Volumn 48, Issue 3, 2010, Pages 629-640

Quality Assurance and Dosimetry in Bone Densitometry

Author keywords

Densitometry; Quality assurance; Quality control; Radiation dose; Skeletal status

Indexed keywords

BONE DENSITOMETRY; CLINICAL PRACTICE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DOSIMETRY; DUAL ENERGY X RAY ABSORPTIOMETRY; HEALTH CARE QUALITY; HUMAN; MEDICAL EDUCATION; MULTIDETECTOR COMPUTED TOMOGRAPHY; OCCUPATIONAL EXPOSURE; OCCUPATIONAL SAFETY; OSTEOPOROSIS; PATIENT SAFETY; PRIORITY JOURNAL; QUALITY CONTROL; QUANTITATIVE DIAGNOSIS; RADIATION DOSE; RADIATION EQUIPMENT; RADIATION EXPOSURE; RADIATION PROTECTION; REPRODUCIBILITY; REVIEW; SENSITIVITY AND SPECIFICITY; STANDARDIZATION; BONE DENSITY; METHODOLOGY; PHOTON ABSORPTIOMETRY; RADIOGRAPHY; STANDARD;

EID: 77954157568     PISSN: 00338389     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rcl.2010.02.011     Document Type: Review
Times cited : (10)

References (61)
  • 2
    • 0025058121 scopus 로고
    • Dual-energy radiographic absorptiometry of the lumbar spine: clinical experience with two different systems
    • Gundry C.R., Miller C.W., Ramos E., et al. Dual-energy radiographic absorptiometry of the lumbar spine: clinical experience with two different systems. Radiology 1990, 174:539-541.
    • (1990) Radiology , vol.174 , pp. 539-541
    • Gundry, C.R.1    Miller, C.W.2    Ramos, E.3
  • 3
    • 0026675710 scopus 로고
    • Assessment of spinal and femoral bone density by dual X-ray absorptiometry: comparison of Lunar and Hologic instruments
    • Pocock N.A., Sambrook P.N., Nguyen T., et al. Assessment of spinal and femoral bone density by dual X-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res 1992, 7:1081-1084.
    • (1992) J Bone Miner Res , vol.7 , pp. 1081-1084
    • Pocock, N.A.1    Sambrook, P.N.2    Nguyen, T.3
  • 4
    • 17144463967 scopus 로고
    • Standardization of measurements for assessing BMD by DXA
    • [letter to the editor]
    • Steiger P. Standardization of measurements for assessing BMD by DXA. Calcif Tissue Int 1995, 57:469. [letter to the editor].
    • (1995) Calcif Tissue Int , vol.57 , pp. 469
    • Steiger, P.1
  • 5
    • 0031201603 scopus 로고    scopus 로고
    • Standardization of femur BMD
    • [letter to the editor]
    • Hanson J. Standardization of femur BMD. J Bone Miner Res 1997, 12:1316-1317. [letter to the editor].
    • (1997) J Bone Miner Res , vol.12 , pp. 1316-1317
    • Hanson, J.1
  • 6
    • 0029080928 scopus 로고
    • The European Spine Phantom-a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT
    • Kalender W.A., Felsenberg D., Genant H.K., et al. The European Spine Phantom-a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. Eur J Radiol 1995, 20:83-92.
    • (1995) Eur J Radiol , vol.20 , pp. 83-92
    • Kalender, W.A.1    Felsenberg, D.2    Genant, H.K.3
  • 7
    • 69849098328 scopus 로고    scopus 로고
    • Quantitative computed tomography
    • Adams J.E. Quantitative computed tomography. Eur J Radiol 2009, 71:415-424.
    • (2009) Eur J Radiol , vol.71 , pp. 415-424
    • Adams, J.E.1
  • 8
    • 69849108806 scopus 로고    scopus 로고
    • Dual-energy X-ray absorptiometry
    • Berlin, Heidelberg, Springer, New York, S. Grampp (Ed.)
    • Adams J.E. Dual-energy X-ray absorptiometry. Radiology of osteoporosis 2008, 105-124. Berlin, Heidelberg, Springer, New York. 2nd revised edition. S. Grampp (Ed.).
    • (2008) Radiology of osteoporosis , pp. 105-124
    • Adams, J.E.1
  • 9
    • 69849101242 scopus 로고    scopus 로고
    • The clinical role of dual energy X-ray absorptiometry
    • Blake G., Fogelman I. The clinical role of dual energy X-ray absorptiometry. Eur J Radiol 2009, 71:406-414.
    • (2009) Eur J Radiol , vol.71 , pp. 406-414
    • Blake, G.1    Fogelman, I.2
  • 11
    • 61749101928 scopus 로고    scopus 로고
    • Reanalysis precision of 3D quantitative computed tomography (QCT) of the spine
    • Engelke K., Mastmeyer A., Bousson V., et al. Reanalysis precision of 3D quantitative computed tomography (QCT) of the spine. Bone 2009, 44:566-572.
    • (2009) Bone , vol.44 , pp. 566-572
    • Engelke, K.1    Mastmeyer, A.2    Bousson, V.3
  • 12
    • 0023479450 scopus 로고
    • Total bone calcium in normal women: effect of age and menopause status
    • Gallagher J.C., Goldgar D., Moy A. Total bone calcium in normal women: effect of age and menopause status. J Bone Miner Res 1987, 2:491-495.
    • (1987) J Bone Miner Res , vol.2 , pp. 491-495
    • Gallagher, J.C.1    Goldgar, D.2    Moy, A.3
  • 13
    • 57049178940 scopus 로고    scopus 로고
    • International Society for Clinical Densitometry 2007 adult and pediatric official positions
    • Lewiecki E., Gordon C., Baim S., et al. International Society for Clinical Densitometry 2007 adult and pediatric official positions. Bone 2008, 43:1115-1121.
    • (2008) Bone , vol.43 , pp. 1115-1121
    • Lewiecki, E.1    Gordon, C.2    Baim, S.3
  • 14
    • 34248641980 scopus 로고    scopus 로고
    • An update on the assessment of osteoporosis using radiologic techniques
    • Damilakis J., Maris T., Karantanas A. An update on the assessment of osteoporosis using radiologic techniques. Eur Radiol 2007, 17:1591-1602.
    • (2007) Eur Radiol , vol.17 , pp. 1591-1602
    • Damilakis, J.1    Maris, T.2    Karantanas, A.3
  • 15
    • 34250167898 scopus 로고    scopus 로고
    • Hip fracture discrimination by the Achilles insight QUS imaging device
    • Damilakis J., Papadokostakis G., Perisinakis K., et al. Hip fracture discrimination by the Achilles insight QUS imaging device. Eur J Radiol 2007, 63:59-62.
    • (2007) Eur J Radiol , vol.63 , pp. 59-62
    • Damilakis, J.1    Papadokostakis, G.2    Perisinakis, K.3
  • 16
    • 69849109989 scopus 로고    scopus 로고
    • Quantitative ultrasound in the assessment of osteoporosis
    • Guglielmi G., de Terlizzi F. Quantitative ultrasound in the assessment of osteoporosis. Eur J Radiol 2009, 71:425-431.
    • (2009) Eur J Radiol , vol.71 , pp. 425-431
    • Guglielmi, G.1    de Terlizzi, F.2
  • 17
    • 46149113299 scopus 로고    scopus 로고
    • In vivo measurements of ultrasound transmission through the human proximal femur
    • Barkmann R., Laugier P., Moser U., et al. In vivo measurements of ultrasound transmission through the human proximal femur. Ultrasound Med Biol 2008, 34:1186-1190.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 1186-1190
    • Barkmann, R.1    Laugier, P.2    Moser, U.3
  • 18
    • 0347926183 scopus 로고    scopus 로고
    • Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device
    • Damilakis J., Papadokostakis G., Vrahoriti H., et al. Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device. Invest Radiol 2003, 38:207-211.
    • (2003) Invest Radiol , vol.38 , pp. 207-211
    • Damilakis, J.1    Papadokostakis, G.2    Vrahoriti, H.3
  • 19
    • 67650891829 scopus 로고    scopus 로고
    • Quantitative ultrasound in the assessment of skeletal status
    • Guglielmi G., Adams J., Link T.M. Quantitative ultrasound in the assessment of skeletal status. Eur Radiol 2009, 19:1837-1848.
    • (2009) Eur Radiol , vol.19 , pp. 1837-1848
    • Guglielmi, G.1    Adams, J.2    Link, T.M.3
  • 20
    • 0013501873 scopus 로고    scopus 로고
    • Standardized coefficient of variation for dual X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and markers of boné turnover
    • [abstract]
    • Machado A., Hannon R., Henry Y., et al. Standardized coefficient of variation for dual X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and markers of boné turnover. J Bone Miner Res 1997, 12(Suppl 1):S258. [abstract].
    • (1997) J Bone Miner Res , vol.12 , Issue.1 SUPPL.
    • Machado, A.1    Hannon, R.2    Henry, Y.3
  • 21
    • 0002924857 scopus 로고    scopus 로고
    • Statistical tools in quantitative ultrasound applications
    • Dunitz, London, C. Njeh, D. Hans, T. Fuerst (Eds.)
    • Lu Y., Gluer C.C. Statistical tools in quantitative ultrasound applications. Quantitative ultrasound. Assessment of osteoporosis and bone status 1999, 77-100. Dunitz, London. C. Njeh, D. Hans, T. Fuerst (Eds.).
    • (1999) Quantitative ultrasound. Assessment of osteoporosis and bone status , pp. 77-100
    • Lu, Y.1    Gluer, C.C.2
  • 22
    • 0028846896 scopus 로고
    • Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for pediatric studies
    • Koo W.W., Walters J., Bush A.J., et al. Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for pediatric studies. J Bone Miner Res 1995, 10:1998-2004.
    • (1995) J Bone Miner Res , vol.10 , pp. 1998-2004
    • Koo, W.W.1    Walters, J.2    Bush, A.J.3
  • 23
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103
    • The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007, 37:1-332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 24
    • 33846529471 scopus 로고    scopus 로고
    • National survey of doses in the UK: 2003
    • Shrimpton P.C., Hillier M.C., Lewis M.A., et al. National survey of doses in the UK: 2003. Br J Radiol 2006, 79:968-980.
    • (2006) Br J Radiol , vol.79 , pp. 968-980
    • Shrimpton, P.C.1    Hillier, M.C.2    Lewis, M.A.3
  • 25
    • 40049109570 scopus 로고    scopus 로고
    • International Commission on Radiation Protection Managing patient dose in multi-detector computed tomography (MDCT). ICRP publication 102
    • Valentin J., International Commission on Radiation Protection Managing patient dose in multi-detector computed tomography (MDCT). ICRP publication 102. Ann ICRP 2007, 37:1-79.
    • (2007) Ann ICRP , vol.37 , pp. 1-79
    • Valentin, J.1
  • 26
    • 0031055416 scopus 로고    scopus 로고
    • Absorbed dose measurements in dual energy X-ray absorptiometry (DXA)
    • Bezakova E., Collins P.J., Beddoe A.H. Absorbed dose measurements in dual energy X-ray absorptiometry (DXA). Br J Radiol 1997, 70:172-179.
    • (1997) Br J Radiol , vol.70 , pp. 172-179
    • Bezakova, E.1    Collins, P.J.2    Beddoe, A.H.3
  • 28
    • 0027196216 scopus 로고
    • Regional and total body bone mineral content, bone mineral density and total body tissue composition in children 8-16 years of age
    • Faulkner R.A., Bailey D.A., Drinkwater D.T., et al. Regional and total body bone mineral content, bone mineral density and total body tissue composition in children 8-16 years of age. Calcif Tissue Int 1993, 53:7-12.
    • (1993) Calcif Tissue Int , vol.53 , pp. 7-12
    • Faulkner, R.A.1    Bailey, D.A.2    Drinkwater, D.T.3
  • 29
    • 0029884750 scopus 로고    scopus 로고
    • Patient doses in bone mineral densitometry
    • Huda W., Morin R.L. Patient doses in bone mineral densitometry. Br J Radiol 1996, 69:422-425.
    • (1996) Br J Radiol , vol.69 , pp. 422-425
    • Huda, W.1    Morin, R.L.2
  • 30
    • 0032922121 scopus 로고    scopus 로고
    • Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine
    • Cawte S.A., Pearson D., Green D.J., et al. Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine. Br J Radiol 1999, 72:354-362.
    • (1999) Br J Radiol , vol.72 , pp. 354-362
    • Cawte, S.A.1    Pearson, D.2    Green, D.J.3
  • 31
    • 0030878140 scopus 로고    scopus 로고
    • Radiation dose and in vitro precision in bone mineral density measurement using dual X-ray absorptiometry
    • Njeh C.F., Samat S.B., Nightingale A., et al. Radiation dose and in vitro precision in bone mineral density measurement using dual X-ray absorptiometry. Br J Radiol 1997, 70:719-727.
    • (1997) Br J Radiol , vol.70 , pp. 719-727
    • Njeh, C.F.1    Samat, S.B.2    Nightingale, A.3
  • 32
    • 0026607069 scopus 로고
    • Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography
    • Kalender W.A. Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography. Osteoporos Int 1992, 2:82-87.
    • (1992) Osteoporos Int , vol.2 , pp. 82-87
    • Kalender, W.A.1
  • 33
    • 0025174095 scopus 로고
    • Effect dose equivalent in dual X-ray absorptiometry
    • [letter]
    • Pye D.W., Hannan W.J., Hesp R. Effect dose equivalent in dual X-ray absorptiometry. Br J Radiol 1990, 63:746. [letter].
    • (1990) Br J Radiol , vol.63 , pp. 746
    • Pye, D.W.1    Hannan, W.J.2    Hesp, R.3
  • 34
    • 0031932797 scopus 로고    scopus 로고
    • An assessment of the radiation dose to patients and staff from a Lunar Expert-XL fan beam densitometer
    • Steel S.A., Baker A.J., Saunderson J.R. An assessment of the radiation dose to patients and staff from a Lunar Expert-XL fan beam densitometer. Physiol Meas 1998, 19:17-26.
    • (1998) Physiol Meas , vol.19 , pp. 17-26
    • Steel, S.A.1    Baker, A.J.2    Saunderson, J.R.3
  • 35
    • 33749348458 scopus 로고    scopus 로고
    • Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations
    • Blake G., Naeem M., Boutros M. Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations. Bone 2006, 38:935-942.
    • (2006) Bone , vol.38 , pp. 935-942
    • Blake, G.1    Naeem, M.2    Boutros, M.3
  • 36
    • 55249086075 scopus 로고    scopus 로고
    • QA/Acceptance testing of DEXA X-ray systems used in bone mineral densitometry
    • Larkin A., Sheahan N., O'Connor U., et al. QA/Acceptance testing of DEXA X-ray systems used in bone mineral densitometry. Radiat Prot Dosimetry 2008, 129:279-283.
    • (2008) Radiat Prot Dosimetry , vol.129 , pp. 279-283
    • Larkin, A.1    Sheahan, N.2    O'Connor, U.3
  • 37
    • 28144439205 scopus 로고    scopus 로고
    • Effective dose of dual-energy X-ray absorptiometry scans in children as a function of age
    • Thomas S.R., Kalkwarf H.J., Buckley D.D., et al. Effective dose of dual-energy X-ray absorptiometry scans in children as a function of age. J Clin Densitom 2005, 8:415-422.
    • (2005) J Clin Densitom , vol.8 , pp. 415-422
    • Thomas, S.R.1    Kalkwarf, H.J.2    Buckley, D.D.3
  • 38
    • 0036714196 scopus 로고    scopus 로고
    • Embryo/fetus radiation dose and risk from dual X-ray absorptiometry examinations
    • Damilakis J., Perisinakis K., Vrahoriti H., et al. Embryo/fetus radiation dose and risk from dual X-ray absorptiometry examinations. Osteoporos Int 2002, 13:716-722.
    • (2002) Osteoporos Int , vol.13 , pp. 716-722
    • Damilakis, J.1    Perisinakis, K.2    Vrahoriti, H.3
  • 39
    • 42649115770 scopus 로고    scopus 로고
    • Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD Official Positions
    • Engelke K., Adams J.E., Armbrecht G., et al. Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD Official Positions. J Clin Densitom 2008, 11:123-162.
    • (2008) J Clin Densitom , vol.11 , pp. 123-162
    • Engelke, K.1    Adams, J.E.2    Armbrecht, G.3
  • 40
    • 68949209983 scopus 로고    scopus 로고
    • Comparison of QCT-derived and DXA-derived areal bone mineral density and T scores
    • Khoo B.C., Brown K., Cann C., et al. Comparison of QCT-derived and DXA-derived areal bone mineral density and T scores. Osteoporos Int 2009, 20:1539-1545.
    • (2009) Osteoporos Int , vol.20 , pp. 1539-1545
    • Khoo, B.C.1    Brown, K.2    Cann, C.3
  • 41
    • 67349234998 scopus 로고    scopus 로고
    • Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA)
    • Engelke C., Libanati C., Liu Y., et al. Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA). Bone 2009, 45:110-118.
    • (2009) Bone , vol.45 , pp. 110-118
    • Engelke, C.1    Libanati, C.2    Liu, Y.3
  • 42
    • 0036479887 scopus 로고    scopus 로고
    • Bone structure of the distal radius and the calcaneus vs BMD of the spine and proximal femur in the prediction of osteoporotic spine fractures
    • Link T.M., Vieth V., Matheis J., et al. Bone structure of the distal radius and the calcaneus vs BMD of the spine and proximal femur in the prediction of osteoporotic spine fractures. Eur Radiol 2002, 12:401-408.
    • (2002) Eur Radiol , vol.12 , pp. 401-408
    • Link, T.M.1    Vieth, V.2    Matheis, J.3
  • 43
    • 33645366441 scopus 로고    scopus 로고
    • Importance of individual rods and plates in the assessment of bone quality and their contribution to bone stiffness
    • Stauber M., Rapillard L., van Lenthe G.H., et al. Importance of individual rods and plates in the assessment of bone quality and their contribution to bone stiffness. J Bone Miner Res 2006, 21:586-595.
    • (2006) J Bone Miner Res , vol.21 , pp. 586-595
    • Stauber, M.1    Rapillard, L.2    van Lenthe, G.H.3
  • 44
    • 77951245852 scopus 로고    scopus 로고
    • Assessment of trabecular bone structure using MDCT: comparison of 64- and 320-slice CT using HR-pQCT as the reference standard
    • Issever A., Link T., Kentenich M., et al. Assessment of trabecular bone structure using MDCT: comparison of 64- and 320-slice CT using HR-pQCT as the reference standard. Eur Radiol 2010, 20:458-468.
    • (2010) Eur Radiol , vol.20 , pp. 458-468
    • Issever, A.1    Link, T.2    Kentenich, M.3
  • 45
    • 57449095145 scopus 로고    scopus 로고
    • High resolution computed tomography of the vertebrae yields accurate information on trabecular distances if processed by 3D fuzzy segmentation approaches
    • Krebs A., Graeff C., Frieling I., et al. High resolution computed tomography of the vertebrae yields accurate information on trabecular distances if processed by 3D fuzzy segmentation approaches. Bone 2009, 44:145-152.
    • (2009) Bone , vol.44 , pp. 145-152
    • Krebs, A.1    Graeff, C.2    Frieling, I.3
  • 46
    • 25444529444 scopus 로고    scopus 로고
    • Multidetector row CT imaging of vertebral microstructure for evaluation of fracture risk
    • Ito M., Ikeda K., Nishiguchi M., et al. Multidetector row CT imaging of vertebral microstructure for evaluation of fracture risk. J Bone Miner Res 2005, 20:1828-1836.
    • (2005) J Bone Miner Res , vol.20 , pp. 1828-1836
    • Ito, M.1    Ikeda, K.2    Nishiguchi, M.3
  • 47
    • 36049045483 scopus 로고    scopus 로고
    • Monitoring teriparatide-associated changes in vertebral microstructure by high-resolution CT in vivo: results from the EUROFORS study
    • Graeff C., Timm W., Nickelsen T.N., et al. Monitoring teriparatide-associated changes in vertebral microstructure by high-resolution CT in vivo: results from the EUROFORS study. J Bone Miner Res 2007, 22:1426-1433.
    • (2007) J Bone Miner Res , vol.22 , pp. 1426-1433
    • Graeff, C.1    Timm, W.2    Nickelsen, T.N.3
  • 48
    • 21144440833 scopus 로고    scopus 로고
    • The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
    • Tzedakis A., Damilakis J., Perisinakis K., et al. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations. Med Phys 2005, 32:1621-1629.
    • (2005) Med Phys , vol.32 , pp. 1621-1629
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3
  • 49
    • 67650067593 scopus 로고    scopus 로고
    • Effects of adaptive section collimation on patient radiation dose in multisection spiral CT
    • Deak P.D., Langner O., Lell M., et al. Effects of adaptive section collimation on patient radiation dose in multisection spiral CT. Radiology 2009, 252:140-147.
    • (2009) Radiology , vol.252 , pp. 140-147
    • Deak, P.D.1    Langner, O.2    Lell, M.3
  • 50
    • 63849171406 scopus 로고    scopus 로고
    • The effect of X-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging
    • Perisinakis K., Papadakis A., Damilakis J. The effect of X-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging. Med Phys 2009, 36:1258-1266.
    • (2009) Med Phys , vol.36 , pp. 1258-1266
    • Perisinakis, K.1    Papadakis, A.2    Damilakis, J.3
  • 51
    • 52949134425 scopus 로고    scopus 로고
    • Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality
    • Papadakis A.E., Perisinakis K., Damilakis J. Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality. Med Phys 2008, 35:4567-4576.
    • (2008) Med Phys , vol.35 , pp. 4567-4576
    • Papadakis, A.E.1    Perisinakis, K.2    Damilakis, J.3
  • 52
    • 42949095856 scopus 로고    scopus 로고
    • On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations
    • Perisinakis K., Tzedakis A., Damilakis J. On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations. Med Phys 2008, 35:2018-2028.
    • (2008) Med Phys , vol.35 , pp. 2018-2028
    • Perisinakis, K.1    Tzedakis, A.2    Damilakis, J.3
  • 53
    • 48349111470 scopus 로고    scopus 로고
    • On the uncertainties in effective dose estimates of adult CT head scans
    • Gregory K., Bibbo G., Pattison J. On the uncertainties in effective dose estimates of adult CT head scans. Med Phys 2008, 35:3501-3510.
    • (2008) Med Phys , vol.35 , pp. 3501-3510
    • Gregory, K.1    Bibbo, G.2    Pattison, J.3
  • 54
    • 34147100532 scopus 로고    scopus 로고
    • Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography
    • Theocharopoulos N., Damilakis J., Perisinakis K., et al. Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography. Med Phys 2007, 34:1139-1152.
    • (2007) Med Phys , vol.34 , pp. 1139-1152
    • Theocharopoulos, N.1    Damilakis, J.2    Perisinakis, K.3
  • 55
    • 65549135297 scopus 로고    scopus 로고
    • Evaluation of a patient-specific Monte Carlo software for CT dosimetry
    • Myronakis M., Perisinakis K., Tzedakis A., et al. Evaluation of a patient-specific Monte Carlo software for CT dosimetry. Radiat Prot Dosimetry 2009, 133:248-255.
    • (2009) Radiat Prot Dosimetry , vol.133 , pp. 248-255
    • Myronakis, M.1    Perisinakis, K.2    Tzedakis, A.3
  • 56
    • 69849085948 scopus 로고    scopus 로고
    • Advances in osteoporosis imaging
    • Bauer J.S., Link T.M. Advances in osteoporosis imaging. Eur J Radiol 2009, 71:440-449.
    • (2009) Eur J Radiol , vol.71 , pp. 440-449
    • Bauer, J.S.1    Link, T.M.2
  • 57
    • 33645223911 scopus 로고    scopus 로고
    • Commissioning and quality assurance protocol for dual energy X-ray absorptiometry (DEXA) systems
    • Sheahan N.F., Dowling A., O'Reilly G., et al. Commissioning and quality assurance protocol for dual energy X-ray absorptiometry (DEXA) systems. Radiat Prot Dosimetry 2005, 117:288-290.
    • (2005) Radiat Prot Dosimetry , vol.117 , pp. 288-290
    • Sheahan, N.F.1    Dowling, A.2    O'Reilly, G.3
  • 58
  • 59
    • 77954147474 scopus 로고    scopus 로고
    • Australian and New Zealand Bone and Mineral Society, Australian and New Zealand Association of Physicians in Nuclear Medicine, Royal Australian and New Zealand College of Radiologists, Australasian College of Physical Scientists and Engineers. Accreditation guidelines for bone densitometry, Available at: Accessed February 20, 2010
    • Australian and New Zealand Bone and Mineral Society, Australian and New Zealand Association of Physicians in Nuclear Medicine, Royal Australian and New Zealand College of Radiologists, Australasian College of Physical Scientists and Engineers. Accreditation guidelines for bone densitometry. 2004:21-3. Available at: Accessed February 20, 2010. http://www.anzbms.org.au/resources/DXA/guide/index.htm.
    • (2004) , pp. 21-3
  • 60
    • 77954149176 scopus 로고    scopus 로고
    • American Society of Radiologic Technologists, American Society of Radiologic Technologists, Albuquerque (NM)
    • American Society of Radiologic Technologists Bone densitometry curriculum 2009, American Society of Radiologic Technologists, Albuquerque (NM), p. 1-68.
    • (2009) Bone densitometry curriculum , pp. 1-68
  • 61
    • 77954158318 scopus 로고    scopus 로고
    • Practice guidelines for the performance of dual-energy X-ray absorptiometry (DXA)
    • American College of Radiology, American College of Radiology, Reston (VA), Available at:, Accessed February 20, 2010
    • American College of Radiology Practice guidelines for the performance of dual-energy X-ray absorptiometry (DXA). Practice guidelines and technical standards 2008, 1-10. American College of Radiology, Reston (VA), Available at:, Accessed February 20, 2010. http://www.acr.org/SecondaryMainMenuCategories/quality_safety/guidelines/dx.aspx.
    • (2008) Practice guidelines and technical standards , pp. 1-10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.