메뉴 건너뛰기




Volumn 31, Issue 5, 2010, Pages 1157-1168

Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 Tesla field strength

Author keywords

Micro MRI; Osteoporosis; Quantitative imaging; Resolution isotropy; Trabecular bone

Indexed keywords

ADULT; ANISOTROPY; ARTICLE; ARTIFACT REDUCTION; BIOMECHANICS; BONE RADIOGRAPHY; BONE STRUCTURE; COMPRESSIVE STRENGTH; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE RECONSTRUCTION; IN VIVO STUDY; MALE; METAPHYSIS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; SHEAR STRESS; THREE TESLA HIGH RESOLUTION IMAGING; TIBIA; TRABECULAR BONE; YOUNG MODULUS;

EID: 77951583518     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22158     Document Type: Article
Times cited : (31)

References (44)
  • 1
    • 33847703730 scopus 로고    scopus 로고
    • Quantifying anisotropy of trabecular bone from gray-level images
    • DOI 10.1016/j.bone.2006.10.022, PII S8756328206008003
    • Tabor Z, Rokita E. Quantifying anisotropy of trabecular bone from gray-level images. Bone 2007;40:966-972. (Pubitemid 46386533)
    • (2007) Bone , vol.40 , Issue.4 , pp. 966-972
    • Tabor, Z.1    Rokita, E.2
  • 2
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • DOI 10.1016/S8756-3282(99)00098-8, PII S8756328299000988
    • Ulrich D, van Rietbergen B, Laib A, Ruegsegger P. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 1999;25:55-60. (Pubitemid 29322061)
    • (1999) Bone , vol.25 , Issue.1 , pp. 55-60
    • Ulrich, D.1    Van Rietbergen, B.2    Laib, A.3    Ruegsegger, P.4
  • 4
    • 0036755796 scopus 로고    scopus 로고
    • Contribution of trabecular and cortical components to the mechanical properties of bone and their regulating parameters
    • DOI 10.1016/S8756-3282(02)00830-X, PII S875632820200830X
    • Ito M, Nishida A, Koga A, et al. Contribution of trabecular and cortical components to the mechanical properties of bone and their regulating parameters. Bone 2002;31:351-358. (Pubitemid 35299613)
    • (2002) Bone , vol.31 , Issue.3 , pp. 351-358
    • Ito, M.1    Nishida, A.2    Koga, A.3    Ikeda, S.4    Shiraishi, A.5    Uetani, M.6    Hayashi, K.7    Nakamura, T.8
  • 5
    • 0034956814 scopus 로고    scopus 로고
    • Trabecular bone volume fraction mapping by low-resolution MRI
    • Fernandez-Seara MA, Song HK, Wehrli FW. Trabecular bone volume fraction mapping by low-resolution MRI. Magn Reson Med 2001;46:103-113.
    • (2001) Magn Reson Med , vol.46 , pp. 103-113
    • Fernandez-Seara, M.A.1    Song, H.K.2    Wehrli, F.W.3
  • 6
    • 0036815594 scopus 로고    scopus 로고
    • Magnetic resonance imaging of trabecular bone structure
    • DOI 10.1097/00002142-200210000-00004
    • Majumdar S. Magnetic resonance imaging of trabecular bone structure. Top Magn Reson Imaging 2002;13:323-334. (Pubitemid 35425335)
    • (2002) Topics in Magnetic Resonance Imaging , vol.13 , Issue.5 , pp. 323-334
    • Majumdar, S.1
  • 7
    • 34250013862 scopus 로고    scopus 로고
    • Load distribution and the predictive power of morphological indices in the distal radius and tibia by high resolution peripheral quantitative computed tomography
    • MacNeil JA, Boyd SK. Load distribution and the predictive power of morphological indices in the distal radius and tibia by high resolution peripheral quantitative computed tomography. Bone 2007;41:129-137.
    • (2007) Bone , vol.41 , pp. 129-137
    • MacNeil, J.A.1    Boyd, S.K.2
  • 9
    • 0036173612 scopus 로고    scopus 로고
    • In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radius
    • Newitt DC, Majumdar S, van Rietbergen B, et al. In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radius. Osteoporos Int 2002;13:6-17.
    • (2002) Osteoporos Int , vol.13 , pp. 6-17
    • Newitt, D.C.1    Majumdar, S.2    Van Rietbergen, B.3
  • 10
    • 70349200747 scopus 로고    scopus 로고
    • Implications of noise and resolution on mechanical properties of trabecular bone estimated by image-based finite-element analysis
    • Rajapakse CS, Magland J, Zhang XH, et al. Implications of noise and resolution on mechanical properties of trabecular bone estimated by image-based finite-element analysis. J Orthop Res 2009;27:1263-1271.
    • (2009) J Orthop Res , vol.27 , pp. 1263-1271
    • Rajapakse, C.S.1    Magland, J.2    Zhang, X.H.3
  • 11
    • 50249184720 scopus 로고    scopus 로고
    • In vivo microMRI-based finite element and morphological analyses of tibial trabecular bone in eugonadal and hypogonadal men before and after testosterone treatment
    • Zhang XH, Liu XS, Vasilic B, et al. In vivo microMRI-based finite element and morphological analyses of tibial trabecular bone in eugonadal and hypogonadal men before and after testosterone treatment. J Bone Miner Res 2008;23:1426-1434.
    • (2008) J Bone Miner Res , vol.23 , pp. 1426-1434
    • Zhang, X.H.1    Liu, X.S.2    Vasilic, B.3
  • 13
    • 3543121914 scopus 로고    scopus 로고
    • Coherence-induced artifacts in large-flip-angle steady-state spin-echo imaging
    • DOI 10.1002/mrm.20156
    • Vasilic B, Song HK, Wehrli FW. Coherence-induced artifacts in large-flip-angle steady-state spin-echo imaging. Magn Reson Med 2004;52:346-353. (Pubitemid 39025279)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.2 , pp. 346-353
    • Vasilic, B.1    Song, H.K.2    Wehrli, F.W.3
  • 14
    • 66149109238 scopus 로고    scopus 로고
    • Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE)
    • Magland JF, Wald MJ, Wehrli FW. Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE). Magn Reson Med 2009;61:1114-1121.
    • (2009) Magn Reson Med , vol.61 , pp. 1114-1121
    • Magland, J.F.1    Wald, M.J.2    Wehrli, F.W.3
  • 15
    • 0036814745 scopus 로고    scopus 로고
    • Role of magnetic resonance for assessing structure and function of trabecular bone
    • Wehrli FW, Saha PK, Gomberg BR, et al. Role of magnetic resonance for assessing structure and function of trabecular bone. Top Magn Reson Imaging 2002;13:335-355.
    • (2002) Top Magn Reson Imaging , vol.13 , pp. 335-355
    • Wehrli, F.W.1    Saha, P.K.2    Gomberg, B.R.3
  • 17
    • 42549086756 scopus 로고    scopus 로고
    • Fast prospective registration of in vivo MR images of trabecular bone microstructure in longitudinal studies
    • Rajapakse CS, Magland JF, Wehrli FW. Fast prospective registration of in vivo MR images of trabecular bone microstructure in longitudinal studies. Magn Reson Med 2008;59:1120-1126.
    • (2008) Magn Reson Med , vol.59 , pp. 1120-1126
    • Rajapakse, C.S.1    Magland, J.F.2    Wehrli, F.W.3
  • 18
    • 0029894505 scopus 로고    scopus 로고
    • Fast 3D large-angle spin-echo imaging (3D FLASE)
    • DOI 10.1002/mrm.1910350619
    • Ma J, Wehrli FW, Song HK. Fast 3D large-angle spin-echo imaging (3D FLASE). Magn Reson Med 1996;35:903-910. (Pubitemid 26172628)
    • (1996) Magnetic Resonance in Medicine , vol.35 , Issue.6 , pp. 903-910
    • Ma, J.1    Wehrli, F.W.2    Song, H.K.3
  • 19
    • 0344689909 scopus 로고    scopus 로고
    • In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis
    • Song HK, Wehrli FW. In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis. Magn Reson Med 1999;41:947-953.
    • (1999) Magn Reson Med , vol.41 , pp. 947-953
    • Song, H.K.1    Wehrli, F.W.2
  • 20
    • 34547816554 scopus 로고    scopus 로고
    • Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging
    • DOI 10.1002/jmri.20958
    • Lin W, Ladinsky GA, Wehrli FW, Song HK. Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging. J Magn Reson Imaging 2007;26:191-197. (Pubitemid 47235250)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.1 , pp. 191-197
    • Lin, W.1    Ladinsky, G.A.2    Wehrli, F.W.3    Hee, K.S.4
  • 22
    • 24144469169 scopus 로고    scopus 로고
    • Improved data reconstruction method for GRAPPA
    • DOI 10.1002/mrm.20601
    • Wang Z, Wang J, Detre JA. Improved data reconstruction method for GRAPPA. Magn Reson Med 2005;54:738-742. (Pubitemid 41233772)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.3 , pp. 738-742
    • Wang, Z.1    Wang, J.2    Detre, J.A.3
  • 24
    • 60349107639 scopus 로고    scopus 로고
    • Retrospective 3D registration of trabecular bone MR images for longitudinal studies
    • Magland JF, Jones CE, Leonard MB, Wehrli FW. Retrospective 3D registration of trabecular bone MR images for longitudinal studies. J Magn Reson Imaging 2009;29:118-126.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 118-126
    • Magland, J.F.1    Jones, C.E.2    Leonard, M.B.3    Wehrli, F.W.4
  • 25
    • 55349100219 scopus 로고    scopus 로고
    • Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI
    • Magland JF, Wehrli FW. Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI. Acad Radiol 2008;15:1482-1493.
    • (2008) Acad Radiol , vol.15 , pp. 1482-1493
    • Magland, J.F.1    Wehrli, F.W.2
  • 26
    • 29144441427 scopus 로고    scopus 로고
    • A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in vivo MRI
    • DOI 10.1109/TMI.2005.859192
    • Vasilic B, Wehrli FW. A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in vivo MRI. IEEE Trans Med Imaging 2005;24: 1574-1585. (Pubitemid 41812025)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.12 , pp. 1574-1585
    • Vasilic, B.1    Wehrli, F.W.2
  • 27
    • 0346076620 scopus 로고    scopus 로고
    • Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform
    • Saha PK, Wehrli FW. Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform. IEEE Trans Med Imaging 2004;23:53-62.
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 53-62
    • Saha, P.K.1    Wehrli, F.W.2
  • 29
    • 0016242145 scopus 로고
    • The quantitative morphology of anisotropic trabecular bone
    • Whitehouse WJ. The quantitative morphology of anisotropic trabecular bone. J Microsc 1974;101(Pt 2):153-168.
    • (1974) J Microsc , vol.101 , Issue.PART 2 , pp. 153-168
    • Whitehouse, W.J.1
  • 30
    • 0032188843 scopus 로고    scopus 로고
    • A global relationship between trabecular bone morphology and homogenized elastic properties
    • Zysset PK, Goulet RW, Hollister SJ. A global relationship between trabecular bone morphology and homogenized elastic properties. J Biomech Eng 1998;120:640-646. (Pubitemid 28460800)
    • (1998) Journal of Biomechanical Engineering , vol.120 , Issue.5 , pp. 640-646
    • Zysset, P.K.1    Goulet, R.W.2    Hollister, S.J.3
  • 31
    • 33847656980 scopus 로고    scopus 로고
    • Spatial autocorrelation and mean intercept length analysis of trabecular bone anisotropy applied to in vivo magnetic resonance imaging
    • DOI 10.1118/1.2437281
    • Wald MJ, Vasilic B, Saha PK, Wehrli FW. Spatial autocorrelation and mean intercept length analysis of trabecular bone anisotropy applied to in vivo magnetic resonance imaging. Med Phys 2007; 34:1110-1120. (Pubitemid 46355645)
    • (2007) Medical Physics , vol.34 , Issue.3 , pp. 1110-1120
    • Wald, M.J.1    Vasilic, B.2    Saha, P.K.3    Wehrli, F.W.4
  • 33
    • 77951585230 scopus 로고
    • Transformed correlations
    • Chapter 6. London: Oliver and Boyd
    • Fisher RA. Transformed correlations, Chapter 6. In: Statistical methods for research workers. London: Oliver and Boyd; 1925. p 162-175.
    • (1925) Statistical Methods for Research Workers , pp. 162-175
    • Fisher, R.A.1
  • 34
    • 0031907230 scopus 로고    scopus 로고
    • Quantitation of intrinsic magnetic susceptibilityrelated effects in a tissue matrix. Phantom study
    • Yablonskiy DA. Quantitation of intrinsic magnetic susceptibilityrelated effects in a tissue matrix. Phantom study. Magn Reson Med 1998;39:417-428.
    • (1998) Magn Reson Med , vol.39 , pp. 417-428
    • Yablonskiy, D.A.1
  • 35
    • 2942754052 scopus 로고    scopus 로고
    • Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia
    • DOI 10.1016/j.bone.2004.02.017, PII S8756328204000870
    • Gomberg BR, Wehrli FW, Vasilic B, et al. Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia. Bone 2004;35:266-276. (Pubitemid 38789174)
    • (2004) Bone , vol.35 , Issue.1 , pp. 266-276
    • Gomberg, B.R.1    Wehrli, F.W.2    Vasilic, B.3    Weening, R.H.4    Saha, P.K.5    Song, H.K.6    Wright, A.C.7
  • 37
    • 42049099742 scopus 로고    scopus 로고
    • In vivo magnetic resonance detects rapid remodeling changes in the topology of the trabecular bone network after menopause and the protective effect of estradiol
    • Wehrli FW, Ladinsky GA, Jones C, et al. In vivo magnetic resonance detects rapid remodeling changes in the topology of the trabecular bone network after menopause and the protective effect of estradiol. J Bone Miner Res 2008;23:730-740.
    • (2008) J Bone Miner Res , vol.23 , pp. 730-740
    • Wehrli, F.W.1    Ladinsky, G.A.2    Jones, C.3
  • 39
    • 0036245213 scopus 로고    scopus 로고
    • Processing and analysis of in vivo high-resolution MR images of trabecular bone for longitudinal studies: Reproducibility of structural measures and micro-finite element analysis derived mechanical properties
    • DOI 10.1007/s001980200027
    • Newitt DC, van Rietbergen B, Majumdar S. Processing and analysis of in vivo high-resolution MR images of trabecular bone for longitudinal studies: reproducibility of structural measures and micro-finite element analysis derived mechanical properties. Osteoporos Int 2002;13:278-287. (Pubitemid 34506736)
    • (2002) Osteoporosis International , vol.13 , Issue.4 , pp. 278-287
    • Newitt, D.C.1    Van Rietbergen, B.2    Majumdar, S.3
  • 40
    • 0022672008 scopus 로고
    • Wolff's law of trabecular architecture at remodeling equilibrium
    • Cowin SC. Wolff's law of trabecular architecture at remodeling equilibrium. J Biomech Eng 1986;108:83-88.
    • (1986) J Biomech Eng , vol.108 , pp. 83-88
    • Cowin, S.C.1
  • 42
    • 0022357694 scopus 로고
    • Correlation between the compressive strength of iliac and vertebral trabecular bone in normal individuals
    • DOI 10.1016/8756-3282(85)90317-5
    • Mosekilde L, Viidik A, Mosekilde L. Correlation between the compressive strength of iliac and vertebral trabecular bone in normal individuals. Bone 1985;6:291-295. (Pubitemid 16184986)
    • (1985) Bone , vol.6 , Issue.5 , pp. 291-295
    • Mosekilde, L.1    Vildik, A.2    Mosekilde, L.3
  • 43
    • 56749158485 scopus 로고    scopus 로고
    • Implications of resolution and noise for in vivo micro-MRI of trabecular bone
    • Li CQ, Magland JF, Rajapakse CS, et al. Implications of resolution and noise for in vivo micro-MRI of trabecular bone. Med Phys 2008;35:5584-5594.
    • (2008) Med Phys , vol.35 , pp. 5584-5594
    • Li, C.Q.1    Magland, J.F.2    Rajapakse, C.S.3
  • 44
    • 27444442617 scopus 로고    scopus 로고
    • Feasibility of in vivo structural analysis of high-resolution magnetic resonance images of the proximal femur
    • DOI 10.1007/s00198-005-1907-3
    • Krug R, Banerjee S, Han ET, Newitt DC, Link TM, Majumdar S. Feasibility of in vivo structural analysis of high-resolution magnetic resonance images of the proximal femur. Osteoporos Int 2005;16:1307-1314. (Pubitemid 41532082)
    • (2005) Osteoporosis International , vol.16 , Issue.11 , pp. 1307-1314
    • Krug, R.1    Banerjee, S.2    Han, E.T.3    Newitt, D.C.4    Link, T.M.5    Majumdar, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.