A preliminary investigation on MEMS based immunosensor for E. coli O157:H7 detection

Author keywords

Antibodies; Bacteria; Biosensor; Detection; Escherichia coli; Immunosensor; MEMS; Microcantilever; O157:H7; Piezoresistive; Surface stress

Indexed keywords

DETECTION; MICRO-CANTILEVERS; O157:H7; PIEZO-RESISTIVE; SURFACE STRESS;

EID: 77952146780     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MICC.2009.5431414     Document Type: Conference Paper
Times cited : (4)

References (33)
  • 1
    • 0026096254 scopus 로고
    • Serotype O157:H7 Escherichia coli from bovine and meat sources
    • Dorn, C.R., Angrick, E.J., "Serotype O157:H7 Escherichia coli from bovine and meat sources." J. Clin. Microbiol. 29:1225, 1991.
    • (1991) J. Clin. Microbiol. , vol.29 , pp. 1225
    • Dorn, C.R.1    Angrick, E.J.2
  • 2
    • 0030813002 scopus 로고    scopus 로고
    • Swimming associated hemorrhagic colitis due to Escherichia coli O157:H7 infection: Evidence of prolonged contamination of a fresh water lake
    • Ackman, D., Marks, S., Mack, P., Caldwell, M., Root, T., Birkhead, G., "Swimming associated hemorrhagic colitis due to Escherichia coli O157:H7 infection: evidence of prolonged contamination of a fresh water lake." Epidemiol. Infect. 119:1, 1997.
    • (1997) Epidemiol. Infect. , vol.119 , pp. 1
    • Ackman, D.1    Marks, S.2    Mack, P.3    Caldwell, M.4    Root, T.5    Birkhead, G.6
  • 3
    • 0345269729 scopus 로고    scopus 로고
    • A fatal waterborne disease epidemic in Walkerton, Ontario: Comparison with other waterborne outbreaks in the developed world
    • Hrudrey, S.E., Payment, P., Hych, P.M., Gillham, R.W., Hrudey, E.J., "A fatal waterborne disease epidemic in Walkerton, Ontario: comparison with other waterborne outbreaks in the developed world." Water Sci. Technol. 47, 7, 2003.
    • (2003) Water Sci. Technol. , vol.47 , pp. 7
    • Hrudrey, S.E.1    Payment, P.2    Hych, P.M.3    Gillham, R.W.4    Hrudey, E.J.5
  • 5
    • 0026398187 scopus 로고
    • The epidemiology of infections caused by Escherichia coli of O157:H7, other enterohemorrhagic E. coli and the associated hemolytic uremic syndrome
    • Griffin, P. M., Tauxe, R. V., "The epidemiology of infections caused by Escherichia coli of O157:H7, other enterohemorrhagic E. coli and the associated hemolytic uremic syndrome." Epidemiol. Rev. 13, 60-98, 1991.
    • (1991) Epidemiol. Rev. , vol.13 , pp. 60-98
    • Griffin, P.M.1    Tauxe, R.V.2
  • 6
    • 0028801846 scopus 로고
    • Methods used for detection are recovery of Escherichia coli O157:H7 associated with a foodborne disease outbreak
    • Johnson, J. L., Rose, B. E., Sharar, A. K., Ransom, G. M., Lattuada, C. P., McNamara, A. M., "Methods used for detection are recovery of Escherichia coli O157:H7 associated with a foodborne disease outbreak." J. Food Prot. 58, 597-603, 1995.
    • (1995) J. Food Prot. , vol.58 , pp. 597-603
    • Johnson, J.L.1    Rose, B.E.2    Sharar, A.K.3    Ransom, G.M.4    Lattuada, C.P.5    McNamara, A.M.6
  • 7
    • 84886214976 scopus 로고    scopus 로고
    • Piezoelectric Immunosensors
    • Springer Series
    • Vaughan R.D, Guilbault G.G, "Piezoelectric Immunosensors" Springer Series, Chem Sens Biosens. 5: 237-280, 2007.
    • (2007) Chem Sens Biosens , vol.5 , pp. 237-280
    • Vaughan, R.D.1    Guilbault, G.G.2
  • 8
    • 0031872669 scopus 로고    scopus 로고
    • Detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor
    • DOI 10.1023/A:1008872002336
    • Fratamico P., T. Strobaugh, M. Medina, and A. Gehring, "Detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor," Biotechnol. Tech., vol. 12, pp. 571-576, 1998. (Pubitemid 28358533)
    • (1998) Biotechnology Techniques , vol.12 , Issue.7 , pp. 571-576
    • Fratamico, P.M.1    Strobaugh, T.R.2    Medina, M.B.3    Gehring, A.G.4
  • 9
    • 3142684921 scopus 로고    scopus 로고
    • Detection of E. coli O157:H7 using a surface plasmon resonance biosensor
    • Meeusen C., E. C. Alocilja, and W. Osburn, "Detection of E. coli O157:H7 using a surface plasmon resonance biosensor," in Trans. ASAE 2002.
    • (2002) Trans. ASAE
    • Meeusen, C.1    Alocilja, E.C.2    Osburn, W.3
  • 10
    • 33745871233 scopus 로고    scopus 로고
    • Rapid detection of Salmonella enteritidis and Escherichia coli using surface plasmon resonance biosensor
    • DOI 10.1111/j.1745-4530.2006.00071.x
    • Waswa J.W., C. Debroy and J. Irundayaraj, "Rapid detection of Salmonella enteritidis and Escherichia coli using surface plasmon resonance biosensor", J. Food Process Eng. 29: pp. 373-385, 2006. (Pubitemid 44034306)
    • (2006) Journal of Food Process Engineering , vol.29 , Issue.4 , pp. 373-385
    • Waswa, J.W.1    Debroy, C.2    Irudayaraj, J.3
  • 11
    • 29144528944 scopus 로고    scopus 로고
    • A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7
    • DOI 10.1016/j.bios.2005.03.007, PII S0956566305000904
    • Subramanian A., Irudayaraj J. and Ryan T., "A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E-coli O157: H7." Biosensors & Bioelectronics 21:998-1006, 2006. (Pubitemid 41815107)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.7 , pp. 998-1006
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 12
    • 0033558891 scopus 로고    scopus 로고
    • Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7
    • Abdel-Hamid I., D. Ivnitski, P. Atanasov, and E.Wilkins, "Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7, Biosens. Bioelectron., vol. 14, pp. 309-316, 1998.
    • (1998) Biosens. Bioelectron. , vol.14 , pp. 309-316
    • Abdel-Hamid, I.1    Ivnitski, D.2    Atanasov, P.3    Wilkins, E.4
  • 13
    • 0036010263 scopus 로고    scopus 로고
    • Detection of Escherichia coli O157:h7 in 10- And 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides
    • DeMarco D. and D. Lim, "Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides," J. Food Protection, vol. 65, pp. 596-602, 2002. (Pubitemid 34294203)
    • (2002) Journal of Food Protection , vol.65 , Issue.4 , pp. 596-602
    • Demarco, D.R.1    Lim, D.V.2
  • 14
    • 0029034386 scopus 로고
    • A Rapid, direct method for enumerating respiring enterohemorrhagic E. coli O157:H7 in water
    • Pyle, B.H., Broadway, S.C., McFeters, G.A., "A Rapid, direct method for enumerating respiring enterohemorrhagic E. coli O157:H7 in water." Appl. Environ. Microbiol. 61 (7), 2614-2619, 1995.
    • (1995) Appl. Environ. Microbiol. , vol.61 , Issue.7 , pp. 2614-2619
    • Pyle, B.H.1    Broadway, S.C.2    McFeters, G.A.3
  • 15
    • 77952182631 scopus 로고
    • Federal Register
    • Federal Register, J. Am. Water Works Assoc. 82 (1990) 83
    • (1990) J. Am. Water Works Assoc. , vol.82 , pp. 83
  • 16
    • 1242284104 scopus 로고    scopus 로고
    • Miniature biochip system for detection of Escherichia coli O157:H7 based on antibody-immobilized capillary reactors and enzyme-linked immunosorbent assay
    • in "Miniature biochip system for detection of Escherichia coli O157:H7 based on antibody-immobilized capillary reactors and enzyme-linked immunosorbent assay" J.M. Song, T. Vo-Dinh, Analytica Chimica Acta 507 115-121, 2004.
    • (2004) Analytica Chimica Acta , vol.507 , pp. 115-121
    • Song, J.M.1    Vo-Dinh, T.2
  • 17
    • 1242284104 scopus 로고    scopus 로고
    • Miniature biochip system for detection of Escherichia coli O157:H7 based on antibody-immobilized capillary reactors and enzyme-linked immunosorbent assay
    • Song J. M., T. Vo-Dinh, "Miniature biochip system for detection of Escherichia coli O157:H7 based on antibody-immobilized capillary reactors and enzyme-linked immunosorbent assay", Analytica Chimica Acta 507, pp 115-121, 2004.
    • (2004) Analytica Chimica Acta , vol.507 , pp. 115-121
    • Song, J.M.1    Vo-Dinh, T.2
  • 18
    • 2342519429 scopus 로고    scopus 로고
    • 2 Microcantilever
    • DOI 10.1021/ac035140g
    • Tang, Y., Fang, J., Xu, X., Ji, H.-F., Brown, G.M., and Thundat, T., "Detection of femtomolar concentrations of HF using a SiO2 microcantilever." Anal. Chem. 76, 2478-2481, 2004. (Pubitemid 38585712)
    • (2004) Analytical Chemistry , vol.76 , Issue.9 , pp. 2478-2481
    • Tang, Y.1    Fang, J.2    Xu, X.3    Ji, H.-F.4    Brown, G.M.5    Thundat, T.6
  • 24
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • DOI 10.1016/S0304-3991(99)00148-5, PII S0304399199001485
    • Boisen, A., Thaysen, J., Jensenius H., and Hansen, O., "Environmental sensors based on micromachined cantilevers with integrated read-out", Ultramicroscopy, 82 (1), pp. 11-16, 2000. (Pubitemid 30070078)
    • (2000) Ultramicroscopy , vol.82 , Issue.1-4 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 26
    • 35248835929 scopus 로고    scopus 로고
    • Chemical and biological sensors based on microcantilevers
    • S.Y. Yurish and M.T. S. R. Gomes (eds.), NATO Science Series
    • Daskos P. G., N. V. Lavrik and M. J. Sepaniak, "Chemical and biological sensors based on microcantilevers", in S.Y. Yurish and M.T. S. R. Gomes (eds.), Smart Sensor and MEMS, NATO Science Series, Vol 181,331-379, 2005.
    • (2005) Smart Sensor and MEMS , vol.181 , pp. 331-379
    • Daskos, P.G.1    Lavrik, N.V.2    Sepaniak, M.J.3
  • 28
    • 1942471820 scopus 로고    scopus 로고
    • Diagnosis of Tuberculosis Based on BioMEMS
    • IEEE Journal
    • Kumar S., Ram P Bajpai, Lalit M Bharadwaj, "Diagnosis of Tuberculosis Based On BioMEMS", ICISIP 2004, IEEE Journal.
    • (2004) ICISIP
    • Kumar, S.1    Bajpai, R.P.2    Bharadwaj, L.M.3
  • 29
    • 0033554783 scopus 로고    scopus 로고
    • Sensing of biological substances based on the bending of microfabricated cantilevers
    • DOI 10.1016/S0925-4005(99)00260-9
    • Butt H. J., Raiteri R., Nelles G.,Knoll W., Skladal P., "Sensing of Biological Substances based on the bending of Microfabricated Cantilever." Sens Actuator B-Chem, 61:213-217, 1999. (Pubitemid 30526188)
    • (1999) Sensors and Actuators, B: Chemical , vol.61 , Issue.1 , pp. 213-217
    • Raiteri, R.1    Nelles, G.2    Butt, H.-J.3    Knoll, W.4    Skladal, P.5
  • 30
    • 14844362642 scopus 로고    scopus 로고
    • Cantilever-based biosensors
    • Ziegler, C., Cantilever-based biosensors, Anal Bioanal Chem (2004) 379: 946-959.
    • (2004) Anal Bioanal Chem , vol.379 , pp. 946-959
    • Ziegler, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.