메뉴 건너뛰기




Volumn 20, Issue 4, 2010, Pages 782-789

Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy

Author keywords

Biopsy; Breast; Diagnosis; Needle; Neoplasm; Ultrasound

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BREAST BIOPSY; BREAST CANCER; BREAST TUMOR; CHILD; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; ECHOGRAPHY; FALSE NEGATIVE RESULT; FEMALE; FOLLOW UP; HISTOPATHOLOGY; HUMAN; IMAGE ANALYSIS; MAJOR CLINICAL STUDY; NEEDLE BIOPSY; PRIORITY JOURNAL; RADIODIAGNOSIS; SCHOOL CHILD;

EID: 77952090038     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1632-y     Document Type: Article
Times cited : (47)

References (42)
  • 1
    • 27644481239 scopus 로고    scopus 로고
    • The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases
    • DOI 10.1097/01.sla.0000186186.05971.e0
    • MF Dillon AD Hill CM Quinn A O'Doherty EW McDermott N O'Higgins 2005 The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases Ann Surg 242 701 707 10.1097/01.sla.0000186186.05971.e0 16244544 (Pubitemid 41567126)
    • (2005) Annals of Surgery , vol.242 , Issue.5 , pp. 701-707
    • Dillon, M.F.1    Hill, A.D.K.2    Quinn, C.M.3    O'Doherty, A.4    McDermott, E.W.5    O'Higgins, N.6
  • 2
    • 34548798566 scopus 로고    scopus 로고
    • Interventional breast imaging: Current procedures and assessing for concordance with pathology
    • DOI 10.1016/j.rcl.2007.06.010, PII S0033838907001078, Breast Imaging
    • LW Bassett MC Mahoney SK Apple 2007 Interventional breast imaging: current procedures and assessing for concordance with pathology Radiol Clin North Am 45 881 894 10.1016/j.rcl.2007.06.010 17888775 (Pubitemid 47422268)
    • (2007) Radiologic Clinics of North America , vol.45 , Issue.5 , pp. 881-894
    • Bassett, L.W.1    Mahoney, M.C.2    Apple, S.K.3
  • 3
    • 0034011038 scopus 로고    scopus 로고
    • Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: A meta-analysis
    • 10.1054/bjoc.1999.1036 1:STN:280:DC%2BD3c7pvFKntg%3D%3D 10737383
    • HM Verkooijen PH Peeters E Buskens, et al. 2000 Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis Br J Cancer 82 1017 1021 10.1054/bjoc.1999.1036 1:STN:280:DC%2BD3c7pvFKntg%3D%3D 10737383
    • (2000) Br J Cancer , vol.82 , pp. 1017-1021
    • Verkooijen, H.M.1    Peeters, P.H.2    Buskens, E.3
  • 4
    • 0031000837 scopus 로고    scopus 로고
    • Analysis of cancers not diagnosed at stereotactic core breast biopsy
    • 1:STN:280:DyaK2s3jt1Citw%3D%3D 9122384
    • L Liberman DD Dershaw JR Glassman, et al. 1997 Analysis of cancers not diagnosed at stereotactic core breast biopsy Radiology 203 151 157 1:STN:280:DyaK2s3jt1Citw%3D%3D 9122384
    • (1997) Radiology , vol.203 , pp. 151-157
    • Liberman, L.1    Dershaw, D.D.2    Glassman, J.R.3
  • 5
    • 0033008296 scopus 로고    scopus 로고
    • Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: Frequency of mammographic change and false-negative rate
    • 1:STN:280:DyaK1MzjsVaisQ%3D%3D 10405741
    • CH Lee LE Philpotts LJ Horvath I Tocino 1999 Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: frequency of mammographic change and false-negative rate Radiology 212 189 194 1:STN:280:DyaK1MzjsVaisQ%3D%3D 10405741
    • (1999) Radiology , vol.212 , pp. 189-194
    • Lee, C.H.1    Philpotts, L.E.2    Horvath, L.J.3    Tocino, I.4
  • 6
    • 0028091666 scopus 로고
    • Percutaneous large-core breast biopsy: A multi-institutional study
    • 1:STN:280:DyaK2M%2Fmt12luw%3D%3D 7972743
    • SH Parker F Burbank RJ Jackman, et al. 1994 Percutaneous large-core breast biopsy: a multi-institutional study Radiology 193 359 364 1:STN:280:DyaK2M%2Fmt12luw%3D%3D 7972743
    • (1994) Radiology , vol.193 , pp. 359-364
    • Parker, S.H.1    Burbank, F.2    Jackman, R.J.3
  • 7
    • 0029933897 scopus 로고    scopus 로고
    • Evaluation of nonpalpable solid breast masses with stereotaxic large-needle core biopsy using a dedicated unit
    • 1:STN:280:DyaK283lvVKqsw%3D%3D 8659367
    • JE Meyer RL Christian SC Lester, et al. 1996 Evaluation of nonpalpable solid breast masses with stereotaxic large-needle core biopsy using a dedicated unit AJR Am J Roentgenol 167 179 182 1:STN:280:DyaK283lvVKqsw%3D%3D 8659367
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 179-182
    • Meyer, J.E.1    Christian, R.L.2    Lester, S.C.3
  • 8
    • 1442330147 scopus 로고    scopus 로고
    • Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: Results of the radiologic diagnostic oncology group C study
    • DOI 10.1016/S1076-6332(03)00510-5
    • LL Fajardo ED Pisano DJ Caudry, et al. 2004 Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study Acad Radiol 11 293 308 10.1016/S1076-6332(03) 00510-5 15035520 (Pubitemid 38269468)
    • (2004) Academic Radiology , vol.11 , Issue.3 , pp. 293-308
    • Fajardo, L.L.1    Pisano, E.D.2    Caudry, D.J.3    Gatsonis, C.A.4    Berg, W.A.5    Connolly, J.6    Schnitt, S.7    Page, D.L.8    McNeil, B.J.9
  • 9
    • 37549067008 scopus 로고    scopus 로고
    • Sonographically guided 14-gauge core needle biopsy of breast masses: A review of 2,420 cases with long-term follow-up
    • 10.2214/AJR.07.2419 18094312
    • JH Youk EK Kim MJ Kim KK Oh 2008 Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up AJR Am J Roentgenol 190 202 207 10.2214/AJR.07.2419 18094312
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 202-207
    • Youk, J.H.1    Kim, E.K.2    Kim, M.J.3    Oh, K.K.4
  • 10
    • 13244253714 scopus 로고    scopus 로고
    • Accuracy of sonographically guided 14-gauge core-needle biopsy: Results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions
    • DOI 10.1002/jcu.20089
    • P Crystal M Koretz S Shcharynsky V Makarov S Strano 2005 Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions J Clin Ultrasound 33 47 52 10.1002/jcu.20089 15674836 (Pubitemid 40194410)
    • (2005) Journal of Clinical Ultrasound , vol.33 , Issue.2 , pp. 47-52
    • Crystal, P.1    Koretz, M.2    Shcharynsky, S.3    Makarov, V.4    Strano, S.5
  • 11
    • 49049114113 scopus 로고    scopus 로고
    • US-guided 14-gauge core-needle breast biopsy: Results of a validation study in 1352 cases
    • 10.1148/radiol.2482071994 18641246
    • G Schueller S Jaromi L Ponhold, et al. 2008 US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases Radiology 248 406 413 10.1148/radiol.2482071994 18641246
    • (2008) Radiology , vol.248 , pp. 406-413
    • Schueller, G.1    Jaromi, S.2    Ponhold, L.3
  • 12
    • 0034839255 scopus 로고    scopus 로고
    • Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses
    • 1:STN:280:DC%2BD3MvpvFOjsA%3D%3D 11549157
    • JM Schoonjans RF Brem 2001 Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses J Ultrasound Med 20 967 972 1:STN:280:DC%2BD3MvpvFOjsA%3D%3D 11549157
    • (2001) J Ultrasound Med , vol.20 , pp. 967-972
    • Schoonjans, J.M.1    Brem, R.F.2
  • 13
    • 0031752117 scopus 로고    scopus 로고
    • US-guided core breast biopsy: Use and cost-effectiveness
    • 1:STN:280:DyaK1czptVSktw%3D%3D 9722851
    • L Liberman TL Feng DD Dershaw EA Morris AF Abramson 1998 US-guided core breast biopsy: use and cost-effectiveness Radiology 208 717 723 1:STN:280:DyaK1czptVSktw%3D%3D 9722851
    • (1998) Radiology , vol.208 , pp. 717-723
    • Liberman, L.1    Feng, T.L.2    Dershaw, D.D.3    Morris, E.A.4    Abramson, A.F.5
  • 14
    • 49049095898 scopus 로고    scopus 로고
    • Accuracy of ultrasound-guided, large-core needle breast biopsy
    • 10.1007/s00330-008-0955-4 1:STN:280:DC%2BD1cvpsF2rtA%3D%3D 18414872
    • G Schueller C Schueller-Weidekamm TH Helbich 2008 Accuracy of ultrasound-guided, large-core needle breast biopsy Eur Radiol 18 1761 1773 10.1007/s00330-008-0955-4 1:STN:280:DC%2BD1cvpsF2rtA%3D%3D 18414872
    • (2008) Eur Radiol , vol.18 , pp. 1761-1773
    • Schueller, G.1    Schueller-Weidekamm, C.2    Helbich, T.H.3
  • 15
    • 0037445974 scopus 로고    scopus 로고
    • False-negative core needle biopsies of the breast: An analysis of clinical, radiologic, and pathologic findings in 27 consecutive cases of missed breast cancer
    • DOI 10.1002/cncr.11278
    • VI Shah U Raju D Chitale V Deshpande N Gregory V Strand 2003 False-negative core needle biopsies of the breast: an analysis of clinical, radiologic, and pathologic findings in 27 consecutive cases of missed breast cancer Cancer 97 1824 1831 10.1002/cncr.11278 12673707 (Pubitemid 36397255)
    • (2003) Cancer , vol.97 , Issue.8 , pp. 1824-1831
    • Shah, V.I.1    Raju, U.2    Chitale, D.3    Deshpande, V.4    Gregory, N.5    Strand, V.6
  • 16
    • 0032976596 scopus 로고    scopus 로고
    • Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    • 1:STN:280:DyaK1M3itlyqsw%3D%3D 10207484
    • RJ Jackman KW Nowels J Rodriguez-Soto FA Marzoni Jr SI Finkelstein MJ Shepard 1999 Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up Radiology 210 799 805 1:STN:280:DyaK1M3itlyqsw%3D%3D 10207484
    • (1999) Radiology , vol.210 , pp. 799-805
    • Jackman, R.J.1    Nowels, K.W.2    Rodriguez-Soto, J.3    Marzoni Jr, F.A.4    Finkelstein, S.I.5    Shepard, M.J.6
  • 17
    • 0034671616 scopus 로고    scopus 로고
    • Imaging-histologic discordance at percutaneous breast biopsy: An indicator of missed cancer
    • DOI 10.1002/1097-0142(20001215)89:12<2538::AID-CNCR4>3.0.CO;2-#
    • L Liberman M Drotman EA Morris, et al. 2000 Imaging-histologic discordance at percutaneous breast biopsy Cancer 89 2538 2546 10.1002/1097-0142(20001215)89:12<2538::AID-CNCR4>3.0.CO;2-# 1:STN:280:DC%2BD3M7gvValsQ%3D%3D 11135213 (Pubitemid 32011596)
    • (2000) Cancer , vol.89 , Issue.12 , pp. 2538-2546
    • Liberman, L.1    Drotman, M.2    Morris, E.A.3    Latrenta, L.R.4    Abramson, A.F.5    Zakowski, M.F.6    David Dershaw, D.7
  • 18
    • 4444275728 scopus 로고    scopus 로고
    • Image-guided breast biopsy and management of high-risk lesions
    • DOI 10.1016/j.rcl.2004.04.002, PII S003383890400051X
    • WA Berg 2004 Image-guided breast biopsy and management of high-risk lesions Radiol Clin North Am 42 935 946 10.1016/j.rcl.2004.04.002 15337426 (Pubitemid 39165073)
    • (2004) Radiologic Clinics of North America , vol.42 , Issue.5 , pp. 935-946
    • Berg, W.A.1
  • 19
    • 0031759937 scopus 로고    scopus 로고
    • Methods for analysis of one-step breast biopsy programs
    • 10.1046/j.1524-4741.1998.450307.x
    • F Burbank SH Parker 1998 Methods for analysis of one-step breast biopsy programs Breast J 4 307 319 10.1046/j.1524-4741.1998.450307.x
    • (1998) Breast J , vol.4 , pp. 307-319
    • Burbank, F.1    Parker, S.H.2
  • 20
    • 14844293845 scopus 로고    scopus 로고
    • Ultrasound-guided large-core needle biopsies of breast lesions: Analysis of 962 cases to determine the number of samples for reliable tumour classification
    • 1:STN:280:DC%2BD2M%2Fnt1Skuw%3D%3D 15611793
    • G Sauer H Deissler K Strunz, et al. 2005 Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification Br J Cancer 92 231 235 1:STN:280:DC%2BD2M%2Fnt1Skuw%3D%3D 15611793
    • (2005) Br J Cancer , vol.92 , pp. 231-235
    • Sauer, G.1    Deissler, H.2    Strunz, K.3
  • 21
    • 0027316207 scopus 로고
    • US-guided automated large-core breast biopsy
    • 1:STN:280:DyaK3s3jsVOksw%3D%3D 8475299
    • SH Parker WE Jobe MA Dennis, et al. 1993 US-guided automated large-core breast biopsy Radiology 187 507 511 1:STN:280:DyaK3s3jsVOksw%3D%3D 8475299
    • (1993) Radiology , vol.187 , pp. 507-511
    • Parker, S.H.1    Jobe, W.E.2    Dennis, M.A.3
  • 22
    • 0035171226 scopus 로고    scopus 로고
    • The utility of ultrasonographically guided large-core needle biopsy: Results from 500 consecutive breast biopsies
    • 1:STN:280:DC%2BD3M7jtVKgsQ%3D%3D 11149527
    • DN Smith ML Rosenfield Darling JE Meyer, et al. 2001 The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies J Ultrasound Med 20 43 49 1:STN:280: DC%2BD3M7jtVKgsQ%3D%3D 11149527
    • (2001) J Ultrasound Med , vol.20 , pp. 43-49
    • Smith, D.N.1    Rosenfield Darling, M.L.2    Meyer, J.E.3
  • 23
    • 0036587342 scopus 로고    scopus 로고
    • Ultrasound-guided large-core needle biopsy of the breast: Frequency and results of repeat biopsy
    • 10.1097/00130747-200205000-00003
    • MB Mainiero SL Koelliker E Lazarus B Schepps CH Lee 2002 Ultrasound-guided large-core needle biopsy of the breast: frequency and results of repeat biopsy J Womens Imaging 4 52 57 10.1097/00130747-200205000-00003
    • (2002) J Womens Imaging , vol.4 , pp. 52-57
    • Mainiero, M.B.1    Koelliker, S.L.2    Lazarus, E.3    Schepps, B.4    Lee, C.H.5
  • 24
    • 21244449571 scopus 로고    scopus 로고
    • Sonographically guided core biopsy of the breast: Comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods
    • 10.3348/kjr.2005.6.2.102 15968149
    • N Cho WK Moon JH Cha, et al. 2005 Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods Korean J Radiol 6 102 109 10.3348/kjr.2005.6.2. 102 15968149
    • (2005) Korean J Radiol , vol.6 , pp. 102-109
    • Cho, N.1    Moon, W.K.2    Cha, J.H.3
  • 25
    • 0037306907 scopus 로고    scopus 로고
    • Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast
    • 12540431
    • LE Philpotts RJ Hooley CH Lee 2003 Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast AJR Am J Roentgenol 180 347 351 12540431
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 347-351
    • Philpotts, L.E.1    Hooley, R.J.2    Lee, C.H.3
  • 26
    • 33644794680 scopus 로고    scopus 로고
    • Ultrasound-guided core needle biopsy of non-palpable breast lesions: A prospective analysis in 204 cases
    • 10.1080/02841850500225740 16372687
    • AV Bolivar P Alonso-Bartolome EO Garcia FG Ayensa 2005 Ultrasound-guided core needle biopsy of non-palpable breast lesions: a prospective analysis in 204 cases Acta Radiol 46 690 695 10.1080/02841850500225740 16372687
    • (2005) Acta Radiol , vol.46 , pp. 690-695
    • Bolivar, A.V.1    Alonso-Bartolome, P.2    Garcia, E.O.3    Ayensa, F.G.4
  • 27
    • 51349127347 scopus 로고    scopus 로고
    • Spectrum of papillary lesions of the breast: Clinical, imaging, and pathologic correlation
    • 10.2214/AJR.07.3483 18716096
    • M Muttarak P Lerttumnongtum B Chaiwun WC Peh 2008 Spectrum of papillary lesions of the breast: clinical, imaging, and pathologic correlation AJR Am J Roentgenol 191 700 707 10.2214/AJR.07.3483 18716096
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 700-707
    • Muttarak, M.1    Lerttumnongtum, P.2    Chaiwun, B.3    Peh, W.C.4
  • 28
    • 57549101920 scopus 로고    scopus 로고
    • The management of papillary lesion of the breast by core needle biopsy
    • 1:STN:280:DC%2BD1M%2FgtVymsg%3D%3D 18640002
    • HS Tseng YL Chen ST Chen, et al. 2009 The management of papillary lesion of the breast by core needle biopsy Eur J Surg Oncol 35 21 24 1:STN:280:DC%2BD1M%2FgtVymsg%3D%3D 18640002
    • (2009) Eur J Surg Oncol , vol.35 , pp. 21-24
    • Tseng, H.S.1    Chen, Y.L.2    Chen, S.T.3
  • 29
    • 48149099257 scopus 로고    scopus 로고
    • Benign papilloma on core biopsy requires surgical excision
    • 10.1245/s10434-008-9962-6 18473143
    • AR Skandarajah L Field A Yuen Larn Mou, et al. 2008 Benign papilloma on core biopsy requires surgical excision Ann Surg Oncol 15 2272 2277 10.1245/s10434-008-9962-6 18473143
    • (2008) Ann Surg Oncol , vol.15 , pp. 2272-2277
    • Skandarajah, A.R.1    Field, L.2    Yuen Larn Mou, A.3
  • 30
    • 33745570080 scopus 로고    scopus 로고
    • Role of radiologic features in the management of papillary lesions of the breast
    • DOI 10.2214/AJR.04.1908
    • WW Lam WC Chu AP Tang G Tse TK Ma 2006 Role of radiologic features in the management of papillary lesions of the breast AJR Am J Roentgenol 186 1322 1327 10.2214/AJR.04.1908 1:STN:280:DC%2BD283jsFOmsA%3D%3D 16632726 (Pubitemid 46112568)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.5 , pp. 1322-1327
    • Lam, W.W.M.1    Chu, W.C.W.2    Tang, A.P.Y.3    Tse, G.4    Ma, T.K.F.5
  • 31
    • 33344456858 scopus 로고    scopus 로고
    • Papillary lesions of the breast at percutaneous core-needle biopsy
    • DOI 10.1148/radiol.2382041839
    • CL Mercado D Hamele-Bena SM Oken CI Singer J Cangiarella 2006 Papillary lesions of the breast at percutaneous core-needle biopsy Radiology 238 801 808 10.1148/radiol.2382041839 16424237 (Pubitemid 43289910)
    • (2006) Radiology , vol.238 , Issue.3 , pp. 801-808
    • Mercado, C.L.1    Hamele-Bena, D.2    Oken, S.M.3    Singer, C.I.4    Cangiarella, J.5
  • 32
    • 0036065866 scopus 로고    scopus 로고
    • Percutaneous image-guided core breast biopsy
    • DOI 10.1016/S0033-8389(01)00011-2, PII S0033838901000112
    • L Liberman 2002 Percutaneous image-guided core breast biopsy Radiol Clin North Am 40 483 500 10.1016/S0033-8389(01)00011-2 12117188 (Pubitemid 34765035)
    • (2002) Radiologic Clinics of North America , vol.40 , Issue.3 , pp. 483-500
    • Liberman, L.1
  • 33
    • 34250378639 scopus 로고    scopus 로고
    • Missed breast cancers at US-guided core needle biopsy: How to reduce them
    • 10.1148/rg.271065029 17235000
    • JH Youk EK Kim MJ Kim JY Lee KK Oh 2007 Missed breast cancers at US-guided core needle biopsy: how to reduce them Radiographics 27 79 94 10.1148/rg.271065029 17235000
    • (2007) Radiographics , vol.27 , pp. 79-94
    • Youk, J.H.1    Kim, E.K.2    Kim, M.J.3    Lee, J.Y.4    Oh, K.K.5
  • 36
    • 0347512006 scopus 로고    scopus 로고
    • Sonographic, mammographic, and histopathologic correlation of symptomatic ductal carcinoma in situ
    • 14684521
    • WT Yang GM Tse 2004 Sonographic, mammographic, and histopathologic correlation of symptomatic ductal carcinoma in situ AJR Am J Roentgenol 182 101 110 14684521
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 101-110
    • Yang, W.T.1    Tse, G.M.2
  • 37
    • 41949119999 scopus 로고    scopus 로고
    • Non-calcified ductal carcinoma in situ: Ultrasound and mammographic findings correlated with histological findings
    • DOI 10.3349/ymj.2008.49.1.103
    • KR Cho BK Seo CH Kim, et al. 2008 Non-calcified ductal carcinoma in situ: ultrasound and mammographic findings correlated with histological findings Yonsei Med J 49 103 110 10.3349/ymj.2008.49.1.103 18306476 (Pubitemid 351513652)
    • (2008) Yonsei Medical Journal , vol.49 , Issue.1 , pp. 103-110
    • Cho, K.R.1    Seo, B.K.2    Kim, C.H.3    Whang, K.W.4    Kim, Y.H.5    Kim, B.H.6    Woo, O.H.7    Lee, Y.H.8    Chung, K.B.9
  • 38
    • 33646446309 scopus 로고    scopus 로고
    • Malignant solid breast nodules: Specific types
    • L. McAllister K. Donnellan S.P. Martin R. Rothschild (eds). Lippincott Willams & Wilkins Philadelphia
    • Starvros AT (2004) Malignant solid breast nodules: specific types. In: McAllister L, Donnellan K, Martin SP, Rothschild R (eds) Breast ultrasound. Lippincott Willams & Wilkins, Philadelphia, pp 600-608
    • (2004) Breast Ultrasound , pp. 600-608
    • Starvros, A.T.1
  • 39
    • 4444283756 scopus 로고    scopus 로고
    • Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: Utility and cost study in probably benign lesions
    • 10.1080/02841850410005633 1:STN:280:DC%2BD2cvhvVWktg%3D%3D 15323390
    • P Alonso-Bartolome A Vega-Bolivar M Torres-Tabanera, et al. 2004 Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: utility and cost study in probably benign lesions Acta Radiol 45 390 396 10.1080/02841850410005633 1:STN:280: DC%2BD2cvhvVWktg%3D%3D 15323390
    • (2004) Acta Radiol , vol.45 , pp. 390-396
    • Alonso-Bartolome, P.1    Vega-Bolivar, A.2    Torres-Tabanera, M.3
  • 41
    • 0036803287 scopus 로고    scopus 로고
    • Percutaneous removal of benign breast masses using a vacuum-assisted hand-held device with ultrasound
    • DOI 10.1016/S0002-9610(02)00951-0, PII S0002961002009510
    • RE Fine BA Boyd PW Whitworth JA Kim JK Harness WE Burak 2002 Percutaneous removal of benign breast masses using a vacuum-assisted hand-held device with ultrasound guidance Am J Surg 184 332 336 10.1016/S0002-9610(02)00951-0 12383895 (Pubitemid 35287353)
    • (2002) American Journal of Surgery , vol.184 , Issue.4 , pp. 332-336
    • Fine, R.E.1    Boyd, B.A.2    Whitworth, P.W.3    Kim, J.A.4    Harness, J.K.5    Burak, W.E.6
  • 42
    • 0142182085 scopus 로고    scopus 로고
    • Low-risk palpable breast masses removed using a vacuum-assisted hand-held device
    • DOI 10.1016/S0002-9610(03)00263-0, PII S0002961003002630
    • RE Fine PW Whitworth JA Kim JK Harness BA Boyd WE Burak Jr 2003 Low-risk palpable breast masses removed using a vacuum-assisted hand-held device Am J Surg 186 362 367 10.1016/S0002-9610(03)00263-0 14553851 (Pubitemid 38368611)
    • (2003) American Journal of Surgery , vol.186 , Issue.4 , pp. 362-367
    • Fine, R.E.1    Whitworth, P.W.2    Kim, J.A.3    Harness, J.K.4    Boyd, B.A.5    Burak Jr., W.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.