메뉴 건너뛰기




Volumn 22, Issue 4, 2011, Pages

Needle-type environmental microsensors: Design, construction and uses of microelectrodes and multi-analyte MEMS sensor arrays

Author keywords

biofilm; chlorine type microelectrode; dissolved oxygen; environmental microsensor; flocs; free chlorine; ion selective microelectrode; microelectrode; microelectrode array; microelectromechanical systems; microprofiles; monochloramine; oxidation reduction potential; pH; phosphate

Indexed keywords

BIOFILMS; CHLORINE; DISSOLVED OXYGEN; ELECTRODES; ELECTROMECHANICAL DEVICES; MEMS; MICROELECTRODES; MICROMECHANICS; MICROSENSORS; NEEDLES; PH; PH EFFECTS; PHOSPHATES; REDOX REACTIONS;

EID: 79952774418     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/22/4/042001     Document Type: Review
Times cited : (39)

References (106)
  • 2
    • 0036025195 scopus 로고    scopus 로고
    • Structure and function of nitrifying biofilms as determined by molecular techniques and the use of microelectrodes
    • Okabe S, Naitoh H, Satoh H and Watanabe Y 2002 Structure and function of nitrifying biofilms as determined by molecular techniques and the use of microelectrodes Water Sci. Technol. 46 233-41 (Pubitemid 34975598)
    • (2002) Water Science and Technology , vol.46 , Issue.1-2 , pp. 233-241
    • Okabe, S.1    Naitoh, H.2    Satoh, H.3    Watanabe, Y.4
  • 3
  • 4
    • 0028098743 scopus 로고
    • An inhibition study of the effect of azo dyes on bioactivity of biofilms
    • Fu Y C, Jiang H and Bishop P L 1994 An inhibition study of the effect of azo dyes on bioactivity of biofilms Water Sci. Technol. 29 365-72 (Pubitemid 24301100)
    • (1994) Water Science and Technology , vol.29 , Issue.7 , pp. 365-372
    • Fu, Y.-C.1    Jiang, H.2    Bishop, P.3
  • 7
    • 0033057297 scopus 로고    scopus 로고
    • A microelectrode study of redox potential change in biofilms
    • DOI 10.1016/S0273-1223(99)00166-3, PII S0273122399001663
    • Bishop P L and Yu T 1999 A microelectrode study of redox potential change in biofilms Water Sci. Technol. 39 179-85 (Pubitemid 29243601)
    • (1999) Water Science and Technology , vol.39 , Issue.7 , pp. 179-185
    • Bishop, P.L.1    Yu, T.2
  • 8
    • 0027476683 scopus 로고
    • Microelectrode measurements of the activity distribution in nitrifying bacterial aggregates
    • de Beer D, Van Den Heuvel J C and Ottengraf S P P 1993 Microelectrode measurements of the activity distribution in nitrifying bacterial aggregates Appl. Environ. Microbiol. 59 573-9 (Pubitemid 23058952)
    • (1993) Applied and Environmental Microbiology , vol.59 , Issue.2 , pp. 573-579
    • De Beer, D.1    Van Den Heuvel, J.C.2    Ottengraf, S.P.P.3
  • 9
    • 0032486793 scopus 로고    scopus 로고
    • A review of experimental measurements of effective diffusive permeabilities and effective diffusion coefficients in biofilms
    • DOI 10.1002/(SICI)1097-0290(19980805)59:3<261::AID-BIT1>3.0.CO;2-9
    • Stewart P S 1998 A review of experimental measurements of effective diffusive permeabilities and effective diffusion coefficients in biofilms Biotechnol. Bioeng. 59 261-72 (Pubitemid 28298407)
    • (1998) Biotechnology and Bioengineering , vol.59 , Issue.3 , pp. 261-272
    • Stewart, P.S.1
  • 10
    • 0035723050 scopus 로고    scopus 로고
    • Biofilm penetration and disinfection efficacy of alkaline hypochlorite and chlorosulfamates
    • DOI 10.1046/j.1365-2672.2001.01413.x
    • Stewart P S, Rayner J, Roe F and Rees W M 2001 Biofilm penetration and disinfection efficacy of alkaline hypochlorite and chlorosulfamates J. Appl. Microbiol. 91 525-32 (Pubitemid 34205766)
    • (2001) Journal of Applied Microbiology , vol.91 , Issue.3 , pp. 525-532
    • Stewart, P.S.1    Rayner, J.2    Roe, F.3    Rees, W.M.4
  • 12
    • 0029379891 scopus 로고
    • Implications of reaction-diffusion theory for the disinfection of microbial biofilms by reactive antimicrobial agents
    • Stewart P S and Raquepas J B 1995 Implications of reaction-diffusion theory for the disinfection of microbial biofilms by reactive antimicrobial agents Chem. Eng. Sci. 50 3099-104
    • (1995) Chem. Eng. Sci. , vol.50 , Issue.19 , pp. 3099-3104
    • Stewart, P.S.1    Raquepas, J.B.2
  • 13
    • 0030569729 scopus 로고    scopus 로고
    • Transport limitation of chlorine disinfection of Pseudomonas aeruginosa entrapped in alginate beads
    • DOI 10.1002/(SICI)1097-0290(19960105)49:1<93::AID-BIT12>3.0.CO;2-C
    • Xu X, Stewart P S and Chen X 1996 Transport limitation of chlorine disinfection of Pseudomonas aeruginosa entrapped in alginate beads Biotechnol. Bioeng. 49 93-100 (Pubitemid 26001495)
    • (1996) Biotechnology and Bioengineering , vol.49 , Issue.1 , pp. 93-100
    • Xu, X.1    Stewart, P.S.2    Chen, X.3
  • 14
    • 77949305386 scopus 로고    scopus 로고
    • Characterization and application of a chlorine microelectrode for measuring monochloramine within a biofilm
    • Lee W H, Pressman J G, Wahman D G and Bishop P L 2010 Characterization and application of a chlorine microelectrode for measuring monochloramine within a biofilm Sensors Actuators B 145 734-42
    • (2010) Sensors Actuators , vol.145 , Issue.2 , pp. 734-742
    • Lee, W.H.1    Pressman, J.G.2    Wahman, D.G.3    Bishop, P.L.4
  • 15
    • 79952742407 scopus 로고    scopus 로고
    • Lee W H 2009 Development and use of microelectrodes to evaluate nitrification within chloraminated drinking water system biofilms, the effect of phosphate as a corrosion inhibitor on nitrifying biofilm PhD Dissertation University of Cincinnati, OH
    • (2009) PhD Dissertation
    • Lee, W.H.1
  • 16
    • 79951606299 scopus 로고    scopus 로고
    • Free chlorine and monochloramine application to nitrifying biofilm: Comparison of biofilm penetration, activity, and viability
    • Lee W H, Wahman D G, Bishop P L and Pressman J G 2011 Free chlorine and monochloramine application to nitrifying biofilm: comparison of biofilm penetration, activity, and viability Environ. Sci. Technol. 45 1412-9
    • (2011) Environ. Sci. Technol. , vol.45 , Issue.4 , pp. 1412-1419
    • Lee, W.H.1    Wahman, D.G.2    Bishop, P.L.3    Pressman, J.G.4
  • 19
    • 35748934480 scopus 로고    scopus 로고
    • Needle-type dissolved oxygen microelectrode array sensors for in situ measurements
    • DOI 10.1016/j.snb.2007.06.008, PII S0925400507004030
    • Lee J-H, Lim T-S, Seo Y, Bishop P L and Papautsky I 2007 Needle-type dissolved oxygen microelectrode array sensors for in situ measurements Sensors Actuators B 128 179-85 (Pubitemid 350051806)
    • (2007) Sensors and Actuators, B: Chemical , vol.128 , Issue.1 , pp. 179-185
    • Lee, J.-H.1    Lim, T.-S.2    Seo, Y.3    Bishop, P.L.4    Papautsky, I.5
  • 20
    • 36249022063 scopus 로고    scopus 로고
    • MEMS needle-type sensor array for in situ measurements of dissolved oxygen and redox potential
    • DOI 10.1021/es070969o
    • Lee J-H, Seo Y, Lim T-S, Bishop P L and Papautsky I 2007 MEMS Needle-type sensor array for in situ measurements of dissolved oxygen and redox potential Environ. Sci. Technol. 41 7857-63 (Pubitemid 350133329)
    • (2007) Environmental Science and Technology , vol.41 , Issue.22 , pp. 7857-7863
    • Lee, J.-H.1    Seo, Y.2    Lim, T.-S.3    Bishop, P.L.4    Papautsky, I.5
  • 21
    • 61849156391 scopus 로고    scopus 로고
    • Cobalt coated needle-type microelectrode array sensor for in situ monitoring of phosphate
    • Lee J-H, Lee W H, Bishop P L and Papautsky I 2009 Cobalt coated needle-type microelectrode array sensor for in situ monitoring of phosphate J. Micromech. Microeng. 19 025022
    • (2009) J. Micromech. Microeng. , vol.19 , Issue.2 , pp. 025022
    • Lee, J.-H.1    Lee, W.H.2    Bishop, P.L.3    Papautsky, I.4
  • 22
    • 74549138001 scopus 로고    scopus 로고
    • Biologicalapplication of MEMS microelectrode array sensors for direct measurement of phosphate in the enhanced biological phosphorous removal process
    • Lee W H, Lee J-H, Bishop P L and Papautsky I 2009 Biologicalapplication of MEMS microelectrode array sensors for direct measurement of phosphate in the enhanced biological phosphorous removal process Water Environ. Res. 81 748-54
    • (2009) Water Environ. Res. , vol.81 , Issue.8 , pp. 748-754
    • Lee, W.H.1    Lee, J.-H.2    Bishop, P.L.3    Papautsky, I.4
  • 23
    • 1142291661 scopus 로고    scopus 로고
    • Micromachined arrays of cantilevered glass probes
    • Srinivasan P, Beyette F R and Papautsky I 2004 Micromachined arrays of cantilevered glass probes Appl. Opt. 43 776-82
    • (2004) Appl. Opt. , vol.43 , Issue.4 , pp. 776-782
    • Srinivasan, P.1    Beyette, F.R.2    Papautsky, I.3
  • 25
    • 0025919031 scopus 로고
    • Oxidation-reduction capacities of aquifer solids
    • Barcelona M J and Holm T R 1991 Oxidation-reduction capacities of aquifer solids Environ. Sci. Technol. 25 1565-72
    • (1991) Environ. Sci. Technol. , vol.25 , Issue.9 , pp. 1565-1572
    • Barcelona, M.J.1    Holm, T.R.2
  • 26
    • 0027954956 scopus 로고
    • A review of the current understanding of redox capacity in natural, disequilibrium systems
    • DOI 10.1016/0045-6535(94)90303-4
    • Grundl T 1994 A review of the current understanding of redox capacity in natural, disequilibrium systems Chemosphere 28 613-26 (Pubitemid 24060641)
    • (1994) Chemosphere , vol.28 , Issue.3 , pp. 613-626
    • Grundl, T.1
  • 27
    • 0021639784 scopus 로고
    • Ground water redox reactions: An analysis of equilibrium state applied to Eh measurements and geochemical modeling
    • Lindberg R D and Runnells D D 1984 Ground water redox reactions: an analysis of equilibrium state applied to Eh measurements and geochemical modeling Science 225 925-7
    • (1984) Science , vol.225 , Issue.4665 , pp. 925-927
    • Lindberg, R.D.1    Runnells, D.D.2
  • 28
    • 24344445525 scopus 로고    scopus 로고
    • Measure of disinfection effectiveness for chlorination of wastewater
    • Bergendahl H A and Stevens L 2005 Measure of disinfection effectiveness for chlorination of wastewater Environ. Prog. 24 214-22
    • (2005) Environ. Prog. , vol.24 , Issue.2 , pp. 214-222
    • Bergendahl, H.A.1    Stevens, L.2
  • 29
    • 0037192012 scopus 로고    scopus 로고
    • Application of oxidation-reduction potential as a controlling parameter in waste activated sludge hydrolysis
    • Change C N and Ma Y S 2002 Application of oxidation-reduction potential as a controlling parameter in waste activated sludge hydrolysis Chem. Eng. 90 273-81
    • (2002) Chem. Eng. , vol.90 , Issue.3 , pp. 273-281
    • Change, C.N.1    Ma, Y.S.2
  • 30
    • 23944526815 scopus 로고    scopus 로고
    • Simultaneous estimation of sludge biological activity and influent nitrogen load using ORP and DO dynamics
    • DOI 10.1007/s00449-005-0411-7
    • Queinnee I and Sperandio M 2005 Simultaneous estimation of sludge biological activity and influent nitrogen load using ORP and DO dynamics Bioprocess Biosyst. Eng. 27 329-37 (Pubitemid 41207024)
    • (2005) Bioprocess and Biosystems Engineering , vol.27 , Issue.5 , pp. 329-337
    • Queinnec, I.1    Sperandio, M.2
  • 31
    • 0032533699 scopus 로고    scopus 로고
    • Fabrication of redox potential microelectrodes for studies in vegetated soils or biofilm systems
    • Pang H and Zhang T C 1998 Fabrication of redox potential microelectrodes for studies in vegetated soils or biofilm systems Environ. Sci. Technol. 32 3646-53
    • (1998) Environ. Sci. Technol. , vol.32 , Issue.22 , pp. 3646-3653
    • Pang, H.1    Zhang, T.C.2
  • 34
    • 0031804537 scopus 로고    scopus 로고
    • Stratification of microbial metabolic processes and redox potential change in sulfate-reducing biofilms studied using oxygen, sulfide, pH and redox potential microelectrodes
    • Yu T and Bishop P L 1998 Stratification of microbial metabolic processes and redox potential change in sulfate-reducing biofilms studied using oxygen, sulfide, pH and redox potential microelectrodes Water Sci. Technol. 37 195-8
    • (1998) Water Sci. Technol. , vol.37 , Issue.4-5 , pp. 195-198
    • Yu, T.1    Bishop, P.L.2
  • 35
    • 1242295314 scopus 로고    scopus 로고
    • Micro-profiles of activated sludge floc determined using microelectrodes
    • DOI 10.1016/j.watres.2003.11.019
    • Li B and Bishop P L 2004a Micro-profiles of activated sludge floc determined using microelectrodes Water Res. 38 1248-58 (Pubitemid 38229365)
    • (2004) Water Research , vol.38 , Issue.5 , pp. 1248-1258
    • Li, B.1    Bishop, P.L.2
  • 36
    • 13244255197 scopus 로고    scopus 로고
    • Time course observations of nitrifying biofilm development using microelectrodes
    • DOI 10.1139/S04-027
    • Li J and Bishop P L 2004 Time course observations of nitrifying biofilm development using microelectrodes J. Environ. Eng. Sci. 3 523-8 (Pubitemid 40184345)
    • (2004) Journal of Environmental Engineering and Science , vol.3 , Issue.6 , pp. 523-528
    • Li, J.1    Bishop, P.L.2
  • 37
    • 16544387755 scopus 로고    scopus 로고
    • Oxidation-reduction potential changes in aeration tanks and microprofiles of activated sludge floc in medium- and low-strength wastewaters
    • DOI 10.2175/106143004X151662
    • Li B and Bishop P L 2004b Oxidation-reduction potential changes in aeration tanks and microprofiles of activated sludge floc in medium- and low-strength wastewaters Water Environ. Res. 76 394-403 (Pubitemid 40684512)
    • (2004) Water Environment Research , vol.76 , Issue.5 , pp. 394-403
    • Li, B.1    Bishop, P.L.2
  • 39
    • 33947709980 scopus 로고    scopus 로고
    • A parylene-protected nitrate selective microsensor on a carbon fiber cross section
    • DOI 10.1016/j.snb.2006.08.007, PII S0925400506005351
    • Bendikova T A, Miserendinob S, Taib Y-C and Harmon T C 2007 A parylene-protected nitrate selective microsensor on a carbon fiber cross section Sensors Actuators B 123 127-34 (Pubitemid 46497682)
    • (2007) Sensors and Actuators, B: Chemical , vol.123 , Issue.1 , pp. 127-134
    • Bendikov, T.A.1    Miserendino, S.2    Tai, Y.-C.3    Harmon, T.C.4
  • 40
    • 34249021314 scopus 로고    scopus 로고
    • Wetting and electrowetting properties of carbon nanotube templated parylene films
    • DOI 10.1021/jp071501a
    • Wang Z, Ou Y, Lu T-M and Koratkar N 2007 Wetting and electrowetting properties of carbon nanotube templated parylene films J. Phys. Chem. B 111 4296-9 (Pubitemid 46787621)
    • (2007) Journal of Physical Chemistry B , vol.111 , Issue.17 , pp. 4296-4299
    • Wang, Z.1    Ou, Y.2    Lu, T.-M.3    Koratkar, N.4
  • 46
    • 0037112546 scopus 로고    scopus 로고
    • Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies
    • DOI 10.1021/ac020326l
    • Bezbaruah A N and Zhang T C 2002 Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies Anal. Chem. 74 5726-33 (Pubitemid 35364826)
    • (2002) Analytical Chemistry , vol.74 , Issue.22 , pp. 5726-5733
    • Bezbaruah, A.N.1    Zhang, T.C.2
  • 47
    • 0037444614 scopus 로고    scopus 로고
    • Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates
    • DOI 10.1021/ac0261404
    • Marzouk S A M 2003 Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates Anal. Chem. 75 1258-66 (Pubitemid 36397156)
    • (2003) Analytical Chemistry , vol.75 , Issue.6 , pp. 1258-1266
    • Marzouk, S.A.M.1
  • 48
    • 0032400890 scopus 로고    scopus 로고
    • Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia
    • Marzouk S A M, Ufer S, Buck R P, Johnson T A, Dunlap L A and Cascio W E 1998 Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia Anal. Chem. 70 5054-61
    • (1998) Anal. Chem. , vol.70 , Issue.23 , pp. 5054-5061
    • Marzouk, S.A.M.1    Ufer, S.2    Buck, R.P.3    Johnson, T.A.4    Dunlap, L.A.5    Cascio, W.E.6
  • 49
    • 0037021770 scopus 로고    scopus 로고
    • A long-term stable iridium oxide pH electrode
    • DOI 10.1016/S0925-4005(01)00972-8, PII S0925400501009728
    • Wang M, Yao S and Madou M 2002 A long-term stable iridium oxide pH electrode Sensors Actuators B 81 313-5 (Pubitemid 33149438)
    • (2002) Sensors and Actuators, B: Chemical , vol.81 , Issue.2-3 , pp. 313-315
    • Wang, M.1    Yao, S.2    Madou, M.3
  • 52
    • 0032976059 scopus 로고    scopus 로고
    • In situ analysis of nitrifying biofilms as determined by in situ hybridization and the use of microelectrodes
    • Okabe S, Satoh H and Watanabe Y 1999 In situ analysis of nitrifying biofilms as determined by in situ hybridization and the use of microelectrodes Appl. Environ. Microbiol. 65 3182-91 (Pubitemid 29315597)
    • (1999) Applied and Environmental Microbiology , vol.65 , Issue.7 , pp. 3182-3191
    • Okabe, S.1    Satoh, H.2    Watanabe, Y.3
  • 54
    • 0000224938 scopus 로고
    • Microelectrodes: Their use in microbial ecology
    • Revsbech N P and Jørgensen B B 1986 Microelectrodes: their use in microbial ecology Adv. Microb. Ecol. 9 293-352
    • (1986) Adv. Microb. Ecol. , vol.9 , pp. 293-352
    • Revsbech, N.P.1    Jørgensen, B.B.2
  • 55
    • 84986767568 scopus 로고
    • An oxygen microsensor with a guard cathode
    • Revsbech N P 1989 An oxygen microsensor with a guard cathode Limnol. Oceanogr. 34 474-8
    • (1989) Limnol. Oceanogr. , vol.34 , Issue.2 , pp. 474-478
    • Revsbech, N.P.1
  • 56
    • 1642455003 scopus 로고    scopus 로고
    • Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science
    • Lu R and Yu T 2002 Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science J. Environ. Eng. Sci. 1 225-35
    • (2002) J. Environ. Eng. Sci. , vol.1 , Issue.3 , pp. 225-235
    • Lu, R.1    Yu, T.2
  • 57
    • 29244441666 scopus 로고    scopus 로고
    • Development of an automation system to evaluate the three-dimensional oxygen distribution in wastewater biofilms using microsensors
    • DOI 10.1016/j.snb.2005.02.025, PII S0925400505002054
    • de la Rosa C and Yu T 2006 Development of an automatic system to evaluate the three-dimensional oxygen distribution in wastewater biofilms using microsensors Sensors Actuators B 113 47-54 (Pubitemid 41831268)
    • (2006) Sensors and Actuators, B: Chemical , vol.113 , Issue.1 , pp. 47-54
    • De La Rosa, C.1    Yu, T.2
  • 58
    • 67949110964 scopus 로고    scopus 로고
    • Effects of recess dimensions on performance of the recessed cathode dissolved oxygen sensor
    • Lim T-S, Lee J-H and Papautsky I 2009 Effects of recess dimensions on performance of the recessed cathode dissolved oxygen sensor Sensors Actuators B 141 50-7
    • (2009) Sensors Actuators , vol.141 , Issue.1 , pp. 50-57
    • Lim, T.-S.1    Lee, J.-H.2    Papautsky, I.3
  • 59
    • 0030176650 scopus 로고    scopus 로고
    • Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate
    • Meruva R K and Meyerhoff M E 1996 Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate Anal. Chem. 68 2022-6
    • (1996) Anal. Chem. , vol.68 , Issue.13 , pp. 2022-2026
    • Meruva, R.K.1    Meyerhoff, M.E.2
  • 60
    • 0032532455 scopus 로고    scopus 로고
    • The phosphate sensor
    • DOI 10.1016/S0956-5663(98)00001-3, PII S0956566398000013
    • Engblom S O 1998 The phosphate sensor Biosens. Bioelectron. 13 981-94 (Pubitemid 28506009)
    • (1998) Biosensors and Bioelectronics , vol.13 , Issue.9 , pp. 981-994
    • Engblom, S.O.1
  • 62
    • 0024428859 scopus 로고
    • Determination of inorganic phosphate by flow injection method with immobilized enzymes and chemiluminescence detection
    • Kawasaki H, Sato K, Ogawa J, Hasegawa Y and Yuki H 1989 Determination of inorganic phosphate by flow injection method with immobilized enzymes and chemiluminescence detection Anal. Biochem. 182 366-70 (Pubitemid 19277119)
    • (1989) Analytical Biochemistry , vol.182 , Issue.2 , pp. 366-370
    • Kawasaki, H.1    Sato, K.2    Ogawa, J.3    Hasegawa, Y.4    Yuki, H.5
  • 63
    • 0001207411 scopus 로고
    • Problem in the analysis of phosphorus compounds
    • Burton J D 1973 Problem in the analysis of phosphorus compounds Water Res. 7 291-307
    • (1973) Water Res. , vol.7 , Issue.1-2 , pp. 291-307
    • Burton, J.D.1
  • 64
    • 0024364564 scopus 로고
    • Phosphate ion-sensitive coated-wire/field-effect transistor electrode based on cobalt phthalocyanine with poly(vinyl chloride) as the membrane matrix
    • DOI 10.1016/S0003-2670(00)83455-8
    • Liu J, Masuda Y, Sekido E, Wakida S-I and Hiiro K 1989 Phosphate ion-selective coated-wire/field-effect transistor electrode based on cobalt phthlocyanine with poly(vinyl chloride) as the membrane matrix Anal. Chim. Acta 224 145-51 (Pubitemid 19209870)
    • (1989) Analytica Chimica Acta , vol.224 , Issue.1 , pp. 145-151
    • Liu, J.1    Masuda, Y.2    Sekido, E.3    Wakida, S.4    Hiiro, K.5
  • 65
    • 0024106444 scopus 로고
    • Phosphate-selective polymer membrane electrode
    • Glazier S A and Arnold M A 1988 Phosphate-selective polymer membrane electrode Anal. Chem. 60 2540-2
    • (1988) Anal. Chem. , vol.60 , Issue.22 , pp. 2540-2542
    • Glazier, S.A.1    Arnold, M.A.2
  • 66
    • 0031579480 scopus 로고    scopus 로고
    • Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound
    • DOI 10.1016/S0003-2670(96)00382-0, PII S0003267096003820
    • Liu D, Chen W-C, Yang R-H, Shen G-L and Yu R-O 1997 Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound Anal. Chim. Acta 228 209-14 (Pubitemid 27083678)
    • (1997) Analytica Chimica Acta , vol.338 , Issue.3 , pp. 209-214
    • Liu, D.1    Chen, W.-C.2    Yang, R.-H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 67
    • 0001264503 scopus 로고
    • Dialkyltin salts as extractants in methods for the determination of arsenic and phosphorus
    • Shkinev V M, Spivakov B Y, Vorob'eva G A and Zolotov Y A 1985 Dialkyltin salts as extractants in methods for the determination of arsenic and phosphorus Anal. Chim. Acta 167 145-60
    • (1985) Anal. Chim. Acta , vol.167 , pp. 145-160
    • Shkinev, V.M.1    Spivakov, B.Y.2    Vorob'Eva, G.A.3    Zolotov, Y.A.4
  • 70
    • 21344483680 scopus 로고
    • Behavior of silver orthophosphate as the electroactive sensor of a coated, tubular solid-state phosphate-selective electrode in flow-injection analysis
    • van Staden J F 1993 Behavior of silver orthophosphate as the electroactive sensor of a coated, tubular solid-state phosphate-selective electrode in flow-injection analysis South Afr. J. Chem. 46 14-9
    • (1993) South Afr. J. Chem. , vol.46 , pp. 14-19
    • Van Staden, J.F.1
  • 71
    • 0039907244 scopus 로고    scopus 로고
    • Flow-injection Potentiometric Detection of Phosphates Using a Metallic Cobalt Wire Ion-selective Electrode
    • Chen Z, De Marco R and Alexander P W 1997 Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode Anal. Commun. 34 93-5 (Pubitemid 127481216)
    • (1997) Analytical Communications , vol.34 , Issue.3 , pp. 93-95
    • Chen, Z.1    De Marco, R.2    Alexander, P.W.3
  • 72
    • 19944395204 scopus 로고    scopus 로고
    • Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (EBPR) process
    • Wang J and Bishop P L 2005 Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (EBPR) process Environ. Technol. 26 381-8 (Pubitemid 40753952)
    • (2005) Environmental Technology , vol.26 , Issue.4 , pp. 381-388
    • Wang, J.J.1    Bishop, P.L.2
  • 73
    • 0001649268 scopus 로고
    • Surface-modified cobalt-based sensor as a phosphate-sensitive electrode
    • Xiao D, Yuan H Y, Li J and Yu R Q 1995 Surface-modified cobalt-based sensor as a phosphate-sensitive electrode Anal. Chem. 67 288-91
    • (1995) Anal. Chem. , vol.67 , Issue.2 , pp. 288-291
    • Xiao, D.1    Yuan, H.Y.2    Li, J.3    Yu, R.Q.4
  • 74
    • 0025784569 scopus 로고
    • A FIA biosensor system for the determination of phosphate
    • Male K B and Luong J H T 1991 A FIA biosensor system for the determination of phosphate Biosens. Bioelectron. 6 581-7
    • (1991) Biosens. Bioelectron. , vol.6 , Issue.7 , pp. 581-587
    • Male, K.B.1    Luong, J.H.T.2
  • 75
    • 0023521664 scopus 로고
    • Determination of phosphate ions with an enzyme sensor system
    • Watanabe E, Endo H and Toyama K 1988 Determination of phosphate ions with an enzyme sensor system Biosensors 3 297-306
    • (1988) Biosensors , vol.3 , Issue.5 , pp. 297-306
    • Watanabe, E.1    Endo, H.2    Toyama, K.3
  • 76
    • 60549083081 scopus 로고    scopus 로고
    • Cobalt-based phosphate microelectrode for in-situ environmental analysis
    • Lee W H, Seo Y and Bishop P L 2009 Cobalt-based phosphate microelectrode for in-situ environmental analysis Sensors Actuators B 137 121-8
    • (2009) Sensors Actuators , vol.137 , Issue.1 , pp. 121-128
    • Lee, W.H.1    Seo, Y.2    Bishop, P.L.3
  • 77
    • 77956295836 scopus 로고    scopus 로고
    • In-situ microscale analyses of activated sludge flocs in the enhanced biological phosphate removal process by the use of microelectrodes and fluorescent in-situ hybridization
    • Lee W H and Bishop P L 2010 In-situ microscale analyses of activated sludge flocs in the enhanced biological phosphate removal process by the use of microelectrodes and fluorescent in-situ hybridization J. Environ. Eng.-ASCE 136 561-7
    • (2010) J. Environ. Eng.-ASCE , vol.136 , Issue.6 , pp. 561-567
    • Lee, W.H.1    Bishop, P.L.2
  • 78
    • 0031807256 scopus 로고    scopus 로고
    • Direct determination of phosphate in soil extracts by potentiometric flow injection using a cobalt wire electrode
    • DOI 10.1016/S0003-2670(98)00137-8, PII S0003267098001378
    • Chen Z, Grierson P and Adams M A 1998 Direct determination of phosphate in soil extracts by potentiometric flow injection using a cobalt wire electrode Anal. Chim. Acta 363 191-7 (Pubitemid 28276998)
    • (1998) Analytica Chimica Acta , vol.363 , Issue.2-3 , pp. 191-197
    • Chen, Z.1    Grierson, P.2    Adams, M.A.3
  • 79
    • 0041423781 scopus 로고    scopus 로고
    • Determination of phosphate in hydroponic nutrient solutions using flow injection potentiometry and a cobalt-wire phosphate ion-selective electrode
    • Marco R D and Phan C 2003 Determination of phosphate in hydroponic nutrient solutions using flow injection potentiometry and a cobalt-wire phosphate ion-selective electrode Talanta 60 1215-21
    • (2003) Talanta , vol.60 , Issue.6 , pp. 1215-1221
    • Marco, R.D.1    Phan, C.2
  • 82
    • 33847415823 scopus 로고    scopus 로고
    • A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate
    • DOI 10.1016/j.bios.2006.08.004, PII S0956566306003708, Selected Papers from the Ninth World Congress On Biosensors
    • Zou Z, Han J, Jang A, Bishop P L and Ahn C H 2007 A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate Biosens. Bioelectron. 22 1902-7 (Pubitemid 46349622)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 1902-1907
    • Zou, Z.1    Han, J.2    Jang, A.3    Bishop, P.L.4    Ahn, C.H.5
  • 84
    • 0028037497 scopus 로고
    • Direct measurement of chlorine penetration into biofilms during disinfection
    • de Beer D, Srinivasan R and Stewart P S 1994 Direct measurement of chlorine penetration into biofilms during disinfection Appl. Environ. Microbiol. 60 4339-44 (Pubitemid 24370800)
    • (1994) Applied and Environmental Microbiology , vol.60 , Issue.12 , pp. 4339-4344
    • De Beer, D.1    Srinivasan, R.2    Stewart, P.S.3
  • 85
    • 33747470667 scopus 로고    scopus 로고
    • Persistence of Klebsiella pneumoniae on simulated biofilm in a model drinking water system
    • DOI 10.1021/es060857h
    • Szabo J G, Rice E W and Bishop P L 2006 Persistence of Klebsiella pneumonia on simulated biofilm in a model drinking water system Environ. Sci. Technol. 40 4996-5002 (Pubitemid 44257464)
    • (2006) Environmental Science and Technology , vol.40 , Issue.16 , pp. 4996-5002
    • Szabo, J.G.1    Rice, E.W.2    Bishop, P.L.3
  • 86
    • 33747501199 scopus 로고    scopus 로고
    • Measurement of chlorine dioxide penetration in dairy process pipe biofilms during disinfection
    • DOI 10.1007/s00253-005-0274-5
    • Jang A, Szabo J, Hosni A A, Coughlin M and Bishop P L 2006 Measurement of chlorine dioxide penetration in dairy process pipe biofilms during disinfection Appl. Microbiol. Biotechnol. 72 368-76 (Pubitemid 44273061)
    • (2006) Applied Microbiology and Biotechnology , vol.72 , Issue.2 , pp. 368-376
    • Jang, A.1    Szabo, J.2    Hosni, A.A.3    Coughlin, M.4    Bishop, P.L.5
  • 88
  • 89
    • 4243852893 scopus 로고    scopus 로고
    • New drinking water hazard
    • Betts K S 2002 New drinking water hazard Environ. Sci. Technol. 36 92A-3A
    • (2002) Environ. Sci. Technol. , vol.36 , Issue.5
    • Betts, K.S.1
  • 92
    • 0025055160 scopus 로고
    • Ammonia-oxidizing bacteria in a chloraminated distribution sytem: Seasonal occurrence, distribution, and disinfection resistance
    • Wolfe R L, Lieu N I, Izaguirre G and Means E G 1990 Ammonia-oxidizing bacteria in a chloraminated distribution system: seasonal occurrence, distribution, and disinfection resistance Appl. Environ. Microbiol. 56 451-62 (Pubitemid 20055320)
    • (1990) Applied and Environmental Microbiology , vol.56 , Issue.2 , pp. 451-462
    • Wolfe, R.L.1    Lieu, N.I.2    Izaguirre, G.3    Means, E.G.4
  • 94
    • 0026603689 scopus 로고
    • Reaction scheme for the chlorination of ammoniacal water
    • Jafvert C T and Valentine R L 1992 Reaction scheme for the chlorination of ammoniacal water Environ. Sci. Technol. 26 577-86
    • (1992) Environ. Sci. Technol. , vol.26 , Issue.3 , pp. 577-586
    • Jafvert, C.T.1    Valentine, R.L.2
  • 95
    • 0035090801 scopus 로고    scopus 로고
    • Monochloramine decay in model and distribution system waters
    • DOI 10.1016/S0043-1354(00)00406-1, PII S0043135400004061
    • Vikesland P J, Ozekin K and Valentine R L 2001 Monochloramine decay in model and distribution system waters Water Res. 35 1766-76 (Pubitemid 32201486)
    • (2001) Water Research , vol.35 , Issue.7 , pp. 1766-1776
    • Vikesland, P.J.1    Ozekin, K.2    Valentine, R.L.3
  • 96
    • 0033579998 scopus 로고    scopus 로고
    • A net-jet flow system for mass transfer and microsensor studies of sinking aggregates
    • Ploug H and Jorgensen B B 1999 A net-jet flow system for mass transfer and microsensor studies of sinking aggregates Mar. Ecol. Prog. 176 279-99
    • (1999) Mar. Ecol. Prog. , vol.176 , pp. 279-299
    • Ploug, H.1    Jorgensen, B.B.2
  • 97
    • 0032812283 scopus 로고    scopus 로고
    • Microscale distribution of populations and activities of Nitrosospira and Nitrospira spp. along a macroscale gradient in a nitrifying bioreactor: Quantification by in situ hybridization and the use of microsensors
    • Schramm A, de Beer D, Van Den Heuvel J C, Ottengraf S and Aman R 1999 Microscale distribution of populations and activities of nitrosospira and nitrospira spp. along a macroscale gradient in a nitrifying bioreactor: quantification by in situ hybridization and the use of microsensors Appl. Environ. Microbiol. 65 3690-6 (Pubitemid 29399004)
    • (1999) Applied and Environmental Microbiology , vol.65 , Issue.8 , pp. 3690-3696
    • Schramm, A.1    De Beer, D.2    Van Den Heuvel, J.C.3    Ottengraf, S.4    Amann, R.5
  • 98
    • 27444447638 scopus 로고    scopus 로고
    • Simultaneous nitrogen and phosphorus removal using denitrifying phosphate-accumulating organisms in a sequencing batch reactor
    • Satoshi T, Takashi O, Koichi S and Akira H 2006 Simultaneous nitrogen and phosphorus removal using denitrifying phosphate-accumulating organisms in a sequencing batch reactor Biochem. Eng. J. 27 191-6
    • (2006) Biochem. Eng. J. , vol.27 , Issue.3 , pp. 191-196
    • Satoshi, T.1    Takashi, O.2    Koichi, S.3    Akira, H.4
  • 99
    • 0041665106 scopus 로고    scopus 로고
    • The competition between PAOs and GAOs in EBPR systems at different temperatures and the effects on system performance
    • Erdal U G, Erdal Z K and Randall C W 2003 The competition between PAOs and GAOs in EBPR systems at different temperatures and the effects on system performance Water Sci. Technol. 47 1-8
    • (2003) Water Sci. Technol. , vol.47 , pp. 1-8
    • Erdal, U.G.1    Erdal, Z.K.2    Randall, C.W.3
  • 100
    • 0023028385 scopus 로고
    • Biochemical model for enhanced biological phosphorus removal
    • Comeau Y, Hall K J, Hancock R E W and Oldham W K 1986 Biochemical model for enhanced biological phosphorus removal Water Res. 20 1511-22
    • (1986) Water Res. , vol.20 , Issue.12 , pp. 1511-1522
    • Comeau, Y.1    Hall, K.J.2    Hancock, R.E.W.3    Oldham, W.K.4
  • 101
    • 0030754145 scopus 로고    scopus 로고
    • Application of the IAWQ activated sludge model to nutrient removal process
    • DOI 10.1016/S0273-1223(97)00157-1, PII S0273122397001571
    • Mino T, San Pedro D C, Yamamoto S and Matsuo T 1997 Application of the IAWQ activated sludge model to nutrient removal process Water Sci. Technol. 35 111-8 (Pubitemid 27309625)
    • (1997) Water Science and Technology , vol.35 , Issue.8 , pp. 111-118
    • Mino, T.1    San Pedro, D.C.2    Yamamoto, S.3    Matsuo, T.4
  • 102
  • 104
    • 0024748314 scopus 로고
    • Biofilms and bacterial drinking water quality
    • DOI 10.1016/0043-1354(89)90193-0
    • Van Der Wende E, Characklis W G and Smith D B 1989 Biofilms and bacterial drinking water quality Water Res. 23 1313-22 (Pubitemid 19256935)
    • (1989) Water Research , vol.23 , Issue.10 , pp. 1313-1322
    • Van Der Wende, E.1    Characklis, W.G.2    Smith, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.