-
1
-
-
0029439911
-
Accuracy and Precision in the Radiographic Diagnosis of Clinical Instability in Brånemark Dental Implants
-
Sundén, S., Gröndahl, K., and Gröndahl, H.-G., 1995, "Accuracy and Precision in the Radiographic Diagnosis of Clinical Instability in Brånemark Dental Implants," Clin. Oral Implants Res., 28, pp. 220-226.
-
(1995)
Clin. Oral Implants Res
, vol.28
, pp. 220-226
-
-
Sundén, S.1
Gröndahl, K.2
Gröndahl, H.-G.3
-
2
-
-
0027639946
-
Reproducibility and Detection Threshold of Peri-Implant Diagnostics
-
van Steenberghe, D., and Quirynen, M., 1993, "Reproducibility and Detection Threshold of Peri-Implant Diagnostics," Adv. Dent. Res., 7, pp. 191-195.
-
(1993)
Adv. Dent. Res
, vol.7
, pp. 191-195
-
-
van Steenberghe, D.1
Quirynen, M.2
-
3
-
-
0003404715
-
On the Clinical Measurement of Implant Stability and Osseointegration,
-
Ph.D. thesis, Göteborg University
-
Meredith, N., 1997, "On the Clinical Measurement of Implant Stability and Osseointegration," Ph.D. thesis, Göteborg University.
-
(1997)
-
-
Meredith, N.1
-
4
-
-
0033197316
-
Measuring Abutment/ Implant Joint Integrity With the Periotest Instrument
-
Faulkner, G., Wolfaardt, J. F., and Chan, A., 1999, "Measuring Abutment/ Implant Joint Integrity With the Periotest Instrument," Int. J. Oral Maxillofac Implants, 14, pp. 681-688.
-
(1999)
Int. J. Oral Maxillofac Implants
, vol.14
, pp. 681-688
-
-
Faulkner, G.1
Wolfaardt, J.F.2
Chan, A.3
-
5
-
-
0031152150
-
Resonance Frequency Measurements of Implant Stability In Vivo
-
Meredith, N., Book, K., Friberg, B., Jemt, T., and Sennerby, L., 1997, "Resonance Frequency Measurements of Implant Stability In Vivo," Clin. Oral Implants Res., 8, pp. 226-233.
-
(1997)
Clin. Oral Implants Res
, vol.8
, pp. 226-233
-
-
Meredith, N.1
Book, K.2
Friberg, B.3
Jemt, T.4
Sennerby, L.5
-
6
-
-
0030224153
-
Quantitative Determination of the Stability of the Implant-Tissue Interface Using Resonance Frequency Analysis
-
Meredith, N., Alleyne, D., and Cawley, P., 1996, "Quantitative Determination of the Stability of the Implant-Tissue Interface Using Resonance Frequency Analysis," Clin. Oral Implants Res., 7, pp. 261-267.
-
(1996)
Clin. Oral Implants Res
, vol.7
, pp. 261-267
-
-
Meredith, N.1
Alleyne, D.2
Cawley, P.3
-
7
-
-
7944234226
-
Predicting Osseointegration by Means of Implant Primary Stability
-
Nedir, R., Bischof, M., Szmukler-Moncler, S., Bernard, J. P., and Samson, J., 2004, "Predicting Osseointegration by Means of Implant Primary Stability," Clin. Oral Implants Res., 15, pp. 520-528.
-
(2004)
Clin. Oral Implants Res
, vol.15
, pp. 520-528
-
-
Nedir, R.1
Bischof, M.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
8
-
-
7944232457
-
Implant Stability Measurement of Delayed and Immediately Loaded Implants During Healing
-
Bischof, M., Nedir, R., Szmukler-Moncler, S., Bernard, J. P., and Samson, J., 2004, "Implant Stability Measurement of Delayed and Immediately Loaded Implants During Healing," Clin. Oral Implants Res., 15, pp. 529-539.
-
(2004)
Clin. Oral Implants Res
, vol.15
, pp. 529-539
-
-
Bischof, M.1
Nedir, R.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
9
-
-
4644230057
-
Resonance Frequency Analysis of Implants Subjetted to Immediate or Early Function Occlusal Loading
-
Glauser, R., Sennerby, L., Meredith, N., Rée, A., Lundgren, A., Gottlow, J., and Hämmerle, C., 2004, "Resonance Frequency Analysis of Implants Subjetted to Immediate or Early Function Occlusal Loading," Clin. Oral Implants Res., 15, pp. 428-434.
-
(2004)
Clin. Oral Implants Res
, vol.15
, pp. 428-434
-
-
Glauser, R.1
Sennerby, L.2
Meredith, N.3
Rée, A.4
Lundgren, A.5
Gottlow, J.6
Hämmerle, C.7
-
10
-
-
0030280566
-
A Dynamic Modal Testing Technique for Noninvasive Assessment of Bone-Dental Implant Interfaces
-
Elias, J., Brunski, J., and Scarton, H., 1996, "A Dynamic Modal Testing Technique for Noninvasive Assessment of Bone-Dental Implant Interfaces," Int. J. Oral Maxillofac Implants, 11(6), pp. 728-734.
-
(1996)
Int. J. Oral Maxillofac Implants
, vol.11
, Issue.6
, pp. 728-734
-
-
Elias, J.1
Brunski, J.2
Scarton, H.3
-
11
-
-
0141497384
-
Early Detection of Implant Healing Process Using Resonance Frequency Analysis
-
Huang, H.-M., Chiu, C.-L., Yeh, C.-Y., Lin, C.-T., Lin, L.-H., and Lee, S.-Y., 2003, "Early Detection of Implant Healing Process Using Resonance Frequency Analysis," Clin. Oral Implants Res., 14, pp. 437-443.
-
(2003)
Clin. Oral Implants Res
, vol.14
, pp. 437-443
-
-
Huang, H.-M.1
Chiu, C.-L.2
Yeh, C.-Y.3
Lin, C.-T.4
Lin, L.-H.5
Lee, S.-Y.6
-
12
-
-
0025388816
-
Periotest - A Dynamic Procedure for the Diagnosis of the Human Periedontium
-
Lukas, D., and Schulte, W., 1990, "Periotest - A Dynamic Procedure for the Diagnosis of the Human Periedontium," Clin. Phys. Physiol. Meas., 11, pp. 65-75.
-
(1990)
Clin. Phys. Physiol. Meas
, vol.11
, pp. 65-75
-
-
Lukas, D.1
Schulte, W.2
-
13
-
-
0029264675
-
Damping Characteristics of Bone-to-Implant Interfaces: A Clinical Study With the Periotest Device
-
van Steenberghe, D., Tricio, J., Naert, I., and Nys, M., 1995, "Damping Characteristics of Bone-to-Implant Interfaces: A Clinical Study With the Periotest Device," Clin. Oral Implants Res., 6, pp. 31-39.
-
(1995)
Clin. Oral Implants Res
, vol.6
, pp. 31-39
-
-
van Steenberghe, D.1
Tricio, J.2
Naert, I.3
Nys, M.4
-
14
-
-
0025654203
-
The Periotest Method as a Measure of Osseointegrated Oral Implant Stability
-
Olivé, J., and Aparicio, C., 1990, "The Periotest Method as a Measure of Osseointegrated Oral Implant Stability," Int. J. Oral Maxillofac Implants, 5(4), pp. 390-400.
-
(1990)
Int. J. Oral Maxillofac Implants
, vol.5
, Issue.4
, pp. 390-400
-
-
Olivé, J.1
Aparicio, C.2
-
15
-
-
0029190399
-
The Relationship of Periotest Values, Biomaterials, and Torque to Failure in Adult Baboons
-
Carr, A. B., Papzoglon, E., and Larsen, P., 1995, "The Relationship of Periotest Values, Biomaterials, and Torque to Failure in Adult Baboons," Int. J. Prosthodont, 8, pp. 15-20.
-
(1995)
Int. J. Prosthodont
, vol.8
, pp. 15-20
-
-
Carr, A.B.1
Papzoglon, E.2
Larsen, P.3
-
16
-
-
33748309280
-
Validity and Clinical Significance of Biomechanical Testing of Implant/Bone Interface
-
Aparicio, C., Lang, N. P., and Rangert, B., 2006, "Validity and Clinical Significance of Biomechanical Testing of Implant/Bone Interface," Clin. Oral Implants Res., 17, pp. 2-7.
-
(2006)
Clin. Oral Implants Res
, vol.17
, pp. 2-7
-
-
Aparicio, C.1
Lang, N.P.2
Rangert, B.3
-
17
-
-
33748304331
-
Biomechanical Aspects of Oral Implants: Consensus Report of Working Group I
-
Hobkirk, J. A., and Wiskott, H. W. A., 2006, "Biomechanical Aspects of Oral Implants: Consensus Report of Working Group I," Clin. Oral Implants Res., 17, pp. 52-54.
-
(2006)
Clin. Oral Implants Res
, vol.17
, pp. 52-54
-
-
Hobkirk, J.A.1
Wiskott, H.W.A.2
-
18
-
-
0028239275
-
Relationship Between the Stiffness of the Dental Implant-Bone System and the Duration of the Implant-Tapping Rod Contact
-
Kaneko, T. M., 1994, "Relationship Between the Stiffness of the Dental Implant-Bone System and the Duration of the Implant-Tapping Rod Contact," Med. Eng. Phys., 16, pp. 310-315.
-
(1994)
Med. Eng. Phys
, vol.16
, pp. 310-315
-
-
Kaneko, T.M.1
-
19
-
-
0035404299
-
The Use and Abuse of the Periotest for 2-Piece Implant/Abutment Systems
-
Faulkner, G., Giannitsios, D., Lipsett, W., and Wolfaardt, J., 2001, "The Use and Abuse of the Periotest for 2-Piece Implant/Abutment Systems," Int. J. Oral Maxillofac Implants, 16(4), pp. 486-494.
-
(2001)
Int. J. Oral Maxillofac Implants
, vol.16
, Issue.4
, pp. 486-494
-
-
Faulkner, G.1
Giannitsios, D.2
Lipsett, W.3
Wolfaardt, J.4
-
20
-
-
33750372689
-
Simulation of Impact Test for Determining "Health" of Percutaneous Bone Anchored Implants
-
Jones, S., Faulkner, G., Rabound, D., Fyfe, K., and Wolfaardt, J., 2006, "Simulation of Impact Test for Determining "Health" of Percutaneous Bone Anchored Implants," ASME J. Biomech. Eng., 128, pp, 647-653.
-
(2006)
ASME J. Biomech. Eng
, vol.128
, pp. 647-653
-
-
Jones, S.1
Faulkner, G.2
Rabound, D.3
Fyfe, K.4
Wolfaardt, J.5
-
21
-
-
56349096635
-
-
Cowin, S., and Gno, X., 2001, Bone Mechanics Handbook, CRC, Boca Raton, FL, p. 10.9.
-
Cowin, S., and Gno, X., 2001, Bone Mechanics Handbook, CRC, Boca Raton, FL, p. 10.9.
-
-
-
-
22
-
-
0004199580
-
-
Prentice-Hall, Englewood Cliffs, NJ, pp
-
Oppenheim, A. V., Willsky, A. S., and Young, I. T., 1983, Signals and Systems, Prentice-Hall, Englewood Cliffs, NJ, pp. 413-420.
-
(1983)
Signals and Systems
, pp. 413-420
-
-
Oppenheim, A.V.1
Willsky, A.S.2
Young, I.T.3
-
23
-
-
0004169659
-
-
Prentice-Hall, Englewood Cliffs, NJ, pp
-
Thomson, W. T., 1981, Theory of Vibration with Applications, Prentice-Hall, Englewood Cliffs, NJ, pp. 192-201.
-
(1981)
Theory of Vibration with Applications
, pp. 192-201
-
-
Thomson, W.T.1
-
24
-
-
43149104310
-
Development and Modeling of an Impact Test to Determine the Bone-Implant, Interface Properties of Osseointegrated Implants,
-
PhD thesis, University of Alberta, Edmonton
-
Swain, R., 2006, "Development and Modeling of an Impact Test to Determine the Bone-Implant, Interface Properties of Osseointegrated Implants," PhD thesis, University of Alberta, Edmonton.
-
(2006)
-
-
Swain, R.1
-
25
-
-
33645084797
-
Resonance Frequency Analysis and Damping Capacity Assessment
-
Lachmaan, S., Jäger, B., Axmaan, D., Gomez-Roman, G., Groten, M., and Weber, H., 2006, "Resonance Frequency Analysis and Damping Capacity Assessment," Clin. Oral Implants Res., 17, pp. 75-79.
-
(2006)
Clin. Oral Implants Res
, vol.17
, pp. 75-79
-
-
Lachmaan, S.1
Jäger, B.2
Axmaan, D.3
Gomez-Roman, G.4
Groten, M.5
Weber, H.6
-
26
-
-
0033140443
-
In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface
-
Brunski, B., 1999, "In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface," Adv. Dent. Res., 13, pp. 99-119.
-
(1999)
Adv. Dent. Res
, vol.13
, pp. 99-119
-
-
Brunski, B.1
|