메뉴 건너뛰기




Volumn 99, Issue 6, 2008, Pages 425-434

Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CADAVER; EDENTULOUSNESS; HUMAN; MALE; MANDIBLE; MAXILLA; PATHOLOGY; PERCUSSION; TOOTH ARCH; TOOTH IMPLANTATION; TOOTH PROSTHESIS; VIBRATION;

EID: 44349141722     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(08)60103-1     Document Type: Article
Times cited : (34)

References (24)
  • 1
    • 0027564377 scopus 로고
    • The effects of early occlusal laoding on one-stage titanium alloy implants in beagle dogs: a pilot study
    • Sagara M., Akagawa Y., Nikai H., and Tsuru H. The effects of early occlusal laoding on one-stage titanium alloy implants in beagle dogs: a pilot study. J Prosthet Dent 69 (1993) 281-288
    • (1993) J Prosthet Dent , vol.69 , pp. 281-288
    • Sagara, M.1    Akagawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 2
    • 0035748966 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study
    • Glauser R., Rée A., Lundgren A., Gottlow J., Hämmerle C., and Schärer P. Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res 3 (2001) 204-213
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 204-213
    • Glauser, R.1    Rée, A.2    Lundgren, A.3    Gottlow, J.4    Hämmerle, C.5    Schärer, P.6
  • 3
    • 33646502118 scopus 로고    scopus 로고
    • Significance of primary stability for osseointegration of dental implants
    • Lioubavina-Hack N., Lang N., and Karring T. Significance of primary stability for osseointegration of dental implants. Clin Oral Implants Res 17 (2006) 244-250
    • (2006) Clin Oral Implants Res , vol.17 , pp. 244-250
    • Lioubavina-Hack, N.1    Lang, N.2    Karring, T.3
  • 4
    • 0022465758 scopus 로고
    • Observations of the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar R., Lee J., and Maniatopoulos C. Observations of the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 208 (1986) 108-113
    • (1986) Clin Orthop Relat Res , vol.208 , pp. 108-113
    • Pilliar, R.1    Lee, J.2    Maniatopoulos, C.3
  • 5
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
    • Søballe K., Brockstedt-Rasmussen H., Hansen E., and Bünger C. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthop Scand 63 (1992) 128-140
    • (1992) Acta Orthop Scand , vol.63 , pp. 128-140
    • Søballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.3    Bünger, C.4
  • 6
    • 0018564497 scopus 로고
    • The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects
    • Brunski J., Moccia Jr. A., Pollack S., Korostoff E., and Trachtenberg D. The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects. J Dent Res 58 (1979) 1953-1969
    • (1979) J Dent Res , vol.58 , pp. 1953-1969
    • Brunski, J.1    Moccia Jr., A.2    Pollack, S.3    Korostoff, E.4    Trachtenberg, D.5
  • 7
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface
    • Brunski J. Biomechanical factors affecting the bone-dental implant interface. Clin Mater 10 (1992) 153-201
    • (1992) Clin Mater , vol.10 , pp. 153-201
    • Brunski, J.1
  • 8
    • 0033169706 scopus 로고    scopus 로고
    • Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs
    • Zubery Y., Bichacho N., Moses O., and Tal H. Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs. Int J Periodontics Restorative Dent 19 (1999) 343-353
    • (1999) Int J Periodontics Restorative Dent , vol.19 , pp. 343-353
    • Zubery, Y.1    Bichacho, N.2    Moses, O.3    Tal, H.4
  • 9
    • 0031108095 scopus 로고    scopus 로고
    • The use of the Periotest value as the initial success criteria of an implant: 8-year report
    • Aparicio C. The use of the Periotest value as the initial success criteria of an implant: 8-year report. Int J Periodontics Restorative Dent 17 (1997) 151-161
    • (1997) Int J Periodontics Restorative Dent , vol.17 , pp. 151-161
    • Aparicio, C.1
  • 10
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N., Alleyne D., and Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 7 (1996) 261-267
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 11
    • 0345304947 scopus 로고    scopus 로고
    • Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants
    • Nkenke E., Hahn M., Weinzierl K., Radespiel-Tröger M., Neukam F., and Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 14 (2003) 601-609
    • (2003) Clin Oral Implants Res , vol.14 , pp. 601-609
    • Nkenke, E.1    Hahn, M.2    Weinzierl, K.3    Radespiel-Tröger, M.4    Neukam, F.5    Engelke, K.6
  • 12
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
    • Lackmann S., Jäger B., Axmann D., Gomez-Roman G., Groten M., and Weber H. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 17 (2006) 75-79
    • (2006) Clin Oral Implants Res , vol.17 , pp. 75-79
    • Lackmann, S.1    Jäger, B.2    Axmann, D.3    Gomez-Roman, G.4    Groten, M.5    Weber, H.6
  • 13
    • 33847790159 scopus 로고    scopus 로고
    • Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial
    • Valderrama P., Oates T., Jones A., Simpson J., Schoolfield J., and Cochran D. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol 78 (2007) 262-272
    • (2007) J Periodontol , vol.78 , pp. 262-272
    • Valderrama, P.1    Oates, T.2    Jones, A.3    Simpson, J.4    Schoolfield, J.5    Cochran, D.6
  • 14
    • 25444498330 scopus 로고    scopus 로고
    • A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants
    • Balshi S., Allen F., Wolfinger G., and Balshi T. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants 20 (2005) 584-594
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 584-594
    • Balshi, S.1    Allen, F.2    Wolfinger, G.3    Balshi, T.4
  • 15
  • 16
    • 27544491195 scopus 로고    scopus 로고
    • Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study
    • Zix J., Kessler-Liechti, and Mericske-Stern R. Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 20 (2005) 747-752
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 747-752
    • Zix, J.1    Kessler-Liechti2    Mericske-Stern, R.3
  • 17
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study
    • Balleri P., Cozzzolino A., Ghelli L., Momicchioli G., and Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res 4 (2002) 128-132
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 18
    • 0025654203 scopus 로고
    • Periotest method as a measure of osseointegrated oral implant stability
    • Olivé J., and Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 5 (1990) 390-400
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 390-400
    • Olivé, J.1    Aparicio, C.2
  • 21
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 (1998) 491-501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 22
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith N., Shagaldi F., Alleyne D., Sennerby L., and Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 8 (1997) 234-243
    • (1997) Clin Oral Implants Res , vol.8 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5
  • 23
    • 37249059880 scopus 로고    scopus 로고
    • Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    • Al-Nawas B., Groetz K., Goetz H., Duschner H., and Wagner W. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model. Clin Oral Implants Res 19 (2008) 1-8
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1-8
    • Al-Nawas, B.1    Groetz, K.2    Goetz, H.3    Duschner, H.4    Wagner, W.5
  • 24
    • 37249055018 scopus 로고    scopus 로고
    • Relavance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments
    • Ito Y., Sato D., Yoneda S., Ito D., Kondo H., and Kasugai S. Relavance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments. Clin Oral Implants Res 19 (2008) 9-14
    • (2008) Clin Oral Implants Res , vol.19 , pp. 9-14
    • Ito, Y.1    Sato, D.2    Yoneda, S.3    Ito, D.4    Kondo, H.5    Kasugai, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.