메뉴 건너뛰기




Volumn 361, Issue 14, 2009, Pages 1329-1338

Cardiac-resynchronization therapy for the prevention of heart-failure events

(157)  Moss, Arthur J a   Hall, W Jackson a   Cannom, David S b   Klein, Helmut a   Brown, Mary W a   Daubert, James P c   Estes III, N A Mark d   Foster, Elyse e   Greenberg, Henry f   Higgins, Steven L g   Pfeffer, Marc A h   Solomon, Scott D h   Wilber, David i   Zareba, Wojciech a   Desai, P j   Wiggins, S j   Greer, G j   Beau, S j   Curnis, A j   Katz, A j   more..


Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOMYOPATHY; CARDIOVASCULAR RISK; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEFIBRILLATOR; FEMALE; FOLLOW UP; HEART DEATH; HEART EJECTION FRACTION; HEART FAILURE; HEART LEFT VENTRICLE VOLUME; HEART VENTRICLE REMODELING; HUMAN; ISCHEMIC HEART DISEASE; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; MORTALITY; PERICARDIAL EFFUSION; PNEUMOTHORAX; PRIORITY JOURNAL; QRS COMPLEX; RANDOMIZED CONTROLLED TRIAL; SURGICAL INFECTION; ARTIFICIAL HEART PACEMAKER; CARDIOVERSION; DISEASE FREE SURVIVAL; HEART PACING; HEART STROKE VOLUME; KAPLAN MEIER METHOD; MIDDLE AGED; MULTICENTER STUDY;

EID: 70349625757     PISSN: 00284793     EISSN: 15334406     Source Type: Journal    
DOI: 10.1056/NEJMoa0906431     Document Type: Article
Times cited : (2585)

References (18)
  • 1
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • [Erratum, N Engl J Med 2005;352:2146.]
    • Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005;352:225-237 [Erratum, N Engl J Med 2005;352:2146.]
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 2
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia
    • Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med 1996;335:1933-1940
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3
  • 4
    • 33745932275 scopus 로고    scopus 로고
    • Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the multicenter automatic defibrillator implantation trial II
    • DOI 10.1161/CIRCULATIONAHA.105.577262, PII 0000301720060620000008
    • Goldenberg I, Moss AJ, Hall WJ, et al. Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the Multicenter Automatic Defibrillator Implantation Trial II. Circulation 2006;113:2810-2817 (Pubitemid 44305293)
    • (2006) Circulation , vol.113 , Issue.24 , pp. 2810-2817
    • Goldenberg, I.1    Moss, A.J.2    Hall, W.J.3    McNitt, S.4    Zareba, W.5    Andrews, M.L.6    Cannom, D.S.7
  • 7
    • 44649192645 scopus 로고    scopus 로고
    • ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices)
    • [Erratum, Circulation 2009;120(5):e34-e35.]
    • Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation 2008; 117(21):e350-e408. [Erratum, Circulation 2009;120(5):e34-e35.]
    • (2008) Circulation , vol.117 , Issue.21
    • Epstein, A.E.1    Dimarco, J.P.2    Ellenbogen, K.A.3
  • 8
    • 56349114416 scopus 로고    scopus 로고
    • Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms
    • Linde C, Abraham WT, Gold MR, St John Sutton M, Ghio S, Daubert C. Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms. J Am Coll Cardiol 2008;52:1834-1843
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1834-1843
    • Linde, C.1    Abraham, W.T.2    Gold, M.R.3    St John Sutton, M.4    Ghio, S.5    Daubert, C.6
  • 9
    • 33644806466 scopus 로고    scopus 로고
    • Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT): Design and clinical protocol
    • Moss AJ, Brown MW, Cannom DS, et al. Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT): design and clinical protocol. Ann Noninvasive Electrocardiol 2005;10:Suppl:34-43.
    • (2005) Ann Noninvasive Electrocardiol , vol.10 , Issue.SUPPL. , pp. 34-43
    • Moss, A.J.1    Brown, M.W.2    Cannom, D.S.3
  • 12
    • 0023217456 scopus 로고
    • Approximately optimal one-parameter boundaries for group sequential trials
    • Wang SK, Tsiatis AA. Approximately optimal one-parameter boundaries for group sequential trials. Biometrics 1987;43:193-199
    • (1987) Biometrics , vol.43 , pp. 193-199
    • Wang, S.K.1    Tsiatis, A.A.2
  • 13
    • 0000336139 scopus 로고
    • Regression models and life-tables
    • Cox DR. Regression models and life-tables. J R Stat Soc [B] 1972;34:187-220.
    • (1972) J R Stat Soc [B] , vol.34 , pp. 187-220
    • Cox, D.R.1
  • 15
    • 12444314986 scopus 로고    scopus 로고
    • Sequential tests and estimators after overrunning based on maximum-likelihood ordering
    • DOI 10.1093/biomet/89.3.699
    • Hall WJ, Liu A. Sequential tests and estimates after overrunning based on maximum-likelihood ordering. Biometrika 2002;89:699-707. (Pubitemid 41311975)
    • (2002) Biometrika , vol.89 , Issue.3 , pp. 699-707
    • Hall, W.J.1    Liu, A.2
  • 16
    • 33751313903 scopus 로고    scopus 로고
    • Variable impact of combining fatal and nonfatal end points in heart failure trials
    • DOI 10.1161/CIRCULATIONAHA.106.620039, PII 0000301720061121000016
    • Skali H, Pfeffer MA, Lubsen J, Solomon SD. Variable impact of combining fatal and nonfatal end points in heart failure trials. Circulation 2006;114:2298-2303 (Pubitemid 44801489)
    • (2006) Circulation , vol.114 , Issue.21 , pp. 2298-2303
    • Skali, H.1    Pfeffer, M.A.2    Lubsen, J.3    Solomon, S.D.4
  • 18
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial
    • Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-3123
    • (2002) JAMA , vol.288 , pp. 3115-3123
    • Wilkoff, B.L.1    Cook, J.R.2    Epstein, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.