메뉴 건너뛰기




Volumn 222, Issue 4, 2008, Pages 543-549

Measurement of pulsatile haemodynamics forces in a model of a bifurcated stent graft for abdominal aortic aneurysm repair

Author keywords

Endovascular repair; Migration; Strain gauges

Indexed keywords

BLOOD VESSELS; BRIDGE CIRCUITS; COMPUTER NETWORKS; COMPUTERIZED TOMOGRAPHY; GAGES; GLYCEROL; GRAFTING (CHEMICAL); HYDRODYNAMICS; MAINTENANCE; PERSONAL COMPUTERS; PULSATILE FLOW; THICKNESS MEASUREMENT; ONE DIMENSIONAL; SIGNAL CONDITIONING CIRCUITS; STENTS; STRAIN; STRAIN GAGES;

EID: 48449102711     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM311     Document Type: Article
Times cited : (10)

References (17)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi, J. C., Palmaz, J. C., and Barone, H. D. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann. Vascular Surg., 1991, 5, 491-499.
    • (1991) Ann. Vascular Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 84993746135 scopus 로고    scopus 로고
    • Endovascular aneurysm repair versus open repair in patients wiih abdominal aortic aneurysm (EVAR trial 1): Randomised controlled trial
    • EVAR trial participants
    • EVAR trial participants, Endovascular aneurysm repair versus open repair in patients wiih abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial. Lancet, 2005, 365, 2179-2186.
    • (2005) Lancet , vol.365 , pp. 2179-2186
  • 3
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris, P. L., Vallabheneni, S. R., Desgranges, P., Becquemin, J. P., Van Marriewijk, C., and Laheij, R. J. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J. Vascular Surg., 2000, 32, 739-749.
    • (2000) J. Vascular Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabheneni, S.R.2    Desgranges, P.3    Becquemin, J.P.4    Van Marriewijk, C.5    Laheij, R.J.6
  • 4
    • 0037003381 scopus 로고    scopus 로고
    • Mohan, I. V., Harris, P. L., Van Marrlewijk, C., Lahe1j, R. J. F., and How, T. V. Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. J. Endovascular Therapy, 2002, 9, 748-755.
    • Mohan, I. V., Harris, P. L., Van Marrlewijk, C., Lahe1j, R. J. F., and How, T. V. Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. J. Endovascular Therapy, 2002, 9, 748-755.
  • 7
    • 1642535329 scopus 로고    scopus 로고
    • Improvement in proximal aortic endograft fixation: An experimental study using different stent-grafts in human cadaveric aortas
    • Veerapen, R., Dorandeu, A., Serre, I., Berthet, J. P., Marty-Ane, C. H., Mary, H., and Alric, P. Improvement in proximal aortic endograft fixation: an experimental study using different stent-grafts in human cadaveric aortas. J. Endovascular Therapy, 2003, 10, 1101-1109.
    • (2003) J. Endovascular Therapy , vol.10 , pp. 1101-1109
    • Veerapen, R.1    Dorandeu, A.2    Serre, I.3    Berthet, J.P.4    Marty-Ane, C.H.5    Mary, H.6    Alric, P.7
  • 8
    • 0031595465 scopus 로고    scopus 로고
    • Rupture of an abdominal aortic aneurysm after endovascidar graft placement and aneurysm size reduction
    • Alimi, Y. S., Chakfe, N., Rivoal, E., Slimane, K. K., Valerio, N., Riepe, G., Kretz, J. G., and Juhan, C. Rupture of an abdominal aortic aneurysm after endovascidar graft placement and aneurysm size reduction. J. Vascular Surg., 1998, 28, 178-183.
    • (1998) J. Vascular Surg , vol.28 , pp. 178-183
    • Alimi, Y.S.1    Chakfe, N.2    Rivoal, E.3    Slimane, K.K.4    Valerio, N.5    Riepe, G.6    Kretz, J.G.7    Juhan, C.8
  • 9
    • 0031820342 scopus 로고    scopus 로고
    • Rupture of abdominal aortic aneurysm previously treated by endovascular stent graft
    • Torsello, G. B., Klenk, E., Kasprzak, B., and Umscheid, T. Rupture of abdominal aortic aneurysm previously treated by endovascular stent graft. J. Vascular Surg., 1998, 28, 184-187.
    • (1998) J. Vascular Surg , vol.28 , pp. 184-187
    • Torsello, G.B.1    Klenk, E.2    Kasprzak, B.3    Umscheid, T.4
  • 11
    • 2542490236 scopus 로고    scopus 로고
    • A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)
    • Morris, L., Delassus, P., Walsh, M., and McGloughlin, T. A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA). J. Biomechanics, 2004, 37, 1087-1095.
    • (2004) J. Biomechanics , vol.37 , pp. 1087-1095
    • Morris, L.1    Delassus, P.2    Walsh, M.3    McGloughlin, T.4
  • 12
    • 33747138280 scopus 로고    scopus 로고
    • Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model
    • Li, Z. and Kleinstreuer, C. Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model. J. Biomechanics, 2006, 39, 2264-2273.
    • (2006) J. Biomechanics , vol.39 , pp. 2264-2273
    • Li, Z.1    Kleinstreuer, C.2
  • 13
    • 34447290302 scopus 로고    scopus 로고
    • Fluid-structure interaction analyses of stented abdominal aortic aneurysms
    • Kleinstreuer, C., Li, Z., and Farber, M. A. Fluid-structure interaction analyses of stented abdominal aortic aneurysms. A. Rev. Biomed. Engng, 2007, 9, 169-204.
    • (2007) A. Rev. Biomed. Engng , vol.9 , pp. 169-204
    • Kleinstreuer, C.1    Li, Z.2    Farber, M.A.3
  • 15
    • 0344897143 scopus 로고    scopus 로고
    • Factors affecting the displacement force exerted on a stent graft after AAA repair - an in vitro study
    • Volodos, S. M., Sayers, R. D., Gostelow, J. P., and Bell, P. Factors affecting the displacement force exerted on a stent graft after AAA repair - an in vitro study. Eur. J. Vascular Endovascular Surg., 2003, 26, 596-601.
    • (2003) Eur. J. Vascular Endovascular Surg , vol.26 , pp. 596-601
    • Volodos, S.M.1    Sayers, R.D.2    Gostelow, J.P.3    Bell, P.4
  • 16
    • 17444423230 scopus 로고    scopus 로고
    • Experimental force measurements on a bifurcated endoluminal stent graft model: Comparison with theory
    • Sutalo, I. D., Liffman, K., Lawrence-Brown, M. M. D., and Semmens, J. B. Experimental force measurements on a bifurcated endoluminal stent graft model: comparison with theory. Vascular, 2005, 13, 98-106.
    • (2005) Vascular , vol.13 , pp. 98-106
    • Sutalo, I.D.1    Liffman, K.2    Lawrence-Brown, M.M.D.3    Semmens, J.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.