Volumn 13, Issue SUPPL. 1, 2010, Pages 80-85

Accuracy and reproducibility of the TonoVet® rebound tonometer in birds of prey

Author keywords

Calibration; Intraocular pressure; Manometry; Raptors; Rebound tonometry

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; INSTRUMENTATION; INTRAOCULAR PRESSURE; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY; RAPTOR; REPRODUCIBILITY; VISUAL SYSTEM FUNCTION;

EID: 77956271821     PISSN: 14635216     EISSN: 14635224     Source Type: Journal    
DOI: 10.1111/j.1463-5224.2010.00817.x     Document Type: Article
Times cited : (50)

References (24)
  • 2
    • 77956287642 scopus 로고    scopus 로고
    • Physiologische und messtechnische Prinzipien der Augendruckmessung
    • Draeger J, Rumberger E. eds, Rethra Verlag, Neubrandenburg
    • Rumberger E. Physiologische und messtechnische Prinzipien der Augendruckmessung. Tonometrie 2008, 3-48. Draeger JRumberger E. eds, Rethra Verlag, Neubrandenburg
    • (2008) Tonometrie , pp. 3-48
    • Rumberger, E.1
  • 3
    • 42549147371 scopus 로고    scopus 로고
    • Ophthalmic examination findings in a colony of Screech owls (Megascops asio)
    • Harris MC, Schorling JJ, Herring IP. Ophthalmic examination findings in a colony of Screech owls (Megascops asio). Veterinary Ophthalmology 2008, 11:186-192.
    • (2008) Veterinary Ophthalmology , vol.11 , pp. 186-192
    • Harris, M.C.1    Schorling, J.J.2    Herring, I.P.3
  • 4
    • 35449005286 scopus 로고    scopus 로고
    • Comparison of the rebound tonometer (TonoVet) with the applanation tonometer (TonoPen XL) in normal Eurasian eagle owls (Bubo bubo)
    • Jeong MB, Kim YJ, Yi NY. Comparison of the rebound tonometer (TonoVet) with the applanation tonometer (TonoPen XL) in normal Eurasian eagle owls (Bubo bubo). Veterinary Ophthalmology 2007, 10:376-379.
    • (2007) Veterinary Ophthalmology , vol.10 , pp. 376-379
    • Jeong, M.B.1    Kim, Y.J.2    Yi, N.Y.3
  • 5
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmologica Scandinavica 2000, 78:142-145.
    • (2000) Acta Ophthalmologica Scandinavica , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 6
    • 33645231808 scopus 로고    scopus 로고
    • Comparison of the use of new handheld tonometers and established applanation tonometers in dogs
    • Görig C, Coenen RT, Stades FC. Comparison of the use of new handheld tonometers and established applanation tonometers in dogs. American Journal of Veterinary Research 2006, 67:134-144.
    • (2006) American Journal of Veterinary Research , vol.67 , pp. 134-144
    • Görig, C.1    Coenen, R.T.2    Stades, F.C.3
  • 7
    • 34948836324 scopus 로고    scopus 로고
    • Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies
    • Prashar A, Guggenheim JA, Erichsen JT. Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies. Experimental Eye Research 2007, 85:563-571.
    • (2007) Experimental Eye Research , vol.85 , pp. 563-571
    • Prashar, A.1    Guggenheim, J.A.2    Erichsen, J.T.3
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 34250774109 scopus 로고    scopus 로고
    • Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers
    • Kalesnykas G, Uusitalo H. Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers. Graefes Archive for Clinical and Experimental Ophthalmology 2007, 245:761-762.
    • (2007) Graefes Archive for Clinical and Experimental Ophthalmology , vol.245 , pp. 761-762
    • Kalesnykas, G.1    Uusitalo, H.2
  • 14
    • 0036946949 scopus 로고    scopus 로고
    • Non-invasive determination of intraocular pressure in the rat eye Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer
    • Goldblum D, Kontiola AI, Mittag T. Non-invasive determination of intraocular pressure in the rat eye Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer. Graefe's Archive for Clinical and Experimental Ophthalmology 2002, 240:942-946.
    • (2002) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.240 , pp. 942-946
    • Goldblum, D.1    Kontiola, A.I.2    Mittag, T.3
  • 16
    • 33751060567 scopus 로고    scopus 로고
    • Manometric calibration and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice
    • Pease ME, Hammond JC, Quigley HA. Manometric calibration and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice. Journal of Glaucoma 2006, 15:512-519.
    • (2006) Journal of Glaucoma , vol.15 , pp. 512-519
    • Pease, M.E.1    Hammond, J.C.2    Quigley, H.A.3
  • 18
    • 58149123724 scopus 로고    scopus 로고
    • Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry
    • Jorge JM, Gonzalez-Meijome JM, Queiros A. Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry. Journal of Glaucoma 2008, 17:442-448.
    • (2008) Journal of Glaucoma , vol.17 , pp. 442-448
    • Jorge, J.M.1    Gonzalez-Meijome, J.M.2    Queiros, A.3
  • 19
    • 63449097295 scopus 로고    scopus 로고
    • Comparison of rebound tonometer and Goldmann handheld applanation tonometer in congenital glaucoma
    • Martinez-de-la-Casa JM, Garcia-Feijoo J, Saenz-Frances F. Comparison of rebound tonometer and Goldmann handheld applanation tonometer in congenital glaucoma. Journal of Glaucoma 2009, 18:49-52.
    • (2009) Journal of Glaucoma , vol.18 , pp. 49-52
    • Martinez-de-la-Casa, J.M.1    Garcia-Feijoo, J.2    Saenz-Frances, F.3
  • 20
    • 33751505840 scopus 로고    scopus 로고
    • Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry
    • Martinez-de-la-Casa JM, Garcia-Feijoo J, Vico E. Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry. Ophthalmology 2006, 113:2156-2162.
    • (2006) Ophthalmology , vol.113 , pp. 2156-2162
    • Martinez-de-la-Casa, J.M.1    Garcia-Feijoo, J.2    Vico, E.3
  • 21
    • 77956286463 scopus 로고    scopus 로고
    • Evaluation of intraocular pressure obtained by two tonometers, and their correlations with corneal thickness obtained by pachymetry in raptors (abstract)
    • Bayón A, Vecino E, Albert A. Evaluation of intraocular pressure obtained by two tonometers, and their correlations with corneal thickness obtained by pachymetry in raptors (abstract). Veterinary Ophthalmology 2006, 9:432.
    • (2006) Veterinary Ophthalmology , vol.9 , pp. 432
    • Bayón, A.1    Vecino, E.2    Albert, A.3
  • 22
    • 67349134656 scopus 로고    scopus 로고
    • Recovery of corneal hysteresis after reduction of intraocular pressure in chronic primary angle- closure glaucoma
    • Sun L, Shen M, Wang J. Recovery of corneal hysteresis after reduction of intraocular pressure in chronic primary angle- closure glaucoma. American Journal of Ophthalmology 2009, 147:1061-1066.
    • (2009) American Journal of Ophthalmology , vol.147 , pp. 1061-1066
    • Sun, L.1    Shen, M.2    Wang, J.3
  • 23
    • 37349001245 scopus 로고    scopus 로고
    • The influence of corneal properties on rebound tonometry
    • Chui WS, Lam A, Chen D. The influence of corneal properties on rebound tonometry. Ophthalmology 2008, 115:80-84.
    • (2008) Ophthalmology , vol.115 , pp. 80-84
    • Chui, W.S.1    Lam, A.2    Chen, D.3
  • 24
    • 34247567827 scopus 로고    scopus 로고
    • Rebound tonometer compared with goldmann tonometer in normal and pathologic corneas
    • Moreno-Montanes J, Garcia N, Fernandez-Hortelano A. Rebound tonometer compared with goldmann tonometer in normal and pathologic corneas. Cornea 2007, 26:427-430.
    • (2007) Cornea , vol.26 , pp. 427-430
    • Moreno-Montanes, J.1    Garcia, N.2    Fernandez-Hortelano, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.