메뉴 건너뛰기




Volumn 3, Issue 3, 2009, Pages 169-180

A wireless-implantable microsystem for continuous blood glucose monitoring

Author keywords

Amperometric sensor; Glucose; Implantable; Implantable microsystem; Microsystem; Potentiostat; Telemetry; Transponder chip; Wireless

Indexed keywords

IMPLANTABLE; IMPLANTABLE MICROSYSTEMS; POTENTIOSTAT; POTENTIOSTATS; TRANSPONDER CHIPS;

EID: 77955091787     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2009.2016844     Document Type: Article
Times cited : (221)

References (42)
  • 1
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and pro-gressionof long-term complications ininsulin-dependent diabetes mel-litus
    • Control And Complications Trial Research Group D.
    • Diabetes Control and Complications Trial Research Group, "The effect of intensive treatment of diabetes on the development and pro-gressionof long-term complications ininsulin-dependent diabetes mel-litus," New Engl. J. Med., vol.329, no.14, pp. 977-986, 1993.
    • (1993) New Engl. J. Med. , vol.329 , Issue.14 , pp. 977-986
  • 2
    • 0032511583 scopus 로고    scopus 로고
    • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)
    • UK Prospective Diabetes Study (UKPDS) Group Sep.
    • UK Prospective Diabetes Study (UKPDS) Group, "Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)," The Lancet, vol.352, no.9131, pp. 837-853, Sep. 1998.
    • (1998) The Lancet , vol.352 , Issue.9131 , pp. 837-853
  • 3
    • 0029147687 scopus 로고
    • Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin dependent diabetes mellitus: A randomized prospective six year study
    • Y. Ohkubo et al., "Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin dependent diabetes mellitus: A randomized prospective six year study," Diabetes Res. Clin. Pract., vol.28, no.2, pp. 103-117, 1995.
    • (1995) Diabetes Res. Clin. Pract. , vol.28 , Issue.2 , pp. 103-117
    • Ohkubo, Y.1
  • 4
    • 1842422039 scopus 로고    scopus 로고
    • The role of continuous glucose sensors in diabetes care
    • S. K. Garg, H. K. Hoff, and H. P. Chase, "The role of continuous glucose sensors in diabetes care," Endocrinol. Metab. Clin. N. Am., vol.33, pp. 163-173, 2004.
    • (2004) Endocrinol. Metab. Clin. N. Am. , vol.33 , pp. 163-173
    • Garg, S.K.1    Hoff, H.K.2    Chase, H.P.3
  • 5
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • D. C. Klonoff, "Continuous glucose monitoring: Roadmap for 21st century diabetes therapy," Diabetes Care, vol.28, no.5, pp. 1231-1239, 2005.
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 6
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • E. Kulcu, J. A. Tamada, G. Reach, R. O. Potts, and M. J. Lesho, "Physiological differences between interstitial glucose and blood glucose measured in human subjects," Diabetes Care, vol.26, no.8, pp. 2405-2409, 2003.
    • (2003) Diabetes Care , vol.26 , Issue.8 , pp. 2405-2409
    • Kulcu, E.1    Tamada, J.A.2    Reach, G.3    Potts, R.O.4    Lesho, M.J.5
  • 7
    • 0024041578 scopus 로고
    • A telemetry instrumentation system for chronically implanted glucose and oxygen sensors
    • Jul.
    • B. D. McKean and D. A. Gough, "A telemetry instrumentation system for chronically implanted glucose and oxygen sensors," IEEE Trans. Biomed. Eng., vol.35, no.7, pp. 526-532, Jul. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , Issue.7 , pp. 526-532
    • McKean, B.D.1    Gough, D.A.2
  • 8
    • 0028518589 scopus 로고
    • A telemetry instrumentation system for monitoring multiple subcutaneously implanted glucose sensors
    • Oct.
    • M. C. Shults, R. K. Rhodes, S. J. Updike, B. J. Gilligan, and W. N. Reining, "A telemetry instrumentation system for monitoring multiple subcutaneously implanted glucose sensors," IEEE Trans. Biomed. Eng., vol.41, no.10, pp. 937-942, Oct. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , Issue.10 , pp. 937-942
    • Shults, M.C.1    Rhodes, R.K.2    Updike, S.J.3    Gilligan, B.J.4    Reining, W.N.5
  • 9
    • 0028106630 scopus 로고
    • Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
    • B. J. Gilligan, M. C. Shults, R. K. Rhodes, and S. J. Updike, "Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model," Diabetes Care, vol.17, pp. 882-887, 1994.
    • (1994) Diabetes Care , vol.17 , pp. 882-887
    • Gilligan, B.J.1    Shults, M.C.2    Rhodes, R.K.3    Updike, S.J.4
  • 10
    • 0029053116 scopus 로고
    • Integrated im-plantable device for long-term glucose monitoring
    • E. Wilkins, P. Atanosov, and B. A. Muggenburg, "Integrated im-plantable device for long-term glucose monitoring," Biosensors Bioelectron., vol.10, pp. 485-494, 1995.
    • (1995) Biosensors Bioelectron. , vol.10 , pp. 485-494
    • Wilkins, E.1    Atanosov, P.2    Muggenburg, B.A.3
  • 11
    • 0030175963 scopus 로고    scopus 로고
    • Glucose monitoring: State of the art and future possibilities
    • E. Wilkins and P. Atanosov, "Glucose monitoring: State of the art and future possibilities," Med. Eng. Phys., vol.18, no.4, pp. 273-288, 1996.
    • (1996) Med. Eng. Phys. , vol.18 , Issue.4 , pp. 273-288
    • Wilkins, E.1    Atanosov, P.2
  • 13
    • 0033970025 scopus 로고    scopus 로고
    • A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
    • S. J. Updike, B. J. Gilligan, M. C. Shults, and R. K. Rhodes, "A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration," Diabetes Care, vol.23, no.2, pp. 208-214, 2000.
    • (2000) Diabetes Care , vol.23 , Issue.2 , pp. 208-214
    • Updike, S.J.1    Gilligan, B.J.2    Shults, M.C.3    Rhodes, R.K.4
  • 15
    • 13244255587 scopus 로고    scopus 로고
    • Towards a miniature implantable in-vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two-and three-electrode biosensors
    • Feb.
    • R. D. Beach, F. V. Kuster, and F. Moussy, "Towards a miniature implantable in-vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two-and three-electrode biosensors," IEEE Trans. Instrum. Meas., vol.54, no.1, pp. 61-72, Feb. 2005.
    • (2005) IEEE Trans. Instrum. Meas. , vol.54 , Issue.1 , pp. 61-72
    • Beach, R.D.1    Kuster, F.V.2    Moussy, F.3
  • 19
    • 0031673232 scopus 로고    scopus 로고
    • A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode
    • Jan.
    • T. Akin, K. Najafi, and R. M. Bradley, "A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode," IEEE J. Solid-State Circuits, vol.33, no.1, pp. 109-118, Jan. 1998.
    • (1998) IEEE J. Solid-State Circuits , vol.33 , Issue.1 , pp. 109-118
    • Akin, T.1    Najafi, K.2    Bradley, R.M.3
  • 20
    • 0037283377 scopus 로고    scopus 로고
    • Frequency characterization of blood glucose dynamics
    • D. A. Gough, K. Kreutz-Delgado, and T. M. Bremer, "Frequency characterization of blood glucose dynamics," Ann. Biomed. Eng., vol.31, no.1, pp. 91-97, 2003.
    • (2003) Ann. Biomed. Eng. , vol.31 , Issue.1 , pp. 91-97
    • Gough, D.A.1    Kreutz-Delgado, K.2    Bremer, T.M.3
  • 21
    • 0032675035 scopus 로고    scopus 로고
    • A CMOS bandgap reference circuit with sub-1-V operation
    • May
    • H. Banba et al., "A CMOS bandgap reference circuit with sub-1-V operation," IEEE J. Solid-State Circuits, vol.34, no.5, pp. 670-674, May 1999.
    • (1999) IEEE J. Solid-State Circuits , vol.34 , Issue.5 , pp. 670-674
    • Banba, H.1
  • 22
    • 8344259144 scopus 로고    scopus 로고
    • Fully integrated wideband high-current rectifiers for inductively powered devices
    • Nov.
    • M. Ghovanloo and K. Najafi, "Fully integrated wideband high-current rectifiers for inductively powered devices," IEEE J. Solid-State Circuits, vol.39, no.11, pp. 1976-1984, Nov. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.11 , pp. 1976-1984
    • Ghovanloo, M.1    Najafi, K.2
  • 23
    • 0035275354 scopus 로고    scopus 로고
    • Secure contactless smartcard ASIC with DPA protection
    • Mar.
    • P. Rakers, L. Connell, T. Collins, and D. Russell, "Secure contactless smartcard ASIC with DPA protection," IEEE J. Solid-State Circuits, vol.36, no.3, pp. 559-565, Mar. 2001.
    • (2001) IEEE J. Solid-State Circuits , vol.36 , Issue.3 , pp. 559-565
    • Rakers, P.1    Connell, L.2    Collins, T.3    Russell, D.4
  • 24
    • 0027961667 scopus 로고
    • An integrated CMOS potentio-stat for miniaturized electroanalytical instrumentation
    • R. Reay, S. Kounaves, and G. Kovacs, "An integrated CMOS potentio-stat for miniaturized electroanalytical instrumentation," in Proc. IEEE Int. Solid-State Circuits Conf., 1994, pp. 162-163.
    • (1994) Proc. IEEE Int. Solid-State Circuits Conf. , pp. 162-163
    • Reay, R.1    Kounaves, S.2    Kovacs, G.3
  • 26
    • 0038082121 scopus 로고    scopus 로고
    • Design of an integrated potentiostat circuit for CMOS bio sensor chips
    • Frey et al., "Design of an integrated potentiostat circuit for CMOS bio sensor chips," in Proc. IEEE Int. Symp. Circuits and Systems, 2003, vol.5, pp. 9-12.
    • (2003) Proc. IEEE Int. Symp. Circuits and Systems , vol.5 , pp. 9-12
    • Frey1
  • 27
    • 4344717490 scopus 로고    scopus 로고
    • VLSI potentiostat for amperometric measurements for electrolytic reactions
    • H. S. Narula and J. G. Harris, "VLSI potentiostat for amperometric measurements for electrolytic reactions," in Proc. IEEE Int. Symp. Circuits and Systems, 2004, vol.1, pp. 457-460.
    • (2004) Proc. IEEE Int. Symp. Circuits and Systems , vol.1 , pp. 457-460
    • Narula, H.S.1    Harris, J.G.2
  • 28
    • 4344671753 scopus 로고    scopus 로고
    • A low-voltage, chemical sensor interface for systems-on-chip: The fully differential poten-tiostat
    • S. Martin, F. Gebara, T. Strong, and R. Brown, "A low-voltage, chemical sensor interface for systems-on-chip: The fully differential poten-tiostat," in Proc. IEEE Int. Symp. Circuits and Systems, 2004, vol.4, pp. 892-895.
    • (2004) Proc. IEEE Int. Symp. Circuits and Systems , vol.4 , pp. 892-895
    • Martin, S.1    Gebara, F.2    Strong, T.3    Brown, R.4
  • 29
    • 29044444845 scopus 로고    scopus 로고
    • ACMOS-integrated microinstrument for trace detection of heavy metals
    • Dec.
    • S. Martin, F. Gebara, B. J. Larivee, and R. Brown,"ACMOS-integrated microinstrument for trace detection of heavy metals," IEEE J. Solid-State Circuits, vol.40, no.12, pp. 2777-2786, Dec. 2005.
    • (2005) IEEE J. Solid-state Circuits , vol.40 , Issue.12 , pp. 2777-2786
    • Martin, S.1    Gebara, F.2    Larivee, B.J.3    Brown, R.4
  • 30
    • 37849185036 scopus 로고    scopus 로고
    • 16-channel integrated potentiostat for distributed neuro-chemical sensing
    • Nov.
    • R. Genov, M. Stanacevic, M. Naware, G. Cauwenberghs, and N. V. Thakor, "16-channel integrated potentiostat for distributed neuro-chemical sensing," IEEE Trans. Circuits Syst. I, vol.53, no.11, pp. 2371-2376, Nov. 2006.
    • (2006) IEEE Trans. Circuits Syst. i , vol.53 , Issue.11 , pp. 2371-2376
    • Genov, R.1    Stanacevic, M.2    Naware, M.3    Cauwenberghs, G.4    Thakor, N.V.5
  • 32
    • 34247853514 scopus 로고    scopus 로고
    • VLSI potentiostat array with oversampling gain modulation for wide-range neurotransmitter sensing
    • Mar.
    • M. Stanacevic, K. Murari, A. Rege, G. Cauwenberghs, and N. V. Thakor, "VLSI potentiostat array with oversampling gain modulation for wide-range neurotransmitter sensing," IEEE Trans. Biomed. Circuits Syst., vol.1, no.1, pp. 63-72, Mar. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst. , vol.1 , Issue.1 , pp. 63-72
    • Stanacevic, M.1    Murari, K.2    Rege, A.3    Cauwenberghs, G.4    Thakor, N.V.5
  • 33
    • 67651160770 scopus 로고    scopus 로고
    • Current-mirror based potentiostats for three-electrode amperometric electrochemical sensors
    • to be published
    • M. M. Ahmadi and G. A. Jullien, "Current-mirror based potentiostats for three-electrode amperometric electrochemical sensors," IEEE Trans. Circuits Syst. I, 2009, to be published.
    • (2009) IEEE Trans. Circuits Syst. , vol.1
    • Ahmadi, M.M.1    Jullien, G.A.2
  • 39
    • 22444435567 scopus 로고    scopus 로고
    • Studies on surface wettability of poly (Dimethyl) siloxane (PDMS) and glass under oxygen-plasma treatment and correlation with bond strength
    • S. Bhattacharya, A. Datta, J. M. Berg, and S. Gangopadhyay, "Studies on surface wettability of poly (Dimethyl) siloxane (PDMS) and glass under oxygen-plasma treatment and correlation with bond strength," J. Microelectromechan. Syst., vol.14, pp. 590-597, 2005.
    • (2005) J. Microelectromechan. Syst. , vol.14 , pp. 590-597
    • Bhattacharya, S.1    Datta, A.2    Berg, J.M.3    Gangopadhyay, S.4
  • 41
    • 33845673743 scopus 로고    scopus 로고
    • Biocompatibility of an enzyme-based, electrochemical glucose sensor for short-term implantation in the subcutis
    • P. H. Kvist et al., "Biocompatibility of an enzyme-based, electrochemical glucose sensor for short-term implantation in the subcutis," Diabetes Technol Therapeut., vol.8, no.5, pp. 546-559, 2006.
    • (2006) Diabetes Technol Therapeut. , vol.8 , Issue.5 , pp. 546-559
    • Kvist, P.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.