Volumn 45, Issue 3, 1997, Pages 225-233

Quality control aspects of the Philips multileaf collimator

Author keywords

Multileaf collimators; Quality control

Indexed keywords

ARTICLE; CALIBRATION; COLLIMATOR; LINEAR ACCELERATOR; MEDICAL INSTRUMENTATION; PRIORITY JOURNAL; QUALITY CONTROL;

EID: 0030809842     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(97)00100-X     Document Type: Article
Times cited : (22)

References (14)
  • 1
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • AAPM (American Association of Physicists in Medicine)
    • AAPM (American Association of Physicists in Medicine). Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med. Phys. 21: 581-618, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 581-618
  • 2
    • 0028085967 scopus 로고
    • AAPM code of practice for radiotherapy accelerators: Report of AAPM Radiation Therapy Task Group No. 45
    • AAPM (American Association of Physicists in Medicine)
    • AAPM (American Association of Physicists in Medicine). AAPM code of practice for radiotherapy accelerators: Report of AAPM Radiation Therapy Task Group No. 45. Med. Phys. 21: 1093-1121, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1093-1121
  • 3
    • 0026785708 scopus 로고
    • Clinical dosimetry for implementation of a multi-leaf collimator
    • Boyer, A.L., Ochran, T.G., Nyerick, C.E. and Waldron, T.J. Clinical dosimetry for implementation of a multi-leaf collimator. Med. Phys. 19: 1255-1261, 1992.
    • (1992) Med. Phys. , vol.19 , pp. 1255-1261
    • Boyer, A.L.1    Ochran, T.G.2    Nyerick, C.E.3    Waldron, T.J.4
  • 6
    • 0028942156 scopus 로고
    • Dosimetric characteristics of a commercial multileaf collimator
    • Huq, S.M., Yu, Y., Chen, Z.-P. and Suntharalingam, N. Dosimetric characteristics of a commercial multileaf collimator. Med. Phys. 22: 241-247, 1995.
    • (1995) Med. Phys. , vol.22 , pp. 241-247
    • Huq, S.M.1    Yu, Y.2    Chen, Z.-P.3    Suntharalingam, N.4
  • 9
    • 0343159363 scopus 로고
    • Quality control of megavoltage therapy units
    • Editors: J.R. Williams and D.I. Thwaites. Oxford University Press, Oxford
    • Johansson, K.-A., Sernbo, G. and Van Dam, J. Quality control of megavoltage therapy units. In: Radiotherapy Physics in Practice, pp. 77-94. Editors: J.R. Williams and D.I. Thwaites. Oxford University Press, Oxford, 1993.
    • (1993) In: Radiotherapy Physics in Practice , pp. 77-94
    • Johansson, K.-A.1    Sernbo, G.2    Van Dam, J.3
  • 10
    • 0028346915 scopus 로고
    • The design and performance characteristics of a multi-leaf collimator
    • Jordan, T.J. and Williams, P.C. The design and performance characteristics of a multi-leaf collimator. Phys. Med. Biol. 39: 231-251, 1994.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 11
    • 0028845127 scopus 로고
    • Clinical implementation of a commercial multileaf collimator: Dosimetry, networking, simulation, and quality assurance
    • Klein, E.E., Harms, W.B., Low, D.A., Willcut, V. and Purdy, J.A. Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance. Int. J. Radiat. Oncol. Biol. Phys. 33: 1195-1208, 1995.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1195-1208
    • Klein, E.E.1    Harms, W.B.2    Low, D.A.3    Willcut, V.4    Purdy, J.A.5
  • 12
    • 0030061689 scopus 로고    scopus 로고
    • A quality assurance program for ancillary high technology devices on a dual-energy accelerator
    • Klein, E.E., Low, D.A., Maag, D. and Purdy, J.A. A quality assurance program for ancillary high technology devices on a dual-energy accelerator. Radiother. Oncol. 38: 51-60, 1996.
    • (1996) Radiother. Oncol. , vol.38 , pp. 51-60
    • Klein, E.E.1    Low, D.A.2    Maag, D.3    Purdy, J.A.4
  • 13
    • 0023916790 scopus 로고
    • Quality control of radiation therapy equipment
    • Rassow, J. Quality control of radiation therapy equipment. Radiother. Oncol. 12: 45-55, 1988.
    • (1988) Radiother. Oncol. , vol.12 , pp. 45-55
    • Rassow, J.1
  • 14
    • 0343594813 scopus 로고
    • Quality assurance in conformal radiation therapy
    • Editor: A.R. Smith. Springer-Verlag, Berlin
    • Rosen, I.I. Quality assurance in conformal radiation therapy. In: Radiation Therapy Physics, pp. 449-453. Editor: A.R. Smith. Springer-Verlag, Berlin, 1994.
    • (1994) In: Radiation Therapy Physics , pp. 449-453
    • Rosen, I.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.