메뉴 건너뛰기




Volumn 25, Issue 5, 1998, Pages 668-675

On compensator design for photon beam intensity-modulated conformal therapy

Author keywords

Compensator; Conformal therapy; Intensity modulation; Monte Carlo

Indexed keywords

COMPUTERIZED TOMOGRAPHY; HARDENING; LIGHT SCATTERING; MONTE CARLO METHODS; PARTICLE BEAMS; PHOTOELECTRONS; RADIOTHERAPY; SPECTROSCOPY; SURFACE SCATTERING;

EID: 0031805413     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598250     Document Type: Article
Times cited : (74)

References (19)
  • 1
    • 0023695955 scopus 로고
    • The field integrated dose modification (FIDM): Three typical clinical applications of a new irradiation technique
    • F. Brix, R. Christiansen, C. Hancken, and A. Quirin, "The field integrated dose modification (FIDM): three typical clinical applications of a new irradiation technique," Radiother. Oncol. 12, 199-207 (1988).
    • (1988) Radiother. Oncol. , vol.12 , pp. 199-207
    • Brix, F.1    Christiansen, R.2    Hancken, C.3    Quirin, A.4
  • 3
  • 4
    • 0025759291 scopus 로고
    • 3-D dose volume compensation using nonlinear least squares regression technique
    • K. J. Weeks and M. R. Sontag, "3-D dose volume compensation using nonlinear least squares regression technique," Med. Phys. 18, 474-480 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 474-480
    • Weeks, K.J.1    Sontag, M.R.2
  • 5
    • 0027257435 scopus 로고
    • Optimization of the dose delivery in a few field techniques using radiobiological objective functions
    • S. Sodertrom and A. Brahme, "Optimization of the dose delivery in a few field techniques using radiobiological objective functions," Med. Phys. 20, 1201-1210 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1201-1210
    • Sodertrom, S.1    Brahme, A.2
  • 6
    • 33744709198 scopus 로고
    • A new approach to achieve treatment volume dose homogeneity using compensators
    • T. Cullip, A. Jones, S. X. Chang, and E. Chaney, "A new approach to achieve treatment volume dose homogeneity using compensators," Med. Phys. 21, 938 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 938
    • Cullip, T.1    Jones, A.2    Chang, S.X.3    Chaney, E.4
  • 7
    • 0029083838 scopus 로고
    • Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm
    • A. Gustafsson, B. K. Lind, R. Svensson, and A. Brahme, "Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm," Med. Phys. 22, 1141-1156 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1141-1156
    • Gustafsson, A.1    Lind, B.K.2    Svensson, R.3    Brahme, A.4
  • 8
    • 0001126836 scopus 로고    scopus 로고
    • Dose gradient optimization via compensator: Construction and clinical quality assurance
    • E. P. Miller, S. X. Chang, J. Rosenman, and T. Cullip, "Dose gradient optimization via compensator: construction and clinical quality assurance," Med Phys. 23, 1170 (1996).
    • (1996) Med Phys. , vol.23 , pp. 1170
    • Miller, E.P.1    Chang, S.X.2    Rosenman, J.3    Cullip, T.4
  • 12
    • 0001041567 scopus 로고
    • Monte Carlo techniques of electron and photon transport for radiation dosimetry
    • edited by K. R. Case, B. E. Bjarngard, and F. H. Attix Academic, New York
    • D. W O. Rogers and A. F. Bielajew, "Monte Carlo techniques of electron and photon transport for radiation dosimetry," in The Dosimetry of Ionizing Radiation, edited by K. R. Case, B. E. Bjarngard, and F. H. Attix (Academic, New York, 1990), Vol. 3, pp. 427-539.
    • (1990) The Dosimetry of Ionizing Radiation , vol.3 , pp. 427-539
    • Rogers, D.W.O.1    Bielajew, A.F.2
  • 13
    • 0026689145 scopus 로고
    • A standard timing benchmark for EGS4 Monte Carlo calculations
    • A. F. Bielajew and D. W O. Rogers, "A standard timing benchmark for EGS4 Monte Carlo calculations," Med. Phys. 19, 303-304 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 303-304
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 14
    • 0010508143 scopus 로고    scopus 로고
    • Calculation of dosimetric data for small field sizes for 6 MV x-rays using BEAM/DOSXYZ Monte Carlo codes
    • K. M. Ayyangar and S. B. Jiang, "Calculation of dosimetric data for small field sizes for 6 MV x-rays using BEAM/DOSXYZ Monte Carlo codes," Med. Phys. 23, 1129 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1129
    • Ayyangar, K.M.1    Jiang, S.B.2
  • 15
    • 0344035392 scopus 로고    scopus 로고
    • Characteristics of radiosurgery beams from a Clinac 1800 accelerator: A Monte Carlo study
    • Salt Lake City, UT, 1997, edited by D. D. Leavitt and G. Starkschall Medical Physics, Madison, WI
    • S. B. Jiang and K. M. Ayyangar, "Characteristics of radiosurgery beams from a Clinac 1800 accelerator: a Monte Carlo study," in Proceedings of The 12th International Conference on The Use of Computers in Radiation Therapy, Salt Lake City, UT, 1997, edited by D. D. Leavitt and G. Starkschall (Medical Physics, Madison, WI, 1997), pp. 86-87.
    • (1997) Proceedings of the 12th International Conference on the Use of Computers in Radiation Therapy , pp. 86-87
    • Jiang, S.B.1    Ayyangar, K.M.2
  • 16
    • 0344035391 scopus 로고    scopus 로고
    • An investigation on the feasibility of using OMEGA Monte Carlo codes for radiosurgery treatment planning
    • Salt Lake City, UT, 1997, edited by D. D. Leavitt and G. Starkschall Medical Physics, Madison, WI
    • K. M. Ayyangar and S. B. Jiang, "An investigation on the feasibility of using OMEGA Monte Carlo codes for radiosurgery treatment planning," in Proceedings of The 12th International Conference on The Use of Computers in Radiation Therapy, Salt Lake City, UT, 1997, edited by D. D. Leavitt and G. Starkschall (Medical Physics, Madison, WI, 1997), pp. 88-89
    • (1997) Proceedings of the 12th International Conference on the Use of Computers in Radiation Therapy , pp. 88-89
    • Ayyangar, K.M.1    Jiang, S.B.2
  • 17
    • 0344466517 scopus 로고    scopus 로고
    • Monte Carlo and experimental study of the perturbation caused by inhomogeneity in radiosurgical fields
    • Salt Lake City, UT, 1997, edited by D D Leavitt and G. Starkschall Medical Physics, Madison, WI
    • S. B. Jiang, S. N. Rustgi, A K Rustgi, and K. M. Ayyangar, "Monte Carlo and experimental study of the perturbation caused by inhomogeneity in radiosurgical fields," in Proceedings of The 12th International Conference on The Use of Computers in Radiation Therapy, Salt Lake City, UT, 1997, edited by D D Leavitt and G. Starkschall (Medical Physics, Madison, WI, 1997), p. 485.
    • (1997) Proceedings of the 12th International Conference on the Use of Computers in Radiation Therapy , pp. 485
    • Jiang, S.B.1    Rustgi, S.N.2    Rustgi, A.K.3    Ayyangar, K.M.4
  • 19
    • 0018758746 scopus 로고
    • Improving the buildup and depth-dose characteristics of high energy photon beams by using electron filters
    • C C. Ling and P. J. Biggs, "Improving the buildup and depth-dose characteristics of high energy photon beams by using electron filters," Med. Phys. 6, 296-301 (1979).
    • (1979) Med. Phys. , vol.6 , pp. 296-301
    • Ling, C.C.1    Biggs, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.