메뉴 건너뛰기




Volumn 23, Issue 2, 2010, Pages 239-245

Use of echocardiography and modalities of patient monitoring of trauma patients

Author keywords

Echocardiography; ICU monitoring; Trauma

Indexed keywords

ARTERY CATHETERIZATION; ARTIFICIAL VENTILATION; BLOOD FLOW VELOCITY; BLOOD PRESSURE MEASUREMENT; CENTRAL VENOUS PRESSURE; COMPUTER ASSISTED TOMOGRAPHY; CRITICALLY ILL PATIENT; DIAGNOSTIC VALUE; DISEASE CLASSIFICATION; DOPPLER ECHOCARDIOGRAPHY; EARLY DIAGNOSIS; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; INJURY; INTENSIVE CARE; INTENSIVE CARE UNIT; NON INVASIVE MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT ASSESSMENT; PATIENT MONITORING; POSTOPERATIVE CARE; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; PULSE OXIMETRY; REVIEW; THORAX BLUNT TRAUMA; THORAX INJURY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; VENOUS BLOOD;

EID: 77952218158     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/ACO.0b013e328335f007     Document Type: Review
Times cited : (17)

References (57)
  • 1
    • 50349098694 scopus 로고    scopus 로고
    • Ultrasound in the surgical intensive care unit
    • Nice review of bedside ultrasound modalities in the ICU
    • Guillroy RK, Gunter OL. Ultrasound in the surgical intensive care unit. Curr •• Opin Crit Care 2008;14:415-422. Nice review of bedside ultrasound modalities in the ICU.
    • (2008) Curr. •• Opin. Crit. Care , vol.14 , pp. 415-422
    • Guillroy, R.K.1    Gunter, O.L.2
  • 3
    • 0041784903 scopus 로고    scopus 로고
    • ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: Summary article-A report of the American College of Cardiology/American Heart Association/Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
    • Cheitlin MD, Armstrong WF, Aurigemma GP, et al. ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article-A report of the American College of Cardiology/American Heart Association/Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography). Circulation 2003;108:1146-1162.
    • (2003) Circulation , vol.108 , pp. 1146-1162
    • Cheitlin, M.D.1    Armstrong, W.F.2    Aurigemma, G.P.3
  • 4
    • 55349099522 scopus 로고    scopus 로고
    • Hemodynamic monitoring by echocardio- •• graphy in the ICU: The role of the new echo techniques
    • Nice overview of echocardiography in the ICU
    • Salem R, Vallee F, Rusca M, et al. Hemodynamic monitoring by echocardio- •• graphy in the ICU: the role of the new echo techniques. Curr Opin Crit Care 2008;14:561-568. Nice overview of echocardiography in the ICU.
    • (2008) Curr. Opin. Crit. Care , vol.14 , pp. 561-568
    • Salem, R.1    Vallee, F.2    Rusca, M.3
  • 5
    • 64749098476 scopus 로고    scopus 로고
    • American College of Chest Physicians/La Société de Réanimation de Langue Francaise Statement on Competence in Critical Care Ultrasonography: Consensus Statement
    • Mayo PH, Beaulieu Y, Doelken P, et al. American College of Chest Physicians/La Société de Réanimation de Langue Francaise Statement on Competence in Critical Care Ultrasonography: Consensus Statement. Chest 2009;135:1050-1060.
    • (2009) Chest , vol.135 , pp. 1050-1060
    • Mayo, P.H.1    Beaulieu, Y.2    Doelken, P.3
  • 6
    • 61349083772 scopus 로고    scopus 로고
    • History of technology in the intensive care unit
    • •, Nice historical perspective of critical care monitoring
    • Puri N, Puri V, Dellinger RP. History of technology in the intensive care unit. • Crit Care Clin 2009;25:185-200. Nice historical perspective of critical care monitoring.
    • (2009) Crit. Care Clin. , vol.25 , pp. 185-200
    • Puri, N.1    Puri, V.2    Dellinger, R.P.3
  • 7
    • 47749134846 scopus 로고    scopus 로고
    • Blunt cardiac trauma
    • Good description of thoracic trauma •
    • El-Chami MF, Nicholson W, Helmy T. Blunt cardiac trauma. J Emerg Med • 2008;35:127-133. Good description of thoracic trauma.
    • (2008) J. Emerg. Med. , vol.35 , pp. 127-133
    • El-Chami, M.F.1    Nicholson, W.2    Helmy, T.3
  • 8
    • 34447343375 scopus 로고    scopus 로고
    • The use of current hemodynamic monitors and echocardiography in resuscitation of the critically ill or injured patient
    • Josephs SA. The use of current hemodynamic monitors and echocardiography in resuscitation of the critically ill or injured patient. Int Anesthesiol Clin 2007;45:31-59.
    • (2007) Int. Anesthesiol Clin. , vol.45 , pp. 31-59
    • Josephs, S.A.1
  • 9
    • 0027321837 scopus 로고
    • Usefulness of transesophageal echocardiography in the treatment of critically ill patients
    • Hwang JJ, Shyu KG, Chen JJ, et al. Usefulness of transesophageal echocardiography in the treatment of critically ill patients. Chest 1993;104:861-866.
    • (1993) Chest , vol.104 , pp. 861-866
    • Hwang, J.J.1    Shyu, K.G.2    Chen, J.J.3
  • 10
    • 0036250831 scopus 로고    scopus 로고
    • Transesophageal echocardiography in critically ill patients
    • Colreavy FB, Donovan K, Lee KY, et al. Transesophageal echocardiography in critically ill patients. Crit Care Med 2002;30:989-996.
    • (2002) Crit. Care Med. , vol.30 , pp. 989-996
    • Colreavy, F.B.1    Donovan, K.2    Lee, K.Y.3
  • 11
    • 0025246250 scopus 로고
    • Safety and utility of transesophageal echocardiography in the critically ill patient
    • Pearson AC, Castello R, Labovitz AJ. Safety and utility of transesophageal echocardiography in the critically ill patient. Am Heart J 1990;119:1083-1089.
    • (1990) Am. Heart J. , vol.119 , pp. 1083-1089
    • Pearson, A.C.1    Castello, R.2    Labovitz, A.J.3
  • 12
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, et al. Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007;99:343-348.
    • (2007) Br. J. Anaesth. , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3
  • 13
    • 34447107351 scopus 로고    scopus 로고
    • Sonographic measurement of the inferior vena cava as a predictor of shock in trauma patients
    • Sefidbakht S, Assadsangabi R, Abbasi HR, et al. Sonographic measurement of the inferior vena cava as a predictor of shock in trauma patients. Emerg Radiol 2007;14:181-185.
    • (2007) Emerg. Radiol. , vol.14 , pp. 181-185
    • Sefidbakht, S.1    Assadsangabi, R.2    Abbasi, H.R.3
  • 14
    • 4644223327 scopus 로고    scopus 로고
    • Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
    • Viellard-Baron A, Chergui K, Rabiller A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 2004;30:1734-1739.
    • (2004) Intensive Care Med. , vol.30 , pp. 1734-1739
    • Viellard-Baron, A.1    Chergui, K.2    Rabiller, A.3
  • 16
    • 34547659040 scopus 로고    scopus 로고
    • Echocardiography for management of hypotension in the intensive care unit
    • Subramaniam B, Talmor D. Echocardiography for management of hypotension in the intensive care unit. Crit Care Med 2007;35(8 Suppl): S401 -S407.
    • (2007) Crit. Care Med. , vol.35 , Issue.8 SUPPL.
    • Subramaniam, B.1    Talmor, D.2
  • 17
    • 0028100054 scopus 로고
    • Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function
    • Cheung AT, Savino JS, Weiss SJ, et al. Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function. Anesthesiology 1994;81:376-387.
    • (1994) Anesthesiology , vol.81 , pp. 376-387
    • Cheung, A.T.1    Savino, J.S.2    Weiss, S.J.3
  • 18
    • 74049133364 scopus 로고    scopus 로고
    • Left ventricular end-diastolic area is a measure of cardiac preload in patients with early septic shock
    • Scheuren K, Wente MN, HainerC, et al. Left ventricular end-diastolic area is a measure of cardiac preload in patients with early septic shock. Eur J Anaesthesiol 2009;26:759-765.
    • (2009) Eur. J. Anaesthesiol , vol.26 , pp. 759-765
    • Scheuren, K.1    Wente, M.N.2    HainerC3
  • 19
    • 33846871748 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients
    • Cannesson M, Slieker J, Desebbe O, et al. Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients. Crit Care 2006;10: R171.
    • (2006) Crit. Care , vol.10
    • Cannesson, M.1    Slieker, J.2    Desebbe, O.3
  • 20
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • Feissel M, Michard F, Faller JP, et al. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004;30:1834-1837.
    • (2004) Intensive Care Med. , vol.30 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3
  • 21
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • Barbier C, Loubieres Y, Schmit C, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004;30:1740-1746.
    • (2004) Intensive Care Med. , vol.30 , pp. 1740-1746
    • Barbier, C.1    Loubieres, Y.2    Schmit, C.3
  • 22
    • 8744306052 scopus 로고    scopus 로고
    • Transthoracic echocardiography to identify or exclude cardiac cause of shock
    • Joseph MX, Disney PJ, Da Costa R, et al. Transthoracic echocardiography to identify or exclude cardiac cause of shock. Chest 2004;126:1592-1597.
    • (2004) Chest , vol.126 , pp. 1592-1597
    • Joseph, M.X.1    Disney, P.J.2    Costa, R.D.3
  • 23
    • 67650317474 scopus 로고    scopus 로고
    • Accuracy of cardiac function and • volume status estimates using the bedside echocardiographic assessment in trauma/critical care
    • Nice comparison between TTE and PAC
    • Gunst M, Ghaemmaghami V, Sperry J, et al. Accuracy of cardiac function and • volume status estimates using the bedside echocardiographic assessment in trauma/critical care. J Trauma 2008;65:509-516. Nice comparison between TTE and PAC.
    • (2008) J. Trauma. , vol.65 , pp. 509-516
    • Gunst, M.1    Ghaemmaghami, V.2    Sperry, J.3
  • 24
    • 0037220333 scopus 로고    scopus 로고
    • Echocardiographic monitoring during induction of general anesthesia with a miniaturized esophageal probe
    • Zimmermann P, Greim C, Trautner H, et al. Echocardiographic monitoring during induction of general anesthesia with a miniaturized esophageal probe. Anesth Analg 2003;96:21-27.
    • (2003) Anesth. Analg. , vol.96 , pp. 21-27
    • Zimmermann, P.1    Greim, C.2    Trautner, H.3
  • 25
    • 0032713233 scopus 로고    scopus 로고
    • Multicenter experience using anew prototype transnasal transesophageal echocardiography probe
    • Spencer KT, Goldman M, Cholley B, et al. Multicenter experience using anew prototype transnasal transesophageal echocardiography probe. Echocardiography 1999;16:811-817.
    • (1999) Echocardiography , vol.16 , pp. 811-817
    • Spencer, K.T.1    Goldman, M.2    Cholley, B.3
  • 27
    • 0032959935 scopus 로고    scopus 로고
    • Transnasal transesophageal echocardiography: A modified application mode for cardiac examination in ventilated patients
    • Greim CA, Brederlau J, Kraus I, et al. Transnasal transesophageal echocardiography: a modified application mode for cardiac examination in ventilated patients. Anesth Analg 1999;88:306-311.
    • (1999) Anesth. Analg. , vol.88 , pp. 306-311
    • Greim, C.A.1    Brederlau, J.2    Kraus, I.3
  • 28
    • 43449086396 scopus 로고    scopus 로고
    • Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity
    • Teboul JL, Monnet X. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care 2008;14:334-339.
    • (2008) Curr. Opin. Crit. Care , vol.14 , pp. 334-339
    • Teboul, J.L.1    Monnet, X.2
  • 30
    • 0028832433 scopus 로고
    • Use of echocardiography to detect occult cardiac injury after penetrating thoracic trauma: A prospective study
    • Meyer D, Jessen M, Grayburn P. Use of echocardiography to detect occult cardiac injury after penetrating thoracic trauma: a prospective study. J Trauma 1995;39:902-909.
    • (1995) J. Trauma. , vol.39 , pp. 902-909
    • Meyer, D.1    Jessen, M.2    Grayburn, P.3
  • 32
    • 67650317664 scopus 로고    scopus 로고
    • Diagnosis and treatment of blunt thoracic aortic injuries: Changing perspectives
    • Demetriades D, Velmahos GC, Scalea TM, et al. Diagnosis and treatment of blunt thoracic aortic injuries: changing perspectives. J Trauma 2008;64:1418-1419.
    • (2008) J. Trauma. , vol.64 , pp. 1418-1419
    • Demetriades, D.1    Velmahos, G.C.2    Scalea, T.M.3
  • 33
    • 67649664051 scopus 로고    scopus 로고
    • Tension hemomediastinum secondary to blunt chest trauma in a patient with an anomalous manubrial-sternal junction
    • Marinaro J, Zwehl-Burke S, McAnally J, et al. Tension hemomediastinum secondary to blunt chest trauma in a patient with an anomalous manubrial-sternal junction. J Trauma 2009;66:1489-1491.
    • (2009) J. Trauma. , vol.66 , pp. 1489-1491
    • Marinaro, J.1    Zwehl-Burke, S.2    McAnally, J.3
  • 35
    • 34247323551 scopus 로고    scopus 로고
    • Ultrasound in the management of thoracic disease
    • Lichtenstein D. Ultrasound in the management of thoracic disease. Crit Care Med 2007;35: S250-261.
    • (2007) Crit. Care Med. , vol.35
    • Lichtenstein, D.1
  • 36
    • 67650166170 scopus 로고    scopus 로고
    • Lung ultrasound in acute respiratoryfailure, an introduction to • the BLUE protocol
    • Succinct description of focused pulmonary ultrasound
    • Lichtenstein D. Lung ultrasound in acute respiratoryfailure, an introduction to • the BLUE protocol. Minerva Anestesiol 2009;75:313-317. Succinct description of focused pulmonary ultrasound.
    • (2009) Minerva Anestesiol , vol.75 , pp. 313-317
    • Lichtenstein, D.1
  • 37
    • 41849093333 scopus 로고    scopus 로고
    • Physiological and medical monitoring for en route care of combat casualties
    • Convertino VA, Ryan KL, Rickards CA, et al. Physiological and medical monitoring for en route care of combat casualties. J Trauma 2008;64(4 Suppl): S342-S435.
    • (2008) J. Trauma. , vol.64 , Issue.4 SUPPL.
    • Convertino, V.A.1    Ryan, K.L.2    Rickards, C.A.3
  • 38
    • 17044421757 scopus 로고    scopus 로고
    • Increasing mean arterial pressure in patients with septic shock: Effects on oxygen variables and renal function
    • Bourgoin A, Leone M, Delmas A, et al. Increasing mean arterial pressure in patients with septic shock: effects on oxygen variables and renal function. Crit Care Med 2005;33:780-786.
    • (2005) Crit. Care Med. , vol.33 , pp. 780-786
    • Bourgoin, A.1    Leone, M.2    Delmas, A.3
  • 39
    • 13144250217 scopus 로고    scopus 로고
    • Goal-directed transesophageal echocardiography performed by intensivists to assess left ventricular function: Comparison with pulmonary artery catheterization
    • Benjamin E, Griffin K, Leibowitz AB, et al. Goal-directed transesophageal echocardiography performed by intensivists to assess left ventricular function: comparison with pulmonary artery catheterization. J Cardiothorac Vasc Anesth 1998;12:10-15.
    • (1998) J. Cardiothorac. Vasc. Anesth. , vol.12 , pp. 10-15
    • Benjamin, E.1    Griffin, K.2    Leibowitz, A.B.3
  • 40
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005;366:472-477.
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 41
    • 45149088162 scopus 로고    scopus 로고
    • Post hoc insights from PAC-Man: The U. K. pulmonary artery catheter trial
    • Harvey SE, Welch CA, Harrison DA, et al. Post hoc insights from PAC-Man: the U. K. pulmonary artery catheter trial. Crit Care Med 2008;36:1714-1721.
    • (2008) Crit. Care Med. , vol.36 , pp. 1714-1721
    • Harvey, S.E.1    Welch, C.A.2    Harrison, D.A.3
  • 42
    • 38349075756 scopus 로고    scopus 로고
    • Cardiac output monitoring: Basic science and •• clinical application
    • An excellent review of cardiac profile monitoring modalities
    • Jhanji S, Dawson J, Pearse RM. Cardiac output monitoring: basic science and •• clinical application. Anaesthesia 2008;63:172-181. An excellent review of cardiac profile monitoring modalities.
    • (2008) Anaesthesia , vol.63 , pp. 172-181
    • Jhanji, S.1    Dawson, J.2    Pearse, R.M.3
  • 44
    • 56049102361 scopus 로고    scopus 로고
    • The pulmonary artery catheter: In • medio virtus
    • Nice discussion regarding PAC and its use
    • Vincent JL, Pinsky MR, Sprung CL, et al. The pulmonary artery catheter: in • medio virtus. Crit Care Med 2008;36:3093-3096. Nice discussion regarding PAC and its use.
    • (2008) Crit. Care Med. , vol.36 , pp. 3093-3096
    • Vincent, J.L.1    Pinsky, M.R.2    Sprung, C.L.3
  • 45
    • 34447642740 scopus 로고    scopus 로고
    • Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability
    • Johansson A, Chew M. Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability. J Clin Monit Comput 2007;21:237-242.
    • (2007) J. Clin. Monit. Comput. , vol.21 , pp. 237-242
    • Johansson, A.1    Chew, M.2
  • 46
    • 0037407062 scopus 로고    scopus 로고
    • Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
    • Wiesnack C, Prasser C, Rodig G, et al. Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients. Anesth Analg 2003;96:1254-1257.
    • (2003) Anesth. Analg. , vol.96 , pp. 1254-1257
    • Wiesnack, C.1    Prasser, C.2    Rodig, G.3
  • 47
    • 62549094807 scopus 로고    scopus 로고
    • Comparison of two versions of the Vigileo-FloTrac system (1.03 and 1.07) for stroke volume estimation: A multicentre, blinded comparison with oesophageal Doppler measurements
    • Chatti R, de Rudniki S, Marque S, et al. Comparison of two versions of the Vigileo-FloTrac system (1.03 and 1.07) for stroke volume estimation: a multicentre, blinded comparison with oesophageal Doppler measurements. Br J Anaesth 2009;102:463-469.
    • (2009) Br. J. Anaesth. , vol.102 , pp. 463-469
    • Chatti, R.1    De Rudniki, S.2    Marque, S.3
  • 48
    • 44149121240 scopus 로고    scopus 로고
    • The accuracy of the Vigileo/FloTrac continuous cardiac output monitor
    • Zimmermann A, Kufner C, Hofbauer S, et al. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor. J Cardiothorac Vasc Anesth 2008;22:388-393.
    • (2008) J. Cardiothorac. Vasc. Anesth. , vol.22 , pp. 388-393
    • Zimmermann, A.1    Kufner, C.2    Hofbauer, S.3
  • 49
    • 2942564478 scopus 로고    scopus 로고
    • Equipment review: An appraisal of the LiDCOplus method of measuring cardiac output
    • Pearse RM, Ikram K, Barry J. Equipment review: an appraisal of the LiDCOplus method of measuring cardiac output. Crit Care 2004;8:190-195.
    • (2004) Crit. Care , vol.8 , pp. 190-195
    • Pearse, R.M.1    Ikram, K.2    Barry, J.3
  • 50
    • 38849093827 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery cathetervs. lithium dilution technique
    • Costa MG, Della Rocca G, Chiarandini P, et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery cathetervs. lithium dilution technique. Intensive Care Med 2008;34:257-263.
    • (2008) Intensive Care Med. , vol.34 , pp. 257-263
    • Costa, M.G.1    Rocca, G.D.2    Chiarandini, P.3
  • 51
    • 60449102439 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique
    • Cecconi M, Dawson D, Grounds RM, et al. Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009;35:498-504.
    • (2009) Intensive Care Med. , vol.35 , pp. 498-504
    • Cecconi, M.1    Dawson, D.2    Grounds, R.M.3
  • 52
    • 34248163905 scopus 로고    scopus 로고
    • Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: A randomized controlled trial
    • Chytra I, Pradl R, Bosman R, et al. Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: a randomized controlled trial. Crit Care 2007;11: R24.
    • (2007) Crit. Care , vol.11
    • Chytra, I.1    Pradl, R.2    Bosman, R.3
  • 53
    • 57449089143 scopus 로고    scopus 로고
    • Noninvasive Doppler ultrasonography for assessing cardiac function: Can it replace the Swan-Ganz catheter?
    • Jain S, Allins A, Salim A, et al. Noninvasive Doppler ultrasonography for assessing cardiac function: can it replace the Swan-Ganz catheter? Am J Surg 2008;196:961-968.
    • (2008) Am. J. Surg. , vol.196 , pp. 961-968
    • Jain, S.1    Allins, A.2    Salim, A.3
  • 54
    • 61949421084 scopus 로고    scopus 로고
    • Noninvasive cardiac output measurement in heart failure subjects on circulatory support
    • Phillips R, Lichenthal P, Sloniger J, et al. Noninvasive cardiac output measurement in heart failure subjects on circulatory support. Anesth Analg 2009;108:881-886.
    • (2009) Anesth. Analg. , vol.108 , pp. 881-886
    • Phillips, R.1    Lichenthal, P.2    Sloniger, J.3
  • 56
    • 42449084898 scopus 로고    scopus 로고
    • What type of monitoring has been shown to improve outcomes in acutely ill patients?
    • Ospina-Tascon GA, Cordioli RL, Vincent JL. What type of monitoring has been shown to improve outcomes in acutely ill patients? Intensive Care Med 2008;34:800-820.
    • (2008) Intensive Care Med. , vol.34 , pp. 800-820
    • Ospina-Tascon, G.A.1    Cordioli, R.L.2    Vincent, J.L.3
  • 57
    • 34548840519 scopus 로고    scopus 로고
    • Multimodality monitoring in neuro- •• critical care
    • Good review and description of neurocritical care monitoring modalities
    • Wartenberg KE, Schmidt JM, Mayer SA. Multimodality monitoring in neuro- •• critical care. Crit Care Clin 2007;23:507-538. Good review and description of neurocritical care monitoring modalities.
    • (2007) Crit. Care Clin. , vol.23 , pp. 507-538
    • Wartenberg, K.E.1    Schmidt, J.M.2    Mayer, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.