메뉴 건너뛰기




Volumn 33, Issue 2, 2011, Pages 372-381

Performance of μmRI-Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength

Author keywords

7.0T; digital topological analysis; fast spin echo; finite element analysis; trabecular bone; ultra high field MRI

Indexed keywords

ADULT; ARTICLE; BONE BIOPSY; CORRELATION COEFFICIENT; DIAGNOSTIC TEST ACCURACY STUDY; FAST SPIN ECHO; FINITE ELEMENT ANALYSIS; FOLLOW UP; HUMAN; MALE; MICRO MAGNETIC RESONANCE IMAGING; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIATION FIELD; RELIABILITY; REPRODUCIBILITY; RETROSPECTIVE STUDY; SENSITIVITY ANALYSIS; SHEAR STRENGTH; SIGNAL NOISE RATIO; THREE DIMENSIONAL IMAGING; TIBIA; TRABECULAR BONE; VIRTUAL REALITY; YOUNG MODULUS;

EID: 79551561501     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22439     Document Type: Article
Times cited : (19)

References (46)
  • 1
    • 33744743258 scopus 로고    scopus 로고
    • Advanced imaging assessment of bone quality
    • Genant HK, Jiang Y,. Advanced imaging assessment of bone quality. Ann N Y Acad Sci 2006; 1068: 410-428.
    • (2006) Ann N y Acad Sci , vol.1068 , pp. 410-428
    • Genant, H.K.1    Jiang, Y.2
  • 2
    • 77950669298 scopus 로고    scopus 로고
    • How does human bone resist fracture?
    • Ritchie RO,. How does human bone resist fracture? Ann N Y Acad Sci 2010; 1192: 72-80.
    • (2010) Ann N y Acad Sci , vol.1192 , pp. 72-80
    • Ritchie, R.O.1
  • 3
    • 69849085948 scopus 로고    scopus 로고
    • Advances in osteoporosis imaging
    • Bauer JS, Link TM,. Advances in osteoporosis imaging. Eur J Radiology 2009; 71: 440-449.
    • (2009) Eur J Radiology , vol.71 , pp. 440-449
    • Bauer, J.S.1    Link, T.M.2
  • 4
    • 77950643657 scopus 로고    scopus 로고
    • Looking beyond bone mineral density: Imaging assessment of bone quality
    • Griffith JF, Engelke K, Genant HK,. Looking beyond bone mineral density: Imaging assessment of bone quality. Ann N Y Acad Sci 2010; 1192: 45-56.
    • (2010) Ann N y Acad Sci , vol.1192 , pp. 45-56
    • Griffith, J.F.1    Engelke, K.2    Genant, H.K.3
  • 5
    • 0036815594 scopus 로고    scopus 로고
    • Magnetic resonance imaging of trabecular bone structure
    • Majumdar S,. Magnetic resonance imaging of trabecular bone structure. Top Magn Reson Imaging 2002; 13: 323-334.
    • (2002) Top Magn Reson Imaging , vol.13 , pp. 323-334
    • Majumdar, S.1
  • 6
    • 33846850575 scopus 로고    scopus 로고
    • Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging
    • Wehrli FW,. Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging. J Magn Reson Imaging 2007: 390-409.
    • (2007) J Magn Reson Imaging , pp. 390-409
    • Wehrli, F.W.1
  • 7
    • 33751383444 scopus 로고    scopus 로고
    • Quantitative MRI for the assessment of bone structure and function
    • Wehrli FW, Song HK, Saha PK, Wright AC,. Quantitative MRI for the assessment of bone structure and function. NMR Biomed 2006; 19: 731-764.
    • (2006) NMR Biomed , vol.19 , pp. 731-764
    • Wehrli, F.W.1    Song, H.K.2    Saha, P.K.3    Wright, A.C.4
  • 8
    • 50249184720 scopus 로고    scopus 로고
    • In vivo microMRI-based finite element and morphological analyses of tibial trabecular bone in eugonadal and hypogonadal men before and after testosterone treatment
    • Zhang XH, Liu XS, Vasilic B, et al. In vivo microMRI-based finite element and morphological analyses of tibial trabecular bone in eugonadal and hypogonadal men before and after testosterone treatment. J Bone Miner Res 2008; 23: 1426-1434.
    • (2008) J Bone Miner Res , vol.23 , pp. 1426-1434
    • Zhang, X.H.1    Liu, X.S.2    Vasilic, B.3
  • 9
    • 77953511836 scopus 로고    scopus 로고
    • Mechanical implications of estrogen supplementation in early postmenopausal women
    • Wehrli FW, Rajapakse CS, Magland JF, Snyder PJ,. Mechanical implications of estrogen supplementation in early postmenopausal women. J Bone Miner Res 2010; 25: 1406-1414.
    • (2010) J Bone Miner Res , vol.25 , pp. 1406-1414
    • Wehrli, F.W.1    Rajapakse, C.S.2    Magland, J.F.3    Snyder, P.J.4
  • 10
    • 0031915851 scopus 로고    scopus 로고
    • Cancellous bone volume and structure in the forearm: Noninvasive assessment with MR microimaging and image processing
    • [erratum, Radiology, 1998;207:833].
    • Wehrli FW, Hwang SN, Ma J, Song HK, Ford JC, Haddad JG,. Cancellous bone volume and structure in the forearm: noninvasive assessment with MR microimaging and image processing. Radiology 1998; 206: 347-357 [erratum, Radiology, 1998;207:833].
    • (1998) Radiology , vol.206 , pp. 347-357
    • Wehrli, F.W.1    Hwang, S.N.2    Ma, J.3    Song, H.K.4    Ford, J.C.5    Haddad, J.G.6
  • 11
    • 0037950421 scopus 로고    scopus 로고
    • Trabecular bone structure of the calcaneus: Preliminary in vivo MR imaging assessment in men with osteoporosis
    • Boutry N, Cortet B, Dubois P, Marchandise X, Cotten A,. Trabecular bone structure of the calcaneus: preliminary in vivo MR imaging assessment in men with osteoporosis. Radiology 2003; 227: 708-717.
    • (2003) Radiology , vol.227 , pp. 708-717
    • Boutry, N.1    Cortet, B.2    Dubois, P.3    Marchandise, X.4    Cotten, A.5
  • 12
    • 20044386323 scopus 로고    scopus 로고
    • Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: Simulations and experiments
    • Banerjee S, Han ET, Krug R, Newitt DC, Majumdar S,. Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: simulations and experiments. J Magn Reson Imaging 2005; 21: 818-825.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 818-825
    • Banerjee, S.1    Han, E.T.2    Krug, R.3    Newitt, D.C.4    Majumdar, S.5
  • 13
    • 33846785601 scopus 로고    scopus 로고
    • Ultra-high-field MRI of the musculoskeletal system at 7.0T
    • Regatte RR, Schweitzer ME,. Ultra-high-field MRI of the musculoskeletal system at 7.0T. J Magn Reson Imaging 2007; 25: 262-269.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 262-269
    • Regatte, R.R.1    Schweitzer, M.E.2
  • 14
    • 70350728534 scopus 로고    scopus 로고
    • Imaging of the musculoskeletal system in vivo using ultra-high field magnetic resonance at 7 T
    • Krug R, Stehling C, Kelley DA, Majumdar S, Link TM,. Imaging of the musculoskeletal system in vivo using ultra-high field magnetic resonance at 7 T. Invest Radiol 2009; 44: 613-618.
    • (2009) Invest Radiol , vol.44 , pp. 613-618
    • Krug, R.1    Stehling, C.2    Kelley, D.A.3    Majumdar, S.4    Link, T.M.5
  • 15
    • 36849065200 scopus 로고    scopus 로고
    • In vivo bone and cartilage MRI using fully-balanced steady-state free-precession at 7 Tesla
    • Krug R, Carballido-Gamio J, Banerjee S, et al. In vivo bone and cartilage MRI using fully-balanced steady-state free-precession at 7 Tesla. Magn Reson Med 2007; 58: 1294-1298.
    • (2007) Magn Reson Med , vol.58 , pp. 1294-1298
    • Krug, R.1    Carballido-Gamio, J.2    Banerjee, S.3
  • 16
    • 77951583518 scopus 로고    scopus 로고
    • Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 Tesla field strength
    • Wald MJ, Magland JF, Rajapakse CS, Wehrli FW,. Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 Tesla field strength. J Magn Reson Imaging 2010; 31: 1157-1168.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 1157-1168
    • Wald, M.J.1    Magland, J.F.2    Rajapakse, C.S.3    Wehrli, F.W.4
  • 17
    • 40449108195 scopus 로고    scopus 로고
    • Rapid in vivo musculoskeletal MR with parallel imaging at 7T
    • Banerjee S, Krug R, Carballido-Gamio J, et al. Rapid in vivo musculoskeletal MR with parallel imaging at 7T. Magn Reson Med 2008; 59: 655-660.
    • (2008) Magn Reson Med , vol.59 , pp. 655-660
    • Banerjee, S.1    Krug, R.2    Carballido-Gamio, J.3
  • 18
    • 77649116906 scopus 로고    scopus 로고
    • 3D fast spin echo with out-of-slab cancellation: A technique for high-resolution structural imaging of trabecular bone at 7 Tesla
    • Magland JF, Rajapakse CS, Wright AC, Acciavatti R, Wehrli FW,. 3D fast spin echo with out-of-slab cancellation: a technique for high-resolution structural imaging of trabecular bone at 7 Tesla. Magn Reson Med 2010; 63: 719-727.
    • (2010) Magn Reson Med , vol.63 , pp. 719-727
    • Magland, J.F.1    Rajapakse, C.S.2    Wright, A.C.3    Acciavatti, R.4    Wehrli, F.W.5
  • 20
    • 0023808962 scopus 로고
    • Clinical applications and methodological developments of the RARE technique
    • Hennig J, Friedburg H,. Clinical applications and methodological developments of the RARE technique. Magn Reson Imaging 1988; 6: 391-395.
    • (1988) Magn Reson Imaging , vol.6 , pp. 391-395
    • Hennig, J.1    Friedburg, H.2
  • 21
    • 77955302166 scopus 로고    scopus 로고
    • Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T2-weighted and fluid-attenuated whole-brain imaging
    • Park J, Park S, Yeop Kim E, Suh JS,. Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T2-weighted and fluid-attenuated whole-brain imaging. Magn Reson Med 2010; 63: 1422-1430.
    • (2010) Magn Reson Med , vol.63 , pp. 1422-1430
    • Park, J.1    Park, S.2    Yeop Kim, E.3    Suh, J.S.4
  • 22
    • 58149196705 scopus 로고    scopus 로고
    • Ankle: Isotropic MR imaging with 3D-FSE-cube-initial experience in healthy volunteers
    • Stevens KJ, Busse RF, Han E, et al. Ankle: isotropic MR imaging with 3D-FSE-cube-initial experience in healthy volunteers. Radiology 2008; 249: 1026-1033.
    • (2008) Radiology , vol.249 , pp. 1026-1033
    • Stevens, K.J.1    Busse, R.F.2    Han, E.3
  • 23
    • 27644439963 scopus 로고    scopus 로고
    • Implications of pulse sequence in structural imaging of trabecular bone
    • Techawiboonwong A, Song H, Saha P, Wehrli F,. Implications of pulse sequence in structural imaging of trabecular bone. J Magn Reson Imaging 2005; 22: 647-655.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 647-655
    • Techawiboonwong, A.1    Song, H.2    Saha, P.3    Wehrli, F.4
  • 25
    • 79551528985 scopus 로고    scopus 로고
    • 7T transmit four-channel receive array for high-resolution MRI of trabecular bone in distal tibia
    • Honolulu; (abstract 256)
    • Wright AC, Wald M, Connick T, et al. 7T transmit four-channel receive array for high-resolution MRI of trabecular bone in distal tibia. In: Proc 17th Annual Meeting ISMRM, Honolulu; 2009 (abstract 256).
    • (2009) Proc 17th Annual Meeting ISMRM
    • Wright, A.C.1    Wald, M.2    Connick, T.3
  • 26
    • 24144469169 scopus 로고    scopus 로고
    • Improved data reconstruction method for GRAPPA
    • Wang Z, Wang J, Detre JA,. Improved data reconstruction method for GRAPPA. Magn Reson Med 2005; 54: 738-742.
    • (2005) Magn Reson Med , vol.54 , pp. 738-742
    • Wang, Z.1    Wang, J.2    Detre, J.A.3
  • 27
    • 0032904175 scopus 로고    scopus 로고
    • Automatic compensation of motion artifacts in MRI
    • Atkinson D, Hill DL, Stoyle PN, et al. Automatic compensation of motion artifacts in MRI. Magn Reson Med 1999; 41: 163-170.
    • (1999) Magn Reson Med , vol.41 , pp. 163-170
    • Atkinson, D.1    Hill, D.L.2    Stoyle, P.N.3
  • 28
    • 34547816554 scopus 로고    scopus 로고
    • Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging
    • Lin W, Ladinsky GA, Wehrli F, Song HK,. Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging. J Magn Reson Imaging 2007; 26: 191-197.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 191-197
    • Lin, W.1    Ladinsky, G.A.2    Wehrli, F.3    Song, H.K.4
  • 29
    • 60349107639 scopus 로고    scopus 로고
    • Retrospective 3D registration of trabecular bone MR images for longitudinal studies
    • Magland JF, Jones CE, Leonard MB, Wehrli FW,. Retrospective 3D registration of trabecular bone MR images for longitudinal studies. J Magn Reson Imaging 2009; 29: 118-126.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 118-126
    • Magland, J.F.1    Jones, C.E.2    Leonard, M.B.3    Wehrli, F.W.4
  • 30
    • 29144441427 scopus 로고    scopus 로고
    • A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in-vivo MRI
    • Vasilic B, Wehrli FW,. A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in-vivo MRI. IEEE Trans Med Imaging 2005; 24: 1574-1585.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 1574-1585
    • Vasilic, B.1    Wehrli, F.W.2
  • 31
    • 77955846609 scopus 로고    scopus 로고
    • Computational biomechanics of the distal tibia from high-resolution MR and micro-CT images
    • Rajapakse CS, Magland JF, Wald MJ, et al. Computational biomechanics of the distal tibia from high-resolution MR and micro-CT images. Bone 2010; 47: 556-563.
    • (2010) Bone , vol.47 , pp. 556-563
    • Rajapakse, C.S.1    Magland, J.F.2    Wald, M.J.3
  • 33
    • 0346076620 scopus 로고    scopus 로고
    • Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform
    • Saha P, Wehrli F,. Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform. IEEE Trans Med Imaging 2004; 23: 53-62.
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 53-62
    • Saha, P.1    Wehrli, F.2
  • 34
    • 55349100219 scopus 로고    scopus 로고
    • Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI
    • Magland JF, Wehrli FW,. Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI. Acad Radiol 2008; 15: 1482-1493.
    • (2008) Acad Radiol , vol.15 , pp. 1482-1493
    • Magland, J.F.1    Wehrli, F.W.2
  • 35
    • 0030561004 scopus 로고    scopus 로고
    • Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture
    • Van Rietbergen B, Odgaard A, Kabel J, Huiskes R,. Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. J Biomech 1996; 29: 1653-1657.
    • (1996) J Biomech , vol.29 , pp. 1653-1657
    • Van Rietbergen, B.1    Odgaard, A.2    Kabel, J.3    Huiskes, R.4
  • 36
    • 2942754052 scopus 로고    scopus 로고
    • Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia
    • Gomberg BR, Wehrli FW, Vasilic B, et al. Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia. Bone 2004; 35: 266-276.
    • (2004) Bone , vol.35 , pp. 266-276
    • Gomberg, B.R.1    Wehrli, F.W.2    Vasilic, B.3
  • 37
    • 0034922577 scopus 로고    scopus 로고
    • Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosis
    • Wehrli FW, Gomberg BR, Saha PK, Song HK, Hwang SN, Snyder PJ,. Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosis. J Bone Miner Res 2001; 16: 1520-1531.
    • (2001) J Bone Miner Res , vol.16 , pp. 1520-1531
    • Wehrli, F.W.1    Gomberg, B.R.2    Saha, P.K.3    Song, H.K.4    Hwang, S.N.5    Snyder, P.J.6
  • 38
    • 37549053251 scopus 로고    scopus 로고
    • Trabecular structure quantified with the MRI-based virtual bone biopsy in postmenopausal women contributes to vertebral deformity burden independent of areal vertebral BMD
    • Ladinsky GA, Vasilic B, Popescu AM, et al. Trabecular structure quantified with the MRI-based virtual bone biopsy in postmenopausal women contributes to vertebral deformity burden independent of areal vertebral BMD. J Bone Miner Res 2008; 23: 64-74.
    • (2008) J Bone Miner Res , vol.23 , pp. 64-74
    • Ladinsky, G.A.1    Vasilic, B.2    Popescu, A.M.3
  • 39
    • 0033047422 scopus 로고    scopus 로고
    • Direct three-dimensional morphometric analysis of human cancellous bone: Microstructural data from spine, femur, iliac crest, and calcaneus
    • Hildebrand T, Laib A, Muller R, Dequeker J, Ruegsegger P,. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res 1999; 14: 1167-1174.
    • (1999) J Bone Miner Res , vol.14 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Muller, R.3    Dequeker, J.4    Ruegsegger, P.5
  • 40
    • 56749158485 scopus 로고    scopus 로고
    • Implications of resolution and noise for in vivo micro-MRI of trabecular bone
    • Li CQ, Magland JF, Rajapakse CS, et al. Implications of resolution and noise for in vivo micro-MRI of trabecular bone. Med Phys 2008; 35: 5584-5594.
    • (2008) Med Phys , vol.35 , pp. 5584-5594
    • Li, C.Q.1    Magland, J.F.2    Rajapakse, C.S.3
  • 41
    • 0036245213 scopus 로고    scopus 로고
    • Processing and analysis of in vivo high-resolution MR images of trabecular bone for longitudinal studies: Reproducibility of structural measures and micro-finite element analysis derived mechanical properties
    • Newitt DC, van Rietbergen B, Majumdar S,. Processing and analysis of in vivo high-resolution MR images of trabecular bone for longitudinal studies: reproducibility of structural measures and micro-finite element analysis derived mechanical properties. Osteoporos Int 2002; 13: 278-287.
    • (2002) Osteoporos Int , vol.13 , pp. 278-287
    • Newitt, D.C.1    Van Rietbergen, B.2    Majumdar, S.3
  • 42
    • 66149109238 scopus 로고    scopus 로고
    • Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE)
    • Magland JF, Wald MJ, Wehrli FW,. Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE). Magn Reson Med 2009; 61: 1114-1121.
    • (2009) Magn Reson Med , vol.61 , pp. 1114-1121
    • Magland, J.F.1    Wald, M.J.2    Wehrli, F.W.3
  • 43
    • 3242803606 scopus 로고    scopus 로고
    • Musculoskeletal MRI at 3.0 T: Relaxation times and image contrast
    • Gold GE, Han E, Stainsby J, Wright G, Brittain J, Beaulieu C,. Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. AJR 2004; 183: 343-351.
    • (2004) AJR , vol.183 , pp. 343-351
    • Gold, G.E.1    Han, E.2    Stainsby, J.3    Wright, G.4    Brittain, J.5    Beaulieu, C.6
  • 44
    • 53149105563 scopus 로고    scopus 로고
    • Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 Tesla
    • Ren J, Dimitrov I, Sherry AD, Malloy CR,. Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 Tesla. J Lipid Res 2008; 49: 2055-2062.
    • (2008) J Lipid Res , vol.49 , pp. 2055-2062
    • Ren, J.1    Dimitrov, I.2    Sherry, A.D.3    Malloy, C.R.4
  • 45
    • 0019523285 scopus 로고
    • Active bone marrow distribution as a function of age in humans
    • Cristy M,. Active bone marrow distribution as a function of age in humans. Phys Med Biol 1981; 26: 389-400.
    • (1981) Phys Med Biol , vol.26 , pp. 389-400
    • Cristy, M.1
  • 46
    • 25444504798 scopus 로고    scopus 로고
    • Effect of testosterone replacement on bone architecture in hypogonadal men
    • Benito M, Vasilic B, Wehrli FW, et al. Effect of testosterone replacement on bone architecture in hypogonadal men. J Bone Miner Res 2005; 20: 1785-1791.
    • (2005) J Bone Miner Res , vol.20 , pp. 1785-1791
    • Benito, M.1    Vasilic, B.2    Wehrli, F.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.