메뉴 건너뛰기




Volumn 19, Issue 2, 2009, Pages

A cobalt-coated needle-type microelectrode array sensor for in situ monitoring of phosphate

Author keywords

[No Author keywords available]

Indexed keywords

COBALT; COBALT COMPOUNDS; ELECTRIC CONNECTORS; MICROELECTRODES; NEEDLES; POTASSIUM; PRINTED CIRCUIT MANUFACTURE; SENSORS; SURFACE DEFECTS; THREE DIMENSIONAL;

EID: 61849156391     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/19/2/025022     Document Type: Article
Times cited : (33)

References (22)
  • 1
    • 0030176650 scopus 로고    scopus 로고
    • Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate
    • Meruva R K and Meyerhoff M E 1996 Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate Anal. Chem. 68 2022-6
    • (1996) Anal. Chem. , vol.68 , Issue.13 , pp. 2022-2026
    • Meruva, R.K.1    Meyerhoff, M.E.2
  • 2
    • 0032532455 scopus 로고    scopus 로고
    • The phosphate sensor
    • Engblom S O 1998 The phosphate sensor Biosens. Bioelectron. 13 981-94
    • (1998) Biosens. Bioelectron. , vol.13 , Issue.9 , pp. 981-994
    • Engblom, S.O.1
  • 3
    • 0001649268 scopus 로고
    • Surface-modified cobalt-based sensor as a phosphate-sensitive electrode
    • Xiao D, Yuan H-Y and Li J 1993 Surface-modified cobalt-based sensor as a phosphate-sensitive electrode Anal. Chem. 67 288-91
    • (1993) Anal. Chem. , vol.67 , Issue.2 , pp. 288-291
    • Xiao, D.1    Yuan, H.-Y.2    Li, J.3
  • 4
    • 0039907244 scopus 로고    scopus 로고
    • Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode
    • Chen Z, De Marco R and Alexander P W 1997 Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode Anal. Commun. 34 93-5
    • (1997) Anal. Commun. , vol.34 , Issue.3 , pp. 93-95
    • Chen, Z.1    De Marco, R.2    Alexander, P.W.3
  • 5
    • 19944395204 scopus 로고    scopus 로고
    • Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (EBPR) process
    • Wang J and Bishop P L 2005 Development of a phosphate ion-selective microelectrode and its use in studies of the enhanced biological phosphorus removal (EBPR) process Environ. Technol. 26 381-8
    • (2005) Environ. Technol. , vol.26 , Issue.4 , pp. 381-388
    • Wang, J.1    Bishop, P.L.2
  • 6
    • 0032433937 scopus 로고    scopus 로고
    • Determination of inorganic phosphate in a soil extract using a cobalt electrode
    • Engblom S O 1999 Determination of inorganic phosphate in a soil extract using a cobalt electrode Plant Soil 206 173-9
    • (1999) Plant Soil , vol.206 , Issue.2 , pp. 173-179
    • Engblom, S.O.1
  • 7
    • 0031847744 scopus 로고    scopus 로고
    • Flow injection potentiometric determination of phosphate in waste waters and fertilizers using a cobalt wire ion-selective electrode
    • De Marco R, Pejcic B and Chen Z 1998 Flow injection potentiometric determination of phosphate in waste waters and fertilizers using a cobalt wire ion-selective electrode Analyst 123 1635-40
    • (1998) Analyst , vol.123 , Issue.7 , pp. 1635-1640
    • De Marco, R.1    Pejcic, B.2    Chen, Z.3
  • 8
    • 0031807256 scopus 로고    scopus 로고
    • Direct determination of phosphate in soil extracts by potentiometric flow injection using a cobalt wire electrode
    • Chen Z, Grierson P and Adams M A 1998 Direct determination of phosphate in soil extracts by potentiometric flow injection using a cobalt wire electrode Anal. Chim. Acta 363 191-7
    • (1998) Anal. Chim. Acta , vol.363 , Issue.2-3 , pp. 191-197
    • Chen, Z.1    Grierson, P.2    Adams, M.A.3
  • 9
    • 0025784569 scopus 로고
    • An FIA biosensor system for the determination of phosphate
    • Male K B and Luong J H T 1991 An FIA biosensor system for the determination of phosphate Biosens. Bioelectron. 6 581-7
    • (1991) Biosens. Bioelectron. , vol.6 , Issue.7 , pp. 581-587
    • Male, K.B.1    Luong, J.H.T.2
  • 10
    • 0023521664 scopus 로고
    • Determination of phosphate ions with an enzyme sensors system
    • Watanabe E, Endo H and Toyama K 1988 Determination of phosphate ions with an enzyme sensors system Biosensors 3 297-306
    • (1988) Biosensors , vol.3 , Issue.5 , pp. 297-306
    • Watanabe, E.1    Endo, H.2    Toyama, K.3
  • 11
    • 19944412512 scopus 로고    scopus 로고
    • Biological phosphate ester sensing using an artificial enzyme PMP complex
    • Ikenoa S and Haruyama T 2005 Biological phosphate ester sensing using an artificial enzyme PMP complex Sensors Actuators B 108 608-12
    • (2005) Sensors Actuators , vol.108 , Issue.1-2 , pp. 608-612
    • Ikenoa, S.1    Haruyama, T.2
  • 12
    • 0001264503 scopus 로고
    • Dialkyltin salts as extractants in methods for the determination of arsenic and phosphorus
    • Shkinev V M, Spivakov B Y, Vorob'eva G A and Zolotov Y A 1985 Dialkyltin salts as extractants in methods for the determination of arsenic and phosphorus Anal. Chim. Acta 167 145-60
    • (1985) Anal. Chim. Acta , vol.167 , Issue.1 , pp. 145-160
    • Shkinev, V.M.1    Spivakov, B.Y.2    Vorob'Eva, G.A.3    Zolotov, Y.A.4
  • 13
    • 0024106444 scopus 로고
    • Phosphate-selective polymer membrane electrode
    • Glazier S A and Arnold M A 1988 Phosphate-selective polymer membrane electrode Anal. Chem. 60 2540-2
    • (1988) Anal. Chem. , vol.60 , Issue.22 , pp. 2540-2542
    • Glazier, S.A.1    Arnold, M.A.2
  • 14
    • 0031579480 scopus 로고    scopus 로고
    • Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound
    • Liu D, Chen W-C, Yang R-H, Shen G-L and Yu R-O 1997 Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound Anal. Chim. Acta 228 209-14
    • (1997) Anal. Chim. Acta , vol.338 , Issue.3 , pp. 209-214
    • Liu, D.1    Chen, W.-C.2    Yang, R.-H.3    Shen, G.-L.4    Yu, R.-O.5
  • 17
    • 21344483680 scopus 로고
    • Behavior of silver orthophosphate as the electroactive sensor of a coated, tubular solid-state phosphate-selective electrode in flow-injection analysis
    • Van Staden J F 1993 Behavior of silver orthophosphate as the electroactive sensor of a coated, tubular solid-state phosphate-selective electrode in flow-injection analysis South African J. Chem. 46 14-19
    • (1993) South African J. Chem. , vol.46 , pp. 14-19
    • Van Staden, J.F.1
  • 20
    • 35748934480 scopus 로고    scopus 로고
    • Needle-type dissolved oxygen microelectrode array sensors for in situ measurements
    • Lee J-H, Lim T-S, Seo Y, Bishop P L and Papautsky I 2007 Needle-type dissolved oxygen microelectrode array sensors for in situ measurements Sensors Actuators B 128 179-85
    • (2007) Sensors Actuators , vol.128 , Issue.1 , pp. 179-185
    • Lee, J.-H.1    Lim, T.-S.2    Seo, Y.3    Bishop, P.L.4    Papautsky, I.5
  • 21
    • 36249022063 scopus 로고    scopus 로고
    • Integrated microelectrode array sensor for in situ oxidation reduction potential and dissolved oxygen measurements
    • Lee J-H, Seo Y, Lim T-S, Bishop P L and Papautsky I 2007 Integrated microelectrode array sensor for in situ oxidation reduction potential and dissolved oxygen measurements Environ. Sci. Technol. 41 7857-63
    • (2007) Environ. Sci. Technol. , vol.41 , Issue.22 , pp. 7857-7863
    • Lee, J.-H.1    Seo, Y.2    Lim, T.-S.3    Bishop, P.L.4    Papautsky, I.5
  • 22
    • 1642455003 scopus 로고    scopus 로고
    • Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science
    • Lu R and Yu T 2002 Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science J. Environ. Eng. Sci. 1 225-35
    • (2002) J. Environ. Eng. Sci. , vol.1 , Issue.3 , pp. 225-235
    • Lu, R.1    Yu, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.