The effect of x-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging

Author keywords

Computed tomography; CT dose; CTDI; geometric efficiency; radiation dose profile

Indexed keywords

COMPUTERIZED TOMOGRAPHY; EFFICIENCY; GEOMETRY; PHANTOMS; POLYMETHYL METHACRYLATES;

EID: 63849171406     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3095768     Document Type: Article
Times cited : (21)

References (16)
  • 1
    • 0034499572 scopus 로고    scopus 로고
    • A dose reduction x-ray beam positioning system for high-speed multislice CT
    • 0094-2405 10.1118/1.1323983.
    • T. L. Toth, " A dose reduction x-ray beam positioning system for high-speed multislice CT.," Med. Phys. 0094-2405 10.1118/1.1323983 27, 2659-2668 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2659-2668
    • Toth, T.L.1
  • 2
    • 0034817327 scopus 로고    scopus 로고
    • Multislice CT: Opportunities and challenges
    • 0007-1285
    • M. A. Lewis, " Multislice CT: Opportunities and challenges.," Br. J. Radiol. 74, 779-781 (2001). 0007-1285
    • (2001) Br. J. Radiol. , vol.74 , pp. 779-781
    • Lewis, M.A.1
  • 3
    • 63849238721 scopus 로고    scopus 로고
    • International Electrotechnical Commission, Amendment 1 to IEC 60601-2-44, Edition 2: Medical electrical equipment, Part 2. 44-Particular requirements for the safety of x-ray equipment for computed tomography, International Standard, Geneva, Switzerland, International Electrotechnical Commission
    • International Electrotechnical Commission, Amendment 1 to IEC 60601-2-44, Edition 2: Medical electrical equipment, Part 2. 44-Particular requirements for the safety of x-ray equipment for computed tomography, International Standard, Geneva, Switzerland, International Electrotechnical Commission, 2002, pp. 1-7.
    • (2002) , pp. 1-7
  • 4
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • 0033-8419 10.1148/radiol.2303021726.
    • M. K. Kalra, " Strategies for CT radiation dose optimization.," Radiology 0033-8419 10.1148/radiol.2303021726 230, 619-628 (2004).
    • (2004) Radiology , vol.230 , pp. 619-628
    • Kalra, M.K.1
  • 6
    • 0037372750 scopus 로고    scopus 로고
    • Multi-detector row CT: Radiation dose characteristics
    • 0033-8419 10.1148/radiol.2263020205.
    • L. M. Hamberg, J. T. Rhea, G. J. Hunter, and J. H. Thrall, " Multi-detector row CT: Radiation dose characteristics.," Radiology 0033-8419 10.1148/radiol.2263020205 226, 762-772 (2003).
    • (2003) Radiology , vol.226 , pp. 762-772
    • Hamberg, L.M.1    Rhea, J.T.2    Hunter, G.J.3    Thrall, J.H.4
  • 7
    • 33646455028 scopus 로고    scopus 로고
    • It is time to retire the computed tomography dose index (CTDI) for quality assurance and dose optimization
    • 0094-2405 10.1118/1.2173933.
    • D. J. Brenner, C. H. McCollough, and C. G. Orton, " It is time to retire the computed tomography dose index (CTDI) for quality assurance and dose optimization.," Med. Phys. 0094-2405 10.1118/1.2173933 33, 1189-1191 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 1189-1191
    • Brenner, D.J.1    Mccollough, C.H.2    Orton, C.G.3
  • 8
    • 36048934442 scopus 로고    scopus 로고
    • Determination of the weighted CT dose index in modern multi-detector CT scanners
    • 0031-9155 10.1088/0031-9155/52/21/010.
    • K. Perisinakis, " Determination of the weighted CT dose index in modern multi-detector CT scanners.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/52/21/010 52, 6485-6495 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 6485-6495
    • Perisinakis, K.1
  • 9
    • 34147107446 scopus 로고    scopus 로고
    • The trouble with CTD100
    • 0094-2405 10.1118/1.2713240.
    • J. M. Boone, " The trouble with CTD100.," Med. Phys. 0094-2405 10.1118/1.2713240 34, 1364-1371 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 1364-1371
    • Boone, J.M.1
  • 10
    • 63849169721 scopus 로고    scopus 로고
    • Imaging Performance Assessment of CT Scanners Group, "," ImPACT Report No. 04037.
    • Imaging Performance Assessment of CT Scanners Group, " Siemens Sensation 16 CT scanner technical evaluation.," ImPACT Report No. 04037, 2004.
    • (2004) Siemens Sensation 16 CT scanner technical evaluation
  • 12
    • 36849012640 scopus 로고    scopus 로고
    • Technologic advances in multi-detector CT with a focus on cardiac imaging
    • 0271-5333
    • D. D. Cody and M. Mahesh, " Technologic advances in multi-detector CT with a focus on cardiac imaging.," Radiographics 27, 1829-1837 (2007). 0271-5333
    • (2007) Radiographics , vol.27 , pp. 1829-1837
    • Cody, D.D.1    Mahesh, M.2
  • 14
    • 0003355384 scopus 로고
    • Thermoluminescence Dosimetry
    • (Adam Hilger, Bristol), Vol.
    • A. F. McKinley, " Thermoluminescence Dosimetry.," Medical Physics Handbooks (Adam Hilger, Bristol, 1981), Vol. 5.
    • (1981) Medical Physics Handbooks , vol.5
    • Mckinley, A.F.1
  • 15
    • 46549083950 scopus 로고    scopus 로고
    • Energy dependence of TLD 100 and MCP-N detectors
    • 1350-4487
    • E. Carinou, " Energy dependence of TLD 100 and MCP-N detectors.," Radiat. Meas. 43, 599-602 (2008). 1350-4487
    • (2008) Radiat. Meas. , vol.43 , pp. 599-602
    • Carinou, E.1
  • 16
    • 0038037974 scopus 로고    scopus 로고
    • Radiation exposure at chest CT: A statement of the Fleischner society
    • 0033-8419 10.1148/radiol.2281020874.
    • J. R. Mayo, J. Aldrich, and N. L. Müller, " Radiation exposure at chest CT: A statement of the Fleischner society.," Radiology 0033-8419 10.1148/radiol.2281020874 228, 15-21 (2003).
    • (2003) Radiology , vol.228 , pp. 15-21
    • Mayo, J.R.1    Aldrich, J.2    Müller, N.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.