Validation of dynamic MLC-controller log files using a two-dimensional diode array

Author keywords

IMRT; Intensity modulation; Multileaf collimator; Treatment verification

Indexed keywords

BIOMEDICAL ENGINEERING; COMPUTERIZED TOMOGRAPHY; LINEAR ACCELERATORS; MODULATION; QUALITY ASSURANCE;

EID: 0037573250     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1567951     Document Type: Article
Times cited : (70)

References (13)
  • 2
    • 0036430372 scopus 로고    scopus 로고
    • An automated phantom-film QA procedure for intensity-modulated radiation therapy
    • A. Kapulsky, E. Mullokandov, and G. Gejerman, "An automated phantom-film QA procedure for intensity-modulated radiation therapy," Med. Dosim 27, 201-207 (2002).
    • (2002) Med. Dosim , vol.27 , pp. 201-207
    • Kapulsky, A.1    Mullokandov, E.2    Gejerman, G.3
  • 3
    • 85024960150 scopus 로고    scopus 로고
    • Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system
    • M. A. MacKenzie, M. Lachaine, B. Murray, B. G. Fallone, D. Robinson, and G. C. Field, "Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system," J. Appl. Clin. Med. Phys. 3, 97-109 (2002).
    • (2002) J. Appl. Clin. Med. Phys. , vol.3 , pp. 97-109
    • MacKenzie, M.A.1    Lachaine, M.2    Murray, B.3    Fallone, B.G.4    Robinson, D.5    Field, G.C.6
  • 4
    • 0029892226 scopus 로고    scopus 로고
    • Output stability of a linear accelerator during the first three seconds
    • R. Rajapakshe and S. Sharlev, "Output stability of a linear accelerator during the first three seconds," Med. Phys. 23, 517-519 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 517-519
    • Rajapakshe, R.1    Sharlev, S.2
  • 5
    • 0034499349 scopus 로고    scopus 로고
    • Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach
    • M. B. Sharpe, B. M. Miller, D. Yan, and J. W. Wong, "Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach," Med. Phys. 27, 2719-2725 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2719-2725
    • Sharpe, M.B.1    Miller, B.M.2    Yan, D.3    Wong, J.W.4
  • 8
    • 0036127055 scopus 로고    scopus 로고
    • Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system
    • P. Xia, C. F. Chuang, and L. J. Verhey, "Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system," Med. Phys. 29, 412-423 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 412-423
    • Xia, P.1    Chuang, C.F.2    Verhey, L.J.3
  • 9
    • 85024994025 scopus 로고    scopus 로고
    • The overshoot phenomenon in step-and-shoot IMRT delivery
    • G. A. Ezzell and S. Chungbin, "The overshoot phenomenon in step-and-shoot IMRT delivery," J. Appl. Clin. Med. Phys. 2, 138-148 (2001).
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , pp. 138-148
    • Ezzell, G.A.1    Chungbin, S.2
  • 10
    • 33646615736 scopus 로고    scopus 로고
    • Dosimetric effects of segment MU redistribution on step-and-shoot IMRT patient dose
    • J. G. Li, J. F. Dempsey, O. Zeiden, C. Liu, and J. R. Palta, "Dosimetric effects of segment MU redistribution on step-and-shoot IMRT patient dose," Med. Phys. 29, 1315 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1315
    • Li, J.G.1    Dempsey, J.F.2    Zeiden, O.3    Liu, C.4    Palta, J.R.5
  • 11
    • 33744577456 scopus 로고    scopus 로고
    • Verification of dynamic and segmental IMRT delivery by dynamic log file analysis
    • D. W. Litzenberg, J. M. Moran, and B. A. Fraass, "Verification of dynamic and segmental IMRT delivery by dynamic log file analysis," J. Appl. Clin. Med. Phys. 3. 63-72 (2002).
    • (2002) J. Appl. Clin. Med. Phys. , vol.3 , pp. 63-72
    • Litzenberg, D.W.1    Moran, J.M.2    Fraass, B.A.3
  • 13
    • 0035192124 scopus 로고    scopus 로고
    • Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    • T. LoSasso, C.-S. Chui, and C. C. Ling, "Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode," Med. Phys. 28, 2209-2219 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2209-2219
    • LoSasso, T.1    Chui, C.-S.2    Ling, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.