메뉴 건너뛰기




Volumn 78, Issue 1, 2009, Pages 4-13

Measurement depth and volume in laser Doppler flowmetry

Author keywords

Laser Doppler flowmetry; Laser Doppler perfusion imaging; Laser Doppler perfusion monitoring; Measurement volume; Monte Carlo simulations; Multiple Doppler shifts; Sampling depth; Source detector separation; Tissue model

Indexed keywords

ACCURACY; ARTICLE; BLOOD OXYGEN TENSION; BLOOD VOLUME; CONTROLLED STUDY; GRAY MATTER; IMAGING SYSTEM; INDEX FINGER; LASER DOPPLER FLOWMETRY; LIVER; MONTE CARLO METHOD; MUSCLE; NONLINEAR SYSTEM; PRIORITY JOURNAL; SKIN PIGMENTATION; TISSUE BLOOD FLOW; TISSUE PERFUSION; TISSUE STRUCTURE; WHITE MATTER;

EID: 67349106069     PISSN: 00262862     EISSN: 10959319     Source Type: Journal    
DOI: 10.1016/j.mvr.2009.02.008     Document Type: Article
Times cited : (132)

References (34)
  • 1
    • 0031249901 scopus 로고    scopus 로고
    • Higher order moment processing of laser Doppler perfusion signals
    • Arildsson M.L., Wårdell K., and Nilsson G.E. Higher order moment processing of laser Doppler perfusion signals. J. Biomed. Opt. 2 4 (1997) 358-363
    • (1997) J. Biomed. Opt. , vol.2 , Issue.4 , pp. 358-363
    • Arildsson, M.L.1    Wårdell, K.2    Nilsson, G.E.3
  • 2
    • 0016220406 scopus 로고
    • Intracellular free amino acid concentration in human muscle tissue
    • Bergstrom J., Furst P., Noree L.O., and Vinnars E. Intracellular free amino acid concentration in human muscle tissue. J. Appl. Physiol. 36 6 (1974) 693-697
    • (1974) J. Appl. Physiol. , vol.36 , Issue.6 , pp. 693-697
    • Bergstrom, J.1    Furst, P.2    Noree, L.O.3    Vinnars, E.4
  • 3
    • 84958111940 scopus 로고
    • The absorption spectra and extinction coefficients of myoglobin
    • Bowen W.J. The absorption spectra and extinction coefficients of myoglobin. J. Biol. Chem. 179 1 (1949) 235-245
    • (1949) J. Biol. Chem. , vol.179 , Issue.1 , pp. 235-245
    • Bowen, W.J.1
  • 4
    • 84887196567 scopus 로고
    • Laser-Doppler velocimetry and Monte-Carlo simulations on models for blood perfusion in tissue
    • de Mul F.F.M., Koelink M.H., Kok M.L., Harmsma P.J., Greve J., Graaff R., and Aarnoudse J.G. Laser-Doppler velocimetry and Monte-Carlo simulations on models for blood perfusion in tissue. Appl. Opt. 34 28 (1995) 6595-6611
    • (1995) Appl. Opt. , vol.34 , Issue.28 , pp. 6595-6611
    • de Mul, F.F.M.1    Koelink, M.H.2    Kok, M.L.3    Harmsma, P.J.4    Greve, J.5    Graaff, R.6    Aarnoudse, J.G.7
  • 7
    • 44849144050 scopus 로고    scopus 로고
    • Optical microcirculatory skin model: assessed by Monte Carlo simulations paired with in vivo laser Doppler flowmetry
    • Fredriksson I., Larsson M., and Strömberg T. Optical microcirculatory skin model: assessed by Monte Carlo simulations paired with in vivo laser Doppler flowmetry. J. Biomed. Opt. 13 1 (2008) 014015
    • (2008) J. Biomed. Opt. , vol.13 , Issue.1 , pp. 014015
    • Fredriksson, I.1    Larsson, M.2    Strömberg, T.3
  • 8
    • 65449161312 scopus 로고    scopus 로고
    • Forced detection Monte Carlo algorithms for accelerated blood vessel image simulations
    • 10.1002/jbio.200810048
    • Fredriksson I., Larsson M., and Strömberg T. Forced detection Monte Carlo algorithms for accelerated blood vessel image simulations. J. Biophoton. 3 2 (2009) 178-184 10.1002/jbio.200810048
    • (2009) J. Biophoton. , vol.3 , Issue.2 , pp. 178-184
    • Fredriksson, I.1    Larsson, M.2    Strömberg, T.3
  • 9
  • 11
    • 0027591676 scopus 로고
    • Prediction of sampling depth and photon pathlength in laser Doppler flowmetry
    • Jakobsson A., and Nilsson G.E. Prediction of sampling depth and photon pathlength in laser Doppler flowmetry. Med. Biol. Eng. Comput. 31 3 (1993) 301-307
    • (1993) Med. Biol. Eng. Comput. , vol.31 , Issue.3 , pp. 301-307
    • Jakobsson, A.1    Nilsson, G.E.2
  • 12
    • 0020963889 scopus 로고
    • Myoglobin concentration in single type I and type II muscle fibres in man
    • Jansson E., and Sylvén C. Myoglobin concentration in single type I and type II muscle fibres in man. Histochemistry 78 1 (1983) 121-124
    • (1983) Histochemistry , vol.78 , Issue.1 , pp. 121-124
    • Jansson, E.1    Sylvén, C.2
  • 13
    • 0029746220 scopus 로고    scopus 로고
    • Determination of the optical properties of turbid media from a single Monte Carlo simulation
    • Kienle A., and Patterson M.S. Determination of the optical properties of turbid media from a single Monte Carlo simulation. Phys. Med. Biol. 41 10 (1996) 2221-2227
    • (1996) Phys. Med. Biol. , vol.41 , Issue.10 , pp. 2221-2227
    • Kienle, A.1    Patterson, M.S.2
  • 14
    • 0028458916 scopus 로고
    • Laser-Doppler blood flowmetry using two wavelengths - Monte-Carlo simulations and measurements
    • Koelink M.H., De Mul F.F.M., Greve J., Graaff R., Dassel A.C.M., and Aarnoudse J.G. Laser-Doppler blood flowmetry using two wavelengths - Monte-Carlo simulations and measurements. Appl. Opt. 33 16 (1994) 3549-3558
    • (1994) Appl. Opt. , vol.33 , Issue.16 , pp. 3549-3558
    • Koelink, M.H.1    De Mul, F.F.M.2    Greve, J.3    Graaff, R.4    Dassel, A.C.M.5    Aarnoudse, J.G.6
  • 15
    • 0036525877 scopus 로고    scopus 로고
    • Influence of optical properties and fiber separation on laser Doppler flowmetry
    • Larsson M., Steenbergen W., and Strömberg N.O.T. Influence of optical properties and fiber separation on laser Doppler flowmetry. J. Biomed. Opt. 7 2 (2002) 236-243
    • (2002) J. Biomed. Opt. , vol.7 , Issue.2 , pp. 236-243
    • Larsson, M.1    Steenbergen, W.2    Strömberg, N.O.T.3
  • 16
    • 33744502654 scopus 로고    scopus 로고
    • Toward a velocity-resolved microvascular blood flow measure by decomposition of the laser Doppler spectrum
    • Larsson M., and Strömberg N.O.T. Toward a velocity-resolved microvascular blood flow measure by decomposition of the laser Doppler spectrum. J. Biomed. Opt. 11 1 (2006) 014024
    • (2006) J. Biomed. Opt. , vol.11 , Issue.1 , pp. 014024
    • Larsson, M.1    Strömberg, N.O.T.2
  • 17
    • 0035150624 scopus 로고    scopus 로고
    • Modelling the sampling volume for skin blood oxygenation measurements
    • Meglinsky I.V., and Matcher S.J. Modelling the sampling volume for skin blood oxygenation measurements. Med. Biol. Eng. Comput. 39 1 (2001) 44-50
    • (2001) Med. Biol. Eng. Comput. , vol.39 , Issue.1 , pp. 44-50
    • Meglinsky, I.V.1    Matcher, S.J.2
  • 18
    • 0018025571 scopus 로고
    • Atmospheric scattering of middle UV radiation from an internal source
    • Meier R.R., Lee J.-S., and Anderson Jr. D.E. Atmospheric scattering of middle UV radiation from an internal source. Appl. Opt. 17 20 (1978) 3216
    • (1978) Appl. Opt. , vol.17 , Issue.20 , pp. 3216
    • Meier, R.R.1    Lee, J.-S.2    Anderson Jr., D.E.3
  • 19
    • 0030306558 scopus 로고    scopus 로고
    • Some observations on the absorption spectra of various myoglobin derivatives found in meat
    • Millar S.J., Moss B.W., and Stevenson M.H. Some observations on the absorption spectra of various myoglobin derivatives found in meat. Meat. Sci. 42 3 (1996) 277-288
    • (1996) Meat. Sci. , vol.42 , Issue.3 , pp. 277-288
    • Millar, S.J.1    Moss, B.W.2    Stevenson, M.H.3
  • 22
    • 49649091827 scopus 로고    scopus 로고
    • Influence of tissue optical properties on laser Doppler perfusion imaging, accounting for photon penetration depth and the laser speckle phenomenon
    • Rajan V., Varghese B., Van Leeuwen T.G., and Steenbergen W. Influence of tissue optical properties on laser Doppler perfusion imaging, accounting for photon penetration depth and the laser speckle phenomenon. J. Biomed. Opt. 13 2 (2008)
    • (2008) J. Biomed. Opt. , vol.13 , Issue.2
    • Rajan, V.1    Varghese, B.2    Van Leeuwen, T.G.3    Steenbergen, W.4
  • 23
    • 0019068250 scopus 로고
    • Approximate two-parameter phase function for light scattering
    • Reynolds L.O., and McCormick N.J. Approximate two-parameter phase function for light scattering. J. Opt. Soc. Am. 70 10 (1980) 1206-1212
    • (1980) J. Opt. Soc. Am. , vol.70 , Issue.10 , pp. 1206-1212
    • Reynolds, L.O.1    McCormick, N.J.2
  • 24
    • 0034784638 scopus 로고    scopus 로고
    • Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm
    • Ritz J.P., Roggan A., Isbert C., Muller G., Buhr H.J., and Germer C.T. Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm. Laser Surg. Med. 29 3 (2001) 205-212
    • (2001) Laser Surg. Med. , vol.29 , Issue.3 , pp. 205-212
    • Ritz, J.P.1    Roggan, A.2    Isbert, C.3    Muller, G.4    Buhr, H.J.5    Germer, C.T.6
  • 25
    • 0032633751 scopus 로고    scopus 로고
    • Optical spectroscopic method for in vivo measurement of cardiac myoglobin oxygen saturation
    • Schenkman K.A., Marble D.R., Burns D.H., and Feigl E.O. Optical spectroscopic method for in vivo measurement of cardiac myoglobin oxygen saturation. Appl. Spectrosc. 53 3 (1999) 332-338
    • (1999) Appl. Spectrosc. , vol.53 , Issue.3 , pp. 332-338
    • Schenkman, K.A.1    Marble, D.R.2    Burns, D.H.3    Feigl, E.O.4
  • 26
    • 0032669888 scopus 로고    scopus 로고
    • Near-infrared spectroscopic measurement of myoglobin oxygen saturation in the presence of hemoglobin using partial least-squares analysis
    • Schenkman K.A., Marble D.R., Feigl E.O., and Burns D.H. Near-infrared spectroscopic measurement of myoglobin oxygen saturation in the presence of hemoglobin using partial least-squares analysis. Appl. Spectrosc. 53 3 (1999) 325-331
    • (1999) Appl. Spectrosc. , vol.53 , Issue.3 , pp. 325-331
    • Schenkman, K.A.1    Marble, D.R.2    Feigl, E.O.3    Burns, D.H.4
  • 28
    • 0003284061 scopus 로고    scopus 로고
    • Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations
    • Serov A., Steenbergen W., and de Mul F. Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations. J. Opt. Soc. Am. 18 3 (2001) 622-630
    • (2001) J. Opt. Soc. Am. , vol.18 , Issue.3 , pp. 622-630
    • Serov, A.1    Steenbergen, W.2    de Mul, F.3
  • 29
    • 0031711208 scopus 로고    scopus 로고
    • Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique
    • Simpson C.R., Kohl M., Essenpreis M., and Cope M. Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys. Med. Biol. 43 9 (1998) 2465-2478
    • (1998) Phys. Med. Biol. , vol.43 , Issue.9 , pp. 2465-2478
    • Simpson, C.R.1    Kohl, M.2    Essenpreis, M.3    Cope, M.4
  • 31
    • 0032826380 scopus 로고    scopus 로고
    • Red and green laser Doppler compared with capillary microscopy to assess skin microcirculation in the feet of healthy subjects
    • Tulevski I.I., Ubbink D.T., and Jacobs M.J.H.M. Red and green laser Doppler compared with capillary microscopy to assess skin microcirculation in the feet of healthy subjects. Microvasc. Res. 58 2 (1999) 83-88
    • (1999) Microvasc. Res. , vol.58 , Issue.2 , pp. 83-88
    • Tulevski, I.I.1    Ubbink, D.T.2    Jacobs, M.J.H.M.3
  • 33
    • 0037150460 scopus 로고    scopus 로고
    • Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range
    • Yaroslavsky A.N., Schulze P.C., Yaroslavsky I.V., Schober R., Ulrich F., and Schwarzmaier H.J. Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range. Phys. Med. Biol. 47 12 (2002) 2059-2073
    • (2002) Phys. Med. Biol. , vol.47 , Issue.12 , pp. 2059-2073
    • Yaroslavsky, A.N.1    Schulze, P.C.2    Yaroslavsky, I.V.3    Schober, R.4    Ulrich, F.5    Schwarzmaier, H.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.