메뉴 건너뛰기




Volumn 196, Issue 6, 2008, Pages 961-968

Noninvasive Doppler ultrasonography for assessing cardiac function: can it replace the Swan-Ganz catheter?

Author keywords

Cardiac function; Cardiac index; Doppler ultrasound; Noninvasive; Pulmonary artery catheter

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CRITICALLY ILL PATIENT; DEVICE; DIAGNOSTIC ACCURACY; DOPPLER ECHOCARDIOGRAPHY; FEMALE; HEART FUNCTION; HEART INDEX; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; LUNG ARTERY CATHETER; MALE; NON INVASIVE PROCEDURE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SURGICAL PATIENT; ULTRASOUND;

EID: 57449089143     PISSN: 00029610     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjsurg.2008.07.039     Document Type: Article
Times cited : (24)

References (29)
  • 1
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham J.D., Hull R.D., Brant R.F., et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 348 (2003) 5-14
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 2
    • 26044478155 scopus 로고    scopus 로고
    • Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials
    • Shah M.R., Hasselblad V., Stevenson L.W., et al. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 294 (2005) 1664-1670
    • (2005) JAMA , vol.294 , pp. 1664-1670
    • Shah, M.R.1    Hasselblad, V.2    Stevenson, L.W.3
  • 3
    • 33744985872 scopus 로고    scopus 로고
    • And the ESCAPE investigators and ESCAPE coordinators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness
    • Stevenson L.W. And the ESCAPE investigators and ESCAPE coordinators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness. JAMA 294 (2005) 1625-1633
    • (2005) JAMA , vol.294 , pp. 1625-1633
    • Stevenson, L.W.1
  • 4
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial
    • Richard C., Warszawski J., Anguel N., et al. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290 (2003) 2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3
  • 5
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland J.M., and Altman D.G. Measuring agreement in method comparison studies. Stat Methods Med Res 8 (1999) 135-160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley L.A.H., and Critchley J.A.J.H. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15 (1999) 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 7
    • 0036273775 scopus 로고    scopus 로고
    • Use of echocardiography for haemodynamic monitoring
    • Brown J.M. Use of echocardiography for haemodynamic monitoring. Crit Care Med 30 (2002) 1361-1364
    • (2002) Crit Care Med , vol.30 , pp. 1361-1364
    • Brown, J.M.1
  • 8
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • Otto C.M., Stoddard M., Waggoner A., et al. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 15 (2002) 167-184
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Otto, C.M.1    Stoddard, M.2    Waggoner, A.3
  • 9
    • 0033385303 scopus 로고    scopus 로고
    • Measurement of cardiac output by transoesophageal echocardiography: a comparison of two Doppler methods with thermodilution
    • Royse C.F., Royce A.G., Blake D.W., et al. Measurement of cardiac output by transoesophageal echocardiography: a comparison of two Doppler methods with thermodilution. Anaesth Intensive Care 27 (1999) 586-590
    • (1999) Anaesth Intensive Care , vol.27 , pp. 586-590
    • Royse, C.F.1    Royce, A.G.2    Blake, D.W.3
  • 11
    • 0037454075 scopus 로고    scopus 로고
    • ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine task Force on clinical competence
    • Quiñones M.A., Douglas P.S., Foster E., et al. ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine task Force on clinical competence. J Am Soc Echocardiogr 4 (2003) 687-708
    • (2003) J Am Soc Echocardiogr , vol.4 , pp. 687-708
    • Quiñones, M.A.1    Douglas, P.S.2    Foster, E.3
  • 12
    • 0027377406 scopus 로고
    • Reliability of a new generation transesophageal Doppler device for cardiac output monitoring
    • Schmid E.R., Spahn D.R., and Tornic M. Reliability of a new generation transesophageal Doppler device for cardiac output monitoring. Anesth Analg 77 (1993) 971-979
    • (1993) Anesth Analg , vol.77 , pp. 971-979
    • Schmid, E.R.1    Spahn, D.R.2    Tornic, M.3
  • 13
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O., Hoke K., Goetz A.E., et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 30 (2002) 52-58
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3
  • 14
    • 0036800276 scopus 로고    scopus 로고
    • Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology
    • Chaney J.C., and Derdak S. Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med 30 (2002) 2338-2345
    • (2002) Crit Care Med , vol.30 , pp. 2338-2345
    • Chaney, J.C.1    Derdak, S.2
  • 15
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • Reuter D.A., Kirchner A., Felbinger T.W., et al. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 31 (2003) 1399-1404
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3
  • 16
    • 85046982917 scopus 로고    scopus 로고
    • Volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
    • Wiesenack C., Prasser C., Rodig G., et al. Volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients. Anesth Analg 96 (2003) 124-157
    • (2003) Anesth Analg , vol.96 , pp. 124-157
    • Wiesenack, C.1    Prasser, C.2    Rodig, G.3
  • 17
    • 0036494427 scopus 로고    scopus 로고
    • Real time, continuous monitoring of cardiac output and oxygen delivery
    • Jonas M., Hert D., and Morgan J. Real time, continuous monitoring of cardiac output and oxygen delivery. Int J Intensive Care 9 (2002) 33-42
    • (2002) Int J Intensive Care , vol.9 , pp. 33-42
    • Jonas, M.1    Hert, D.2    Morgan, J.3
  • 18
    • 0025685462 scopus 로고
    • Pulmonary artery catheter study group: a multicenter study of physicians' knowledge of the pulmonary artery catheter
    • Iberti T.J., Fischer E.P., Leibowitz A.B., et al. Pulmonary artery catheter study group: a multicenter study of physicians' knowledge of the pulmonary artery catheter. JAMA 264 (1990) 2928-2932
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3
  • 19
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz C.W., Miller R.G., Kelly G.E., et al. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 126 (1982) 1001-1004
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3
  • 20
    • 17644432572 scopus 로고
    • Thermodilution method overestimates low cardiac output in humans
    • von Grondelle A., Ditchey R.V., Groves B.M., et al. Thermodilution method overestimates low cardiac output in humans. Am J Physiol 245 (1983) h690-h692
    • (1983) Am J Physiol , vol.245
    • von Grondelle, A.1    Ditchey, R.V.2    Groves, B.M.3
  • 21
    • 22644432668 scopus 로고    scopus 로고
    • Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor
    • Dey I., and Sprivulis P. Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor. Emerg Med 17 (2005) 193-199
    • (2005) Emerg Med , vol.17 , pp. 193-199
    • Dey, I.1    Sprivulis, P.2
  • 22
    • 0037393982 scopus 로고    scopus 로고
    • Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post cardiopulmonary bypass period
    • Zhao X., Mashikian J.S., Panzica P., et al. Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post cardiopulmonary bypass period. J Cardiovasc Anesth 17 (2003) 193-198
    • (2003) J Cardiovasc Anesth , vol.17 , pp. 193-198
    • Zhao, X.1    Mashikian, J.S.2    Panzica, P.3
  • 23
    • 25144520471 scopus 로고    scopus 로고
    • Non invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    • Knobloch K., Lichtenberg A., Winterhalter M., et al. Non invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg 80 (2005) 1479-1484
    • (2005) Ann Thorac Surg , vol.80 , pp. 1479-1484
    • Knobloch, K.1    Lichtenberg, A.2    Winterhalter, M.3
  • 24
    • 33646901597 scopus 로고    scopus 로고
    • Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery
    • Chand R., Mehta Y., and Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 20 (2006) 315-319
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 315-319
    • Chand, R.1    Mehta, Y.2    Trehan, N.3
  • 25
    • 0031765602 scopus 로고    scopus 로고
    • Right ventricular end-diastolic volume index as a predictor of preload status in patients on positive end-expiratory pressure
    • Cheatham M.L., Nelson L.D., Chang M., et al. Right ventricular end-diastolic volume index as a predictor of preload status in patients on positive end-expiratory pressure. Crit Care Med 26 (1998) 1801-1806
    • (1998) Crit Care Med , vol.26 , pp. 1801-1806
    • Cheatham, M.L.1    Nelson, L.D.2    Chang, M.3
  • 26
    • 0027137477 scopus 로고
    • Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • Latson T.W., Whitten C.W., and O'Flaherty D. Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 79 (1993) 1233-1243
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2    O'Flaherty, D.3
  • 27
    • 0024563766 scopus 로고
    • Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation
    • Cigarroa R.G., Lange R.A., Williams R.H., et al. Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86 (1989) 417-420
    • (1989) Am J Med , vol.86 , pp. 417-420
    • Cigarroa, R.G.1    Lange, R.A.2    Williams, R.H.3
  • 28
    • 0027412923 scopus 로고
    • Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility
    • Renner L.E., Morton M.J., and Sakuma G.Y. Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility. Crit Care Med 21 (1993) 586-597
    • (1993) Crit Care Med , vol.21 , pp. 586-597
    • Renner, L.E.1    Morton, M.J.2    Sakuma, G.Y.3
  • 29
    • 59249090780 scopus 로고    scopus 로고
    • Agreement of a non-invasive ultrasound cardiac output monitor (USCOM) device in emergency department patients
    • Losey T., Nguyen H.B., Corbett S.W., et al. Agreement of a non-invasive ultrasound cardiac output monitor (USCOM) device in emergency department patients. Ann Emerg Med 46 (2005) 518
    • (2005) Ann Emerg Med , vol.46 , pp. 518
    • Losey, T.1    Nguyen, H.B.2    Corbett, S.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.