메뉴 건너뛰기




Volumn 65, Issue 3, 2011, Pages 802-811

Detecting blood-brain barrier disruption within minimal hemorrhage following transcranial focused ultrasound: A correlation study with contrast-enhanced MRI

Author keywords

blood brain barrier; focused ultrasound; magnetic resonance imaging; microbubbles; ultrasound contrast agent

Indexed keywords

BRAIN MAPPING; IMAGE ENHANCEMENT; MAGNETIC RESONANCE IMAGING; MAPPING; RELAXATION TIME; SPIN POLARIZATION; ULTRASONIC APPLICATIONS;

EID: 79951848565     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22643     Document Type: Article
Times cited : (16)

References (31)
  • 1
    • 0030099527 scopus 로고    scopus 로고
    • Transporting therapeutics across the blood-brain barrier
    • DOI 10.1016/1357-4310(96)88720-X
    • Abbott NJ, Romero IA,. Transporting therapeutics across the blood-brain barrier. Mol Med Today 1996; 2: 106-113. (Pubitemid 126407728)
    • (1996) Molecular Medicine Today , vol.2 , Issue.3 , pp. 106-113
    • Abbott, N.J.1    Romero, I.A.2
  • 2
    • 0031965788 scopus 로고    scopus 로고
    • Outwitting the blood-brain barrier for therapeutic purposes: Osmotic opening and other means
    • discussion 1099-1100.
    • Kroll RA, Neuwelt EA,. Outwitting the blood-brain barrier for therapeutic purposes: osmotic opening and other means. Neurosurgery 1998; 42: 1083-1099; discussion 1099-1100.
    • (1998) Neurosurgery , vol.42 , pp. 1083-1099
    • Kroll, R.A.1    Neuwelt, E.A.2
  • 3
    • 0642342131 scopus 로고    scopus 로고
    • Morphology and molecular properties of cellular components of normal cerebral vessels
    • Nag S,. Morphology and molecular properties of cellular components of normal cerebral vessels. Methods Mol Med 2003; 89: 3-36.
    • (2003) Methods Mol Med , vol.89 , pp. 3-36
    • Nag, S.1
  • 4
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K, McDannold N, Vykhodtseva N, Jolesz FA,. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 2001; 220: 640-646. (Pubitemid 32799969)
    • (2001) Radiology , vol.220 , Issue.3 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 5
    • 10044278240 scopus 로고    scopus 로고
    • Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications
    • DOI 10.1016/j.neuroimage.2004.06.046, PII S1053811904003362
    • Hynynen K, McDannold N, Sheikov NA, Jolesz FA, Vykhodtseva N,. Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications. Neuroimage 2005; 24: 12-20. (Pubitemid 39611021)
    • (2005) NeuroImage , vol.24 , Issue.1 , pp. 12-20
    • Hynynen, K.1    McDannold, N.2    Sheikov, N.A.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 6
    • 43849110904 scopus 로고    scopus 로고
    • Effects of Acoustic Parameters and Ultrasound Contrast Agent Dose on Focused-Ultrasound Induced Blood-Brain Barrier Disruption
    • DOI 10.1016/j.ultrasmedbio.2007.11.009, PII S0301562907005698
    • McDannold N, Vykhodtseva N, Hynynen K,. Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption. Ultrasound Med Biol 2008; 34: 930-937. (Pubitemid 351697595)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.6 , pp. 930-937
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 7
    • 67650266248 scopus 로고    scopus 로고
    • Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and definity in mice
    • Bing KF, Howles GP, Qi Y, Palmeri ML, Nightingale KR,. Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and definity in mice. Ultrasound Med Biol 2009; 35: 1298-1308.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 1298-1308
    • Bing, K.F.1    Howles, G.P.2    Qi, Y.3    Palmeri, M.L.4    Nightingale, K.R.5
  • 8
    • 48149101439 scopus 로고    scopus 로고
    • Progress and problems in the application of focused ultrasound for blood-brain barrier disruption
    • Vykhodtseva N, McDannold N, Hynynen K,. Progress and problems in the application of focused ultrasound for blood-brain barrier disruption. Ultrasonics 2008; 48: 279-296.
    • (2008) Ultrasonics , vol.48 , pp. 279-296
    • Vykhodtseva, N.1    McDannold, N.2    Hynynen, K.3
  • 9
    • 42949140276 scopus 로고    scopus 로고
    • Blood-Brain Barrier Disruption Induced by Focused Ultrasound and Circulating Preformed Microbubbles Appears to Be Characterized by the Mechanical Index
    • DOI 10.1016/j.ultrasmedbio.2007.10.016, PII S0301562907005480
    • McDannold N, Vykhodtseva N, Hynynen K,. Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index. Ultrasound Med Biol 2008; 34: 834-840. (Pubitemid 351608039)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.5 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 10
    • 60349085115 scopus 로고    scopus 로고
    • Magnetic resonance imaging enhanced by superparamagnetic iron oxide particles: Usefulness for distinguishing between focused ultrasound-induced blood-brain barrier disruption and brain hemorrhage
    • Liu HL, Hsu PH, Chu PC, Wai YY, Chen JC, Shen CR, Yen TC, Wang JJ,. Magnetic resonance imaging enhanced by superparamagnetic iron oxide particles: usefulness for distinguishing between focused ultrasound-induced blood-brain barrier disruption and brain hemorrhage. J Magn Reson Imaging 2009; 29: 31-38.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 31-38
    • Liu, H.L.1    Hsu, P.H.2    Chu, P.C.3    Wai, Y.Y.4    Chen, J.C.5    Shen, C.R.6    Yen, T.C.7    Wang, J.J.8
  • 13
    • 34247167626 scopus 로고    scopus 로고
    • Targeted drug delivery to the brain using focused ultrasound
    • DOI 10.1097/RMR.0b013e3180332e79, PII 0000214220060600000009
    • Kinoshita M,. Targeted drug delivery to the brain using focused ultrasound. Top Magn Reson Imaging 2006; 17: 209-215. (Pubitemid 46586213)
    • (2006) Topics in Magnetic Resonance Imaging , vol.17 , Issue.3 , pp. 209-215
    • Kinoshita, M.1
  • 15
    • 67649757597 scopus 로고    scopus 로고
    • Experimental study on targeted methotrexate delivery to the rabbit brain via magnetic resonance imaging-guided focused ultrasound
    • Mei J, Cheng Y, Song Y, Yang Y, Wang F, Liu Y, Wang Z,. Experimental study on targeted methotrexate delivery to the rabbit brain via magnetic resonance imaging-guided focused ultrasound. J Ultrasound Med 2009; 28: 871-880.
    • (2009) J Ultrasound Med , vol.28 , pp. 871-880
    • Mei, J.1    Cheng, Y.2    Song, Y.3    Yang, Y.4    Wang, F.5    Liu, Y.6    Wang, Z.7
  • 17
    • 48249140247 scopus 로고    scopus 로고
    • Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models
    • Raymond SB, Treat LH, Dewey JD, McDannold NJ, Hynynen K, Bacskai BJ,. Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models. PLoS ONE 2008; 3: e2175.
    • (2008) PLoS ONE , vol.3
    • Raymond, S.B.1    Treat, L.H.2    Dewey, J.D.3    McDannold, N.J.4    Hynynen, K.5    Bacskai, B.J.6
  • 18
    • 40949159717 scopus 로고    scopus 로고
    • Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging
    • Liu HL, Wai YY, Chen WS, Chen JC, Hsu PH, Wu XY, Huang WC, Yen TC, Wang JJ,. Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging. Ultrasound Med Biol 2008; 34: 598-606.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 598-606
    • Liu, H.L.1    Wai, Y.Y.2    Chen, W.S.3    Chen, J.C.4    Hsu, P.H.5    Wu, X.Y.6    Huang, W.C.7    Yen, T.C.8    Wang, J.J.9
  • 20
    • 35848934576 scopus 로고    scopus 로고
    • Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound
    • DOI 10.1088/0031-9155/52/18/004, PII S0031915507441641
    • Choi JJ, Pernot M, Brown TR, Small SA, Konofagou EE,. Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound. Phys Med Biol 2007; 52: 5509-5530. (Pubitemid 350056681)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.18 , pp. 5509-5530
    • Choi, J.J.1    Pernot, M.2    Brown, T.R.3    Small, S.A.4    Konofagou, E.E.5
  • 21
    • 33748483260 scopus 로고    scopus 로고
    • Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery
    • Hynynen K, McDannold N, Vykhodtseva N, Raymond S, Weissleder R, Jolesz FA, Sheikov N,. Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery. J Neurosurg 2006; 105: 445-454. (Pubitemid 44358757)
    • (2006) Journal of Neurosurgery , vol.105 , Issue.3 , pp. 445-454
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Raymond, S.4    Weissleder, R.5    Jolesz, F.A.6    Sheikov, N.7
  • 22
    • 65449147886 scopus 로고    scopus 로고
    • An MRI-compatible system for focused ultrasound experiments in small animal models
    • Chopra R, Curiel L, Staruch R, Morrison L, Hynynen K,. An MRI-compatible system for focused ultrasound experiments in small animal models. Med Phys 2009; 36: 1867-1874.
    • (2009) Med Phys , vol.36 , pp. 1867-1874
    • Chopra, R.1    Curiel, L.2    Staruch, R.3    Morrison, L.4    Hynynen, K.5
  • 23
    • 65549125603 scopus 로고    scopus 로고
    • Transcranial shear-mode ultrasound: Assessment of imaging performance and excitation techniques
    • Yousefi A, Goertz DE, Hynynen K,. Transcranial shear-mode ultrasound: assessment of imaging performance and excitation techniques. IEEE Trans Med Imaging 2009; 28: 763-774.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 763-774
    • Yousefi, A.1    Goertz, D.E.2    Hynynen, K.3
  • 24
    • 33644802027 scopus 로고    scopus 로고
    • 1 mapping
    • DOI 10.1002/mrm.20797
    • Chuang KH, Koretsky A,. Improved neuronal tract tracing using manganese enhanced magnetic resonance imaging with fast T(1) mapping. Magn Reson Med 2006; 55: 604-611. (Pubitemid 43352560)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.3 , pp. 604-611
    • Chuang, K.-H.1    Koretsky, A.2
  • 25
    • 67049169039 scopus 로고    scopus 로고
    • 2) in the rat brain are consistent with the tissue-clearance rates of elemental manganese
    • 2) in the rat brain are consistent with the tissue-clearance rates of elemental manganese. Magn Reson Med 2009; 61: 1528-1532.
    • (2009) Magn Reson Med , vol.61 , pp. 1528-1532
    • Chuang, K.H.1    Koretsky, A.P.2    Sotak, C.H.3
  • 26
    • 34548130700 scopus 로고    scopus 로고
    • Quantitative evaluation of focused ultrasound with a contrast agent on blood-brain barrier disruption
    • Yang FY, Fu WM, Yang RS, Liou HC, Kang KH, Lin WL,. Quantitative evaluation of focused ultrasound with a contrast agent on blood-brain barrier disruption. Ultrasound Med Biol 2007; 33: 1421-1427.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1421-1427
    • Yang, F.Y.1    Fu, W.M.2    Yang, R.S.3    Liou, H.C.4    Kang, K.H.5    Lin, W.L.6
  • 27
    • 44249098561 scopus 로고    scopus 로고
    • Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    • Yang FY, Fu WM, Chen WS, Yeh WL, Lin WL,. Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption. Ultrason Sonochem 2008; 15: 636-643.
    • (2008) Ultrason Sonochem , vol.15 , pp. 636-643
    • Yang, F.Y.1    Fu, W.M.2    Chen, W.S.3    Yeh, W.L.4    Lin, W.L.5
  • 28
    • 77952857980 scopus 로고    scopus 로고
    • Pulse sequence and timing of contrast-enhanced MRI for assessing blood-brain barrier disruption after transcranial focused ultrasound in the presence of hemorrhage
    • Weng JC, Wu SK, Yang FY, Lin WL, Tseng WY,. Pulse sequence and timing of contrast-enhanced MRI for assessing blood-brain barrier disruption after transcranial focused ultrasound in the presence of hemorrhage. J Magn Reson Imaging 2010; 31: 1323-1330.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 1323-1330
    • Weng, J.C.1    Wu, S.K.2    Yang, F.Y.3    Lin, W.L.4    Tseng, W.Y.5
  • 29
    • 4143081639 scopus 로고    scopus 로고
    • Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles
    • DOI 10.1016/j.ultrasmedbio.2004.04.010, PII S0301562904001115
    • Sheikov N, McDannold N, Vykhodtseva N, Jolesz F, Hynynen K,. Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles. Ultrasound Med Biol 2004; 30: 979-989. (Pubitemid 39094314)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.7 , pp. 979-989
    • Sheikov, N.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.4    Hynynen, K.5
  • 30
    • 73949102878 scopus 로고    scopus 로고
    • In vivo assessment of macrophage CNS infiltration during disruption of the blood-brain barrier with focused ultrasound: A magnetic resonance imaging study
    • Liu HL, Wai YY, Hsu PH, Lyu LA, Wu JS, Shen CR, Chen JC, Yen TC, Wang JJ,. In vivo assessment of macrophage CNS infiltration during disruption of the blood-brain barrier with focused ultrasound: a magnetic resonance imaging study. J Cereb Blood Flow Metab 2009; 30: 177-186.
    • (2009) J Cereb Blood Flow Metab , vol.30 , pp. 177-186
    • Liu, H.L.1    Wai, Y.Y.2    Hsu, P.H.3    Lyu, L.A.4    Wu, J.S.5    Shen, C.R.6    Chen, J.C.7    Yen, T.C.8    Wang, J.J.9
  • 31
    • 45949097554 scopus 로고    scopus 로고
    • Effect of Focused Ultrasound Applied With an Ultrasound Contrast Agent on the Tight Junctional Integrity of the Brain Microvascular Endothelium
    • DOI 10.1016/j.ultrasmedbio.2007.12.015, PII S030156290700659X
    • Sheikov N, McDannold N, Sharma S, Hynynen K,. Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium. Ultrasound Med Biol 2008; 34: 1093-1104. (Pubitemid 351893156)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.7 , pp. 1093-1104
    • Sheikov, N.1    McDannold, N.2    Sharma, S.3    Hynynen, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.