메뉴 건너뛰기




Volumn 53, Issue 1, 2008, Pages 77-88

Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; DOSIMETRY; OPTICAL COLLIMATORS; RADIOTHERAPY;

EID: 38049001015     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/1/005     Document Type: Article
Times cited : (93)

References (15)
  • 1
    • 0038587417 scopus 로고    scopus 로고
    • MLC quality assurance techniques for IMRT applications
    • Bayouth J E, Wendt D and Morrill S M 2003 MLC quality assurance techniques for IMRT applications Med. Phys. 30 743-50
    • (2003) Med. Phys. , vol.30 , Issue.5 , pp. 743-750
    • Bayouth, J.E.1    Wendt, D.2    Morrill, S.M.3
  • 2
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • Chuang C F, Verhey L J and Xia P 2002 Investigation of the use of MOSFET for clinical IMRT dosimetric verification Med. Phys. 29 1109-15
    • (2002) Med. Phys. , vol.29 , Issue.6 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 3
    • 0023858102 scopus 로고
    • An approach to the interpretation of clinical data on the tumour control probability-dose relationship
    • Dutreix J, Tubiana M and Dutreix A 1988 An approach to the interpretation of clinical data on the tumour control probability-dose relationship Radiother. Oncol. 11 239-48
    • (1988) Radiother. Oncol. , vol.11 , Issue.3 , pp. 239-248
    • Dutreix, J.1    Tubiana, M.2    Dutreix, A.3
  • 4
    • 0036797460 scopus 로고    scopus 로고
    • Dosimetry of therapeutic photon beams using an extended dose range film
    • Esthappan J, Mutic S, Harms W B, Dempsey J F and Low D A 2002 Dosimetry of therapeutic photon beams using an extended dose range film Med. Phys. 29 2438-45
    • (2002) Med. Phys. , vol.29 , Issue.10 , pp. 2438-2445
    • Esthappan, J.1    Mutic, S.2    Harms, W.B.3    Dempsey, J.F.4    Low, D.A.5
  • 5
    • 33744577456 scopus 로고    scopus 로고
    • Verification of dynamic and segmental IMRT delivery by dynamic log file analysis
    • Litzenberg D W, Moran J M and Fraass B A 2002 Verification of dynamic and segmental IMRT delivery by dynamic log file analysis J. Appl. Clin. Med. Phys. 3 63-72
    • (2002) J. Appl. Clin. Med. Phys. , vol.3 , Issue.2 , pp. 63-72
    • Litzenberg, D.W.1    Moran, J.M.2    Fraass, B.A.3
  • 6
    • 0035192124 scopus 로고    scopus 로고
    • Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    • LoSasso T, Chui C S and Ling C C 2001 Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode Med. Phys. 28 2209-19
    • (2001) Med. Phys. , vol.28 , Issue.11 , pp. 2209-2219
    • Losasso, T.1    Chui, C.S.2    Ling, C.C.3
  • 9
    • 0036735811 scopus 로고    scopus 로고
    • Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance
    • Olch A J 2002 Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance Med. Phys. 29 2159-68
    • (2002) Med. Phys. , vol.29 , Issue.9 , pp. 2159-2168
    • Olch, A.J.1
  • 11
    • 3042548119 scopus 로고    scopus 로고
    • An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors
    • Stell A M, Li J G, Zeidan O A and Dempsey J F 2004 An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors Med. Phys. 31 1593-602
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1593-1602
    • Stell, A.M.1    Li, J.G.2    Zeidan, O.A.3    Dempsey, J.F.4
  • 12
    • 18844441645 scopus 로고    scopus 로고
    • Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements
    • Woo M K and Nico A 2005 Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements Med. Phys. 32 1440-5
    • (2005) Med. Phys. , vol.32 , Issue.5 , pp. 1440-1445
    • Woo, M.K.1    Nico, A.2
  • 14
    • 1642377027 scopus 로고    scopus 로고
    • Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device
    • Zeidan O A, Li J G, Ranade M, Stell A M and Dempsey J F 2004 Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device Med. Phys. 31 463-76
    • (2004) Med. Phys. , vol.31 , Issue.3 , pp. 463-476
    • Zeidan, O.A.1    Li, J.G.2    Ranade, M.3    Stell, A.M.4    Dempsey, J.F.5
  • 15
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    • Zhu X R, Jursinic P A, Grimm D F, Lopez F, Rownd J J and Gillin M T 2002 Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator Med. Phys. 29 1687-92
    • (2002) Med. Phys. , vol.29 , Issue.8 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.