메뉴 건너뛰기




Volumn 17, Issue 1, 2010, Pages 95-107

An improved methodology for investigating the parameters influencing migration resistance of abdominal aortic stent-grafts

Author keywords

Abdominal aortic aneurysm; Aneurysm model; Displacement force; Stent graft migration

Indexed keywords

SILASTIC; WATER;

EID: 77952504842     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/09-2920.1     Document Type: Article
Times cited : (9)

References (46)
  • 1
    • 21644489363 scopus 로고    scopus 로고
    • Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm
    • Drury D, Michaels JA, Jones L, et al. Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm. Br J Surg. 2005; 92:937-946.
    • (2005) Br J Surg , vol.92 , pp. 937-946
    • Drury, D.1    Michaels, J.A.2    Jones, L.3
  • 2
    • 33846178980 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of 12 years of endovascular abdominal aortic aneurysm repair
    • Franks SC, Sutton AJ, Bown MJ, et al. Systematic review and meta-analysis of 12 years of endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2007;33: 154-171.
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , pp. 154-171
    • Franks, S.C.1    Sutton, A.J.2    Bown, M.J.3
  • 3
    • 33751190067 scopus 로고    scopus 로고
    • Experience with endovascular abdominal aortic aneurysm repair in nonagenarians
    • Baril DT, Palchik E, Carroccio A, et al. Experience with endovascular abdominal aortic aneurysm repair in nonagenarians. J Endovasc Ther. 2006;13:330-337.
    • (2006) J Endovasc Ther , vol.13 , pp. 330-337
    • Baril, D.T.1    Palchik, E.2    Carroccio, A.3
  • 4
    • 49449108619 scopus 로고    scopus 로고
    • A review of the in vivo and in vitro biomechanical behavior and performance of postoperative abdominal aortic aneurysms and implanted stent-grafts
    • Corbett TJ, Callanan A, Morris LG, et al. A review of the in vivo and in vitro biomechanical behavior and performance of postoperative abdominal aortic aneurysms and implanted stent-grafts. J Endovasc Ther. 2008;15:468-484.
    • (2008) J Endovasc Ther , vol.15 , pp. 468-484
    • Corbett, T.J.1    Callanan, A.2    Morris, L.G.3
  • 5
    • 3242714354 scopus 로고    scopus 로고
    • Zenith AAA endovascular graft: Intermediate-term results of the US multicenter trial
    • Greenberg RK, Chuter TA, Sternbergh WC, et al. Zenith AAA endovascular graft: intermediate-term results of the US multicenter trial. J Vasc Surg. 2004;39:1209-1218.
    • (2004) J Vasc Surg , vol.39 , pp. 1209-1218
    • Greenberg, R.K.1    Chuter, T.A.2    Sternbergh, W.C.3
  • 6
    • 0037380847 scopus 로고    scopus 로고
    • The US AneuRx Clinical Trial: 6-Year clinical update 2002
    • AneuRx Clinical Investigators
    • Zarins CK. AneuRx Clinical Investigators. The US AneuRx Clinical Trial: 6-year clinical update 2002. J Vasc Surg. 2003;37:904-908.
    • (2003) J Vasc Surg , vol.37 , pp. 904-908
    • Zarins, C.K.1
  • 7
    • 0034164052 scopus 로고    scopus 로고
    • Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms
    • Albertini JN, Kalliafas S, Travis S, et al. Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2000;19:308-312.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 308-312
    • Albertini, J.N.1    Kalliafas, S.2    Travis, S.3
  • 8
    • 0031647079 scopus 로고    scopus 로고
    • Endovascular AAA exclusion: Will stents with hooks and barbs prevent stent-graft migration?
    • Malina M, Lindblad B, Ivancev K, et al. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration? J Endovasc Surg. 1998;5:310-317.
    • (1998) J Endovasc Surg , vol.5 , pp. 310-317
    • Malina, M.1    Lindblad, B.2    Ivancev, K.3
  • 9
    • 0033052652 scopus 로고    scopus 로고
    • Experimental assessment of proximal stentgraft (IntervascularTM) fixation in human cadaveric infrarenal aortas
    • Lambert AW, Williams DJ, Budd JS, et al. Experimental assessment of proximal stentgraft (IntervascularTM) fixation in human cadaveric infrarenal aortas. Eur J Vasc Endovasc Surg. 1999;17:60-65.
    • (1999) Eur J Vasc Endovasc Surg , vol.17 , pp. 60-65
    • Lambert, A.W.1    Williams, D.J.2    Budd, J.S.3
  • 10
    • 0033845597 scopus 로고    scopus 로고
    • The impact of stent design on proximal stent-graft fixation in the abdominal aorta: An experimental study
    • Resch T, Malina M, Lindblad B, et al. The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. Eur J Vasc Endovasc Surg. 2000;20:190-195.
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , pp. 190-195
    • Resch, T.1    Malina, M.2    Lindblad, B.3
  • 11
    • 1642535329 scopus 로고    scopus 로고
    • Improvement in proximal aortic endograft fixation: An experimental study using different stent-grafts in human cadaveric aortas
    • Veerapen R, Dorandeu A, Serre I, et al. Improvement in proximal aortic endograft fixation: an experimental study using different stent-grafts in human cadaveric aortas. J Endovasc Ther. 2003;10:1101-1109.
    • (2003) J Endovasc Ther , vol.10 , pp. 1101-1109
    • Veerapen, R.1    Dorandeu, A.2    Serre, I.3
  • 12
    • 18344370805 scopus 로고    scopus 로고
    • Iliac fixation length and resistance to in-vivo stent graft displacement
    • Arko FR, Heikkinen MA, Lee ES, et al. Iliac fixation length and resistance to in-vivo stent graft displacement. J Vasc Surg. 2005;41: 664-671.
    • (2005) J Vasc Surg , vol.41 , pp. 664-671
    • Arko, F.R.1    Heikkinen, M.A.2    Lee, E.S.3
  • 13
    • 34848852449 scopus 로고    scopus 로고
    • Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation
    • Murphy EH, Johnson ED, Arko FR. Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation. J Endovasc Ther. 2007;14:585-592.
    • (2007) J Endovasc Ther , vol.14 , pp. 585-592
    • Murphy, E.H.1    Johnson, E.D.2    Arko, F.R.3
  • 14
    • 0032159874 scopus 로고    scopus 로고
    • Development of a simulator for endovascular repair of abdominal aortic aneurysms
    • Chong CK, How TV, Black RA, et al. Development of a simulator for endovascular repair of abdominal aortic aneurysms. Ann Biomed Eng. 1998;26:798-802.
    • (1998) Ann Biomed Eng , vol.26 , pp. 798-802
    • Chong, C.K.1    How, T.V.2    Black, R.A.3
  • 15
    • 0141479058 scopus 로고    scopus 로고
    • Modeling endoleaks and collateral reperfusion following endovascular AAA exclusion
    • Chong CK, How TV, Gilling-Smith GL, et al. Modeling endoleaks and collateral reperfusion following endovascular AAA exclusion. J Endovasc Ther. 2003;10:424-432.
    • (2003) J Endovasc Ther , vol.10 , pp. 424-432
    • Chong, C.K.1    How, T.V.2    Gilling-Smith, G.L.3
  • 16
    • 0346996702 scopus 로고    scopus 로고
    • Flow patterns in an endovascular stent-graft for abdominal aortic aneurysm repair
    • Chong CK, How TV. Flow patterns in an endovascular stent-graft for abdominal aortic aneurysm repair. J Biomech. 2004;37:89-97.
    • (2004) J Biomech , vol.37 , pp. 89-97
    • Chong, C.K.1    How, T.V.2
  • 17
    • 23344433873 scopus 로고    scopus 로고
    • Flow visualization in a model of a bifurcated stent-graft
    • Chong CK, How TV, Harris PL. Flow visualization in a model of a bifurcated stent-graft. J Endovasc Ther. 2005;12:435-445.
    • (2005) J Endovasc Ther , vol.12 , pp. 435-445
    • Chong, C.K.1    How, T.V.2    Harris, P.L.3
  • 18
    • 0037380684 scopus 로고    scopus 로고
    • Significance of endotension, endoleak, and aneurysm pulsatility after endovascular repair
    • Mehta M, Veith FJ, Ohki T, et al. Significance of endotension, endoleak, and aneurysm pulsatility after endovascular repair. J Vasc Surg. 2003;37:842-846.
    • (2003) J Vasc Surg , vol.37 , pp. 842-846
    • Mehta, M.1    Veith, F.J.2    Ohki, T.3
  • 19
    • 0242299762 scopus 로고    scopus 로고
    • Endotension as a result of pressure transmission over the graft following endovascular aneurysm repair - An in vitro study
    • Gawenda M, Jaschke G, Winter S, et al. Endotension as a result of pressure transmission over the graft following endovascular aneurysm repair - an in vitro study. Eur J Vasc Endovasc Surg. 2003;26:501-505.
    • (2003) Eur J Vasc Endovasc Surg , vol.26 , pp. 501-505
    • Gawenda, M.1    Jaschke, G.2    Winter, S.3
  • 20
    • 0346264736 scopus 로고    scopus 로고
    • Endotension is influenced by wall compliance in a latex aneurysm model
    • Gawenda M, Knez P, Winter S, et al. Endotension is influenced by wall compliance in a latex aneurysm model. Eur J Vasc Endovasc Surg. 2004;27:45-50.
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 45-50
    • Gawenda, M.1    Knez, P.2    Winter, S.3
  • 21
    • 4444236192 scopus 로고    scopus 로고
    • Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: An experimental study
    • Chaudhuri A, Ansdell LE, Grass AJ, et al. Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study. Eur J Vasc Endovasc Surg. 2004;28:373-378.
    • (2004) Eur J Vasc Endovasc Surg , vol.28 , pp. 373-378
    • Chaudhuri, A.1    Ansdell, L.E.2    Grass, A.J.3
  • 22
    • 1442354288 scopus 로고    scopus 로고
    • Aneurysmal hypertension and its relationship to sac thrombus: A semi-qualitative analysis by experimental fluid mechanics
    • Chaudhuri A, Ansdell LE, Grass AJ. Aneurysmal hypertension and its relationship to sac thrombus: a semi-qualitative analysis by experimental fluid mechanics. Eur J Vasc Endovasc Surg. 2004;27:305-310.
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 305-310
    • Chaudhuri, A.1    Ansdell, L.E.2    Grass, A.J.3
  • 23
    • 70349462957 scopus 로고    scopus 로고
    • Experimental modelling of aortic aneurysms: Novel applications of silicone rubbers
    • Doyle BJ, Corbett TJ, Cloonan AJ, et al. Experimental modelling of aortic aneurysms: novel applications of silicone rubbers. Med Eng Phys. 2009;31:1002-1012.
    • (2009) Med Eng Phys , vol.31 , pp. 1002-1012
    • Doyle, B.J.1    Corbett, T.J.2    Cloonan, A.J.3
  • 24
    • 68549099655 scopus 로고    scopus 로고
    • An experimental and numerical comparison of the rupture locations of an abdominal aortic aneurysm
    • Doyle BJ, Corbett TJ, Callanan A, et al. An experimental and numerical comparison of the rupture locations of an abdominal aortic aneurysm. J Endovasc Ther. 2009;16:322-335.
    • (2009) J Endovasc Ther , vol.16 , pp. 322-335
    • Doyle, B.J.1    Corbett, T.J.2    Callanan, A.3
  • 25
    • 27744580957 scopus 로고    scopus 로고
    • Injection-moulded models of major and minor arteries: The variability of model wall thickness owing to casting technique
    • O'Brien T, Morris L, O'Donnell M, et al. Injection-moulded models of major and minor arteries: the variability of model wall thickness owing to casting technique. Proc Inst Mech Eng [H]. 2005;219:381-386.
    • (2005) Proc Inst Mech Eng [H] , vol.219 , pp. 381-386
    • O'Brien, T.1    Morris, L.2    O'Donnell, M.3
  • 26
    • 10244244917 scopus 로고    scopus 로고
    • Experimental assessment of stress patterns in abdominal aortic aneurysms using the photo-elastic method
    • Morris L, O'Donnell P, Delassus P, et al. Experimental assessment of stress patterns in abdominal aortic aneurysms using the photo-elastic method. Strain. 2004;40:165-172.
    • (2004) Strain , vol.40 , pp. 165-172
    • Morris, L.1    O'Donnell, P.2    Delassus, P.3
  • 27
    • 38149102288 scopus 로고    scopus 로고
    • Evidence suggests rigid aortic grafts increase systolic blood pressure: Results of a preliminary study
    • O'Brien T, Morris L, Mcgloughlin T. Evidence suggests rigid aortic grafts increase systolic blood pressure: results of a preliminary study. Med Eng Phys. 2008;30:109-115.
    • (2008) Med Eng Phys , vol.30 , pp. 109-115
    • O'Brien, T.1    Morris, L.2    Mcgloughlin, T.3
  • 28
    • 84967361522 scopus 로고    scopus 로고
    • Numerical and experimental techniques for the study of biomechanics in the arterial system
    • Leondes CT, ed. Singapore: World Scientific Publishing Co.
    • O'Brien T, Walsh MT, Morris LG, et al. Numerical and experimental techniques for the study of biomechanics in the arterial system. In: Leondes CT, ed. Biomechanical Systems Technology. Singapore: World Scientific Publishing Co.; 2008:233-270.
    • (2008) Biomechanical Systems Technology , pp. 233-270
    • O'Brien, T.1    Walsh, M.T.2    Morris, L.G.3
  • 29
    • 77955100437 scopus 로고    scopus 로고
    • Engineering silicone rubbers for in vitro studies: Creating AAA models and ILT analogues with physiological properties
    • DOI: 10.1115/1.4000156
    • Corbett TJ, Doyle BJ, Callanan A, et al. Engineering silicone rubbers for in vitro studies: creating AAA models and ILT analogues with physiological properties. J Biomech Eng. 2010;132:011008. DOI: 10.1115/1.4000156.
    • (2010) J Biomech Eng , vol.132 , pp. 011008
    • Corbett, T.J.1    Doyle, B.J.2    Callanan, A.3
  • 31
    • 46749118399 scopus 로고    scopus 로고
    • 3D reconstruction and manufacture of real abdominal aortic aneurysms: From CT scan to silicone model
    • Doyle BJ, Morris LG, Callanan A, et al. 3D reconstruction and manufacture of real abdominal aortic aneurysms: from CT scan to silicone model. J Biomech Eng. 2008;130: 034501-1-034501-5.
    • (2008) J Biomech Eng , vol.130
    • Doyle, B.J.1    Morris, L.G.2    Callanan, A.3
  • 32
    • 0028557870 scopus 로고
    • Sex difference in the mechanical properties of the abdominal aorta in human beings
    • Sonesson B, Lanne T, Vernerson E, et al. Sex difference in the mechanical properties of the abdominal aorta in human beings. J Vasc Surg. 1994;20:959-969.
    • (1994) J Vasc Surg , vol.20 , pp. 959-969
    • Sonesson, B.1    Lanne, T.2    Vernerson, E.3
  • 33
    • 0030483007 scopus 로고    scopus 로고
    • Potential influence of intraluminal thrombus on abdominal aortic aneurysm as assessed by a new non-invasive method
    • Vorp DA, Mandarino M, Webster MW, et al. Potential influence of intraluminal thrombus on abdominal aortic aneurysm as assessed by a new non-invasive method. Cardiovasc Surg. 1996;4:732-739.
    • (1996) Cardiovasc Surg , vol.4 , pp. 732-739
    • Vorp, D.A.1    Mandarino, M.2    Webster, M.W.3
  • 34
    • 67349108294 scopus 로고    scopus 로고
    • Oversizing of aortic stent grafts for abdominal aneurysm repair: A systematic review of the benefits and risks
    • van Prehn J, Schlösser FJ, Muhs BE, et al. Oversizing of aortic stent grafts for abdominal aneurysm repair: a systematic review of the benefits and risks. Eur J Vasc Endovasc Surg. 2009;38:42-53.
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 42-53
    • Van Prehn, J.1    Schlösser, F.J.2    Muhs, B.E.3
  • 36
    • 33845776167 scopus 로고    scopus 로고
    • Development of fibrinous thrombus analogue for in vitro abdominal aortic aneurysm studies
    • Hinnen JW, Rixen DJ, Koning OH, et al. Development of fibrinous thrombus analogue for in vitro abdominal aortic aneurysm studies. J Biomech. 2007;40:289-295.
    • (2007) J Biomech , vol.40 , pp. 289-295
    • Hinnen, J.W.1    Rixen, D.J.2    Koning, O.H.3
  • 37
    • 0035659797 scopus 로고    scopus 로고
    • Mechanical properties and microstructure of intraluminal thrombus from abdominal aortic aneurysm
    • Wang DH, Makaroun M, Vorp DA. Mechanical properties and microstructure of intraluminal thrombus from abdominal aortic aneurysm. J Biomech Eng. 2001;123:536-539.
    • (2001) J Biomech Eng , vol.123 , pp. 536-539
    • Wang, D.H.1    Makaroun, M.2    Vorp, D.A.3
  • 38
    • 0036733325 scopus 로고    scopus 로고
    • Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: A cautionary note
    • Conners MS, Sternbergh WC, Carter G, et al. Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: a cautionary note. J Vasc Surg. 2002;36:476-484.
    • (2002) J Vasc Surg , vol.36 , pp. 476-484
    • Conners, M.S.1    Sternbergh, W.C.2    Carter, G.3
  • 39
    • 0346964283 scopus 로고    scopus 로고
    • Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: Results from the Zenith Multicenter Trial
    • Sternbergh WC, Money SR, Greenberg RK, et al. Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter Trial. J Vasc Surg. 2004;39: 20-26.
    • (2004) J Vasc Surg , vol.39 , pp. 20-26
    • Sternbergh, W.C.1    Money, S.R.2    Greenberg, R.K.3
  • 40
    • 21044444277 scopus 로고    scopus 로고
    • AneuRx device migration: Incidence, risk factors, and consequences
    • Sampaio SM, Panneton JM, Mozes G, et al. AneuRx device migration: incidence, risk factors, and consequences. Ann Vasc Surg. 2005;19:178-185.
    • (2005) Ann Vasc Surg , vol.19 , pp. 178-185
    • Sampaio, S.M.1    Panneton, J.M.2    Mozes, G.3
  • 41
    • 0036481881 scopus 로고    scopus 로고
    • Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years
    • Cao P, Verzini F, Zannetti S, et al. Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg. 2002;35:229-235.
    • (2002) J Vasc Surg , vol.35 , pp. 229-235
    • Cao, P.1    Verzini, F.2    Zannetti, S.3
  • 42
    • 37049001021 scopus 로고    scopus 로고
    • Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm
    • Fraser K, Meagher S, Blake JR, et al. Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm. Ultrasound Med Biol. 2008;34:73-80.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 73-80
    • Fraser, K.1    Meagher, S.2    Blake, J.R.3
  • 43
    • 56349123845 scopus 로고    scopus 로고
    • Geometrical enhancements for abdominal aortic stent-grafts
    • Molony DS, Callanan A, Morris LG, et al. Geometrical enhancements for abdominal aortic stent-grafts. J Endovasc Ther. 2008;15: 518-529.
    • (2008) J Endovasc Ther , vol.15 , pp. 518-529
    • Molony, D.S.1    Callanan, A.2    Morris, L.G.3
  • 44
    • 48449102711 scopus 로고    scopus 로고
    • Measurement of pulsatile hemodynamic forces in a model of a bifurcated stent-graft for abdominal aortic aneurysm repair
    • Zhou SN, How TV, Black RA, et al. Measurement of pulsatile hemodynamic forces in a model of a bifurcated stent-graft for abdominal aortic aneurysm repair. Proc Inst Mech Eng [H]. 2008;222:543-549.
    • (2008) Proc Inst Mech Eng [H] , vol.222 , pp. 543-549
    • Zhou, S.N.1    How, T.V.2    Black, R.A.3
  • 45
    • 0036266918 scopus 로고    scopus 로고
    • Re: Analytical modeling and numerical simulation of forces in an endoluminal graft
    • Letter
    • Moore JE. Re: Analytical modeling and numerical simulation of forces in an endoluminal graft [Letter]. J Endovasc Ther. 2002;9:251.
    • (2002) J Endovasc Ther , vol.9 , pp. 251
    • Moore, J.E.1
  • 46
    • 30844462131 scopus 로고    scopus 로고
    • Effect of flat, parabolic and realistic steady flow inlet profiles on idealised and realistic stent graft fits through abdominal aortic aneurysms (AAA)
    • Morris L, Delassus P, Grace P, et al. Effect of flat, parabolic and realistic steady flow inlet profiles on idealised and realistic stent graft fits through abdominal aortic aneurysms (AAA). Med Eng Phys. 2006;28:19-26.
    • (2006) Med Eng Phys , vol.28 , pp. 19-26
    • Morris, L.1    Delassus, P.2    Grace, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.