-
1
-
-
23944470905
-
An assessment of calibration and performance of the microdialysis system
-
Abrahamsson P, Winso O. An assessment of calibration and performance of the microdialysis system. J Pharm Biomed Anal 39: 730-734, 2005.
-
(2005)
J Pharm Biomed Anal
, vol.39
, pp. 730-734
-
-
Abrahamsson, P.1
Winso, O.2
-
2
-
-
0028314849
-
Changes in skin circulation after insertion of a microdialysis probe visualized by laser Doppler perfusion imaging
-
Anderson C, Andersson T, Wardell K. Changes in skin circulation after insertion of a microdialysis probe visualized by laser Doppler perfusion imaging. J Invest Dermatol 102: 807-811, 1994.
-
(1994)
J Invest Dermatol
, vol.102
, pp. 807-811
-
-
Anderson, C.1
Andersson, T.2
Wardell, K.3
-
3
-
-
0034442281
-
Techniques to study the pharmacodynamics of isolated large and small blood vessels
-
Angus JA, Wright CE. Techniques to study the pharmacodynamics of isolated large and small blood vessels. J Pharmacol Toxicol Methods 44: 395-407, 2000.
-
(2000)
J Pharmacol Toxicol Methods
, vol.44
, pp. 395-407
-
-
Angus, J.A.1
Wright, C.E.2
-
4
-
-
4344581417
-
Modulation of microvascular function following low-dose exposure to the organophosphorous compound malathion in human skin in vivo
-
Boutsiouki P, Clough GF. Modulation of microvascular function following low-dose exposure to the organophosphorous compound malathion in human skin in vivo. J Appl Physiol 97: 1091-1097, 2004.
-
(2004)
J Appl Physiol
, vol.97
, pp. 1091-1097
-
-
Boutsiouki, P.1
Clough, G.F.2
-
5
-
-
0034885752
-
Effects of local blood flow on the percutaneous absorption of the organophosphorus compound malathion: a microdialysis study in man
-
Boutsiouki P, Thompson JP, Clough GF. Effects of local blood flow on the percutaneous absorption of the organophosphorus compound malathion: a microdialysis study in man. Arch Toxicol 75: 321-328, 2001.
-
(2001)
Arch Toxicol
, vol.75
, pp. 321-328
-
-
Boutsiouki, P.1
Thompson, J.P.2
Clough, G.F.3
-
6
-
-
0036074165
-
Effects of blood flow on the in vivo recovery of a small diffusible molecule by microdialysis in human skin
-
Clough GF, Boutsiouki P, Church MK, Michel CC. Effects of blood flow on the in vivo recovery of a small diffusible molecule by microdialysis in human skin. J Pharmacol Exp Ther 302: 681-686, 2002.
-
(2002)
J Pharmacol Exp Ther
, vol.302
, pp. 681-686
-
-
Clough, G.F.1
Boutsiouki, P.2
Church, M.K.3
Michel, C.C.4
-
7
-
-
0029024575
-
Influence of local blood flow on glycerol levels in human adipose tissue
-
Enoksson S, Nordenstrom J, Bolinder J, Arner P. Influence of local blood flow on glycerol levels in human adipose tissue. Int J Obes Relat Metab Disord 19: 350-354, 1995.
-
(1995)
Int J Obes Relat Metab Disord
, vol.19
, pp. 350-354
-
-
Enoksson, S.1
Nordenstrom, J.2
Bolinder, J.3
Arner, P.4
-
8
-
-
72549083779
-
Urea clearance: a new method to register local changes in blood flow in rat skeletal muscle based on microdialysis
-
Farnebo S, Samuelsson A, Henriksson J, Karlander LE, Sjoberg F. Urea clearance: a new method to register local changes in blood flow in rat skeletal muscle based on microdialysis. Clin Physiol Funct Imaging 30: 57-63, 2010.
-
(2010)
Clin Physiol Funct Imaging
, vol.30
, pp. 57-63
-
-
Farnebo, S.1
Samuelsson, A.2
Henriksson, J.3
Karlander, L.E.4
Sjoberg, F.5
-
9
-
-
78249235571
-
Hyperaemic changes in forearm skin perfusion and RBC concentration after increasing occlusion times
-
Farnebo S, Thorfinn J, Henricson J, Tesselaar E. Hyperaemic changes in forearm skin perfusion and RBC concentration after increasing occlusion times. Microvasc Res 80: 412-416, 2010.
-
(2010)
Microvasc Res
, vol.80
, pp. 412-416
-
-
Farnebo, S.1
Thorfinn, J.2
Henricson, J.3
Tesselaar, E.4
-
10
-
-
77956804702
-
Urea clearance: a new technique based on microdialysis to assess liver blood flow studied in a pig model of ischemia/reperfusion
-
Farnebo S, Winbladh A, Zettersten EK, Sandstrom P, Gullstrand P, Samuelsson A, Theodorson E, Sjoberg F. Urea clearance: a new technique based on microdialysis to assess liver blood flow studied in a pig model of ischemia/reperfusion. Eur Surg Res 45: 105-112, 2010.
-
(2010)
Eur Surg Res
, vol.45
, pp. 105-112
-
-
Farnebo, S.1
Winbladh, A.2
Zettersten, E.K.3
Sandstrom, P.4
Gullstrand, P.5
Samuelsson, A.6
Theodorson, E.7
Sjoberg, F.8
-
11
-
-
67349106069
-
Measurement depth and volume in laser Doppler flowmetry
-
Fredriksson I, Larsson M, Stromberg T. Measurement depth and volume in laser Doppler flowmetry. Microvasc Res 78: 4-13, 2009.
-
(2009)
Microvasc Res
, vol.78
, pp. 4-13
-
-
Fredriksson, I.1
Larsson, M.2
Stromberg, T.3
-
12
-
-
0001278603
-
The circulation through the skin
-
Am. Physiol. Soc., Washington, D.C.
-
Greenfield ADM. The circulation through the skin. Handbook of Physiology. Am. Physiol. Soc., Washington, D.C. 1963, p. 1324.
-
(1963)
Handbook of Physiology
, pp. 1324
-
-
Greenfield, A.D.M.1
-
13
-
-
0026737833
-
The ethanol technique of monitoring local blood flow changes in rat skeletal muscle: implications for microdialysis
-
Hickner RC, Rosdahl H, Borg I, Ungerstedt U, Jorfeldt L, Henriksson J. The ethanol technique of monitoring local blood flow changes in rat skeletal muscle: implications for microdialysis. Acta Physiol Scand 146: 87-97, 1992.
-
(1992)
Acta Physiol Scand
, vol.146
, pp. 87-97
-
-
Hickner, R.C.1
Rosdahl, H.2
Borg, I.3
Ungerstedt, U.4
Jorfeldt, L.5
Henriksson, J.6
-
14
-
-
0029931581
-
Microdialysis methodology for the measurement of dermal interstitial fluid in humans
-
Krogstad AL, Jansson PA, Gisslen P, Lonnroth P. Microdialysis methodology for the measurement of dermal interstitial fluid in humans. Br J Dermatol 134: 1005-1012, 1996.
-
(1996)
Br J Dermatol
, vol.134
, pp. 1005-1012
-
-
Krogstad, A.L.1
Jansson, P.A.2
Gisslen, P.3
Lonnroth, P.4
-
15
-
-
77449088969
-
Tissue viability (TiVi) imaging: temporal effects of local occlusion studies in the volar forearm
-
McNamara PM, O'Doherty J, O'Connell ML, Fitzgerald BW, Anderson CD, Nilsson GE, Toll R, Leahy MJ. Tissue viability (TiVi) imaging: temporal effects of local occlusion studies in the volar forearm. J Biophotonics 3: 66-74, 2009.
-
(2009)
J Biophotonics
, vol.3
, pp. 66-74
-
-
McNamara, P.M.1
O'Doherty, J.2
O'Connell, M.L.3
Fitzgerald, B.W.4
Anderson, C.D.5
Nilsson, G.E.6
Toll, R.7
Leahy, M.J.8
-
16
-
-
0035658582
-
Nutritive blood flow affects microdialysis O/I ratio for [(14)C]ethanol and (3)H(2)O in perfused rat hindlimb
-
Newman JM, Di Maria CA, Rattigan S, Clark MG. Nutritive blood flow affects microdialysis O/I ratio for [(14)C]ethanol and (3)H(2)O in perfused rat hindlimb. Am J Physiol Heart Circ Physiol 281: H2731-H2737, 2001.
-
(2001)
Am J Physiol Heart Circ Physiol
, vol.281
-
-
Newman, J.M.1
Di Maria, C.A.2
Rattigan, S.3
Clark, M.G.4
-
17
-
-
63449140961
-
Cutaneous bioengineering instrumentation standardization: the Tissue Viability Imager
-
Nilsson GE, Zhai H, Chan HP, Farahmand S, Maibach HI. Cutaneous bioengineering instrumentation standardization: the Tissue Viability Imager. Skin Res Technol 15: 6-13, 2009.
-
(2009)
Skin Res Technol
, vol.15
, pp. 6-13
-
-
Nilsson, G.E.1
Zhai, H.2
Chan, H.P.3
Farahmand, S.4
Maibach, H.I.5
-
18
-
-
34848902395
-
Sub-epidermal imaging using polarized light spectroscopy for assessment of skin microcirculation
-
O'Doherty J, Henricson J, Anderson C, Leahy MJ, Nilsson GE, Sjoberg F. Sub-epidermal imaging using polarized light spectroscopy for assessment of skin microcirculation. Skin Res Technol 13: 472-484, 2007.
-
(2007)
Skin Res Technol
, vol.13
, pp. 472-484
-
-
O'Doherty, J.1
Henricson, J.2
Anderson, C.3
Leahy, M.J.4
Nilsson, G.E.5
Sjoberg, F.6
-
19
-
-
0027424423
-
Interstitial glucose and lactate balance in human skeletal muscle and adipose tissue studied by microdialysis
-
Rosdahl H, Ungerstedt U, Jorfeldt L, Henriksson J. Interstitial glucose and lactate balance in human skeletal muscle and adipose tissue studied by microdialysis. J Physiol 471: 637-657, 1993.
-
(1993)
J Physiol
, vol.471
, pp. 637-657
-
-
Rosdahl, H.1
Ungerstedt, U.2
Jorfeldt, L.3
Henriksson, J.4
-
20
-
-
0020900381
-
Rhythmical variations in human skin blood flow
-
Salerud EG, Tenland T, Nilsson GE, Oberg PA. Rhythmical variations in human skin blood flow. Int J Microcirc Clin Exp 2: 91-102, 1983.
-
(1983)
Int J Microcirc Clin Exp
, vol.2
, pp. 91-102
-
-
Salerud, E.G.1
Tenland, T.2
Nilsson, G.E.3
Oberg, P.A.4
-
21
-
-
33645093422
-
Urea as an endogenous surrogate in human microdialysis to determine relative recovery of drugs: analytics and applications
-
Schwalbe O, Buerger C, Plock N, Joukhadar C, Kloft C. Urea as an endogenous surrogate in human microdialysis to determine relative recovery of drugs: analytics and applications. J Pharm Biomed Anal 41: 233-239, 2006.
-
(2006)
J Pharm Biomed Anal
, vol.41
, pp. 233-239
-
-
Schwalbe, O.1
Buerger, C.2
Plock, N.3
Joukhadar, C.4
Kloft, C.5
-
23
-
-
0034130777
-
Validation of an endogenous reference technique for the calibration of microdialysis catheters
-
Strindberg L, Lonnroth P. Validation of an endogenous reference technique for the calibration of microdialysis catheters. Scand J Clin Lab Invest 60: 205-211, 2000.
-
(2000)
Scand J Clin Lab Invest
, vol.60
, pp. 205-211
-
-
Strindberg, L.1
Lonnroth, P.2
-
24
-
-
36849006009
-
Evaluation of the microcirculation in hypertension and cardiovascular disease
-
Struijker-Boudier HA, Rosei AE, Bruneval P, Camici PG, Christ F, Henrion D, Levy BI, Pries A, Vanoverschelde JL. Evaluation of the microcirculation in hypertension and cardiovascular disease. Eur Heart J 28: 2834-2840, 2007.
-
(2007)
Eur Heart J
, vol.28
, pp. 2834-2840
-
-
Struijker-Boudier, H.A.1
Rosei, A.E.2
Bruneval, P.3
Camici, P.G.4
Christ, F.5
Henrion, D.6
Levy, B.I.7
Pries, A.8
Vanoverschelde, J.L.9
-
25
-
-
0020909943
-
Spatial and temporal variations in human skin blood flow
-
Tenland T, Salerud EG, Nilsson GE, Oberg PA. Spatial and temporal variations in human skin blood flow. Int J Microcirc Clin Exp 2: 81-90, 1983.
-
(1983)
Int J Microcirc Clin Exp
, vol.2
, pp. 81-90
-
-
Tenland, T.1
Salerud, E.G.2
Nilsson, G.E.3
Oberg, P.A.4
-
29
-
-
61949199755
-
Effect of elevated local temperature on cutaneous vasoconstrictor responsiveness in humans
-
Wingo JE, Low DA, Keller DM, Brothers RM, Shibasaki M, Crandall CG. Effect of elevated local temperature on cutaneous vasoconstrictor responsiveness in humans. J Appl Physiol 106: 571-575, 2009.
-
(2009)
J Appl Physiol
, vol.106
, pp. 571-575
-
-
Wingo, J.E.1
Low, D.A.2
Keller, D.M.3
Brothers, R.M.4
Shibasaki, M.5
Crandall, C.G.6
-
30
-
-
63449090408
-
Comparison of tissue viability imaging and colorimetry: skin blanching
-
Zhai H, Chan HP, Farahmand S, Nilsson GE, Maibach HI. Comparison of tissue viability imaging and colorimetry: skin blanching. Skin Res Technol 15: 20-23, 2009.
-
(2009)
Skin Res Technol
, vol.15
, pp. 20-23
-
-
Zhai, H.1
Chan, H.P.2
Farahmand, S.3
Nilsson, G.E.4
Maibach, H.I.5
-
31
-
-
63449139879
-
Tissue viability imaging: mapping skin erythema
-
Zhai H, Chan HP, Farahmand S, Nilsson GE, Maibach HI. Tissue viability imaging: mapping skin erythema. Skin Res Technol 15: 14-19, 2009.
-
(2009)
Skin Res Technol
, vol.15
, pp. 14-19
-
-
Zhai, H.1
Chan, H.P.2
Farahmand, S.3
Nilsson, G.E.4
Maibach, H.I.5
|