메뉴 건너뛰기




Volumn 69, Issue 6, 2010, Pages 1545-1551

Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humeral fractures: Radiographic analysis of a prospective randomized study

Author keywords

Angular stable plating; Loss of fixation; Monoaxial; Polyaxial; Proximal humeral fracture; Screw cut out; Secondary fracture displacement

Indexed keywords

AGE; AGED; ANTERIOR POSTERIOR AXIS; ARTICLE; BONE NECROSIS; BONE SCREW; CONTROLLED STUDY; DISEASE CLASSIFICATION; FEMALE; FRACTURE NONUNION; HAND RADIOGRAPHY; HUMAN; HUMERUS FRACTURE; MAJOR CLINICAL STUDY; MALE; MONOAXIAL SCREW INSERTION; ORTHOPEDIC SURGERY; PLATE FIXATION; POLYAXIAL SCREW INSERTION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; RANDOMIZED CONTROLLED TRIAL; VARUS DEFORMITY;

EID: 78650821380     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e3181c9b8a7     Document Type: Article
Times cited : (51)

References (28)
  • 1
    • 0142230911 scopus 로고    scopus 로고
    • First clinical results of the Locking Compression Plate (LCP)
    • Sommer C, Gautier E, Muller M, Helfet DL, Wagner M. First clinical results of the Locking Compression Plate (LCP). Injury. 2003;34 (suppl 2): B43-B54.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Sommer, C.1    Gautier, E.2    Muller, M.3    Helfet, D.L.4    Wagner, M.5
  • 3
    • 33749562322 scopus 로고    scopus 로고
    • Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques
    • Edwards SL, Wilson NA, Zhang LQ, Flores S, Merk BR. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. J Bone Joint Surg Am. 2006;88:2258-2264.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 2258-2264
    • Edwards, S.L.1    Wilson, N.A.2    Zhang, L.Q.3    Flores, S.4    Merk, B.R.5
  • 4
    • 10944263139 scopus 로고    scopus 로고
    • Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for a minimum of 1 year
    • Bjorkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand. 2004;75:741-745.
    • (2004) Acta Orthop Scand , vol.75 , pp. 741-745
    • Bjorkenheim, J.M.1    Pajarinen, J.2    Savolainen, V.3
  • 5
    • 33748957058 scopus 로고    scopus 로고
    • Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: Comparison using cadaveric and synthetic humeri
    • Siffri PC, Peindl RD, Coley ER, Norton J, Connor PM, Kellam JF. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma. 2006;20:547-554.
    • (2006) J Orthop Trauma , vol.20 , pp. 547-554
    • Siffri, P.C.1    Peindl, R.D.2    Coley, E.R.3    Norton, J.4    Connor, P.M.5    Kellam, J.F.6
  • 6
    • 0037279050 scopus 로고    scopus 로고
    • Locking plate osteosynthesis for fractures of the proximal humerus
    • Lungershausen W, Bach O, Lorenz CO. [Locking plate osteosynthesis for fractures of the proximal humerus]. Zentralbl Chir. 2003;128:28-33.
    • (2003) Zentralbl Chir , vol.128 , pp. 28-33
    • Lungershausen, W.1    Bach, O.2    Lorenz, C.O.3
  • 7
    • 33845958580 scopus 로고    scopus 로고
    • Locked vs. unlocked plate osteosynthesis of the proximal humerus - A biomechanical study
    • Seide K, Triebe J, Faschingbauer M, et al. Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study. Clin Biomech (Bristol, Avon). 2007;22:176-82.
    • (2007) Clin Biomech (Bristol, Avon) , vol.22 , pp. 176-82
    • Seide, K.1    Triebe, J.2    Faschingbauer, M.3
  • 8
    • 33750309100 scopus 로고    scopus 로고
    • Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate
    • 872-874
    • Hessler C, Schmucker U, Matthes G, Ekkernkamp A, Gütschow R, Eggers C. [Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate]. Unfallchirurg. 2006;109:867- 870, 872-874.
    • (2006) Unfallchirurg , vol.109 , pp. 867-870
    • Hessler, C.1    Schmucker, U.2    Matthes, G.3    Ekkernkamp, A.4    Gütschow, R.5    Eggers, C.6
  • 10
    • 38949093593 scopus 로고    scopus 로고
    • Internal fixation of unstable proximal humerus fractures with an anatomically preshaped interlocking plate: A clinical and radiologic evaluation
    • Hirschmann MT, Quarz V, Audige L, et al. Internal fixation of unstable proximal humerus fractures with an anatomically preshaped interlocking plate: a clinical and radiologic evaluation. J Trauma. 2007;63:1314-1323.
    • (2007) J Trauma , vol.63 , pp. 1314-1323
    • Hirschmann, M.T.1    Quarz, V.2    Audige, L.3
  • 11
    • 38949117338 scopus 로고    scopus 로고
    • Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]
    • Owsley KC, Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg Am. 2008;90:233-240.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 233-240
    • Owsley, K.C.1    Gorczyca, J.T.2
  • 12
    • 34250881547 scopus 로고    scopus 로고
    • The Non-Contact Bridging Plate. A new fixed-angle device for the minimally-invasive treatment of fractures of the proximal humerus- technique and preliminary results
    • Roderer G, Gebhard F, Erhardt J, Al-Agha S, AbouElsoud M, Kinzl L. [The Non-Contact Bridging Plate. A new fixed-angle device for the minimally-invasive treatment of fractures of the proximal humerus- technique and preliminary results]. Unfallchirurg. 2007;110:505-512.
    • (2007) Unfallchirurg , vol.110 , pp. 505-512
    • Roderer, G.1    Gebhard, F.2    Erhardt, J.3    Al-Agha, S.4    Abouelsoud, M.5    Kinzl, L.6
  • 13
    • 33748436645 scopus 로고    scopus 로고
    • Proximal humeral fractures: Regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws
    • Tingart MJ, Lehtinen J, Zurakowski D, Warner JJ, Apreleva M. Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws. J Shoulder Elbow Surg. 2006;15:620-624.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 620-624
    • Tingart, M.J.1    Lehtinen, J.2    Zurakowski, D.3    Warner, J.J.4    Apreleva, M.5
  • 14
    • 0030818511 scopus 로고    scopus 로고
    • The three-dimensional geometry of the proximal humerus. Implications for surgical technique and prosthetic design
    • Boileau P, Walch G. The three-dimensional geometry of the proximal humerus. Implications for surgical technique and prosthetic design. J Bone Joint Surg Br. 1997;79(5):857-65.
    • (1997) J Bone Joint Surg Br , vol.79 , Issue.5 , pp. 857-65
    • Boileau, P.1    Walch, G.2
  • 15
    • 0142166152 scopus 로고    scopus 로고
    • Where should implants be anchored in the humeral head?
    • Hepp P, Lill H, Bail H, et al. Where should implants be anchored in the humeral head? Clin Orthop Relat Res. 2003:139-147.
    • (2003) Clin Orthop Relat Res , pp. 139-147
    • Hepp, P.1    Lill, H.2    Bail, H.3
  • 16
    • 35948976112 scopus 로고    scopus 로고
    • Analysis of efficacy and failure in proximal humerus fractures treated with locking plates
    • Agudelo J, Schurmann M, Stahel P, et al. Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma. 2007;21:676-681.
    • (2007) J Orthop Trauma , vol.21 , pp. 676-681
    • Agudelo, J.1    Schurmann, M.2    Stahel, P.3
  • 17
    • 0029870080 scopus 로고    scopus 로고
    • The epidemiology of peripheral fractures
    • Baron JA, Barrett JA, Karagas MR. The epidemiology of peripheral fractures. Bone. 1996;18 (3 suppl):209S-13S.
    • (1996) Bone , vol.18 , Issue.3 SUPPL.
    • Baron, J.A.1    Barrett, J.A.2    Karagas, M.R.3
  • 18
    • 33745994558 scopus 로고    scopus 로고
    • Epidemiology of adult fractures: A review
    • Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37:691-697.
    • (2006) Injury , vol.37 , pp. 691-697
    • Court-Brown, C.M.1    Caesar, B.2
  • 19
    • 0032104660 scopus 로고    scopus 로고
    • Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients
    • Zyto K. Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients. Injury. 1998;29:349-352.
    • (1998) Injury , vol.29 , pp. 349-352
    • Zyto, K.1
  • 20
    • 0032196935 scopus 로고    scopus 로고
    • The clinical relevance of posttraumatic avascular necrosis of the humeral head
    • Gerber C, Hersche O, Berberat C. The clinical relevance of posttraumatic avascular necrosis of the humeral head. J Shoulder Elbow Surg. 1998;7:586-590.
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 586-590
    • Gerber, C.1    Hersche, O.2    Berberat, C.3
  • 21
    • 3042517110 scopus 로고    scopus 로고
    • Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus
    • Hertel R, Hempfing A, Stiehler M, et al. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elbow Surg. 2004;13:427-433.
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 427-433
    • Hertel, R.1    Hempfing, A.2    Stiehler, M.3
  • 22
    • 0037396463 scopus 로고    scopus 로고
    • Rehabilitation after two-part fractures of the neck of the humerus
    • Hodgson SA, Mawson SJ, Stanley D. Rehabilitation after two-part fractures of the neck of the humerus. J Bone Joint Surg Br. 2003;85: 419-422.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 419-422
    • Hodgson, S.A.1    Mawson, S.J.2    Stanley, D.3
  • 23
    • 22544468510 scopus 로고    scopus 로고
    • Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    • Hessmann MH, Hansen WS, Krummenauer F, Pol TF, Rommens PM. Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation. J Trauma. 2005;58:1194-1201.
    • (2005) J Trauma , vol.58 , pp. 1194-1201
    • Hessmann, M.H.1    Hansen, W.S.2    Krummenauer, F.3    Pol, T.F.4    Rommens, P.M.5
  • 24
    • 33644678764 scopus 로고    scopus 로고
    • Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fractures
    • Weinstein DM, Bratton DR, Ciccone WJ II, Elias JJ. Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fractures. J Shoulder Elbow Surg. 2006;15:239-243.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 239-243
    • Weinstein, D.M.1    Bratton, D.R.2    Ciccone, I.I.W.J.3    Elias, J.J.4
  • 26
    • 33845874389 scopus 로고    scopus 로고
    • Treatment of proximal humeral fractures with the PHILOS angular stable plate. Presentation of 225 cases of dislocated fractures
    • Kettler M, Biberthaler P, Braunstein V, Zeiler C, Kroetz M, Mutschler W. [Treatment of proximal humeral fractures with the PHILOS angular stable plate. Presentation of 225 cases of dislocated fractures.] Unfallchirurg. 2006;109:1032-1040.
    • (2006) Unfallchirurg , vol.109 , pp. 1032-1040
    • Kettler, M.1    Biberthaler, P.2    Braunstein, V.3    Zeiler, C.4    Kroetz, M.5    Mutschler, W.6
  • 27
    • 0142119539 scopus 로고    scopus 로고
    • Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry
    • Mattsson P, Larsson S. Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry. Scand J Surg. 2003;92:215-219.
    • (2003) Scand J Surg , vol.92 , pp. 215-219
    • Mattsson, P.1    Larsson, S.2
  • 28
    • 33845905793 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures
    • von der Linden P, Gisep A, Boner V, Windolf M, Appelt A, Suhm N. Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures. J Orthop Res. 2006;24:2230-2237.
    • (2006) J Orthop Res , vol.24 , pp. 2230-2237
    • Von Der Linden, P.1    Gisep, A.2    Boner, V.3    Windolf, M.4    Appelt, A.5    Suhm, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.