메뉴 건너뛰기




Volumn 430, Issue , 2005, Pages 176-181

A new locking plate for unstable fractures of the proximal humerus

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE NECROSIS; BONE PLATE; BONE RADIOGRAPHY; CLINICAL ARTICLE; COHORT ANALYSIS; DISEASE CLASSIFICATION; FEMALE; FRACTURE NONUNION; HUMAN; HUMERUS FRACTURE; IMPLANT; MALE; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SCORING SYSTEM; SURGICAL TECHNIQUE; TREATMENT OUTCOME; TREATMENT PLANNING;

EID: 11844254362     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/01.blo.0000137554.91189.a9     Document Type: Article
Times cited : (268)

References (27)
  • 1
    • 0027520913 scopus 로고
    • Vascularity of the humeral head after proximal humeral fractures: An anatomical cadaver study
    • Brooks CH, Revell WJ, Heatley FW: Vascularity of the humeral head after proximal humeral fractures: An anatomical cadaver study. J Bone Joint Surg 758:132-136, 1993.
    • (1993) J Bone Joint Surg , vol.758 , pp. 132-136
    • Brooks, C.H.1    Revell, W.J.2    Heatley, F.W.3
  • 2
    • 0023115201 scopus 로고
    • A clinical method of functional assessment of the shoulder
    • Constant CR, Murley AH: A clinical method of functional assessment of the shoulder. Clin Orthop 214:160-164, 1987.
    • (1987) Clin Orthop , vol.214 , pp. 160-164
    • Constant, C.R.1    Murley, A.H.2
  • 3
    • 0028183176 scopus 로고
    • Tension-band wiring supplemented by lag-screw fixation of proximal humerus fractures: A modified technique
    • Cornell CN: Tension-band wiring supplemented by lag-screw fixation of proximal humerus fractures: A modified technique. Orthop Rev Suppl: May:19-23, 1994.
    • (1994) Orthop Rev Suppl , vol.MAY , pp. 19-23
    • Cornell, C.N.1
  • 4
    • 0034220456 scopus 로고    scopus 로고
    • A new internal fixation technique for fractures of the proximal humerus: The Bilboquet device: A report on 26 cases
    • Doursounian L, Grimberg J, Cazeau C, Jos E, Touzard RC: A new internal fixation technique for fractures of the proximal humerus: The Bilboquet device: A report on 26 cases. J Shoulder Elbow Surg 9:279-288, 2000.
    • (2000) J Shoulder Elbow Surg , vol.9 , pp. 279-288
    • Doursounian, L.1    Grimberg, J.2    Cazeau, C.3    Jos, E.4    Touzard, R.C.5
  • 5
    • 0041318956 scopus 로고    scopus 로고
    • Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer Type 3)
    • Fankhauser F, Schippinger G, Weber K, et al: Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer Type 3). J Trauma 55:345-349, 2003.
    • (2003) J Trauma , vol.55 , pp. 345-349
    • Fankhauser, F.1    Schippinger, G.2    Weber, K.3
  • 6
    • 10644243673 scopus 로고    scopus 로고
    • Locking Compression Plate (LCP): An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)
    • Frigg R: Locking Compression Plate (LCP): An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix). Injury 32:63-66, 2001.
    • (2001) Injury , vol.32 , pp. 63-66
    • Frigg, R.1
  • 7
    • 0032196935 scopus 로고    scopus 로고
    • The clinical relevance of post-traumatic avascular necrosis of the humeral head
    • Gerber C, Hersche O, Berberat C: The clinical relevance of post-traumatic avascular necrosis of the humeral head. J Shoulder Elbow Surg 7:586-590, 1998.
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 586-590
    • Gerber, C.1    Hersche, O.2    Berberat, C.3
  • 8
    • 0033395973 scopus 로고    scopus 로고
    • Experimental comparative study of 3 systems of osteosynthesis for proximal humeral fractures: Preliminary study of the mechanical properties of conserved trabecular bone
    • Gicquel P, Bonnomet F, Boutemy P, Schlemmer B, Kempf JF: Experimental comparative study of 3 systems of osteosynthesis for proximal humeral fractures: Preliminary study of the mechanical properties of conserved trabecular bone. Rev Chir Orthop Reparatrice Appar Mot 85:811-820, 1999.
    • (1999) Rev Chir Orthop Reparatrice Appar Mot , vol.85 , pp. 811-820
    • Gicquel, P.1    Bonnomet, F.2    Boutemy, P.3    Schlemmer, B.4    Kempf, J.F.5
  • 9
    • 0033646587 scopus 로고    scopus 로고
    • Rigid internal fixation of fracture of the proximal humerus in older patients
    • Hintermann B, Trouillier HH, Schäfer D: Rigid internal fixation of fracture of the proximal humerus in older patients. J Bone Joint Surg 82B: 1107-1112, 2000.
    • (2000) J Bone Joint Surg , vol.82 B , pp. 1107-1112
    • Hintermann, B.1    Trouillier, H.H.2    Schäfer, D.3
  • 10
    • 0026659303 scopus 로고
    • Percutaneous stabilization of unstable fractures of the humerus
    • Jaberg H, Warner JP, Jakob RP: Percutaneous stabilization of unstable fractures of the humerus. J Bone Joint Surg 74A:508-515, 1992.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 508-515
    • Jaberg, H.1    Warner, J.P.2    Jakob, R.P.3
  • 11
    • 0000840082 scopus 로고    scopus 로고
    • Surgical neck fracture of the humerus with severe displacement: Factors related to union
    • Jones AR, Brashear HR, Dameron TB: Surgical neck fracture of the humerus with severe displacement: Factors related to union. Orthop Trans 11:457, 1997.
    • (1997) Orthop Trans , vol.11 , pp. 457
    • Jones, A.R.1    Brashear, H.R.2    Dameron, T.B.3
  • 12
    • 0030004494 scopus 로고    scopus 로고
    • Surgical neck fractures of the proximal humerus: A laboratory evaluation of ten fixation techniques
    • Koval KJ, Blair B, Takei R, Kummer FJ, Zuckermann JD: Surgical neck fractures of the proximal humerus: A laboratory evaluation of ten fixation techniques. J Trauma 40:778-783, 1996.
    • (1996) J Trauma , vol.40 , pp. 778-783
    • Koval, K.J.1    Blair, B.2    Takei, R.3    Kummer, F.J.4    Zuckermann, J.D.5
  • 13
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: How stiff should an implant be? A comparative mechanical study with new implants in human specimens
    • Lill H, Hepp P, Korner J, et al: Proximal humeral fractures: How stiff should an implant be?: A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 123:74-81, 2003.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3
  • 14
    • 0032694044 scopus 로고    scopus 로고
    • Axillary nerve injury
    • Perlmutter GS: Axillary nerve injury. Clin Orthop 368:28-36, 1999.
    • (1999) Clin Orthop , vol.368 , pp. 28-36
    • Perlmutter, G.S.1
  • 15
    • 0031880983 scopus 로고    scopus 로고
    • Assessment and managment of three- and four-part proximal humeral fractures
    • Rees J, Hicks J, Ribbans W: Assessment and managment of three- and four-part proximal humeral fractures. Clin Orthop 353:18-29, 1998.
    • (1998) Clin Orthop , vol.353 , pp. 18-29
    • Rees, J.1    Hicks, J.2    Ribbans, W.3
  • 16
    • 0029265336 scopus 로고
    • Reconstruction of the valgus-impacted humeral head fracture
    • Resch H, Beck E, Baley I: Reconstruction of the valgus-impacted humeral head fracture. J Shoulder Elbow Surg 4:73-80, 1995.
    • (1995) J Shoulder Elbow Surg , vol.4 , pp. 73-80
    • Resch, H.1    Beck, E.2    Baley, I.3
  • 17
    • 0030900964 scopus 로고    scopus 로고
    • Percutaneous fixation of three- and four-part fractures of the proximal humerus
    • Resch H, Povacz P, Fröhlich R, Wambacher M: Percutaneous fixation of three- and four-part fractures of the proximal humerus. J Bone Joint Surg 79B:295-300, 1997.
    • (1997) J Bone Joint Surg , vol.79 B , pp. 295-300
    • Resch, H.1    Povacz, P.2    Fröhlich, R.3    Wambacher, M.4
  • 19
    • 0030772086 scopus 로고    scopus 로고
    • Current concepts in the treatment of proximal humeral fractures
    • Schippinger G, Szyszkowitz R, Seibert FJ: Current concepts in the treatment of proximal humeral fractures. Curr Orthop 11:203-214, 1997.
    • (1997) Curr Orthop , vol.11 , pp. 203-214
    • Schippinger, G.1    Szyszkowitz, R.2    Seibert, F.J.3
  • 20
    • 0003062337 scopus 로고
    • Displaced proximal humeral fractures: Evaluation and treatment
    • Schlegel TF, Hawkins RJ: Displaced proximal humeral fractures: Evaluation and treatment. J Am Acad Orthop Surg 2:54-78, 1994.
    • (1994) J Am Acad Orthop Surg , vol.2 , pp. 54-78
    • Schlegel, T.F.1    Hawkins, R.J.2
  • 22
    • 0033217665 scopus 로고    scopus 로고
    • Transitory percutaneous pinning in fractures of the proximal humerus
    • Soete PJ, Clayson PE, Costenoble VH: Transitory percutaneous pinning in fractures of the proximal humerus. J Shoulder Elbow Surg 8:569-573, 1999.
    • (1999) J Shoulder Elbow Surg , vol.8 , pp. 569-573
    • Soete, P.J.1    Clayson, P.E.2    Costenoble, V.H.3
  • 23
    • 0027163797 scopus 로고
    • Proximal humeral fractures: Management techniques and expected results
    • Szyszkowitz R, Seggl W, Schleifer P, Cundy PJ: Proximal humeral fractures: Management techniques and expected results. Clin Orthop 292:13-25, 1993.
    • (1993) Clin Orthop , vol.292 , pp. 13-25
    • Szyszkowitz, R.1    Seggl, W.2    Schleifer, P.3    Cundy, P.J.4
  • 25
    • 0031619437 scopus 로고    scopus 로고
    • Surgical treatment of proximal humerus fractures-international multicenter study
    • in German
    • Weber E, Matter P: Surgical treatment of proximal humerus fractures-international multicenter study. Swiss Surg 4:95-100, 1998. [in German]
    • (1998) Swiss Surg , vol.4 , pp. 95-100
    • Weber, E.1    Matter, P.2
  • 26
    • 0031179758 scopus 로고    scopus 로고
    • Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation
    • Wheeler DL, Colville MR: Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation. J Orthop Trauma 11:363-367, 1997.
    • (1997) J Orthop Trauma , vol.11 , pp. 363-367
    • Wheeler, D.L.1    Colville, M.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.