메뉴 건너뛰기




Volumn 106, Issue 6, 2010, Pages 810-818

50th anniversary of the first successful permanent pacemaker implantation in the United States: Historical review and future directions

Author keywords

[No Author keywords available]

Indexed keywords

LEAD;

EID: 77956326865     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2010.04.043     Document Type: Review
Times cited : (82)

References (70)
  • 2
    • 0029276118 scopus 로고
    • Profile "wilson Greatbatch."
    • J.A. Adam Profile "Wilson Greatbatch." IEEE 32 1995 56 61
    • (1995) IEEE , vol.32 , pp. 56-61
    • Adam, J.A.1
  • 3
    • 0001050251 scopus 로고
    • A transistorized, self-contained, implantable pacemaker for the long-term correction of complete heart block
    • W.M. Chardack, A.A. Gage, and W. Greatbatch A transistorized, self-contained, implantable pacemaker for the long-term correction of complete heart block Surgery 48 1960 643 654
    • (1960) Surgery , vol.48 , pp. 643-654
    • Chardack, W.M.1    Gage, A.A.2    Greatbatch, W.3
  • 4
    • 0001593584 scopus 로고
    • Resuscitation of the stopped heart by intracardiac therapy
    • A.S. Hyman Resuscitation of the stopped heart by intracardiac therapy Arch Intern Med 46 1930 553 568
    • (1930) Arch Intern Med , vol.46 , pp. 553-568
    • Hyman, A.S.1
  • 5
    • 0142105823 scopus 로고    scopus 로고
    • The early history of cardiac pacing
    • S. Furman The early history of cardiac pacing Pacing Clin Electrophysiol 26 2003 2023 2032
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 2023-2032
    • Furman, S.1
  • 6
    • 0001422435 scopus 로고
    • Resuscitation of the heart in ventricular standstill by external electric stimulation
    • P.M. Zoll Resuscitation of the heart in ventricular standstill by external electric stimulation N Engl J Med 247 1952 768 771
    • (1952) N Engl J Med , vol.247 , pp. 768-771
    • Zoll, P.M.1
  • 7
    • 33845505503 scopus 로고    scopus 로고
    • Critical role of physiologist John A: Johnson in the origins of Minnesota's billion dollar pacemaker industry
    • V.L. Gott Critical role of physiologist John A Johnson in the origins of Minnesota's billion dollar pacemaker industry Ann Thorac Surg 83 2007 349 353
    • (2007) Ann Thorac Surg , vol.83 , pp. 349-353
    • Gott, V.L.1
  • 8
    • 0001493597 scopus 로고
    • Transistor pacemaker for treatment of complete atrioventricular dissociation
    • C.W. Lillehei, V.L. Gott, P.C. Hodges, D.M. Long, and E.E. Bakken Transistor pacemaker for treatment of complete atrioventricular dissociation JAMA 172 1960 76 80
    • (1960) JAMA , vol.172 , pp. 76-80
    • Lillehei, C.W.1    Gott, V.L.2    Hodges, P.C.3    Long, D.M.4    Bakken, E.E.5
  • 11
    • 33645214244 scopus 로고    scopus 로고
    • Thirty-one years of clinical experience with "nuclear-powered" pacemakers
    • V. Parsonnet, J. Driller, D. Cook, and S.A. Rizvi Thirty-one years of clinical experience with "nuclear-powered" pacemakers Pacing Clin Electrophysiol 29 2006 195 200
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 195-200
    • Parsonnet, V.1    Driller, J.2    Cook, D.3    Rizvi, S.A.4
  • 14
    • 2942519198 scopus 로고    scopus 로고
    • Implantable transvenous pacing leads: The shape of things to come
    • H.G. Mond, and D. Grenz Implantable transvenous pacing leads: the shape of things to come Pacing Clin Electrophysiol 27 2004 887 893
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 887-893
    • Mond, H.G.1    Grenz, D.2
  • 15
    • 0344650511 scopus 로고
    • The porous titanium steroid eluting electrode: A double blind study assessing the stimulation threshold effects of steroid
    • H. Mond, K. Stokes, J. Helland, L. Grigg, P. Kertes, B. Pate, and D. Hunt The porous titanium steroid eluting electrode: a double blind study assessing the stimulation threshold effects of steroid Pacing Clin Electrophysiol 11 1988 214 219
    • (1988) Pacing Clin Electrophysiol , vol.11 , pp. 214-219
    • Mond, H.1    Stokes, K.2    Helland, J.3    Grigg, L.4    Kertes, P.5    Pate, B.6    Hunt, D.7
  • 17
    • 0033952290 scopus 로고    scopus 로고
    • Cardiac pacing leads
    • G.H. Crossley Cardiac pacing leads Cardiol Clin 18 2000 95 112
    • (2000) Cardiol Clin , vol.18 , pp. 95-112
    • Crossley, G.H.1
  • 18
    • 2242427973 scopus 로고    scopus 로고
    • Recent advances in pacemaker lead technology
    • H.G. Mond Recent advances in pacemaker lead technology Card Electrophysiol Rev 3 1999 5 9
    • (1999) Card Electrophysiol Rev , vol.3 , pp. 5-9
    • Mond, H.G.1
  • 20
    • 77956329491 scopus 로고    scopus 로고
    • Boston Scientific
    • Boston Scientific CRM product performance report 2009: Q4 summary edition http://www.bostonscientific.com/templatedata/imports/HTML/PPR/ppr/references/ report-download-2009-q4.shtml Accessed April 20, 2010
    • CRM Product Performance Report 2009: Q4 Summary Edition
  • 24
    • 0013814319 scopus 로고
    • Five years' clinical experience with an implantable pacemaker: An appraisal
    • W.M. Chardack, A.A. Gage, A.J. Federico, G. Schimert, and W. Greatbatch Five years' clinical experience with an implantable pacemaker: an appraisal Surgery 58 1965 915 922
    • (1965) Surgery , vol.58 , pp. 915-922
    • Chardack, W.M.1    Gage, A.A.2    Federico, A.J.3    Schimert, G.4    Greatbatch, W.5
  • 27
    • 0024320921 scopus 로고
    • Clinical experience with a new activity sensing rate modulated pacemaker using autoprogrammability
    • V. Mahaux, A. Waleffe, and H.E. Kulbertus Clinical experience with a new activity sensing rate modulated pacemaker using autoprogrammability Pacing Clin Electrophysiol 12 1989 1362 1368
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 1362-1368
    • Mahaux, V.1    Waleffe, A.2    Kulbertus, H.E.3
  • 28
    • 0006085902 scopus 로고
    • Contribution of atrial systole to the cardiac function at a fixed and at a variable ventricular rate
    • A. Benchimol, A. Duenas, M.S. Liggett, and E.G. Dimond Contribution of atrial systole to the cardiac function at a fixed and at a variable ventricular rate Am J Cardiol 16 1965 11 21
    • (1965) Am J Cardiol , vol.16 , pp. 11-21
    • Benchimol, A.1    Duenas, A.2    Liggett, M.S.3    Dimond, E.G.4
  • 29
    • 0016592834 scopus 로고
    • Haemodynamic effect of atrial triggered versus fixed rate pacing at rest and during exercise in complete heart block
    • I. Karlof Haemodynamic effect of atrial triggered versus fixed rate pacing at rest and during exercise in complete heart block Acta Med Scand 197 1975 195 206
    • (1975) Acta Med Scand , vol.197 , pp. 195-206
    • Karlof, I.1
  • 30
    • 0002204832 scopus 로고
    • Atrial contribution to cardiac output in complete heart block
    • P. Samet, W.H. Bernstein, D.A. Nathan, and A. Lopez Atrial contribution to cardiac output in complete heart block Am J Cardiol 16 1965 1 10
    • (1965) Am J Cardiol , vol.16 , pp. 1-10
    • Samet, P.1    Bernstein, W.H.2    Nathan, D.A.3    Lopez, A.4
  • 31
    • 77956332925 scopus 로고    scopus 로고
    • Sensors for implantable devices : ideal characteristics, sensor combinations, and automaticity
    • H.F. Tse, and C.P. Lau Sensors for implantable devices : ideal characteristics, sensor combinations, and automaticity K.A. Ellenbogen, G.N. Kay, C.P. Lau, B.L. Wilkoff, Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy 3rd ed. 2006 W.B. Saunders Philadelphia, Pennsylvania
    • (2006) Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy
    • Tse, H.F.1    Lau, C.P.2
  • 32
    • 0023256495 scopus 로고
    • Control of pacemaker rate by impedance-based respiratory minute ventilation
    • E. Alt, M. Heinz, C. Hirgstetter, H.P. Emslander, S. Daum, and H. Blomer Control of pacemaker rate by impedance-based respiratory minute ventilation Chest 92 1987 247 252
    • (1987) Chest , vol.92 , pp. 247-252
    • Alt, E.1    Heinz, M.2    Hirgstetter, C.3    Emslander, H.P.4    Daum, S.5    Blomer, H.6
  • 33
    • 0020530956 scopus 로고
    • The use of QT interval to determine pacing rate: Early clinical experience
    • A.F. Rickards, R.M. Donaldson, and H.J. Thalen The use of QT interval to determine pacing rate: early clinical experience Pacing Clin Electrophysiol 6 1983 346 356
    • (1983) Pacing Clin Electrophysiol , vol.6 , pp. 346-356
    • Rickards, A.F.1    Donaldson, R.M.2    Thalen, H.J.3
  • 34
    • 0021913515 scopus 로고
    • Activity-sensing, rate-responsive pacing: Improvement in myocardial performance with exercise
    • D.P. Humen, W.J. Kostuk, and G.J. Klein Activity-sensing, rate-responsive pacing: improvement in myocardial performance with exercise Pacing Clin Electrophysiol 8 1985 52 59
    • (1985) Pacing Clin Electrophysiol , vol.8 , pp. 52-59
    • Humen, D.P.1    Kostuk, W.J.2    Klein, G.J.3
  • 36
    • 16644394121 scopus 로고    scopus 로고
    • Closed loop stimulation in prevention of vasovagal syncope: Inotropy Controlled Pacing in Vasovagal Syncope (INVASY): A multicentre randomized, single blind, controlled study
    • INVASY Study Investigators C
    • E. Occhetta, M. Bortnik, R. Audoglio, C. Vassanelli INVASY Study Investigators Closed loop stimulation in prevention of vasovagal syncope Inotropy Controlled Pacing in Vasovagal Syncope (INVASY): a multicentre randomized, single blind, controlled study Europace 6 2004 538 547
    • (2004) Europace , vol.6 , pp. 538-547
    • Occhetta, E.1    Bortnik, M.2    Audoglio, R.3    Vassanelli, C.4
  • 38
    • 53749102979 scopus 로고    scopus 로고
    • A blended sensor restores chronotropic response more favorably than an accelerometer alone in pacemaker patients: The LIFE study results
    • LIFE Study Results T.E
    • J. Coman, R. Freedman, B.A. Koplan, R. Reeves, P. Santucci, K.Q. Stolen, S.M. Kraus, T.E. Meyer LIFE Study Results A blended sensor restores chronotropic response more favorably than an accelerometer alone in pacemaker patients: the LIFE study results Pacing Clin Electrophysiol 31 2008 1433 1442
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1433-1442
    • Coman, J.1    Freedman, R.2    Koplan, B.A.3    Reeves, R.4    Santucci, P.5    Stolen, K.Q.6    Kraus, S.M.7    Meyer, T.E.8
  • 40
    • 0037134839 scopus 로고    scopus 로고
    • Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay
    • Pacing Therapies in Congestive Heart Failure (PATH-CHF) Study Group H
    • A. Auricchio, C. Stellbrink, S. Sack, M. Block, J. Vogt, P. Bakker, C. Huth, F. Schndube, U. Wolfhard, D. Bcker, O. Krahnefeld, H. Kirkels Pacing Therapies in Congestive Heart Failure (PATH-CHF) Study Group Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay J Am Coll Cardiol 39 2002 2026 2033
    • (2002) J Am Coll Cardiol , vol.39 , pp. 2026-2033
    • Auricchio, A.1    Stellbrink, C.2    Sack, S.3    Block, M.4    Vogt, J.5    Bakker, P.6    Huth, C.7    Schndube, F.8    Wolfhard, U.9    Bcker, D.10    Krahnefeld, O.11    Kirkels, O.12
  • 42
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators A.M
    • M.R. Bristow, L.A. Saxon, J. Boehmer, S. Krueger, D.A. Kass, T. De Marco, P. Carson, L. DiCarlo, D. DeMets, B.G. White, D.W. DeVries, A.M. Feldman Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure N Engl J Med 350 2004 2140 2150
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3    Krueger, S.4    Kass, D.A.5    De Marco, T.6    Carson, P.7    Dicarlo, L.8    Demets, D.9    White, B.G.10    Devries, D.W.11    Feldman, A.M.12
  • 43
    • 16844364826 scopus 로고    scopus 로고
    • The effect of cardiac resynchronization on morbidity and mortality in heart failure
    • Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators L
    • J.G. Cleland, J.C. Daubert, E. Erdmann, N. Freemantle, D. Gras, L. Kappenberger, L. Tavazzi Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators The effect of cardiac resynchronization on morbidity and mortality in heart failure N Engl J Med 352 2005 1539 1549
    • (2005) N Engl J Med , vol.352 , pp. 1539-1549
    • Cleland, J.G.1    Daubert, J.C.2    Erdmann, E.3    Freemantle, N.4    Gras, D.5    Kappenberger, L.6    Tavazzi, L.7
  • 44
    • 33846485719 scopus 로고    scopus 로고
    • Cardiac resynchronization therapy or atrio-biventricular pacing-what should it be called?
    • J.G. Cleland, M. Nasir, and A. Tageldien Cardiac resynchronization therapy or atrio-biventricular pacing-what should it be called? Nat Clin Pract Cardiovasc Med 4 2007 90 101
    • (2007) Nat Clin Pract Cardiovasc Med , vol.4 , pp. 90-101
    • Cleland, J.G.1    Nasir, M.2    Tageldien, A.3
  • 47
    • 33646252323 scopus 로고    scopus 로고
    • Biventricular versus conventional right ventricular stimulation for patients with standard pacing indication and left ventricular dysfunction: The Homburg Biventricular Pacing Evaluation (HOBIPACE)
    • M. Kindermann, B. Hennen, J. Jung, J. Geisel, M. Bohm, and G. Frohlig Biventricular versus conventional right ventricular stimulation for patients with standard pacing indication and left ventricular dysfunction: the Homburg Biventricular Pacing Evaluation (HOBIPACE) J Am Coll Cardiol 47 2006 1927 1937
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1927-1937
    • Kindermann, M.1    Hennen, B.2    Jung, J.3    Geisel, J.4    Bohm, M.5    Frohlig, G.6
  • 50
    • 0042919375 scopus 로고    scopus 로고
    • Electrochemical power sources and the treatment of human illness
    • C.F. Holmes Electrochemical power sources and the treatment of human illness Electrochem Soc Interf 2003 26 Fall
    • (2003) Electrochem Soc Interf , pp. 26
    • Holmes, C.F.1
  • 52
    • 77956319291 scopus 로고    scopus 로고
    • Greatbatch Medical
    • ® battery technology http://www.greatbatchmedical.com/assets/products/QMR%20Battery.pdf Accessed April 20, 2010
    • ® Battery Technology
  • 53
    • 77956303598 scopus 로고    scopus 로고
    • Biophan Technologies
    • Biophan Technologies Biothermal power source http://www.biophan.com/ index.php?option=com-content&task=view&id=25&Itemid=119 Accessed April 20, 2010
    • Biothermal Power Source
  • 54
    • 0036741233 scopus 로고    scopus 로고
    • Interference in implanted cardiac devices, part i
    • S.L. Pinski, and R.G. Trohman Interference in implanted cardiac devices, part I Pacing Clin Electrophysiol 25 2003 1367 1381
    • (2003) Pacing Clin Electrophysiol , vol.25 , pp. 1367-1381
    • Pinski, S.L.1    Trohman, R.G.2
  • 55
    • 0036800992 scopus 로고    scopus 로고
    • Interference in implanted cardiac devices, part II
    • S.L. Pinski, and R.G. Trohman Interference in implanted cardiac devices, part II Pacing Clin Electrophysiol 25 2003 1496 1509
    • (2003) Pacing Clin Electrophysiol , vol.25 , pp. 1496-1509
    • Pinski, S.L.1    Trohman, R.G.2
  • 56
    • 18044393463 scopus 로고    scopus 로고
    • Current clinical issues for MRI scanning of pacemaker and defibrillator patients
    • R. Kalin, and M.S. Stanton Current clinical issues for MRI scanning of pacemaker and defibrillator patients Pacing Clin Electrophysiol 28 2005 326 328
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 326-328
    • Kalin, R.1    Stanton, M.S.2
  • 57
    • 0038221323 scopus 로고    scopus 로고
    • Cardiac pacemakers, ICDs, and loop recorder: Evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-tesla MR systems
    • F.G. Shellock, J.A. Tkach, P.M. Ruggieri, and T.J. Masaryk Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-tesla MR systems J Cardiovasc Magn Reson 5 2003 387 397
    • (2003) J Cardiovasc Magn Reson , vol.5 , pp. 387-397
    • Shellock, F.G.1    Tkach, J.A.2    Ruggieri, P.M.3    Masaryk, T.J.4
  • 58
    • 0023253185 scopus 로고
    • Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers
    • D.L. Hayes, D.R. Holmes Jr, and J.E. Gray Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers J Am Coll Cardiol 10 1987 782 786
    • (1987) J Am Coll Cardiol , vol.10 , pp. 782-786
    • Hayes, D.L.1    Holmes Jr., D.R.2    Gray, J.E.3
  • 60
    • 0036288276 scopus 로고    scopus 로고
    • Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead
    • W. Greatbatch, V. Miller, and F.G. Shellock Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead J Magn Reson Imaging 16 2002 97 103
    • (2002) J Magn Reson Imaging , vol.16 , pp. 97-103
    • Greatbatch, W.1    Miller, V.2    Shellock, F.G.3
  • 61
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla
    • S. Nazarian, A. Roguin, M.M. Zviman, A.C. Lardo, T.L. Dickfeld, H. Calkins, R.G. Weiss, R.D. Berger, D.A. Bluemke, and H.R. Halperin Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla Circulation 114 2006 1277 1284
    • (2006) Circulation , vol.114 , pp. 1277-1284
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3    Lardo, A.C.4    Dickfeld, T.L.5    Calkins, H.6    Weiss, R.G.7    Berger, R.D.8    Bluemke, D.A.9    Halperin, H.R.10
  • 62
    • 70349442539 scopus 로고    scopus 로고
    • Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a "modern" pacemaker
    • J.R. Gimbel Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a "modern" pacemaker Europace 11 2009 1241 1242
    • (2009) Europace , vol.11 , pp. 1241-1242
    • Gimbel, J.R.1
  • 63
    • 59149092325 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: Clinical study design
    • R. Sutton, E. Kanal, B.L. Wilkoff, D. Bello, R. Luechinger, I. Jenniskens, M. Hull, and T. Sommer Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design Trials 9 2008 68
    • (2008) Trials , vol.9 , pp. 68
    • Sutton, R.1    Kanal, E.2    Wilkoff, B.L.3    Bello, D.4    Luechinger, R.5    Jenniskens, I.6    Hull, M.7    Sommer, T.8
  • 64
    • 67651079050 scopus 로고    scopus 로고
    • Safety and efficacy of new pacemaker system that can be used in MRI environment: First clinical trial results [abstract]
    • T. Sommer, E. Kanal, and M. Taborsky Safety and efficacy of new pacemaker system that can be used in MRI environment: first clinical trial results [abstract] Eur Heart J 29 suppl 2008 21 22
    • (2008) Eur Heart J , vol.29 , Issue.SUPPL. , pp. 21-22
    • Sommer, T.1    Kanal, E.2    Taborsky, M.3
  • 65
    • 34547931047 scopus 로고    scopus 로고
    • First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: Implications for wireless pacing with implantable devices
    • K.L. Lee, C.P. Lau, H.F. Tse, D.S. Echt, D. Heaven, W. Smith, and M. Hood First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices J Am Coll Cardiol 50 2007 877 883
    • (2007) J Am Coll Cardiol , vol.50 , pp. 877-883
    • Lee, K.L.1    Lau, C.P.2    Tse, H.F.3    Echt, D.S.4    Heaven, D.5    Smith, W.6    Hood, M.7
  • 66
    • 65649133577 scopus 로고    scopus 로고
    • Temporary leadless pacing in heart failure patients with ultrasound-mediated stimulation energy and effects on the acoustic window
    • K.L. Lee, H.F. Tse, D.S. Echt, and C.P. Lau Temporary leadless pacing in heart failure patients with ultrasound-mediated stimulation energy and effects on the acoustic window Heart Rhythm 6 2009 742 748
    • (2009) Heart Rhythm , vol.6 , pp. 742-748
    • Lee, K.L.1    Tse, H.F.2    Echt, D.S.3    Lau, C.P.4
  • 67
    • 40349092932 scopus 로고    scopus 로고
    • Biological pacemakers as a therapy for cardiac arrhythmias
    • E. Marban, and H.C. Cho Biological pacemakers as a therapy for cardiac arrhythmias Curr Opin Cardiol 23 2008 46 54
    • (2008) Curr Opin Cardiol , vol.23 , pp. 46-54
    • Marban, E.1    Cho, H.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.