메뉴 건너뛰기




Volumn 22, Issue 2, 2007, Pages 176-182

Locked vs. unlocked plate osteosynthesis of the proximal humerus - A biomechanical study

Author keywords

Fracture; Humeral head; Internal fixator; Locked screws; Osteosynthesis

Indexed keywords

BIOMEDICAL EQUIPMENT; CADAVERIC EXPERIMENTS; DEFORMATION; FAILURE (MECHANICAL); LOADS (FORCES); SCREWS;

EID: 33845958580     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2006.08.009     Document Type: Article
Times cited : (119)

References (15)
  • 1
    • 0023905804 scopus 로고
    • Quantitative CT for determination of bone mineral density: a review
    • Cann C.E. Quantitative CT for determination of bone mineral density: a review. Radiology 166 (1988) 509-522
    • (1988) Radiology , vol.166 , pp. 509-522
    • Cann, C.E.1
  • 2
    • 33645061031 scopus 로고    scopus 로고
    • Evaluation and management of valgus impacted four-part proximal humerus fractures
    • DeFrano M.J., Brems J.J., Williams G.R., and Iannotti P. Evaluation and management of valgus impacted four-part proximal humerus fractures. Clin. Orthop. Rel. Res. 442 (2006) 109-114
    • (2006) Clin. Orthop. Rel. Res. , vol.442 , pp. 109-114
    • DeFrano, M.J.1    Brems, J.J.2    Williams, G.R.3    Iannotti, P.4
  • 3
    • 5644304280 scopus 로고    scopus 로고
    • Treatment of displaced 3- and 4-part fractures of the proximal humerus with fixator plate comprising angular stability
    • Hente R., Kampshoff J., Kinner B., Füchtmeier B., and Nerlich M. Treatment of displaced 3- and 4-part fractures of the proximal humerus with fixator plate comprising angular stability. Unfallchirurg 107 (2004) 769-782
    • (2004) Unfallchirurg , vol.107 , pp. 769-782
    • Hente, R.1    Kampshoff, J.2    Kinner, B.3    Füchtmeier, B.4    Nerlich, M.5
  • 5
    • 0035514246 scopus 로고    scopus 로고
    • Osteosynthesis techniques in proximal humeral fractures
    • Hessmann M.H., and Rommens P.M. Osteosynthesis techniques in proximal humeral fractures. Chirurg 72 (2001) 1235-1245
    • (2001) Chirurg , vol.72 , pp. 1235-1245
    • Hessmann, M.H.1    Rommens, P.M.2
  • 6
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens
    • Lill H., Hepp P., Korner J., Kassi J.-P., Verheyden A.P., Josten C., and Duda G.N. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch. Orthop. Trauma Surg. 123 (2003) 74-81
    • (2003) Arch. Orthop. Trauma Surg. , vol.123 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3    Kassi, J.-P.4    Verheyden, A.P.5    Josten, C.6    Duda, G.N.7
  • 7
    • 1542289158 scopus 로고    scopus 로고
    • The angle stable Locking-Proximal-Humerus-Plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results
    • Lill H., Hepp P., Rose T., König K., and Josten C. The angle stable Locking-Proximal-Humerus-Plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results. Zentralbl. Chir. 129 (2004) 43-49
    • (2004) Zentralbl. Chir. , vol.129 , pp. 43-49
    • Lill, H.1    Hepp, P.2    Rose, T.3    König, K.4    Josten, C.5
  • 8
    • 0037279050 scopus 로고    scopus 로고
    • Locking plate osteosynthesis for fractures of the proximal humerus
    • Lungershausen W., and Bach O. Locking plate osteosynthesis for fractures of the proximal humerus. Zentralbl. Chir. 128 (2003) 28-33
    • (2003) Zentralbl. Chir. , vol.128 , pp. 28-33
    • Lungershausen, W.1    Bach, O.2
  • 9
    • 2942607510 scopus 로고    scopus 로고
    • Results of intramedullary nailing of unstable proximal humeral fractures in geriatric patients with a new antegrade nail system
    • Mathews J., and Lobenhoffer P. Results of intramedullary nailing of unstable proximal humeral fractures in geriatric patients with a new antegrade nail system. Unfallchirurg 107 (2004) 372-380
    • (2004) Unfallchirurg , vol.107 , pp. 372-380
    • Mathews, J.1    Lobenhoffer, P.2
  • 10
    • 0014851643 scopus 로고
    • Displaced proximal humeral fractures
    • Neer C.S. Displaced proximal humeral fractures. J. Bone Joint Surg. Am. 52 (1970) 1077-1089
    • (1970) J. Bone Joint Surg. Am. , vol.52 , pp. 1077-1089
    • Neer, C.S.1
  • 11
    • 0011735919 scopus 로고    scopus 로고
    • Implant fixation in osteoprotic bone using monocortical screws
    • Seebeck J., Lill C., Morlock M.M., and Schneider E. Implant fixation in osteoprotic bone using monocortical screws. Trauma Berufskh. 1 (1999) 411-414
    • (1999) Trauma Berufskh. , vol.1 , pp. 411-414
    • Seebeck, J.1    Lill, C.2    Morlock, M.M.3    Schneider, E.4
  • 12
    • 12244250402 scopus 로고    scopus 로고
    • Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses
    • Seide K., Morlock M.M., Schümann U., and Wolter D. Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses. Trauma Berufskh. 1 (1999) 320-325
    • (1999) Trauma Berufskh. , vol.1 , pp. 320-325
    • Seide, K.1    Morlock, M.M.2    Schümann, U.3    Wolter, D.4
  • 13
    • 0036844148 scopus 로고    scopus 로고
    • Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus
    • Wijgman A.J., Roolker W., Patt T.W., Raaymakers E.L., and Marti R.K. Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus. J. Bone Joint Surg. Am. 84 (2002) 1919-1925
    • (2002) J. Bone Joint Surg. Am. , vol.84 , pp. 1919-1925
    • Wijgman, A.J.1    Roolker, W.2    Patt, T.W.3    Raaymakers, E.L.4    Marti, R.K.5
  • 14
    • 0346448904 scopus 로고    scopus 로고
    • The universal titanium internal fixator. Development, mechanics, implant design, and surgical application
    • Wolter D., Schümann U., and Seide K. The universal titanium internal fixator. Development, mechanics, implant design, and surgical application. Trauma Berufskh. 1 (1999) 307-319
    • (1999) Trauma Berufskh. , vol.1 , pp. 307-319
    • Wolter, D.1    Schümann, U.2    Seide, K.3
  • 15
    • 0012617406 scopus 로고    scopus 로고
    • First clinical experiences with internal fixator of the humerus
    • Wurm M., Wolter D., Wenzl M., and Jessel M. First clinical experiences with internal fixator of the humerus. Trauma Berufskh. 1 (1999) 370-374
    • (1999) Trauma Berufskh. , vol.1 , pp. 370-374
    • Wurm, M.1    Wolter, D.2    Wenzl, M.3    Jessel, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.