메뉴 건너뛰기




Volumn 54, Issue 1, 2005, Pages 61-72

Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors

Author keywords

Amperometric; Biomedical telemetry; Biosensors; Biotelemetry; Galvanostat; Glucose sensor; Implantable biomedical devices; Operational amplifiers (op amps); Potentiostat; Voltammetric

Indexed keywords

AMPEROMETRIC SENSORS; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ELECTRODES; EQUIVALENT CIRCUITS; GALVANOMETERS; OPERATIONAL AMPLIFIERS; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); PRINTED CIRCUIT BOARDS; TELEMETERING SYSTEMS; TRANSCEIVERS;

EID: 13244255587     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2004.839757     Document Type: Article
Times cited : (108)

References (20)
  • 1
    • 0027370108 scopus 로고
    • "The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin-dependent diabetes mellitus"
    • Diabetes Control and Complications Trial Research Group
    • Diabetes Control and Complications Trial Research Group, "The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin-dependent diabetes mellitus," N. Engl. J. Med, vol. 329, pp. 977-986, 1993.
    • (1993) N. Engl. J. Med. , vol.329 , pp. 977-986
  • 2
    • 0028533426 scopus 로고
    • "In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high temperature curing"
    • F. Moussy et al., "In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high temperature curing," Anal. Chem., vol. 66, pp. 3882-3888, 1994.
    • (1994) Anal. Chem. , vol.66 , pp. 3882-3888
    • Moussy, F.1
  • 3
    • 1542376482 scopus 로고
    • "Multilayered coatings of nation and poly(phenylenediamine) for the protection of glucose sensors in vivo"
    • D. J. Harrison et al., "Multilayered coatings of nation and poly(phenylenediamine) for the protection of glucose sensors in vivo," in Am. Chem. Soc. Symp. Ser. No 561, Interfacial Design and Chemical Sensing, 1994, pp. 255-263.
    • (1994) Am. Chem. Soc. Symp. Ser. No 561, Interfacial Design and Chemical Sensing , pp. 255-263
    • Harrison, D.J.1
  • 4
    • 0028183143 scopus 로고
    • "A miniaturized nafion-based glucose sensor: In vitro and in vivo evaluation in dogs"
    • F. Moussy, D. J. Harrison, and R. V. Rajotte, "A miniaturized nafion-based glucose sensor: in vitro and in vivo evaluation in dogs," Int. J. Artif. Organs, vol. 17, pp. 95-101, 1994.
    • (1994) Int. J. Artif. Organs , vol.17 , pp. 95-101
    • Moussy, F.1    Harrison, D.J.2    Rajotte, R.V.3
  • 5
    • 0032851128 scopus 로고    scopus 로고
    • "A ferric chloride pre-treatment to prevent calcification of nafion membrane used for implantable biosensors"
    • Jun. 30
    • T. I. Valdes and F. Moussy, "A ferric chloride pre-treatment to prevent calcification of nafion membrane used for implantable biosensors," Biosensors and Bioelectronics, vol. 14, no. 6, pp. 579-585, Jun. 30, 1999.
    • (1999) Biosensors and Bioelectronics , vol.14 , Issue.6 , pp. 579-585
    • Valdes, T.I.1    Moussy, F.2
  • 6
    • 0032007128 scopus 로고    scopus 로고
    • "In vitro and in vivo mineralization of nafion membrane used for implantable glucose biosensors"
    • R. C. Mercado and F. Moussy, "In vitro and in vivo mineralization of nafion membrane used for implantable glucose biosensors," Biosensors and Bioelectronics, vol. 13, no. 2, pp. 133-145, 1998.
    • (1998) Biosensors and Bioelectronics , vol.13 , Issue.2 , pp. 133-145
    • Mercado, R.C.1    Moussy, F.2
  • 7
    • 0030103391 scopus 로고    scopus 로고
    • "Integrated sensor-telemetry system for in vivo glucose monitoring"
    • Mar
    • J. Black et al., "Integrated sensor-telemetry system for in vivo glucose monitoring," Sens. Actuators B, vol. 31, no. 3, pp. 147-153, Mar. 1996.
    • (1996) Sens. Actuators B , vol.31 , Issue.3 , pp. 147-153
    • Black, J.1
  • 8
    • 0024041578 scopus 로고
    • "A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors"
    • Jul
    • B. D. McKean and D. Gough, "A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors," IEEE Trans. Biomed. Eng., vol. 35, no. 7, pp. 526-532, Jul. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , Issue.7 , pp. 526-532
    • McKean, B.D.1    Gough, D.2
  • 9
    • 0028518589 scopus 로고
    • "A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors"
    • Oct
    • M. C. Shults et al., "A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors," IEEE Trans. Biomed. Eng., vol. 41, no. 10, pp. 937-942, Oct. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , Issue.10 , pp. 937-942
    • Shults, M.C.1
  • 10
    • 0343424932 scopus 로고
    • "Needle-type glucose sensor for wearable artificial endocrine pancreas"
    • W. H. Ko et al. Ed. Mt. Kisko, New York: Futura
    • M. Schichiri et al., "Needle-type glucose sensor for wearable artificial endocrine pancreas," in Implantable Sensors for Closed-Loop Prosthetic Systems, W. H. Ko et al., Ed. Mt. Kisko, New York: Futura, 1985, pp. 197-209.
    • (1985) Implantable Sensors for Closed-Loop Prosthetic Systems , pp. 197-209
    • Schichiri, M.1
  • 11
    • 0030801288 scopus 로고    scopus 로고
    • "Implantation of a refillable glucose monotoring-telemetry device"
    • P. Atanasov et al., "Implantation of a refillable glucose monotoring-telemetry device,"Biosensors and Bioelectronics, vol. 12, no. 7, pp. 669-680, 1997.
    • (1997) Biosensors and Bioelectronics , vol.12 , Issue.7 , pp. 669-680
    • Atanasov, P.1
  • 12
    • 0030561045 scopus 로고    scopus 로고
    • "Short-term canine implantation of a glucose monitoring-telemetry device"
    • Dec
    • P. Atanasov et al., "Short-term canine implantation of a glucose monitoring-telemetry device," Med. Eng. Phys., vol. 18, no. 8, pp. 632-640, Dec. 1996.
    • (1996) Med. Eng. Phys. , vol.18 , Issue.8 , pp. 632-640
    • Atanasov, P.1
  • 13
    • 1842533496 scopus 로고    scopus 로고
    • "A telemetry-instrumentation system for long-term implantable glucose and oxygen sensors"
    • C. Salehi et al., "A telemetry-instrumentation system for long-term implantable glucose and oxygen sensors," Anal. Lett., vol. 29, no. 13, pp. 2289-2308, 1996.
    • (1996) Anal. Lett. , vol.29 , Issue.13 , pp. 2289-2308
    • Salehi, C.1
  • 14
    • 0029053116 scopus 로고
    • "Integrated implantable device for long term glucose monitoring"
    • E. Wilkins, P. Atanasov, and B. A. Muggenburg, "Integrated implantable device for long term glucose monitoring," Biosensors and Bioelectronics, vol. 10, no. 5, pp. 485-494, 1995.
    • (1995) Biosensors and Bioelectronics , vol.10 , Issue.5 , pp. 485-494
    • Wilkins, E.1    Atanasov, P.2    Muggenburg, B.A.3
  • 16
    • 0001620673 scopus 로고    scopus 로고
    • "Electrical communication between electrodes and enzymes mediated by redox hydrogels"
    • E. J. Calvo and R. Etchenique, "Electrical communication between electrodes and enzymes mediated by redox hydrogels," Anal. Chem., vol. 68, no. 23, pp. 4186-4193, 1996.
    • (1996) Anal. Chem. , vol.68 , Issue.23 , pp. 4186-4193
    • Calvo, E.J.1    Etchenique, R.2
  • 17
    • 2342481163 scopus 로고    scopus 로고
    • "Electrochemical techniques for the characterization of redox polymers"
    • A. W. Bott, "Electrochemical techniques for the characterization of redox polymers," Current Separations, vol. 19, no. 3, pp. 71-75, 2001.
    • (2001) Current Separations , vol.19 , Issue.3 , pp. 71-75
    • Bott, A.W.1
  • 18
    • 0035902331 scopus 로고    scopus 로고
    • "Electrochemical characterization of self-assembled alkylsiloxane monolayers on Indium-Tin Oxide (ITO) semiconductor electrodes"
    • H. Hillebrandt and M. Tanaka, "Electrochemical characterization of self-assembled alkylsiloxane monolayers on Indium-Tin Oxide (ITO) semiconductor electrodes," J. Phys. Chem. B, vol. 105, no. 19, pp. 4260-4276, 2001.
    • (2001) J. Phys. Chem. B , vol.105 , Issue.19 , pp. 4260-4276
    • Hillebrandt, H.1    Tanaka, M.2
  • 19
    • 0035362061 scopus 로고    scopus 로고
    • "Totally implantable real-time in vivo video telemetry monitoring system for implant biocompatibility studies"
    • Jun
    • R. D. Beach and F. Moussy, "Totally implantable real-time in vivo video telemetry monitoring system for implant biocompatibility studies," IEEE Trans. Instrum. Meas., vol. 50, no. 3, pp. 716-723, Jun. 2001.
    • (2001) IEEE Trans. Instrum. Meas. , vol.50 , Issue.3 , pp. 716-723
    • Beach, R.D.1    Moussy, F.2
  • 20
    • 13244300488 scopus 로고    scopus 로고
    • "Unpublished Personal Communications Regarding Implantable Author (PCD) Telemetry Device Testing in Rhesus Monkeys. Walter Reed Army Institute of Research"
    • unpublished
    • D. Redmond, "Unpublished Personal Communications Regarding Implantable Author (PCD) Telemetry Device Testing in Rhesus Monkeys. Walter Reed Army Institute of Research," unpublished, 1998.
    • (1998)
    • Redmond, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.