메뉴 건너뛰기




Volumn 12, Issue 4, 2005, Pages 435-445

Flow visualization in a model of a bifurcated stent-graft

Author keywords

Abdominal aortic aneurysm; Bifurcated stent graft; Experimental model; Flow pattern; Hemodynamics; Kinking; Thrombosis

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ACCELERATION; ANEURYSM SURGERY; AORTA GRAFT; ARTICLE; DECELERATION; EXPERIMENTAL MODEL; HEMODYNAMICS; LIMB; PRIORITY JOURNAL; PULSATILE FLOW; STENT; TRUNK;

EID: 23344433873     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/04-1465.1     Document Type: Article
Times cited : (30)

References (27)
  • 1
    • 0033668254 scopus 로고    scopus 로고
    • Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate-term follow-up results of a European collaborative registry (EUROSTAR)
    • Laheij RJ, Buth J, Harris PL, et al. Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate-term follow-up results of a European collaborative registry (EUROSTAR). Br J Surg. 2000;87: 1666-1673.
    • (2000) Br J Surg , vol.87 , pp. 1666-1673
    • Laheij, R.J.1    Buth, J.2    Harris, P.L.3
  • 2
    • 0033011499 scopus 로고    scopus 로고
    • Immediate and late explantation of endovascular aortic grafts: The Endovascular Technologies experience
    • Jacobowitz GR, Lee AM, Riles TS. Immediate and late explantation of endovascular aortic grafts: the Endovascular Technologies experience. J Vasc Surg. 1999;29:309-316.
    • (1999) J Vasc Surg , vol.29 , pp. 309-316
    • Jacobowitz, G.R.1    Lee, A.M.2    Riles, T.S.3
  • 3
    • 0037696294 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms: Device-specific outcome
    • Ouriel K, Clair DG, Greenberg RK, et al. Endovascular repair of abdominal aortic aneurysms: device-specific outcome. J Vasc Surg. 2003;37: 991-998.
    • (2003) J Vasc Surg , vol.37 , pp. 991-998
    • Ouriel, K.1    Clair, D.G.2    Greenberg, R.K.3
  • 4
    • 0038034214 scopus 로고    scopus 로고
    • Nature, frequency, and predictors of secondary procedures after endovascular repair of abdominal aortic aneurysm
    • Sampram ES, Karafa MT, Mascha EJ, et al. Nature, frequency, and predictors of secondary procedures after endovascular repair of abdominal aortic aneurysm. J Vasc Surg. 2003;37: 930-937.
    • (2003) J Vasc Surg , vol.37 , pp. 930-937
    • Sampram, E.S.1    Karafa, M.T.2    Mascha, E.J.3
  • 5
    • 0031011654 scopus 로고    scopus 로고
    • Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: Complications and secondary radiologic intervention
    • Dorffner R, Thurnher S, Polterauer P, et al. Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. Radiology. 1997;204:79-86.
    • (1997) Radiology , vol.204 , pp. 79-86
    • Dorffner, R.1    Thurnher, S.2    Polterauer, P.3
  • 6
    • 0034862835 scopus 로고    scopus 로고
    • Thrombus formation in aortic endografts
    • Wegener M, Görich J, Krämer S, et al. Thrombus formation in aortic endografts. J Endovasc Ther. 2001;8:372-379.
    • (2001) J Endovasc Ther , vol.8 , pp. 372-379
    • Wegener, M.1    Görich, J.2    Krämer, S.3
  • 7
    • 0035099062 scopus 로고    scopus 로고
    • Failure of endovascular abdominal aortic aneurysm graft limbs
    • Carpenter JP, Neschis DG, Fairman RM, et al. Failure of endovascular abdominal aortic aneurysm graft limbs. J Vasc Surg. 2001;33:296-303.
    • (2001) J Vasc Surg , vol.33 , pp. 296-303
    • Carpenter, J.P.1    Neschis, D.G.2    Fairman, R.M.3
  • 8
    • 0033708764 scopus 로고    scopus 로고
    • Graft distortion after endovascular repair of abdominal aortic aneurysm: Association with sac morphology and mid-term complications
    • Gould DA, Edwards RD, McWilliams RG, et al. Graft distortion after endovascular repair of abdominal aortic aneurysm: association with sac morphology and mid-term complications. Cardiovasc Intervent Radiol. 2000;23:358-363.
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 358-363
    • Gould, D.A.1    Edwards, R.D.2    McWilliams, R.G.3
  • 9
    • 0032992669 scopus 로고    scopus 로고
    • Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: A source of intermediate and late complications
    • Harris P, Brennan J, Martin J, et al. Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: a source of intermediate and late complications. J Endovasc Surg. 1999;6:11-16.
    • (1999) J Endovasc Surg , vol.6 , pp. 11-16
    • Harris, P.1    Brennan, J.2    Martin, J.3
  • 10
    • 0031453479 scopus 로고    scopus 로고
    • Three-year experience with modular stent-graft devices for endovascular AAA treatment
    • Stelter W, Umscheid T, Ziegler P. Three-year experience with modular stent-graft devices for endovascular AAA treatment. J Endovasc Surg. 1997;4:362-369.
    • (1997) J Endovasc Surg , vol.4 , pp. 362-369
    • Stelter, W.1    Umscheid, T.2    Ziegler, P.3
  • 11
    • 0028970406 scopus 로고
    • Flow instabilities induced by coronary artery stents: Assessment with an in vitro pulse duplicator
    • Peacock J, Hankins S, Jones T, et al. Flow instabilities induced by coronary artery stents: assessment with an in vitro pulse duplicator. J Biomech. 1995;28:17-26.
    • (1995) J Biomech , vol.28 , pp. 17-26
    • Peacock, J.1    Hankins, S.2    Jones, T.3
  • 12
    • 0033560955 scopus 로고    scopus 로고
    • Influence of stent length and heparin coating on platelet activation: A flow cytometric analysis in a pulsed floating model
    • Beythien C, Gutensohn K, Bau J, et al. Influence of stent length and heparin coating on platelet activation: a flow cytometric analysis in a pulsed floating model. Thromb Res. 1999; 94:79-86.
    • (1999) Thromb Res , vol.94 , pp. 79-86
    • Beythien, C.1    Gutensohn, K.2    Bau, J.3
  • 13
    • 0020687089 scopus 로고
    • Arterial geometry affects hemodynamics. A potential risk factor for atherosclerosis
    • Friedman MH, Deters OJ, Mark FF, et al. Arterial geometry affects hemodynamics. A potential risk factor for atherosclerosis. Atherosclerosis. 1983;46:225-231.
    • (1983) Atherosclerosis , vol.46 , pp. 225-231
    • Friedman, M.H.1    Deters, O.J.2    Mark, F.F.3
  • 14
    • 0032689667 scopus 로고    scopus 로고
    • Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics
    • Chong CK, Rowe CS, Sivanesan S, et al. Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics. Proc Inst Mech Eng [H]. 1999;213:1-4.
    • (1999) Proc Inst Mech Eng [H] , vol.213 , pp. 1-4
    • Chong, C.K.1    Rowe, C.S.2    Sivanesan, S.3
  • 15
    • 0028485305 scopus 로고
    • Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions
    • Moore JE, Ku DN. Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions. J Biomech Eng. 1994;116:337-346.
    • (1994) J Biomech Eng , vol.116 , pp. 337-346
    • Moore, J.E.1    Ku, D.N.2
  • 16
    • 0028484474 scopus 로고
    • Influence of abdominal aortic curvature and resting versus exercise conditions on velocity fields in the normal abdominal aortic bifurcation
    • Pedersen EM, Sung HW, Yoganathan AP. Influence of abdominal aortic curvature and resting versus exercise conditions on velocity fields in the normal abdominal aortic bifurcation. J Biomech Eng. 1994;116:347-354.
    • (1994) J Biomech Eng , vol.116 , pp. 347-354
    • Pedersen, E.M.1    Sung, H.W.2    Yoganathan, A.P.3
  • 17
    • 0002762220 scopus 로고
    • Fluid dynamic and hemorheologic considerations
    • Slack SM, Turitto VT. Fluid dynamic and hemorheologic considerations. Cardiovasc Pathol. 1993;2:S11-S21.
    • (1993) Cardiovasc Pathol , vol.2
    • Slack, S.M.1    Turitto, V.T.2
  • 18
    • 0032535203 scopus 로고    scopus 로고
    • Mechanical factors affecting hemostasis and thrombosis
    • Turitto VT, Hall CL. Mechanical factors affecting hemostasis and thrombosis. Thromb Res. 1998;92:S25-31.
    • (1998) Thromb Res , vol.92
    • Turitto, V.T.1    Hall, C.L.2
  • 19
    • 0034177656 scopus 로고    scopus 로고
    • Vortex shedding as a mechanism for free emboli formation in mechanical heart valves
    • Bluestein D, Rambod E, Gharib M. Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. J Biomech Eng. 2000;122:125-134.
    • (2000) J Biomech Eng , vol.122 , pp. 125-134
    • Bluestein, D.1    Rambod, E.2    Gharib, M.3
  • 20
    • 1642336911 scopus 로고    scopus 로고
    • Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: A note of caution based on a 9-year experience
    • Ohki T, Veith FJ, Shaw P, et al. Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience. Ann Surg. 2001;234:323-335.
    • (2001) Ann Surg , vol.234 , pp. 323-335
    • Ohki, T.1    Veith, F.J.2    Shaw, P.3
  • 21
    • 0347364768 scopus 로고    scopus 로고
    • Frequency, predictive factors, and consequences of stent-graft kink following endovascular AAA repair
    • Fransen GA, Desgranges P, Harris PL, et al. Frequency, predictive factors, and consequences of stent-graft kink following endovascular AAA repair. J Endovasc Ther. 2003;10:913-918.
    • (2003) J Endovasc Ther , vol.10 , pp. 913-918
    • Fransen, G.A.1    Desgranges, P.2    Harris, P.L.3
  • 22
    • 0033929547 scopus 로고    scopus 로고
    • Mid-term results of endovascular versus open repair of abdominal aortic aneurysm in patients anatomically suitable for endovascular repair
    • Becquemin JP, Bourriez A, d'Audiffret A, et al. Mid-term results of endovascular versus open repair of abdominal aortic aneurysm in patients anatomically suitable for endovascular repair. Eur J Vasc Endovasc Surg. 2000;19:656-661.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 656-661
    • Becquemin, J.P.1    Bourriez, A.2    D'Audiffret, A.3
  • 23
    • 0033066095 scopus 로고    scopus 로고
    • Time-related alterations of shape, position, and structure in self-expanding modular aortic stent-grafts
    • Umscheid T, Stelter WJ. Time-related alterations of shape, position, and structure in self-expanding modular aortic stent-grafts. J Endovasc Surg. 1999;6:17-32.
    • (1999) J Endovasc Surg , vol.6 , pp. 17-32
    • Umscheid, T.1    Stelter, W.J.2
  • 24
    • 0036547006 scopus 로고    scopus 로고
    • Endograft limb occlusion and stenosis after ANCURE endovascular abdominal aortic aneurysm repair
    • Parent FN, Godziachville V, Meier GH, et al. Endograft limb occlusion and stenosis after ANCURE endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2002;35:686-690.
    • (2002) J Vasc Surg , vol.35 , pp. 686-690
    • Parent, F.N.1    Godziachville, V.2    Meier, G.H.3
  • 25
    • 0035140201 scopus 로고    scopus 로고
    • Geometric changes in aortic endografts over a 2-year observation period
    • Krämer SC, Seifarth H, Pamler R, et al. Geometric changes in aortic endografts over a 2-year observation period. J Endovasc Ther. 2001;8:34-38.
    • (2001) J Endovasc Ther , vol.8 , pp. 34-38
    • Krämer, S.C.1    Seifarth, H.2    Pamler, R.3
  • 26
    • 0037497404 scopus 로고    scopus 로고
    • Abdominal aortic hemodynamic conditions in healthy subjects aged 50-70 at rest and during lower limb exercise: In vivo quantification using MRI
    • Cheng CP, Herfkens RJ, Taylor CA. Abdominal aortic hemodynamic conditions in healthy subjects aged 50-70 at rest and during lower limb exercise: in vivo quantification using MRI. Atherosclerosis. 2003;168:323-331.
    • (2003) Atherosclerosis , vol.168 , pp. 323-331
    • Cheng, C.P.1    Herfkens, R.J.2    Taylor, C.A.3
  • 27
    • 0033133580 scopus 로고    scopus 로고
    • Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise
    • Pedersen EM, Kozerke S, Ringgaard S, et al. Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise. Magn Reson Imaging. 1999;17:489-494.
    • (1999) Magn Reson Imaging , vol.17 , pp. 489-494
    • Pedersen, E.M.1    Kozerke, S.2    Ringgaard, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.