메뉴 건너뛰기




Volumn 33, Issue 9, 2006, Pages 674-681

A numerical approach to resonance frequency analysis for the investigation of oral implant osseointegration

Author keywords

Finite element analysis; Oral implants; Osseointegration; Resonance frequency analysis; Testing devices

Indexed keywords

ARTICLE; BIOMECHANICS; BONE REGENERATION; COMPUTER SIMULATION; DENTAL CARE; FINITE ELEMENT ANALYSIS; HUMAN; MATHEMATICAL COMPUTING; METHODOLOGY; PHYSIOLOGY; THEORETICAL MODEL; TOOTH IMPLANTATION; VIBRATION;

EID: 33747064355     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2006.01610.x     Document Type: Article
Times cited : (14)

References (26)
  • 1
    • 0142079744 scopus 로고
    • The application of modal vibration analysis to study bone healing in vivo
    • Meredith N, Cawley P, Alleyne D. The application of modal vibration analysis to study bone healing in vivo. J Dent. 1994;73:793-799.
    • (1994) J Dent , vol.73 , pp. 793-799
    • Meredith, N.1    Cawley, P.2    Alleyne, D.3
  • 2
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:1-7.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 1-7
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 3
    • 0023435842 scopus 로고
    • Assessment of the interfacial rigidity of bone implants from vibrational signals
    • Kaneko T. Assessment of the interfacial rigidity of bone implants from vibrational signals. J Mater Sci. 1987;43:3495-3502.
    • (1987) J Mater Sci , vol.43 , pp. 3495-3502
    • Kaneko, T.1
  • 4
    • 0031148742 scopus 로고    scopus 로고
    • Impulse response of a dental implant in bone by numerical analysis
    • Williams KR, Williams ADC. Impulse response of a dental implant in bone by numerical analysis. Biomaterials. 1997;18:715-719.
    • (1997) Biomaterials , vol.18 , pp. 715-719
    • Williams, K.R.1    Williams, A.D.C.2
  • 5
    • 0025745033 scopus 로고
    • Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface
    • Kaneko T. Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface. Biomaterials. 1991;12:555-560.
    • (1991) Biomaterials , vol.12 , pp. 555-560
    • Kaneko, T.1
  • 6
    • 0030280566 scopus 로고    scopus 로고
    • A dynamic modal testing technique for noninvasive assessment of bone-dental implant surfaces
    • Elias JJ, Brunski JB, Scarton HA. A dynamic modal testing technique for noninvasive assessment of bone-dental implant surfaces. Int J Oral Maxillofac Implants. 1996;11:728-734.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 728-734
    • Elias, J.J.1    Brunski, J.B.2    Scarton, H.A.3
  • 7
    • 0025654203 scopus 로고
    • Periotest method as a measure of osseointegrated oral implant stability
    • Olive J, Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants. 1990;5:390-400.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 390-400
    • Olive, J.1    Aparicio, C.2
  • 8
    • 0026301746 scopus 로고
    • The Periotest method for determining implant success
    • Van Scotter DE, Wilson CJ. The Periotest method for determining implant success. J Oral Implantol. 1991;17:410-413.
    • (1991) J Oral Implantol , vol.17 , pp. 410-413
    • Van Scotter, D.E.1    Wilson, C.J.2
  • 9
    • 0029264675 scopus 로고
    • Damping characteristics of bonetoimplant interface; A clinical study with the Periotest® device
    • van Steenberghe D, Tricio J, Naert I, Nys M. Damping characteristics of bonetoimplant interface; A clinical study with the Periotest® device. Clin Oral Implants Res. 1995;6:31-39.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 31-39
    • Van Steenberghe, D.1    Tricio, J.2    Naert, I.3    Nys, M.4
  • 10
    • 33747045937 scopus 로고    scopus 로고
    • Calculation of the natural frequency of vibration of an orthopedic screw in cancellous bone of various orientations using the finite element method
    • Williams KR, Young FA. Calculation of the natural frequency of vibration of an orthopedic screw in cancellous bone of various orientations using the finite element method. J Mech Med Biol. 2002;2:67-79.
    • (2002) J Mech Med Biol , vol.2 , pp. 67-79
    • Williams, K.R.1    Young, F.A.2
  • 11
    • 0036481346 scopus 로고    scopus 로고
    • Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach
    • Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res. 2002;13:65-74.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 65-74
    • Huang, H.M.1    Lee, S.Y.2    Yeh, C.Y.3    Lin, C.T.4
  • 13
    • 0141816806 scopus 로고    scopus 로고
    • Factors influencing the resonance frequency of dental implants
    • Huang HM, Chui CL, Yeh CY, Lee SY. Factors influencing the resonance frequency of dental implants. J Oral Maxillofac Surg. 2003;61:1184-1188.
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 1184-1188
    • Huang, H.M.1    Chui, C.L.2    Yeh, C.Y.3    Lee, S.Y.4
  • 15
    • 0034308380 scopus 로고    scopus 로고
    • Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur
    • Wirtz DC, Schiffers N, Pandorf T, Radermacher K, Weichert D, Forst R. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J Biomech. 2000;33:1325-1330.
    • (2000) J Biomech , vol.33 , pp. 1325-1330
    • Wirtz, D.C.1    Schiffers, N.2    Pandorf, T.3    Radermacher, K.4    Weichert, D.5    Forst, R.6
  • 17
    • 0031240099 scopus 로고    scopus 로고
    • Investigation of the integration process of dental implants by means of a numerical analysis of dynamic response
    • Natali AN, Meroi EA, Williams KR. Investigation of the integration process of dental implants by means of a numerical analysis of dynamic response. Dent Mater. 1997;13:325-332.
    • (1997) Dent Mater , vol.13 , pp. 325-332
    • Natali, A.N.1    Meroi, E.A.2    Williams, K.R.3
  • 18
    • 27744606798 scopus 로고    scopus 로고
    • Numerical approach to dental biomechanics
    • Natali AN, ed. London: Taylor & Francis
    • Natali AN, Pavan PG. Numerical approach to dental biomechanics. In: Natali AN, ed. Dental Biomechanics. London: Taylor & Francis; 2003:211-239.
    • (2003) Dental Biomechanics , pp. 211-239
    • Natali, A.N.1    Pavan, P.G.2
  • 20
    • 0020711801 scopus 로고
    • Three dimensional distribution around a dental implant at different stages of interface development
    • Borchers L, Reichart P. Three dimensional distribution around a dental implant at different stages of interface development. J Dent Res. 1983;62:155-159.
    • (1983) J Dent Res , vol.62 , pp. 155-159
    • Borchers, L.1    Reichart, P.2
  • 21
    • 3242706723 scopus 로고    scopus 로고
    • Frequency spectrum of condylar movement in clinically normal subjects, using an amorphous sensor
    • Ioi H, Counts AL. Frequency spectrum of condylar movement in clinically normal subjects, using an amorphous sensor. J Oral Rehabil. 2004;31:634-639.
    • (2004) J Oral Rehabil , vol.31 , pp. 634-639
    • Ioi, H.1    Counts, A.L.2
  • 22
  • 24
    • 23944475039 scopus 로고    scopus 로고
    • Influence of cortical bone quality on stress distribution in bone around dental implant
    • Kitagawa T, Tanimoto Y, Nemoto K, Aida M. Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J. 2005;24:219-224.
    • (2005) Dent Mater J , vol.24 , pp. 219-224
    • Kitagawa, T.1    Tanimoto, Y.2    Nemoto, K.3    Aida, M.4
  • 25
    • 0033169238 scopus 로고    scopus 로고
    • Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study
    • Friberg B, Sennerby L, Linden B, Gröndahl K, Lekholm U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28:266-272.
    • (1999) Int J Oral Maxillofac Surg. , vol.28 , pp. 266-272
    • Friberg, B.1    Sennerby, L.2    Linden, B.3    Gröndahl, K.4    Lekholm, U.5
  • 26
    • 0035375058 scopus 로고    scopus 로고
    • Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load
    • Gotfredsen K, Berglundh T, Lindhe J. Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. Clin Oral Implants Res. 2001;12:196-201.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 196-201
    • Gotfredsen, K.1    Berglundh, T.2    Lindhe, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.