Volumn 10, Issue 7, 2010, Pages 7044-7056

Investigation of the frequency shift of a SAD circuit loop and the internal micro-cantilever in a gas sensor

Author keywords

Frequency shift; Gas sensor; Micro cantilever; Oscillator loop

Indexed keywords

ELECTRIC SIGNAL; FREQUENCY SHIFT; MECHANICAL RESONANCE FREQUENCY; MICRO-CANTILEVERS; OSCILLATOR CIRCUITS; RESONANCE FREQUENCIES; RESONATING FREQUENCY; WORKING FREQUENCY;

EID: 77957139173     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s100707044     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 67649841043 scopus 로고    scopus 로고
    • Micro-electromechanical sensors in the analytical field
    • Zougagh, M.; Rios, A.; Micro-electromechanical sensors in the analytical field. Analyst 2009, 134, 1274-1290.
    • (2009) Analyst , vol.134 , pp. 1274-1290
    • Zougagh, M.1    Rios, A.2
  • 2
    • 0036646553 scopus 로고    scopus 로고
    • Complementary metal oxide Semiconductor cantilever arrays on a single chip: Mass-sensitive detection of volatile organic compounds
    • Lange, D.; Hagleitner, C. Complementary metal oxide Semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds. Anal. Chem 2002, 74, 3084-3095.
    • (2002) Anal. Chem , vol.74 , pp. 3084-3095
    • Lange, D.1    Hagleitner, C.2
  • 4
    • 84876623172 scopus 로고    scopus 로고
    • Resonating frequency of a SAD circuit loop and inner micro-cantilever in a gas sensor
    • In press
    • Li, P; Zhao, J. Resonating frequency of a SAD circuit loop and inner micro-cantilever in a gas sensor. IEEE Sens. J. (In press).
    • IEEE Sens. J
    • Li, P.1    Zhao, J.2
  • 6
    • 44649143920 scopus 로고    scopus 로고
    • Measurement of mechanical properties of cantilever shaped materials
    • Finot, E.; Passian, A.; Thundat, T. Measurement of mechanical properties of cantilever shaped materials. Sensors 2008, 8, 3497-3541.
    • (2008) Sensors , vol.8 , pp. 3497-3541
    • Finot, E.1    Passian, A.2    Thundat, T.3
  • 7
    • 4544387347 scopus 로고    scopus 로고
    • Chemical sensing: Millimeter size resonant microcantilever performance
    • Fadel, L.; Lochon, F. Chemical sensing: millimeter size resonant microcantilever performance. J. Micromech. Microeng. 2004, 14, S23-S30.
    • (2004) J. Micromech. Microeng , vol.14
    • Fadel, L.1    Lochon, F.2
  • 8
    • 27544480292 scopus 로고    scopus 로고
    • CMOS MEMS oscillator for gas chemical detection
    • Bedair, S.; Fedder, G. CMOS MEMS oscillator for gas chemical detection. Proc. IEEE 2004, 2, 955-958.
    • (2004) Proc. IEEE , vol.2 , pp. 955-958
    • Bedair, S.1    Fedder, G.2
  • 9
    • 18144363562 scopus 로고    scopus 로고
    • Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems
    • Vancura, C.; Ruegg, M. Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems. Anal. Chem. 2005, 77, 2690-2699.
    • (2005) Anal. Chem , vol.77 , pp. 2690-2699
    • Vancura, C.1    Ruegg, M.2
  • 10
    • 34548652435 scopus 로고    scopus 로고
    • Monolithic CMOS multi-tranducer gas sensor microsystem for organic and inorganic analytes
    • Li, Y.; Vancura, C. Monolithic CMOS multi-tranducer gas sensor microsystem for organic and inorganic analytes. Sens. Actuat. 2007, B126, 431-440.
    • (2007) Sens. Actuat , vol.126 , pp. 431-440
    • Li, Y.1    Vancura, C.2
  • 11
    • 67349115661 scopus 로고    scopus 로고
    • Characterization and improvement on quality factor of microcantilevers with self-actuation and self-sensing capability
    • Lu, J.; Ikehara, T. Characterization and improvement on quality factor of microcantilevers with self-actuation and self-sensing capability. Microelectron. Eng. 2009, 86, 1208-1211.
    • (2009) Microelectron. Eng , vol.86 , pp. 1208-1211
    • Lu, J.1    Ikehara, T.2
  • 12
    • 58149267998 scopus 로고    scopus 로고
    • Mechanical and electronic approaches to improve the sensitivity of microcantilever sensors
    • Mutyala, M.S.K.; Bandhanadham, D. Mechanical and electronic approaches to improve the sensitivity of microcantilever sensors. Acta Mech. Sin. 2009, 25, 1-12.
    • (2009) Acta Mech. Sin , vol.25 , pp. 1-12
    • Mutyala, M.S.K.1    Bandhanadham, D.2
  • 13
    • 67849085084 scopus 로고    scopus 로고
    • Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancement
    • Yu, H.; Li, X. Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancement. J. Micromech. Microeng. 2009, 19, 045023.
    • (2009) J. Micromech. Microeng , vol.19 , pp. 045023
    • Yu, H.1    Li, X.2
  • 15
    • 77949546010 scopus 로고    scopus 로고
    • Tsinghua University Publishing House, Beijing, China
    • Feng, G. Resonant sensing theory and devices; Tsinghua University Publishing House: Beijing, China, 2008; pp. 25-26.
    • (2008) Resonant Sensing Theory and Devices , pp. 25-26
    • Feng, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.