. Instr. and Meth. A , pp. 408-415
    • Kovaltchouk, V.1    Lolos, G.2    Papandreou, Z.3    Wolbaum, K.4
  • 10
    • 48349112244 scopus 로고    scopus 로고
    • Evaluation of silicon photomultipliers as novel PET detector
    • A. KoIb et al., "Evaluation of silicon photomultipliers as novel PET detector," 2007, conference Record (M 14-5).
    • (2007) conference Record (M , pp. 14-15
    • KoIb, A.1
  • 11
    • 48349089882 scopus 로고    scopus 로고
    • Performance evaluation of SSPM for DOI compatible PET detector
    • P. Dokhale el al., "Performance evaluation of SSPM for DOI compatible PET detector," 2007. conference Record (M14-6).
    • (2007) conference Record (M14-6)
    • Dokhale, P.1    el al2
  • 12
    • 48349126384 scopus 로고    scopus 로고
    • Silicon photomultipliers and SiPM matrices as photodetectors for scintillator readout in nuclear medicine
    • G. Llosa et al. "Silicon photomultipliers and SiPM matrices as photodetectors for scintillator readout in nuclear medicine," 2007, conference Record (M14-4).
    • (2007) conference Record (M14-4)
    • Llosa, G.1
  • 13
    • 33745111311 scopus 로고    scopus 로고
    • Performance test of an LSO-APD detector in a 7-T scanner for simultaneous PET/MRI
    • B. Pichler et al., "Performance test of an LSO-APD detector in a 7-T scanner for simultaneous PET/MRI," J. Nucl. Med., vol. 47, pp. 639-647.
    • J. Nucl. Med , vol.47 , pp. 639-647
    • Pichler, B.1
  • 15
    • 33847698111 scopus 로고    scopus 로고
    • Characterization of the first prototypes of silicon photomultiplier at ITC-irst
    • C. Piemonte et al. "Characterization of the first prototypes of silicon photomultiplier at ITC-irst," IEEE Trans. Nucl Sei., vol. 54, no. 1, pp. 236-244, 2006.
    • (2006) IEEE Trans. Nucl Sei , vol.54 , Issue.1 , pp. 236-244
    • Piemonte, C.1
  • 16
    • 33846982940 scopus 로고    scopus 로고
    • Development of the first prototypes of silicon photomultiplier (sipm) at ITC-irst
    • N. Dinu, "Development of the first prototypes of silicon photomultiplier (sipm) at ITC-irst," Nucl. Instr. and Meth. A, vol. 572. pp. 422-426, 2007.
    • (2007) Nucl. Instr. and Meth. A , vol.572 , pp. 422-426
    • Dinu, N.1
  • 17
    • 48349120437 scopus 로고    scopus 로고
    • Recent progress in the performance on the silicon photomultipliers produced at FBK-irst
    • C. Piemonte, "Recent progress in the performance on the silicon photomultipliers produced at FBK-irst," 2007, conference Record (N41-2).
    • (2007) conference Record , Issue.N41-2
    • Piemonte, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.