메뉴 건너뛰기




Volumn 17, Issue 1, 2011, Pages 7-14

A dry release of polyimide electrodes using Kapton film and application to EEG signal measurements

Author keywords

[No Author keywords available]

Indexed keywords

COMPLEX PROCESSES; CURING PROCESS; EEG SIGNALS; ELECTRICAL PROPERTY; HUMAN MESENCHYMAL STEM CELLS (HMSCS); IMPLANTABLE ELECTRODES; KAPTON FILMS; MOUSE-FIBROBLASTS; MULTICHANNEL EEG; NOVEL METHODS; SACRIFICIAL LAYER; SI WAFER;

EID: 79251647112     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-010-1152-3     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 77950977120 scopus 로고    scopus 로고
    • Polyimide-based multi-channel arrayed electrode for measuring EEG signal on the skull of mouse
    • Minneapolis, Minnesota, USA, September 2-6, 2009-Oral
    • Baek D-H, Lee E-J, Moon J-H, Choi J-H, Pak JJ-H, Lee S-H (2009) Polyimide-based multi-channel arrayed electrode for measuring EEG signal on the skull of mouse. In: 31st annual international conference of the IEEE EMBS Minneapolis, Minnesota, USA, September 2-6, 2009-Oral:7022-7025
    • (2009) 31st Annual International Conference of the IEEE EMBS , pp. 7022-7025
    • Baek, D.-H.1    Lee, E.-J.2    Moon, J.-H.3    Choi, J.-H.4    Jj-H, P.5    Lee, S.-H.6
  • 3
    • 33846585141 scopus 로고    scopus 로고
    • Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
    • DOI 10.1016/j.bios.2006.08.035, PII S0956566306004039
    • K Cheung P Renaud H Tanila K Djupsund 2007 Flexible polyimide microelectrode array for in vivo recordings and current source density analysis Biosens Bioelectron 22 8 1783 1790 10.1016/j.bios.2006.08.035 (Pubitemid 46185980)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.8 , pp. 1783-1790
    • Cheung, K.C.1    Renaud, P.2    Tanila, H.3    Djupsund, K.4
  • 4
    • 48049103241 scopus 로고    scopus 로고
    • A flexible multichannel electrode for mouse brain and its application to mouse EEG
    • Hangzhou, China, 12-14 October 2007
    • Choi J, Lee M, Kim J, Shin H (2007) A flexible multichannel electrode for mouse brain and its application to mouse EEG. In: Proceedings of NFSI & ICFBI 2007, Hangzhou, China, 12-14 October 2007, pp 230-231
    • (2007) Proceedings of NFSI & ICFBI 2007 , pp. 230-231
    • Choi, J.1    Lee, M.2    Kim, J.3    Shin, H.4
  • 6
    • 0030676638 scopus 로고    scopus 로고
    • Surface properties of chemically modified polyimide films
    • 10.1163/156856197X00967
    • I Ghosh J Konar A Bhowmick 1997 Surface properties of chemically modified polyimide films J Adhes Sci Technol 11 6 877 893 10.1163/156856197X00967
    • (1997) J Adhes Sci Technol , vol.11 , Issue.6 , pp. 877-893
    • Ghosh, I.1    Konar, J.2    Bhowmick, A.3
  • 7
    • 57349108564 scopus 로고    scopus 로고
    • Robust, conducting, and transparent polymer composites using surface-modified and individualized double-walled carbon nanotubes
    • 10.1002/adma.200801659
    • Y Jung D Shimamoto H Muramatsu Y Kim T Hayashi M Terrones M Endo 2008 Robust, conducting, and transparent polymer composites using surface-modified and individualized double-walled carbon nanotubes Adv Mat 20 23 4509 4512 10.1002/adma.200801659
    • (2008) Adv Mat , vol.20 , Issue.23 , pp. 4509-4512
    • Jung, Y.1    Shimamoto, D.2    Muramatsu, H.3    Kim, Y.4    Hayashi, T.5    Terrones, M.6    Endo, M.7
  • 8
    • 0029153664 scopus 로고
    • Injections of muscimol into the median raphe nucleus produce hippocampal theta rhythm in the urethane anesthetized rat
    • 10.1007/BF02311170
    • G Kinney B Kocsis R Vertes 1995 Injections of muscimol into the median raphe nucleus produce hippocampal theta rhythm in the urethane anesthetized rat Psychopharmacology 120 3 244 248 10.1007/BF02311170
    • (1995) Psychopharmacology , vol.120 , Issue.3 , pp. 244-248
    • Kinney, G.1    Kocsis, B.2    Vertes, R.3
  • 9
    • 62249157755 scopus 로고    scopus 로고
    • Fabrication of long and discontinuous natural fiber reinforced polypropylene biocomposites and their mechanical properties
    • 10.1007/s12221-009-0083-z
    • B Lee H Kim W Yu 2009 Fabrication of long and discontinuous natural fiber reinforced polypropylene biocomposites and their mechanical properties Fibers Polym 10 1 83 90 10.1007/s12221-009-0083-z
    • (2009) Fibers Polym , vol.10 , Issue.1 , pp. 83-90
    • Lee, B.1    Kim, H.2    Yu, W.3
  • 10
    • 33645687977 scopus 로고    scopus 로고
    • Water-soluble sacrificial layers for surface micromachining
    • DOI 10.1002/smll.200400159
    • V Linder B Gates D Ryan B Parviz G Whitesides 2005 Water-soluble sacrificial layers for surface micromachining Small 1 7 730 736 10.1002/smll.200400159 (Pubitemid 43951733)
    • (2005) Small , vol.1 , Issue.7 , pp. 730-736
    • Linder, V.1    Gates, B.D.2    Ryan, D.3    Parviz, B.A.4    Whitesides, G.M.5
  • 11
    • 33751112010 scopus 로고    scopus 로고
    • A laser release method for producing prototype flexible retinal implant devices
    • DOI 10.1016/j.sna.2006.02.035, PII S0924424706001397
    • N MacCarthy T Wood H Ameri D O'Connell J Alderman 2006 A laser release method for producing prototype flexible retinal implant devices Sens Actuators A Phys 132 1 296 301 10.1016/j.sna.2006.02.035 (Pubitemid 44764948)
    • (2006) Sensors and Actuators, A: Physical , vol.132 , Issue.SPEC. ISS. 1 , pp. 296-301
    • MacCarthy, N.1    Wood, T.2    Ameri, H.3    O'Connell, D.4    Alderman, J.5
  • 12
    • 18844432122 scopus 로고    scopus 로고
    • Partial release and detachment of microfabricated metal and polymer structures by anodic metal dissolution
    • DOI 10.1109/JMEMS.2004.839328
    • S Metz A Bertsch P Renaud A Technol A Dyconex S Bassersdorf 2005 Partial release and detachment of microfabricated metal and polymer structures by anodic metal dissolution J Microelectromech Syst 14 2 383 391 10.1109/JMEMS.2004. 839328 (Pubitemid 40679628)
    • (2005) Journal of Microelectromechanical Systems , vol.14 , Issue.2 , pp. 383-391
    • Metz, S.1    Bertsch, A.2    Renaud, P.3
  • 13
    • 12944280406 scopus 로고    scopus 로고
    • Retina implant - A bioMEMS challenge
    • DOI 10.1016/S0924-4247(01)00807-X, PII S092442470100807X
    • J Meyer 2002 Retina implant-a bioMEMS challenge Sens Actuators A Phys 97 1 9 10.1016/S0924-4247(01)00807-X (Pubitemid 34758704)
    • (2002) Sensors and Actuators, A: Physical , vol.97-98 , pp. 1-9
    • Meyer, J.-U.1
  • 15
    • 37349091594 scopus 로고    scopus 로고
    • The Development of Brain-Machine Interface Neuroprosthetic Devices
    • DOI 10.1016/j.nurt.2007.11.002, PII S1933721307002620, Device Therapy
    • P Patil D Turner 2008 The development of brain-machine interface neuroprosthetic devices Neurotherapeutics 5 1 137 146 10.1016/j.nurt.2007.11.002 (Pubitemid 350299307)
    • (2008) Neurotherapeutics , vol.5 , Issue.1 , pp. 137-146
    • Patil, P.G.1    Turner, D.A.2
  • 16
    • 0025405495 scopus 로고
    • Electrical properties of metallic electrodes
    • 10.1007/BF02441775
    • T Ragheb L Geddes 1990 Electrical properties of metallic electrodes Med Biol Eng Comput 28 2 182 186 10.1007/BF02441775
    • (1990) Med Biol Eng Comput , vol.28 , Issue.2 , pp. 182-186
    • Ragheb, T.1    Geddes, L.2
  • 17
    • 0027627674 scopus 로고
    • Polyimides as biomaterials: Preliminary biocompatibility testing
    • DOI 10.1016/0142-9612(93)90183-3
    • R Richardson Jr J Miller W Reichert 1993 Polyimides as biomaterials: preliminary biocompatibility testing Biomaterials 14 8 627 10.1016/0142-9612(93) 90183-3 (Pubitemid 23219810)
    • (1993) Biomaterials , vol.14 , Issue.8 , pp. 627-635
    • Richardson Jr., R.R.1    Miller, J.A.2    Reichert, W.M.3
  • 20
    • 0018163887 scopus 로고
    • Histopathological evaluation of materials implanted in the cerebral cortex
    • DOI 10.1007/BF00689766
    • S Stensaas L Stensaas 1978 Histopathological evaluation of materials implanted in the cerebral cortex Acta Neuropathol 41 2 145 155 10.1007/BF00689766 (Pubitemid 9011217)
    • (1978) Acta Neuropathologica , vol.41 , Issue.2 , pp. 145-155
    • Stensaas, S.S.1    Stensaas, L.J.2
  • 21
    • 0031144384 scopus 로고    scopus 로고
    • A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves
    • 10.1016/S0924-4247(97)01494-5
    • T Stieglitz H Beutel J Meyer 1997 A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves Sens Actuators A Phys 60 1-3 240 243 10.1016/S0924-4247(97)01494-5
    • (1997) Sens Actuators A Phys , vol.60 , Issue.13 , pp. 240-243
    • Stieglitz, T.1    Beutel, H.2    Meyer, J.3
  • 22
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined, polyimide-based devices for flexible neural interfaces
    • 10.1023/A:1009955222114
    • T Stieglitz H Beutel M Schuettler J Meyer 2000 Micromachined, polyimide-based devices for flexible neural interfaces Biomed Microdevices 2 4 283 294 10.1023/A:1009955222114
    • (2000) Biomed Microdevices , vol.2 , Issue.4 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.4
  • 23
    • 0030361491 scopus 로고    scopus 로고
    • Surface micromachining by sacrificial aluminium etching
    • 10.1088/0960-1317/6/4/004
    • D Westberg O Paul G Andersson H Baltes 1996 Surface micromachining by sacrificial aluminium etching J Micromech Microeng 6 376 384 10.1088/0960-1317/6/4/004
    • (1996) J Micromech Microeng , vol.6 , pp. 376-384
    • Westberg, D.1    Paul, O.2    Andersson, G.3    Baltes, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.