-
1
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
-
DCCT Research Group: The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329:977-986, 1993
-
(1993)
N Engl J Med
, vol.329
, pp. 977-986
-
-
-
2
-
-
0032511583
-
Intensive blood-glucose control with sulphonylureas and insulin compared with conventional treatment and risk of complications in patients with type II diabetes
-
U.K. Prospective Diabetic Study Group: Intensive blood-glucose control with sulphonylureas and insulin compared with conventional treatment and risk of complications in patients with type II diabetes. Lancet 352:837-853, 1998
-
(1998)
Lancet
, vol.352
, pp. 837-853
-
-
-
3
-
-
0014191637
-
The enzyme electrode
-
Updike SJ, Hicks GP: The enzyme electrode. Nature 214:986-988, 1967
-
(1967)
Nature
, vol.214
, pp. 986-988
-
-
Updike, S.J.1
Hicks, G.P.2
-
4
-
-
0028106630
-
Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
-
Gilligan BJ, Shults MC, Rhodes RK, Updike SJ: Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care 17:882-887, 1994
-
(1994)
Diabetes Care
, vol.17
, pp. 882-887
-
-
Gilligan, B.J.1
Shults, M.C.2
Rhodes, R.K.3
Updike, S.J.4
-
5
-
-
0005181233
-
Principles of long-term fully implanted sensors with emphasis on radiotelemetric monitoring of blood glucose from inside a subcutaneous foreign body capsule (FBC)
-
Fraser DM, Ed. New York, Wiley
-
Updike SJ, Shults MC, Rhodes RK: Principles of long-term fully implanted sensors with emphasis on radiotelemetric monitoring of blood glucose from inside a subcutaneous foreign body capsule (FBC). In Biosensors in the Body. Fraser DM, Ed. New York, Wiley, 1997, p. 117-137
-
(1997)
Biosensors in the Body
, pp. 117-137
-
-
Updike, S.J.1
Shults, M.C.2
Rhodes, R.K.3
-
6
-
-
0031694505
-
Performance of subcutaneously implanted glucose sensors: A review
-
Gerritsen M, Jansen JA, Kros A, Nolte R, Lutterman JA: Performance of subcutaneously implanted glucose sensors: a review. J Invest Surg 11:163-174, 1998
-
(1998)
J Invest Surg
, vol.11
, pp. 163-174
-
-
Gerritsen, M.1
Jansen, J.A.2
Kros, A.3
Nolte, R.4
Lutterman, J.A.5
-
7
-
-
0028434961
-
Prediction of pocket-portable and implantable glucose enzyme electrode performance from combined species permeability and digital simulation analysis
-
Rhodes RK, Shults MC, Updike SJ: Prediction of pocket-portable and implantable glucose enzyme electrode performance from combined species permeability and digital simulation analysis. Anal Chem 66: 1520-1529, 1994
-
(1994)
Anal Chem
, vol.66
, pp. 1520-1529
-
-
Rhodes, R.K.1
Shults, M.C.2
Updike, S.J.3
-
8
-
-
0028413636
-
Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo
-
Updike SJ, Shults MC, Rhodes RK, Gilligan BJ, Luebow JO, von Heimburg D: Enzymatic glucose sensors: improved long-term performance in vitro and in vivo. Trans Am Soc Artificial Intern Organs 40:157-163, 1994
-
(1994)
Trans Am Soc Artificial Intern Organs
, vol.40
, pp. 157-163
-
-
Updike, S.J.1
Shults, M.C.2
Rhodes, R.K.3
Gilligan, B.J.4
Luebow, J.O.5
Von Heimburg, D.6
-
9
-
-
0024102233
-
Polyether polyurethanes: Biostable or not
-
Stokes KB: Polyether polyurethanes: biostable or not. J Biomater Appl 3:228-259, 1988
-
(1988)
J Biomater Appl
, vol.3
, pp. 228-259
-
-
Stokes, K.B.1
-
10
-
-
0028518589
-
A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors
-
Shults MC, Rhodes RK, Updike SJ, Gilligan BJ, Reining WN: A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors. IEEE Trans Biomed Eng 41:937-942, 1994
-
(1994)
IEEE Trans Biomed Eng
, vol.41
, pp. 937-942
-
-
Shults, M.C.1
Rhodes, R.K.2
Updike, S.J.3
Gilligan, B.J.4
Reining, W.N.5
-
11
-
-
0027753195
-
Dynamic concentration challenges for biosensor characterization
-
Baker DA, Gough DA: Dynamic concentration challenges for biosensor characterization. Biosens Bioelectron 8:433-441, 1993
-
(1993)
Biosens Bioelectron
, vol.8
, pp. 433-441
-
-
Baker, D.A.1
Gough, D.A.2
-
12
-
-
0023205574
-
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
-
Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl S: Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10:622-628, 1987
-
(1987)
Diabetes Care
, vol.10
, pp. 622-628
-
-
Clarke, W.L.1
Cox, D.2
Gonder-Frederick, L.A.3
Carter, W.4
Pohl, S.5
-
14
-
-
0024238982
-
Laboratory evaluation of new reusable blood glucose sensor
-
Updike SJ, Shults MC, Capelli CC, von Heimburg D, Rhodes RK, Joseph-Tipton N, Anderson B, Koch DD: Laboratory evaluation of new reusable blood glucose sensor. Diabetes Care 11:801-807, 1988
-
(1988)
Diabetes Care
, vol.11
, pp. 801-807
-
-
Updike, S.J.1
Shults, M.C.2
Capelli, C.C.3
Von Heimburg, D.4
Rhodes, R.K.5
Joseph-Tipton, N.6
Anderson, B.7
Koch, D.D.8
|