메뉴 건너뛰기




Volumn 57, Issue 5, 2010, Pages 1008-1011

A robust uniaxial force sensor for minimally invasive surgery

Author keywords

Beating heart surgery; Force feedback; Minimally invasive surgery (MIS); Mitral valve annuloplasty; Optical force sensor

Indexed keywords

ANNULOPLASTY; BEATING HEART SURGERY; FORCE FEEDBACK; MINIMALLY INVASIVE SURGERY; MITRAL VALVES; OPTICAL FORCE;

EID: 77951292005     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2009.2039570     Document Type: Article
Times cited : (93)

References (11)
  • 2
    • 33846122660 scopus 로고    scopus 로고
    • Prototype of instrument for minimally invasive surgery with 6-axis force sensing capability
    • DOI 10.1109/ROBOT.2005.1570167, 1570167, Proceedings of the 2005 IEEE International Conference on Robotics and Automation
    • U. Seibold, B. Kuebler, and G. Hirzinger, "Prototype of instrument for minimally invasive surgery with 6-axis force sensing capability," in Proc. IEEE Int. Conf. Robot. Autom., 2005, pp. 496-501. (Pubitemid 46083846)
    • (2005) Proceedings - IEEE International Conference on Robotics and Automation , vol.2005 , pp. 496-501
    • Seibold, U.1    Kubler, B.2    Hirzinger, G.3
  • 3
    • 0025638374 scopus 로고
    • Development of optical 7-axial force sensor and its signal calibration considering non-linear interference
    • S. Hirose and K. Yoneda, "Development of optical 7-axial force sensor and its signal calibration considering non-linear interference," in Proc. IEEE Int. Conf. Robot. Autom., 1990, pp. 46-53.
    • (1990) Proc. IEEE Int. Conf. Robot. Autom. , pp. 46-53
    • Hirose, S.1    Yoneda, K.2
  • 7
    • 0142196055 scopus 로고    scopus 로고
    • A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation
    • Oct.
    • P. J. Berkelman, L. L.Whitcomb, R. H. Taylor, and P. A. Jensen, "A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation," IEEE Trans. Robot. Autom., vol.19, no.5, pp. 917-921, Oct. 2003.
    • (2003) IEEE Trans. Robot. Autom. , vol.19 , Issue.5 , pp. 917-921
    • Berkelman, P.J.1    Whitcomb, L.L.2    Taylor, R.H.3    Jensen, P.A.4
  • 9
    • 20744460475 scopus 로고    scopus 로고
    • An experimental optical three-axis tactile sensor for micro-robots
    • DOI 10.1017/S0263574704001535
    • M. Ohka, Y. Mitsuya, I. Higashioka, and H. Kabeshita, "An experimental optical three-axis tactile sensor for micro-robots," Robotica, vol.23, pp. 457-465, 2005. (Pubitemid 40850419)
    • (2005) Robotica , vol.23 , Issue.4 , pp. 457-465
    • Ohka, M.1    Mitsuya, Y.2    Higashioka, I.3    Kabeshita, H.4
  • 10