메뉴 건너뛰기




Volumn 11, Issue 4, 2010, Pages 613-618

Fabrication and characterization of two-chamber and three-chamber peristaltic micropumps

Author keywords

Diffuser; Nozzle; Peristaltic micropump; Piezoelectric buzzer; Working phase

Indexed keywords


EID: 78049269561     PISSN: 12298557     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12541-010-0071-7     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0001555349 scopus 로고    scopus 로고
    • Resonantly Driven Piezoelectric Micropump Fabrication of a Micropump Having High Power Density
    • Park, J. H., Yoshida, K. and Yokota, S., "Resonantly Driven Piezoelectric Micropump Fabrication of a Micropump Having High Power Density," Mechatronics, Vol. 9, No. 7, pp. 687-702, 1999.
    • (1999) Mechatronics , vol.9 , Issue.7 , pp. 687-702
    • Park, J.H.1    Yoshida, K.2    Yokota, S.3
  • 2
    • 0032594980 scopus 로고    scopus 로고
    • Analytical Modeling of Electrostatic Membrane Actuator for Micro Pumps
    • Saif, M. T. B., Alaca, E. and Sehitoglu, H., "Analytical Modeling of Electrostatic Membrane Actuator for Micro Pumps," J. Microelectromech. Syst., Vol. 8, No. 3, pp. 335-345, 1999.
    • (1999) J. Microelectromech. Syst , vol.8 , Issue.3 , pp. 335-345
    • Saif, M.T.B.1    Alaca, E.2    Sehitoglu, H.3
  • 4
    • 0033882554 scopus 로고    scopus 로고
    • Theoretical and Experimental Study of MHD (Magnetohydrodynamic) Micropump
    • Jang, J. and Lee, S. S., "Theoretical and Experimental Study of MHD (Magnetohydrodynamic) Micropump," Sens. Actuators, A: Physical, Vol. 80, No. 1, pp. 84-89, 2000.
    • (2000) Sens. Actuators, A: Physical , vol.80 , Issue.1 , pp. 84-89
    • Jang, J.1    Lee, S.S.2
  • 5
    • 77950652376 scopus 로고    scopus 로고
    • Innovative Composite PDMS Micropumps with Electromagnetic Drive
    • Shen, C. Y. and Liu, H. K., "Innovative Composite PDMS Micropumps with Electromagnetic Drive," Sens. Mater., Vol. 22, No. 2, pp. 85-100, 2010.
    • (2010) Sens. Mater , vol.22 , Issue.2 , pp. 85-100
    • Shen, C.Y.1    Liu, H.K.2
  • 6
    • 0035948960 scopus 로고    scopus 로고
    • Characteristics and Fabrication of NiTi/Si Diaphragm Micropump
    • Xu, D. and Wang, L., "Characteristics and Fabrication of NiTi/Si Diaphragm Micropump," Sens. Actuators, A: Physical, Vol. 93, No. 1, pp. 87-92, 2001.
    • (2001) Sens. Actuators, A: Physical , vol.93 , Issue.1 , pp. 87-92
    • Xu, D.1    Wang, L.2
  • 8
    • 34548598601 scopus 로고    scopus 로고
    • Peristaltic Piezoelectric Micropump System for Biomedical Applications
    • Jang, L. S. and Kan, W. H., "Peristaltic Piezoelectric Micropump System for Biomedical Applications," Biomed. Microdevices, Vol. 9, No. 4, pp. 619-626, 2007.
    • (2007) Biomed. Microdevices , vol.9 , Issue.4 , pp. 619-626
    • Jang, L.S.1    Kan, W.H.2
  • 9
    • 55349099458 scopus 로고    scopus 로고
    • An Experimental and Numerical Investigation into the Effects of Diffuser Valves in Polymethylmethacrylate (PMMA) Peristaltic Micropump
    • Hsu, Y. C., Li, J. H. and Le, N. B., "An Experimental and Numerical Investigation into the Effects of Diffuser Valves in Polymethylmethacrylate (PMMA) Peristaltic Micropump," Sens. Actuators, A: Physical, Vol. 148, No. 1, pp. 149-157, 2008.
    • (2008) Sens. Actuators, A: Physical , vol.148 , Issue.1 , pp. 149-157
    • Hsu, Y.C.1    Li, J.H.2    Le, N.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.