메뉴 건너뛰기




Volumn 27, Issue 3, 2004, Pages 305-310

Aneurysmal hypertension and its relationship to sac thrombus: A semi-qualitative analysis by experimental fluid mechanics

Author keywords

Aneurysm thrombus; Aneurysmal hypertension; Bernoulli's principle; Pascal's law

Indexed keywords

GELATIN;

EID: 1442354288     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejvs.2003.11.010     Document Type: Article
Times cited : (12)

References (16)
  • 1
    • 0037929661 scopus 로고    scopus 로고
    • Potential influence of intraluminal thrombus on AAA as assessed by new non invasive methods
    • Vorp DA, Mandarino WA, Webster MW, Gorscan J. Potential influence of intraluminal thrombus on AAA as assessed by new non invasive methods. Cardiovasc Surg 1996; 4: 32-39.
    • (1996) Cardiovasc. Surg. , vol.4 , pp. 32-39
    • Vorp, D.A.1    Mandarino, W.A.2    Webster, M.W.3    Gorscan, J.4
  • 2
    • 0034060255 scopus 로고    scopus 로고
    • Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall
    • Schurink GWH, van Baalen JM, Visser MJT et al. Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall. J Vasc Surg 2000; 31(3): 501-506.
    • (2000) J. Vasc. Surg. , vol.31 , Issue.3 , pp. 501-506
    • Schurink, G.W.H.1    van Baalen, J.M.2    Visser, M.J.T.3
  • 4
    • 0036814329 scopus 로고    scopus 로고
    • Aneurysm wall stress and tendency to rupture are features of physical wall properties: An experimental study
    • Flora HS, Talei-Faz B, Ansdell L et al. Aneurysm wall stress and tendency to rupture are features of physical wall properties: an experimental study. J Endovasc Ther 2002; 9(5): 665-675.
    • (2002) J. Endovasc. Ther. , vol.9 , Issue.5 , pp. 665-675
    • Flora, H.S.1    Talei-Faz, B.2    Ansdell, L.3
  • 5
    • 0017128390 scopus 로고
    • The measurement of radioactive microspheres in biological samples
    • Mernagh J, Spiers W, Adiseshiah M. The measurement of radioactive microspheres in biological samples. Phys Med Biol 1976; 21: 646.
    • (1976) Phys. Med. Biol. , vol.21 , pp. 646
    • Mernagh, J.1    Spiers, W.2    Adiseshiah, M.3
  • 6
    • 0141813684 scopus 로고    scopus 로고
    • Can monitoring of intra-aneurysm pressure accurately predict failure of endovascular aneurysm repair?
    • Vallabhaneni SR, Gilling-Smith GL, Brennan JA et al. Can monitoring of intra-aneurysm pressure accurately predict failure of endovascular aneurysm repair? J Endovasc Ther 2003; 10(3): 524-530.
    • (2003) J. Endovasc. Ther. , vol.10 , Issue.3 , pp. 524-530
    • Vallabhaneni, S.R.1    Gilling-Smith, G.L.2    Brennan, J.A.3
  • 7
    • 0030806619 scopus 로고    scopus 로고
    • Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress
    • Mower WR, Quinones WJ, Gambhir SS. Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress. J Vasc Surg 1997; 26(4): 602-608.
    • (1997) J. Vasc. Surg. , vol.26 , Issue.4 , pp. 602-608
    • Mower, W.R.1    Quinones, W.J.2    Gambhir, S.S.3
  • 8
    • 0141590522 scopus 로고    scopus 로고
    • Effects of types I and II endoleaks on the distribution of aneurysm sac pressure of aneurysm sac pressure in an experimental model
    • Xenos ES, Pacanowski JP, Stevens SL et al. Effects of types I and II endoleaks on the distribution of aneurysm sac pressure of aneurysm sac pressure in an experimental model. J Endovasc Ther 2003; 10(3): 516-523.
    • (2003) J. Endovasc. Ther. , vol.10 , Issue.3 , pp. 516-523
    • Xenos, E.S.1    Pacanowski, J.P.2    Stevens, S.L.3
  • 9
    • 0023253816 scopus 로고
    • The influence of aorta-aneurysm geometry upon stress in the aneurysm wall
    • Stringfellow MM, Lawrence PF, Stringfellow R. The influence of aorta-aneurysm geometry upon stress in the aneurysm wall. J Surg Res 1987; 42: 425-433.
    • (1987) J. Surg. Res. , vol.42 , pp. 425-433
    • Stringfellow, M.M.1    Lawrence, P.F.2    Stringfellow, R.3
  • 10
    • 0033999346 scopus 로고    scopus 로고
    • Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm
    • Raghavan ML, Vorp DA, Federle MP, Makaroun MS, Webster MW. Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm. J Vasc Surg 2000; 31(4): 760-769.
    • (2000) J. Vasc. Surg. , vol.31 , Issue.4 , pp. 760-769
    • Raghavan, M.L.1    Vorp, D.A.2    Federle, M.P.3    Makaroun, M.S.4    Webster, M.W.5
  • 11
    • 0004180181 scopus 로고
    • 6th ed. London: Van Nostrand Reinhold
    • Massey BS, 6th ed. Mechanics of fluids, London: Van Nostrand Reinhold, 1989. p. 78.
    • (1989) Mechanics of Fluids , pp. 78
    • Massey, B.S.1
  • 12
    • 0023896127 scopus 로고    scopus 로고
    • Computed tomography of abdominal aortic aneurysms: An in vivo pathological report with a note on dynamic predictors
    • Pillary G, Jang GB, Zito J, Cohn Jr. Computed tomography of abdominal aortic aneurysms: an in vivo pathological report with a note on dynamic predictors. Arch Surg 1998; 123: 727-732.
    • (1998) Arch. Surg. , vol.123 , pp. 727-732
    • Pillary, G.1    Jang, G.B.2    Zito, J.3    Cohn, J.R.4
  • 13
    • 0034518306 scopus 로고    scopus 로고
    • Growth of thrombus may be a better predictor of rupture than diameter inpatients with abdominal aortic aneurysms
    • Stenbaek J, Kalin B, Swedenborg J. Growth of thrombus may be a better predictor of rupture than diameter inpatients with abdominal aortic aneurysms. Eur J Vasc Surg 2000; 20: 466-469.
    • (2000) Eur. J. Vasc. Surg. , vol.20 , pp. 466-469
    • Stenbaek, J.1    Kalin, B.2    Swedenborg, J.3
  • 14
    • 0028072101 scopus 로고
    • Computer tomography scan findings associated with rapid expansion of abdominal aortic aneurysms
    • Wolf YG, Thomas WS, Brennan FJ et al. Computer tomography scan findings associated with rapid expansion of abdominal aortic aneurysms. J Vasc Surg 1994; 20: 535-538.
    • (1994) J. Vasc. Surg. , vol.20 , pp. 535-538
    • Wolf, Y.G.1    Thomas, W.S.2    Brennan, F.J.3
  • 15
    • 0004180181 scopus 로고
    • 6th ed. London: Van Nostrand Reinhold
    • Massey BS, 6th ed. Mechanics of fluids, London: Van Nostrand Reinhold, 1989. p. 209-210.
    • (1989) Mechanics of Fluids , pp. 209-210
    • Massey, B.S.1
  • 16
    • 0038372488 scopus 로고    scopus 로고
    • Relationship of residual intraluminal to intrathrombotic pressure in a closed aneurysmal sac
    • Hans SS, Jareunpoon O, Huang R, Hans B, Bove P, Zelenock GB. Relationship of residual intraluminal to intrathrombotic pressure in a closed aneurysmal sac. J Vasc Surg 2003; 37(5): 949-953.
    • (2003) J. Vasc. Surg. , vol.37 , Issue.5 , pp. 949-953
    • Hans, S.S.1    Jareunpoon, O.2    Huang, R.3    Hans, B.4    Bove, P.5    Zelenock, G.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.