메뉴 건너뛰기




Volumn 37, Issue 9, 2010, Pages 4854-4860

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Author keywords

compensators; intensity modulation; MLC

Indexed keywords

BIOMEDICAL ENGINEERING; COST EFFECTIVENESS; LINEAR ACCELERATORS; RANDOM ERRORS; SYSTEMATIC ERRORS;

EID: 77956322429     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3476413     Document Type: Article
Times cited : (12)

References (35)
  • 1
    • 0036117951 scopus 로고    scopus 로고
    • Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy
    • MPHYA6 0094-2405,. 10.1118/1.1463063
    • J. A. Rawlinson, M. K. Islam, and D. M. Galbraith, " Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy.," Med. Phys. MPHYA6 0094-2405 29, 598-608 (2002). 10.1118/1.1463063
    • (2002) Med. Phys. , vol.29 , pp. 598-608
    • Rawlinson, J.A.1    Islam, M.K.2    Galbraith, D.M.3
  • 2
    • 3042548119 scopus 로고    scopus 로고
    • An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors
    • MPHYA6 0094-2405 .10.1118/1.1751011
    • A. M. Stell, J. G. Li, O. A. Zeidan, and J. F. Dempsey, " An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors.," Med. Phys. MPHYA6 0094-2405 31 (6), 1593-1602 (2004). 10.1118/1.1751011
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1593-1602
    • Stell, A.M.1    Li, J.G.2    Zeidan, O.A.3    Dempsey, J.F.4
  • 3
    • 38049001015 scopus 로고    scopus 로고
    • Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer
    • PHMBA7 0031-9155,. 10.1088/0031-9155/53/1/005
    • G. Mu, E. Ludlum, and P. Xia, " Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer.," Phys. Med. Biol. PHMBA7 0031-9155 53, 77-88 (2008). 10.1088/0031-9155/53/1/005
    • (2008) Phys. Med. Biol. , vol.53 , pp. 77-88
    • Mu, G.1    Ludlum, E.2    Xia, P.3
  • 4
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose deliver: Statistical analysis and simulation
    • PHMBA7 0031-9155,. 10.1088/0031-9155/47/13/302
    • T. Bortfeld, K. Jokivarsi, M. Goitein, J. Kung, and S. B. Jiang, " Effects of intra-fraction motion on IMRT dose deliver: statistical analysis and simulation.," Phys. Med. Biol. PHMBA7 0031-9155 47, 2203-2220 (2002). 10.1088/0031-9155/47/13/302
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 5
    • 0034078005 scopus 로고    scopus 로고
    • Intensity modulation delivery techniques: "step & shoot" MLC auto-sequence versus the use of a modulator
    • MPHYA6 0094-2405,. 10.1118/1.598989
    • S. X. Chang, T. J. Cullip, and K. M. Deschesne, " Intensity modulation delivery techniques: "step & shoot" MLC auto-sequence versus the use of a modulator.," Med. Phys. MPHYA6 0094-2405 27, 948-959 (2000). 10.1118/1.598989
    • (2000) Med. Phys. , vol.27 , pp. 948-959
    • Chang, S.X.1    Cullip, T.J.2    Deschesne, K.M.3
  • 7
    • 0031805413 scopus 로고    scopus 로고
    • On compensator design for photon beam intensity-modulated conformal therapy
    • MPHYA6 0094-2405,. 10.1118/1.598250
    • S. B. Jiang and K. M. Ayyangar, " On compensator design for photon beam intensity-modulated conformal therapy.," Med. Phys. MPHYA6 0094-2405 25, 668-675 (1998). 10.1118/1.598250
    • (1998) Med. Phys. , vol.25 , pp. 668-675
    • Jiang, S.B.1    Ayyangar, K.M.2
  • 8
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • MPHYA6 0094-2405,. 10.1118/1.1567831
    • P. A. Jursinic and B. E. Nelms, " A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.," Med. Phys. MPHYA6 0094-2405 30, 870-879 (2003). 10.1118/1.1567831
    • (2003) Med. Phys. , vol.30 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 9
    • 0034986809 scopus 로고    scopus 로고
    • Intensity modulated irradiation of a thorax phantom: Comparisons between measurements, Monte Carlo calculations and pencil beam calculations
    • PHMBA7 0031-9155,. 10.1088/0031-9155/46/6/308
    • W. U. Laub, A. Bakai, and F. Nusslin, " Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations.," Phys. Med. Biol. PHMBA7 0031-9155 46, 1695-1706 (2001). 10.1088/0031-9155/46/6/308
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1695-1706
    • Laub, W.U.1    Bakai, A.2    Nusslin, F.3
  • 10
    • 33748880997 scopus 로고    scopus 로고
    • Accommodating practical constraints for intensity modulated radiation therapy by means of compensators
    • MPHYA6 0094-2405,. 10.1118/1.1429625
    • J. Meyer, " Accommodating practical constraints for intensity modulated radiation therapy by means of compensators.," Med. Phys. MPHYA6 0094-2405 29, 103 (2002). 10.1118/1.1429625
    • (2002) Med. Phys. , vol.29 , pp. 103
    • Meyer, J.1
  • 11
    • 0033848727 scopus 로고    scopus 로고
    • Some limitations in the practical delivery of intensity modulated radiation therapy
    • BJRAAP 0007-1285
    • J. Meyer, J. A. Mills, O. C. Haas, E. M. Parvin, and K. J. Burnham, " Some limitations in the practical delivery of intensity modulated radiation therapy.," Br. J. Radiol. BJRAAP 0007-1285 73, 854-863 (2000).
    • (2000) Br. J. Radiol. , vol.73 , pp. 854-863
    • Meyer, J.1    Mills, J.A.2    Haas, O.C.3    Parvin, E.M.4    Burnham, K.J.5
  • 13
    • 26444553262 scopus 로고    scopus 로고
    • IMRT with compensators for head-and-neck cancers treatment technique, dosimetric accuracy, and practical experiences
    • STONE4 0179-7158,. 10.1007/s00066-005-1402-y
    • H. Salz, T. Wiezorek, M. Scheithauer, M. Schwedas, J. Beck, and T. G. Wendt, " IMRT with compensators for head-and-neck cancers treatment technique, dosimetric accuracy, and practical experiences.," Strahlenther. Onkol. STONE4 0179-7158 181, 665-672 (2005). 10.1007/s00066-005-1402-y
    • (2005) Strahlenther. Onkol. , vol.181 , pp. 665-672
    • Salz, H.1    Wiezorek, T.2    Scheithauer, M.3    Schwedas, M.4    Beck, J.5    Wendt, T.G.6
  • 15
    • 0038586578 scopus 로고    scopus 로고
    • A multiportal compensator system for IMRT delivery
    • MPHYA6 0094-2405,. 10.1118/1.1567851
    • K. Yoda and Y. Aoki, " A multiportal compensator system for IMRT delivery.," Med. Phys. MPHYA6 0094-2405 30, 880-886 (2003). 10.1118/1.1567851
    • (2003) Med. Phys. , vol.30 , pp. 880-886
    • Yoda, K.1    Aoki, Y.2
  • 16
    • 33745331781 scopus 로고    scopus 로고
    • Compensator-based intensity-modulated radiotherapy in head and neck cancer: Our experience in achieving dosimetric parameters and their clinical correlation
    • ZZZZZZ 0936-6555 ()
    • S. Nangia, K. S. Chufal, V. Arivazhagan, P. Srinivas, A. Tyagi, and D. Ghosh, " Compensator-based intensity-modulated radiotherapy in head and neck cancer: our experience in achieving dosimetric parameters and their clinical correlation.," Clin. Oncol. (R Coll. Radiol) ZZZZZZ 0936-6555 18 (6), 485-492 (2006).
    • (2006) Clin. Oncol. (R Coll. Radiol) , vol.18 , Issue.6 , pp. 485-492
    • Nangia, S.1    Chufal, K.S.2    Arivazhagan, V.3    Srinivas, P.4    Tyagi, A.5    Ghosh, D.6
  • 17
    • 33745662433 scopus 로고    scopus 로고
    • Can dose reduction to one parotid gland prevent xerostomia? A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy
    • ZZZZZZ 0936-6555 ()
    • A. K. Anand, J. Jain, P. S. Negi, A. R. Chaudhoory, S. N. Sinha, P. S. Choudhury, R. Kumar, and R. K. Munjal, " Can dose reduction to one parotid gland prevent xerostomia? A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy.," Clin. Oncol. (R Coll. Radiol) ZZZZZZ 0936-6555 18 (6), 497-504 (2006).
    • (2006) Clin. Oncol. (R Coll. Radiol) , vol.18 , Issue.6 , pp. 497-504
    • Anand, A.K.1    Jain, J.2    Negi, P.S.3    Chaudhoory, A.R.4    Sinha, S.N.5    Choudhury, P.S.6    Kumar, R.7    Munjal, R.K.8
  • 18
    • 0032761378 scopus 로고    scopus 로고
    • A comparison of different intensity modulation treatment techniques for tangential breast irradiation
    • IOBPD3 0360-3016,. 10.1016/S0360-3016(99)00344-2
    • S. X. Chang, K. M. Deschesne, T. J. Cullip, S. A. Parker, and J. Earnhart, " A comparison of different intensity modulation treatment techniques for tangential breast irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 45, 1305-1314 (1999). 10.1016/S0360-3016(99)00344- 2
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.45 , pp. 1305-1314
    • Chang, S.X.1    Deschesne, K.M.2    Cullip, T.J.3    Parker, S.A.4    Earnhart, J.5
  • 20
    • 85024954535 scopus 로고    scopus 로고
    • Compensators: An alternative IMRT delivery technique
    • JACMFG 1526-9914 .10.1120/jacm2021.25274
    • S. X. Chang, T. J. Cullip, K. M. Deschesne, E. P. Miller, and J. G. Rosenman, " Compensators: an alternative IMRT delivery technique.," J. Appl. Clin. Med. Phys. JACMFG 1526-9914 5 (3), 15-36 (2004). 10.1120/jacmp.2021.25274
    • (2004) J. Appl. Clin. Med. Phys. , vol.5 , Issue.3 , pp. 15-36
    • Chang, S.X.1    Cullip, T.J.2    Deschesne, K.M.3    Miller, E.P.4    Rosenman, J.G.5
  • 24
    • 34347401026 scopus 로고    scopus 로고
    • Investigation of the reliability, accuracy, and efficiency of gated IMRT delivery with a commercial linear accelerator
    • MPHYA6 0094-2405,. 10.1118/1.2740009
    • E. Ahunbay and X. A. Li, " Investigation of the reliability, accuracy, and efficiency of gated IMRT delivery with a commercial linear accelerator.," Med. Phys. MPHYA6 0094-2405 34, 2928-2938 (2007). 10.1118/1.2740009
    • (2007) Med. Phys. , vol.34 , pp. 2928-2938
    • Ahunbay, E.1    Li, X.A.2
  • 25
    • 0009844750 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of intensity-modulated fields with a multileaf collimator (Abstract)
    • MPHYA6 0094-2405
    • C. Chui, " The effects of intra-fraction organ motion on the delivery of intensity-modulated fields with a multileaf collimator (Abstract).," Med. Phys. MPHYA6 0094-2405 26, 1087 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1087
    • Chui, C.1
  • 26
    • 0035185056 scopus 로고    scopus 로고
    • Measured dose errors in IMRT delivered with DMLC in the presence of organ motion: A phantom study (Abstract)
    • MPHYA6 0094-2405,. 10.1118/1.1408284
    • P. Zygmanski, J. H. Kung, S. B. Jiang, and L. Chin, " Measured dose errors in IMRT delivered with DMLC in the presence of organ motion: A phantom study (Abstract).," Med. Phys. MPHYA6 0094-2405 28, 1283 (2001). 10.1118/1.1408284
    • (2001) Med. Phys. , vol.28 , pp. 1283
    • Zygmanski, P.1    Kung, J.H.2    Jiang, S.B.3    Chin, L.4
  • 27
    • 34047271046 scopus 로고    scopus 로고
    • On the dose to a moving target while employing different IMRT delivery mechanisms
    • RAONDT 0167-8140,. 10.1016/j.radonc.2007.02.007
    • E. D. Ehler, B. E. Nelms, and W. A. Tome, " On the dose to a moving target while employing different IMRT delivery mechanisms.," Radiother. Oncol. RAONDT 0167-8140 83, 49-56 (2007). 10.1016/j.radonc.2007.02.007
    • (2007) Radiother. Oncol. , vol.83 , pp. 49-56
    • Ehler, E.D.1    Nelms, B.E.2    Tome, W.A.3
  • 28
    • 0037573250 scopus 로고    scopus 로고
    • Validation of dynamic MLC-controller log files using a two-dimensional diode array
    • MPHYA6 0094-2405,. 10.1118/1.1567951
    • J. G. Li, J. F. Dempsey, L. Ding, C. Liu, and J. R. Palta, " Validation of dynamic MLC-controller log files using a two-dimensional diode array.," Med. Phys. MPHYA6 0094-2405 30, 799-805 (2003). 10.1118/1.1567951
    • (2003) Med. Phys. , vol.30 , pp. 799-805
    • Li, J.G.1    Dempsey, J.F.2    Ding, L.3    Liu, C.4    Palta, J.R.5
  • 29
    • 1642377027 scopus 로고    scopus 로고
    • Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device
    • MPHYA6 0094-2405,. 10.1118/1.1644518
    • O. A. Zeidan, J. G. Li, M. Ranade, A. M. Stell, and J. F. Dempsey, " Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device.," Med. Phys. MPHYA6 0094-2405 31, 463-476 (2004). 10.1118/1.1644518
    • (2004) Med. Phys. , vol.31 , pp. 463-476
    • Zeidan, O.A.1    Li, J.G.2    Ranade, M.3    Stell, A.M.4    Dempsey, J.F.5
  • 30
    • 0142057574 scopus 로고    scopus 로고
    • Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number
    • MPHYA6 0094-2405,. 10.1118/1.1598674
    • P. Zygmanski, J. H. Kung, S. B. Jiang, and L. Chin, " Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number.," Med. Phys. MPHYA6 0094-2405 30, 2736-2749 (2003). 10.1118/1.1598674
    • (2003) Med. Phys. , vol.30 , pp. 2736-2749
    • Zygmanski, P.1    Kung, J.H.2    Jiang, S.B.3    Chin, L.4
  • 31
    • 0030809842 scopus 로고    scopus 로고
    • Quality control aspects of the Philips multileaf collimator
    • RAONDT 0167-8140,. 10.1016/S0167-8140(97)00100-X
    • A. R. Hounsell and T. J. Jordan, " Quality control aspects of the Philips multileaf collimator.," Radiother. Oncol. RAONDT 0167-8140 45, 225-233 (1997). 10.1016/S0167-8140(97)00100-X
    • (1997) Radiother. Oncol. , vol.45 , pp. 225-233
    • Hounsell, A.R.1    Jordan, T.J.2
  • 32
    • 17844379267 scopus 로고    scopus 로고
    • Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy
    • MPHYA6 0094-2405,. 10.1118/1.1876581
    • K. Wijesooriya, C. Bartee, J. V. Siebers, S. S. Vedam, and P. J. Keall, " Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: implications for 4D radiotherapy.," Med. Phys. MPHYA6 0094-2405 32, 932-941 (2005). 10.1118/1.1876581
    • (2005) Med. Phys. , vol.32 , pp. 932-941
    • Wijesooriya, K.1    Bartee, C.2    Siebers, J.V.3    Vedam, S.S.4    Keall, P.J.5
  • 33
    • 33748312239 scopus 로고    scopus 로고
    • Evaluation of two methods of predicting MLC leaf positions using EPID measurements
    • MPHYA6 0094-2405,. 10.1118/1.2335490
    • L. Parent, J. Seco, P. M. Evans, D. R. Dance, and A. Fielding, " Evaluation of two methods of predicting MLC leaf positions using EPID measurements.," Med. Phys. MPHYA6 0094-2405 33, 3174-3182 (2006). 10.1118/1.2335490
    • (2006) Med. Phys. , vol.33 , pp. 3174-3182
    • Parent, L.1    Seco, J.2    Evans, P.M.3    Dance, D.R.4    Fielding, A.5
  • 34
    • 34748837954 scopus 로고    scopus 로고
    • The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy
    • PHMBA7 0031-9155,. 10.1088/0031-9155/52/19/N03
    • R. P. Srivastava and C. De Wagter, " The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 52, N449-457 (2007). 10.1088/0031-9155/52/19/ N03
    • (2007) Phys. Med. Biol. , vol.52 , pp. 449-457
    • Srivastava, R.P.1    De Wagter, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.