메뉴 건너뛰기




Volumn 24, Issue 12, 2006, Pages 2230-2237

Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures

Author keywords

Cement augmentation; Cut out; High pressure irrigation; Hip fracture; Osteoporosis

Indexed keywords

POLY(METHYL METHACRYLATE);

EID: 33845905793     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.20299     Document Type: Article
Times cited : (66)

References (43)
  • 1
    • 0025034792 scopus 로고
    • Intertrochanteric femoral fractures. Mechanical failure after internal fixation
    • Davis TR, Sher JL, Horsman A, et al. 1990. Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg [Br] 72:26-31.
    • (1990) J Bone Joint Surg [Br] , vol.72 , pp. 26-31
    • Davis, T.R.1    Sher, J.L.2    Horsman, A.3
  • 2
    • 0018188643 scopus 로고
    • Unstable trochanteric fractures treated with the sliding screw-plate system. A biomechanical study of unstable trochanteric fractures. III
    • Jensen JS, Tondevold E, Mossing N. 1978. Unstable trochanteric fractures treated with the sliding screw-plate system. A biomechanical study of unstable trochanteric fractures. III. Acta Orthop Scand 49:392-397.
    • (1978) Acta Orthop Scand , vol.49 , pp. 392-397
    • Jensen, J.S.1    Tondevold, E.2    Mossing, N.3
  • 3
    • 0024580353 scopus 로고
    • Implant failures in patients with proximal fractures of the femur treated with a sliding screw device
    • Mainds CC, Newman RJ. 1989. Implant failures in patients with proximal fractures of the femur treated with a sliding screw device. Injury 20:98-100.
    • (1989) Injury , vol.20 , pp. 98-100
    • Mainds, C.C.1    Newman, R.J.2
  • 4
    • 0142227942 scopus 로고    scopus 로고
    • Mechanical failure of dynamic hip screw (DHS) fixation in intertrochanteric fracture of the femur
    • Nordin S, Zulkifli O, Faisham WI. 2001. Mechanical failure of dynamic hip screw (DHS) fixation in intertrochanteric fracture of the femur. Med J Malaysia 56(Suppl D):12-17.
    • (2001) Med J Malaysia , vol.56 , Issue.SUPPL. D , pp. 12-17
    • Nordin, S.1    Zulkifli, O.2    Faisham, W.I.3
  • 5
    • 0027196249 scopus 로고
    • Valgus reduction of trochanteric fractures
    • Parker MJ. 1993. Valgus reduction of trochanteric fractures. Injury 24:313-316.
    • (1993) Injury , vol.24 , pp. 313-316
    • Parker, M.J.1
  • 6
    • 0027582580 scopus 로고
    • Technical pitfalls in the use of the sliding hip screw for fixation of intertrochanteric hip fractures
    • Rokito AS, Koval KJ, Zuckerman JD. 1993. Technical pitfalls in the use of the sliding hip screw for fixation of intertrochanteric hip fractures. Contemp Orthop 26:349-356.
    • (1993) Contemp Orthop , vol.26 , pp. 349-356
    • Rokito, A.S.1    Koval, K.J.2    Zuckerman, J.D.3
  • 7
    • 0024328634 scopus 로고
    • Sliding hip screws: Modes of failure
    • Simpson AH, Varty K, Dodd CA. 1989. Sliding hip screws: modes of failure. Injury 20:227-231.
    • (1989) Injury , vol.20 , pp. 227-231
    • Simpson, A.H.1    Varty, K.2    Dodd, C.A.3
  • 8
    • 0016804873 scopus 로고
    • The use of methylmethacrylate as an adjunct in the internal fixation of unstable comminuted intertrochanteric fractures in osteoporotic patients
    • Harrington KD. 1975. The use of methylmethacrylate as an adjunct in the internal fixation of unstable comminuted intertrochanteric fractures in osteoporotic patients. J Bone Joint Surg [Am] 57:744-750.
    • (1975) J Bone Joint Surg [Am] , vol.57 , pp. 744-750
    • Harrington, K.D.1
  • 9
    • 2342554403 scopus 로고    scopus 로고
    • Osteoporotic femoral neck fractures: Management and current controversies
    • Gardner MJ, Lorich DG, Lane JM. 2004. Osteoporotic femoral neck fractures: management and current controversies. Instr Course Lect 53:427-439.
    • (2004) Instr Course Lect , vol.53 , pp. 427-439
    • Gardner, M.J.1    Lorich, D.G.2    Lane, J.M.3
  • 10
    • 2342612710 scopus 로고    scopus 로고
    • Osteoporotic pertrochanteric hip fractures: Management and current controversies
    • Lorich DG, Geller DS, Nielson JH. 2004. Osteoporotic pertrochanteric hip fractures: management and current controversies. Instr Course Lect 53:441-454.
    • (2004) Instr Course Lect , vol.53 , pp. 441-454
    • Lorich, D.G.1    Geller, D.S.2    Nielson, J.H.3
  • 11
    • 0027501518 scopus 로고
    • Hip fractures: A worldwide problem today and tomorrow
    • Melton LJ III. 1993. Hip fractures: a worldwide problem today and tomorrow. Bone 14(Suppl 1):S1-S8.
    • (1993) Bone , vol.14 , Issue.SUPPL. 1
    • Melton III, L.J.1
  • 12
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, et al. 1995. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg [Am] 77:1058-1064.
    • (1995) J Bone Joint Surg [Am] , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 13
    • 0030720275 scopus 로고    scopus 로고
    • Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    • Baumgaertner MR, Solberg BD. 1997. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg [Br] 79:969-971.
    • (1997) J Bone Joint Surg [Br] , vol.79 , pp. 969-971
    • Baumgaertner, M.R.1    Solberg, B.D.2
  • 14
    • 4444241897 scopus 로고    scopus 로고
    • Prediction of fixation failure after sliding hip screw fixation
    • Pervez H, Parker MJ, Vowler S. 2004. Prediction of fixation failure after sliding hip screw fixation. Injury 35:994-998.
    • (2004) Injury , vol.35 , pp. 994-998
    • Pervez, H.1    Parker, M.J.2    Vowler, S.3
  • 15
    • 0036096934 scopus 로고    scopus 로고
    • A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures
    • Augat P, Rapp S, Claes L. 2002. A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma 16:311-316.
    • (2002) J Orthop Trauma , vol.16 , pp. 311-316
    • Augat, P.1    Rapp, S.2    Claes, L.3
  • 16
    • 0021885570 scopus 로고
    • The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis
    • Bartucci EJ, Gonzalez MH, Cooperman DR, et al. 1985. The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis. J Bone Joint Surg [Am] 67:1094-1107.
    • (1985) J Bone Joint Surg [Am] , vol.67 , pp. 1094-1107
    • Bartucci, E.J.1    Gonzalez, M.H.2    Cooperman, D.R.3
  • 17
    • 0028967034 scopus 로고
    • Biomechanical comparison of the sliding hip screw and the dome plunger. Effects of material and fixation design
    • Choueka J, Koval KJ, Kummer FJ, et al. 1995. Biomechanical comparison of the sliding hip screw and the dome plunger. Effects of material and fixation design. J Bone Joint Surg [Br] 77:277-283.
    • (1995) J Bone Joint Surg [Br] , vol.77 , pp. 277-283
    • Choueka, J.1    Koval, K.J.2    Kummer, F.J.3
  • 18
    • 0034251703 scopus 로고    scopus 로고
    • Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures
    • Elder S, Frankenburg E, Goulet J, et al. 2000. Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures. J Orthop Trauma 14:386-393.
    • (2000) J Orthop Trauma , vol.14 , pp. 386-393
    • Elder, S.1    Frankenburg, E.2    Goulet, J.3
  • 19
    • 0036096933 scopus 로고    scopus 로고
    • The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices
    • Eriksson F, Mattsson P, Larsson S. 2002. The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices. J Orthop Trauma 16:302-310.
    • (2002) J Orthop Trauma , vol.16 , pp. 302-310
    • Eriksson, F.1    Mattsson, P.2    Larsson, S.3
  • 20
    • 2942626200 scopus 로고    scopus 로고
    • Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: A biomechanical investigation of PMMA reinforcement in cadaver bones
    • Heini PF, Franz T, Fankhauser C, et al. 2004. Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones. Clin Biomech (Bristol, Avon) 19:506-512.
    • (2004) Clin Biomech (Bristol, Avon) , vol.19 , pp. 506-512
    • Heini, P.F.1    Franz, T.2    Fankhauser, C.3
  • 21
    • 0036169004 scopus 로고    scopus 로고
    • Use of injectable calcium phosphate cement for fracture fixation: A review
    • Larsson S, Bauer TW. 2002. Use of injectable calcium phosphate cement for fracture fixation: a review. Clin Orthop 395:23-32.
    • (2002) Clin Orthop , vol.395 , pp. 23-32
    • Larsson, S.1    Bauer, T.W.2
  • 22
    • 25844441716 scopus 로고    scopus 로고
    • Resorbable cement for the augmentation of internally-fixed unstable trochanteric fractures: A prospective, randomised multicentre study
    • Mattsson P, Alberts A, Dahlberg G, et al. 2005. Resorbable cement for the augmentation of internally-fixed unstable trochanteric fractures: a prospective, randomised multicentre study. J Bone Joint Surg [Br] 87:1203-1209.
    • (2005) J Bone Joint Surg [Br] , vol.87 , pp. 1203-1209
    • Mattsson, P.1    Alberts, A.2    Dahlberg, G.3
  • 23
    • 0142119539 scopus 로고    scopus 로고
    • Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry
    • Mattsson P, Larsson S. 2003. Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry. Scand J Surg 92:215-219.
    • (2003) Scand J Surg , vol.92 , pp. 215-219
    • Mattsson, P.1    Larsson, S.2
  • 24
    • 8344276630 scopus 로고    scopus 로고
    • Unstable trochanteric fractures augmented with calcium phosphate cement. A prospective randomized study using radiostereometry to measure fracture stability
    • Mattsson P, Larsson S. 2004. Unstable trochanteric fractures augmented with calcium phosphate cement. A prospective randomized study using radiostereometry to measure fracture stability. Scand J Surg 93:223-228.
    • (2004) Scand J Surg , vol.93 , pp. 223-228
    • Mattsson, P.1    Larsson, S.2
  • 25
    • 0030250814 scopus 로고    scopus 로고
    • Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement
    • Stankewich CJ, Swiontkowski MF, Tencer AF, et al. 1996. Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement. J Orthop Res 14:786-793.
    • (1996) J Orthop Res , vol.14 , pp. 786-793
    • Stankewich, C.J.1    Swiontkowski, M.F.2    Tencer, A.F.3
  • 26
    • 0347286912 scopus 로고    scopus 로고
    • Prevention of hip lag screw cut-out by cement augmentation: Description of a new technique and preliminary clinical results
    • Szpalski M, Descamps PY, Hayez JP, et al. 2004. Prevention of hip lag screw cut-out by cement augmentation: description of a new technique and preliminary clinical results. J Orthop Trauma 18:34-40.
    • (2004) J Orthop Trauma , vol.18 , pp. 34-40
    • Szpalski, M.1    Descamps, P.Y.2    Hayez, J.P.3
  • 27
    • 0036266060 scopus 로고    scopus 로고
    • Mechanical evaluation of a carbonated apatite cement in the fixation of unstable intertrochanteric fractures
    • Yetkinler DN, Goodman SB, Reindel ES, et al. 2002. Mechanical evaluation of a carbonated apatite cement in the fixation of unstable intertrochanteric fractures. Acta Orthop Scand 73:157-164.
    • (2002) Acta Orthop Scand , vol.73 , pp. 157-164
    • Yetkinler, D.N.1    Goodman, S.B.2    Reindel, E.S.3
  • 28
    • 13444261294 scopus 로고    scopus 로고
    • Injection biomechanics of bone cements used in vertebroplasty
    • Baroud G, Bohner M, Heini P, et al. 2004. Injection biomechanics of bone cements used in vertebroplasty. Biomed Mater Eng 14:487-504.
    • (2004) Biomed Mater Eng , vol.14 , pp. 487-504
    • Baroud, G.1    Bohner, M.2    Heini, P.3
  • 29
    • 0033626539 scopus 로고    scopus 로고
    • Schraubenhalt-Verstärkung im Femurkopf durch Zementapplikation via Implantat - Eine biomechanische Studie
    • Kramer A, Angst M, Gasser B, et al. 2000. Schraubenhalt-Verstärkung im Femurkopf durch Zementapplikation via Implantat - eine biomechanische Studie. Z Orthop Ihre Grenzgeb 138:464-469.
    • (2000) Z Orthop Ihre Grenzgeb , vol.138 , pp. 464-469
    • Kramer, A.1    Angst, M.2    Gasser, B.3
  • 30
    • 0033755537 scopus 로고    scopus 로고
    • Lavage technique in total hip arthroplasty: Jet lavage produces better cement penetration than syringe lavage in the proximal femur
    • Breusch SJ, Norman TL, Schneider U, et al. 2000. Lavage technique in total hip arthroplasty: jet lavage produces better cement penetration than syringe lavage in the proximal femur. J Arthroplasty 15:921-927.
    • (2000) J Arthroplasty , vol.15 , pp. 921-927
    • Breusch, S.J.1    Norman, T.L.2    Schneider, U.3
  • 31
    • 0034091118 scopus 로고    scopus 로고
    • Einfluß der Zementiertechnik auf das Zementierergebnis am koxalen Femurende
    • Breusch SJ, Schneider U, Kreutzer J, et al. 2000. Einfluß der Zementiertechnik auf das Zementierergebnis am koxalen Femurende. Orthopäde 29:260-270.
    • (2000) Orthopäde , vol.29 , pp. 260-270
    • Breusch, S.J.1    Schneider, U.2    Kreutzer, J.3
  • 32
    • 0035097717 scopus 로고    scopus 로고
    • Die Bedeutung der Jet-Lavage f̈r das in-vitro und in-vivo-Zementierergebnis
    • Breusch SJ, Schneider U, Reitzel T, et al. 2001. Die Bedeutung der Jet-Lavage f̈r das in-vitro und in-vivo-Zementierergebnis. Z Orthop Ihre Grenzgeb 139:52-63.
    • (2001) Z Orthop Ihre Grenzgeb , vol.139 , pp. 52-63
    • Breusch, S.J.1    Schneider, U.2    Reitzel, T.3
  • 33
    • 0021363781 scopus 로고
    • Factors influencing the intrusion of methylmethacrylate into human tibiae
    • Dorr LD, Lindberg JP, Claude-Faugere M, et al. 1984. Factors influencing the intrusion of methylmethacrylate into human tibiae. Clin Orthop 183:147-152.
    • (1984) Clin Orthop , vol.183 , pp. 147-152
    • Dorr, L.D.1    Lindberg, J.P.2    Claude-Faugere, M.3
  • 34
    • 0020045552 scopus 로고
    • Strength of the cement-bone interface
    • Krause WR, Krug W, Miller J. 1982. Strength of the cement-bone interface. Clin Orthop 163:290-299.
    • (1982) Clin Orthop , vol.163 , pp. 290-299
    • Krause, W.R.1    Krug, W.2    Miller, J.3
  • 35
    • 0027399214 scopus 로고
    • Penetration and shear strength of cement-bone interfaces in vivo
    • MacDonald W, Swarts E, Beaver R. 1993. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop 286:283-288.
    • (1993) Clin Orthop , vol.286 , pp. 283-288
    • MacDonald, W.1    Swarts, E.2    Beaver, R.3
  • 36
    • 0028913298 scopus 로고
    • Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty
    • Maistrelli GL, Antonelli L, Fornasier V, et al. 1995. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop 312:261-265.
    • (1995) Clin Orthop , vol.312 , pp. 261-265
    • Maistrelli, G.L.1    Antonelli, L.2    Fornasier, V.3
  • 38
    • 0034131469 scopus 로고    scopus 로고
    • Irrigation and suction technique to ensure reliable cement penetration for total knee arthroplasty
    • Norton MR, Eyres KS. 2000. Irrigation and suction technique to ensure reliable cement penetration for total knee arthroplasty. J Arthroplasty 15:468-474.
    • (2000) J Arthroplasty , vol.15 , pp. 468-474
    • Norton, M.R.1    Eyres, K.S.2
  • 39
    • 0034801938 scopus 로고    scopus 로고
    • Einfluss der Femurmarkraumspülung auf die periprothetische Zementverteilung: Jet-Lavage versus Spritzenspülung
    • Wirtz D, Sellei RM, Portheine F, et al. 2001. Einfluss der Femurmarkraumspülung auf die periprothetische Zementverteilung: Jet-Lavage versus Spritzenspülung. Z Orthop Ihre Grenzgeb 139:410-414.
    • (2001) Z Orthop Ihre Grenzgeb , vol.139 , pp. 410-414
    • Wirtz, D.1    Sellei, R.M.2    Portheine, F.3
  • 40
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. 2001. Hip contact forces and gait patterns from routine activities. J Biomech 34:859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 41
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A. 1993. Hip joint loading during walking and running, measured in two patients. J Biomech 26:969-990.
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 42
    • 0024364323 scopus 로고
    • Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures
    • Cheng CL, Chow SP, Pun WK, et al. 1989. Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures. Injury 20:134-138.
    • (1989) Injury , vol.20 , pp. 134-138
    • Cheng, C.L.1    Chow, S.P.2    Pun, W.K.3
  • 43
    • 33745727020 scopus 로고    scopus 로고
    • Augmentation of osteoporotic bone: Effect of pulsed jet-lavage on injection forces, cement distribution and push-out strength of implants
    • Gisep A, Curtis R, Flütsch S, et al. 2006. Augmentation of osteoporotic bone: effect of pulsed jet-lavage on injection forces, cement distribution and push-out strength of implants. J Biomed Mater Res 78:83-88.
    • (2006) J Biomed Mater Res , vol.78 , pp. 83-88
    • Gisep, A.1    Curtis, R.2    Flütsch, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.