메뉴 건너뛰기




Volumn 37, Issue 4, 2003, Pages 842-846

Significance of endotension, endoleak, and aneurysm pulsatility after endovascular repair

Author keywords

[No Author keywords available]

Indexed keywords

ANEURYSM; ARTICLE; ENDOVASCULAR SURGERY; PALPATION; POLITEF IMPLANT; PRESSURE; PRESSURE TRANSDUCER; PRIORITY JOURNAL; PULSATILE FLOW; PUMP; STENT; SYSTEMIC CIRCULATION; TENSION; THROMBUS;

EID: 0037380684     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2003.183     Document Type: Article
Times cited : (54)

References (17)
  • 1
    • 0031019823 scopus 로고    scopus 로고
    • Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    • Blum U, Voshage G, Lammer J, et al. Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Engl J Med 1997;336:13-20.
    • (1997) N Engl J Med , vol.336 , pp. 13-20
    • Blum, U.1    Voshage, G.2    Lammer, J.3
  • 2
    • 0029998672 scopus 로고    scopus 로고
    • Transfemoral endovascular repair of abdominal aortic aneurysms: Results of North America EVT phase 1 trial
    • Moore WS, Rutherford RB. Transfemoral endovascular repair of abdominal aortic aneurysms: Results of North America EVT phase 1 trial. J Vasc Surg 1996;23:543-53.
    • (1996) J Vasc Surg , vol.23 , pp. 543-553
    • Moore, W.S.1    Rutherford, R.B.2
  • 3
    • 0034940426 scopus 로고    scopus 로고
    • All sealed endoleaks are not the same: A treatment strategy based on an ex-vivo analysis
    • Mehta M, Ohki T, Veith FJ, Lipsitz EC. All sealed endoleaks are not the same: A treatment strategy based on an ex-vivo analysis. Eur J Vasc Endovasc Surg 2001;21:541-4.
    • (2001) Eur J Vasc Endovasc Surg , vol.21 , pp. 541-544
    • Mehta, M.1    Ohki, T.2    Veith, F.J.3    Lipsitz, E.C.4
  • 4
    • 0031849583 scopus 로고    scopus 로고
    • Endoleakage after stentgraft treatment of abdominal aneurysms: Implications on pressure imaging; an in vitro study
    • Schurink GW, Aarts NJ, Wilde J, et al. Endoleakage after stentgraft treatment of abdominal aneurysms: Implications on pressure imaging; an in vitro study. J Vasc Surg 1998;28:234-41.
    • (1998) J Vasc Surg , vol.28 , pp. 234-241
    • Schurink, G.W.1    Aarts, N.J.2    Wilde, J.3
  • 5
    • 0035145775 scopus 로고    scopus 로고
    • Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms
    • Baum RA, Carpenter JP, Cope C, et al. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 2001;33:32-41.
    • (2001) J Vasc Surg , vol.33 , pp. 32-41
    • Baum, R.A.1    Carpenter, J.P.2    Cope, C.3
  • 6
    • 0034177344 scopus 로고    scopus 로고
    • Freedom from endoleak after endovascular aneurysm repair does not equal treatment success
    • Gilling-Smith GL, Martin J, Sudhindran S, et al. Freedom from endoleak after endovascular aneurysm repair does not equal treatment success. Eur J Vasc Endovasc Surg 2000;19:421-5.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 421-425
    • Gilling-Smith, G.L.1    Martin, J.2    Sudhindran, S.3
  • 7
    • 0031820342 scopus 로고    scopus 로고
    • Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft
    • Torsello GB, Klenk E, Kaspizak B, Umscheid T. Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft. J Vasc Surg 1998;28:184-7.
    • (1998) J Vasc Surg , vol.28 , pp. 184-187
    • Torsello, G.B.1    Klenk, E.2    Kaspizak, B.3    Umscheid, T.4
  • 8
    • 0034042336 scopus 로고    scopus 로고
    • Aneurysm rupture after endovascular repair using the AneuRx stent graft
    • Zarins CK, White RA, Fogarty TJ. Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 2000;31:960-70.
    • (2000) J Vasc Surg , vol.31 , pp. 960-970
    • Zarins, C.K.1    White, R.A.2    Fogarty, T.J.3
  • 9
    • 0034061745 scopus 로고    scopus 로고
    • Late abdominal aortic aneurysm rupture after AneuRx repair: A report of three cases
    • Politz JK, Newman VS, Stewart MT. Late abdominal aortic aneurysm rupture after AneuRx repair: A report of three cases. J Vasc Surg 2000;31:599-606.
    • (2000) J Vasc Surg , vol.31 , pp. 599-606
    • Politz, J.K.1    Newman, V.S.2    Stewart, M.T.3
  • 10
    • 0032801835 scopus 로고    scopus 로고
    • The incidence, natural history, and outcome of secondary intervention for persistent collateral flow in the excluded abdominal aortic aneurysm
    • Darling RC, Ozsvath K, Chang BB, Kreienberg PB, Paty PS, Lloyd WE, et al. The incidence, natural history, and outcome of secondary intervention for persistent collateral flow in the excluded abdominal aortic aneurysm. J Vasc Surg 1999;30:968-76.
    • (1999) J Vasc Surg , vol.30 , pp. 968-976
    • Darling, R.C.1    Ozsvath, K.2    Chang, B.B.3    Kreienberg, P.B.4    Paty, P.S.5    Lloyd, W.E.6
  • 11
    • 0035380667 scopus 로고    scopus 로고
    • Hypogastric artery aneurysm rupture after endovascular graft exclusion with shrinkage of the aneurysm: Significance of endotension from a "virtual," of thrombosed type II endoleak
    • Bade MA, Ohki T, Cynamon J, Veith FJ. Hypogastric artery aneurysm rupture after endovascular graft exclusion with shrinkage of the aneurysm: Significance of endotension from a "virtual," of thrombosed type II endoleak. J Vasc Surg 2001;33:1271-4.
    • (2001) J Vasc Surg , vol.33 , pp. 1271-1274
    • Bade, M.A.1    Ohki, T.2    Cynamon, J.3    Veith, F.J.4
  • 12
    • 0034001024 scopus 로고    scopus 로고
    • A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair
    • Greenburg R, Green R. A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair. J Vasc Surg 2000;31:836-7.
    • (2000) J Vasc Surg , vol.31 , pp. 836-837
    • Greenburg, R.1    Green, R.2
  • 13
    • 0031938732 scopus 로고    scopus 로고
    • Endoleaks after endovascular graft treatment of aortic aneurysms: Classifications, risk factors, and outcomes
    • Wain RA, Marin ML, Ohki T, et al. Endoleaks after endovascular graft treatment of aortic aneurysms: Classifications, risk factors, and outcomes. J Vasc Surg 1998;27:69-80.
    • (1998) J Vasc Surg , vol.27 , pp. 69-80
    • Wain, R.A.1    Marin, M.L.2    Ohki, T.3
  • 14
    • 0015320218 scopus 로고
    • Clinical fate of the patient with asymptomatic abdominal aortic aneurysm and unfit for surgical treatment
    • Szilagyi DE, Elliott JP, Smith RF. Clinical fate of the patient with asymptomatic abdominal aortic aneurysm and unfit for surgical treatment. Arch Surg 1972;104:600-6.
    • (1972) Arch Surg , vol.104 , pp. 600-606
    • Szilagyi, D.E.1    Elliott, J.P.2    Smith, R.F.3
  • 15
    • 0033785947 scopus 로고    scopus 로고
    • Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks: Comparison of wall track system and M-mode ultrasound scanning; An in vitro and animal study
    • Schurink GH, Aarts NJM, Malina M, Bockel JH. Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks: Comparison of wall track system and M-mode ultrasound scanning; An in vitro and animal study. J Vasc Surg 2000;32:795-803.
    • (2000) J Vasc Surg , vol.32 , pp. 795-803
    • Schurink, G.H.1    Aarts, N.J.M.2    Malina, M.3    Bockel, J.H.4
  • 16
    • 0031894283 scopus 로고    scopus 로고
    • Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular aneurysm repair
    • Malina M, Lanne T, Ivancev K, Lindblad B, Brunkwall J. Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular aneurysm repair. J Vasc Surg 1998;27:624-31.
    • (1998) J Vasc Surg , vol.27 , pp. 624-631
    • Malina, M.1    Lanne, T.2    Ivancev, K.3    Lindblad, B.4    Brunkwall, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.