Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial

Author keywords

Damping capacity assessment; Implant stability; Osseointegration; Resonance frequency analysis

Indexed keywords

ARTICLE; BONE REGENERATION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DENTAL SURGERY; FEMALE; HUMAN; MALE; MIDDLE AGED; NONPARAMETRIC TEST; PERCUSSION; STATISTICAL MODEL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; ULTRASOUND; VIBRATION;

EID: 47249142397     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (99)

References (21)
  • 1
    • 0031152016 scopus 로고    scopus 로고
    • Buser D, Mericske-Stern R, Bernard J-P, et al. Long-term evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multi-center study with 2359 implants.Clin Oral Implants Res 1997;8:161-172.
    • Buser D, Mericske-Stern R, Bernard J-P, et al. Long-term evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multi-center study with 2359 implants.Clin Oral Implants Res 1997;8:161-172.
  • 2
    • 0036547410 scopus 로고    scopus 로고
    • Cochran DL, Buser D, ten Bruggenkate CM, et al.The use of reduced healing time on ITI implants with a sandblasted and etched (SLA) surface: Early results from clinical trials on ITI SLA implants.Clin Oral Implants Res 2002;13:144-153.
    • Cochran DL, Buser D, ten Bruggenkate CM, et al.The use of reduced healing time on ITI implants with a sandblasted and etched (SLA) surface: Early results from clinical trials on ITI SLA implants.Clin Oral Implants Res 2002;13:144-153.
  • 3
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical significance of biomechanical testing of implant/bone interface
    • Aparacio C, Lang NP, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin Oral Implants Res 2006;17(suppl 2):2-7.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.SUPPL. 2 , pp. 2-7
    • Aparacio, C.1    Lang, N.P.2    Rangert, B.3
  • 4
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 5
    • 0029439911 scopus 로고    scopus 로고
    • Sunden S, Grondahl K, Grondahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants.Clin Oral Implants Res 1995;6:220-226.
    • Sunden S, Grondahl K, Grondahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants.Clin Oral Implants Res 1995;6:220-226.
  • 6
    • 0035552535 scopus 로고    scopus 로고
    • Stability of implants and natural teeth as determined by the Periotest over 60 months of function
    • Winkler S, Morris HF, Spray JR. Stability of implants and natural teeth as determined by the Periotest over 60 months of function. J Oral Implantol 2001;27:198-203.
    • (2001) J Oral Implantol , vol.27 , pp. 198-203
    • Winkler, S.1    Morris, H.F.2    Spray, J.R.3
  • 7
    • 0034584296 scopus 로고    scopus 로고
    • Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants
    • Truhlar RS, Morris HF, Ochi S. Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants. Ann Periodontol 2000;5:42-55.
    • (2000) Ann Periodontol , vol.5 , pp. 42-55
    • Truhlar, R.S.1    Morris, H.F.2    Ochi, S.3
  • 8
    • 0032239028 scopus 로고    scopus 로고
    • Evaluation of the Periotest as a diagnostic tool for dental implants
    • Cranin AN, DeGrado J, Kaufman M, et al. Evaluation of the Periotest as a diagnostic tool for dental implants. J Oral Implantol 1998;24:139-146.
    • (1998) J Oral Implantol , vol.24 , pp. 139-146
    • Cranin, A.N.1    DeGrado, J.2    Kaufman, M.3
  • 9
    • 0031108095 scopus 로고    scopus 로고
    • The use of the Periotest value as the initial success criteria of an implant: 8-year report
    • Aparicio C.The use of the Periotest value as the initial success criteria of an implant: 8-year report. Int J Periodontics Restorative Dent 1997;17:150-161.
    • (1997) Int J Periodontics Restorative Dent , vol.17 , pp. 150-161
    • Aparicio, C.1
  • 10
    • 0029314564 scopus 로고    scopus 로고
    • Mericske-Stern R, Milani D, Mericske E, Olah A. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study.Clin Oral Implants Res 1995;6:73-82.
    • Mericske-Stern R, Milani D, Mericske E, Olah A. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study.Clin Oral Implants Res 1995;6:73-82.
  • 11
    • 33746366501 scopus 로고    scopus 로고
    • Early implant failure. Prognostic capacity of Periotest: Retrospective study of a large sample
    • Nogueral B, Muñoz R, Mesa F, de Dios Luna J, O'Valle F. Early implant failure. Prognostic capacity of Periotest: Retrospective study of a large sample. Clin Oral Implants Res 2006;17:459-464.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 459-464
    • Nogueral, B.1    Muñoz, R.2    Mesa, F.3    de Dios Luna, J.4    O'Valle, F.5
  • 12
    • 0032059195 scopus 로고    scopus 로고
    • Relationship between contact time measurements and PTV values when using the Periotest to measure Implant stability
    • Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure Implant stability. Int J Prosthodont 1998;11:269-275.
    • (1998) Int J Prosthodont , vol.11 , pp. 269-275
    • Meredith, N.1    Friberg, B.2    Sennerby, L.3    Aparicio, C.4
  • 13
    • 0030224153 scopus 로고    scopus 로고
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 19967:261-267.
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 19967:261-267.
  • 14
    • 7944234226 scopus 로고    scopus 로고
    • Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants
    • Nedir R, Bischof M, Szmukler-Moncler S, Bernard J-P, Samson J. Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants. Clin Oral Implants Res 2004;15:520-528.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 520-528
    • Nedir, R.1    Bischof, M.2    Szmukler-Moncler, S.3    Bernard, J.-P.4    Samson, J.5
  • 15
    • 0031152150 scopus 로고    scopus 로고
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A crosssectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.Clin Oral Implants Res 1997;8:226-233.
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A crosssectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.Clin Oral Implants Res 1997;8:226-233.
  • 16
    • 0025654203 scopus 로고
    • Periotest method as a measure of osseointegrated oral implant stability
    • Olive J, Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 1990;5:390-400.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 390-400
    • Olive, J.1    Aparicio, C.2
  • 17
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-267.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 19
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability anda method of comparison in the determination of primary dental implant stability
    • Lachmann S, Jager B, Axmann D, Gomez-Roman G, Graten M, Weber H. Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability anda method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 2006;17:75-79.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 75-79
    • Lachmann, S.1    Jager, B.2    Axmann, D.3    Gomez-Roman, G.4    Graten, M.5    Weber, H.6
  • 20
    • 33645051957 scopus 로고    scopus 로고
    • Lachmann S, Laval JY, Jager B, et al. Resonance frequency analysis and damping capacity assessment. Part 2: Periimplant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments.Clin Oral Implants Res 2006;17:80-84.
    • Lachmann S, Laval JY, Jager B, et al. Resonance frequency analysis and damping capacity assessment. Part 2: Periimplant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments.Clin Oral Implants Res 2006;17:80-84.
  • 21
    • 27544491195 scopus 로고    scopus 로고
    • Stability measurements of 1 -stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    • Zix J, Kessler-Liechti G, Mericske-Stern R. Stability measurements of 1 -stage implants in the maxilla by means of resonance frequency analysis: A pilot study. Int J Oral Maxillofac Implants 2005;20:747-752.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 747-752
    • Zix, J.1    Kessler-Liechti, G.2    Mericske-Stern, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.