-
1
-
-
84889474528
-
-
st Edn, Ed by T. Reemtsma and M. Jekel. Wiley-VCH, Weinheim, Germany
-
st Edn, Ed by T. Reemtsma and M. Jekel. Wiley-VCH, Weinheim, Germany, pp. 2-13 (2006).
-
(2006)
Organic Pollutants in the Water Cycle
, pp. 2-13
-
-
Reemtsma, T.1
Quintana, J.B.2
-
2
-
-
0022463635
-
Evaluation of silica gel cartridges coated in situ with acidified 2, 4-dinitrophenylhydrazine for sampling aldehydes and ketones in air
-
doi: 10.1080/03067318608077112
-
S.B. Tejada, "Evaluation of silica gel cartridges coated in situ with acidified 2, 4-dinitrophenylhydrazine for sampling aldehydes and ketones in air", Int. J Environ. Anal. Chem. 26, 167 (1986). doi: 10.1080/03067318608077112
-
(1986)
Int. J Environ. Anal. Chem.
, vol.26
, pp. 167
-
-
Tejada, S.B.1
-
3
-
-
0542418748
-
Solid phase microextraction with thermal desorption using fused silica optical fibers
-
doi: 10.1021/ ac00218a019
-
C.L. Arthur and J. Pawliszyn, "Solid phase microextraction with thermal desorption using fused silica optical fibers", Anal. Chem. 62, 2145 (1990). doi: 10.1021/ ac00218a019
-
(1990)
Anal. Chem.
, vol.62
, pp. 2145
-
-
Arthur, C.L.1
Pawliszyn, J.2
-
4
-
-
10944254274
-
Headspace solid-phase microextraction
-
doi: 10.1021/ac00062a008
-
Z. Zhang and J. Pawliszyn, "Headspace solid-phase microextraction", Anal. Chem. 65,1843 (1993). doi: 10.1021/ac00062a008
-
(1843)
Anal. Chem.
, vol.65
, pp. 1993
-
-
Zhang, Z.1
Pawliszyn, J.2
-
5
-
-
0000222794
-
Dynamics of organic compound extraction from water using liquidcoated fused silica fibers
-
doi: 10.1021/ac00034a020
-
D. Louch, S. Motlagh and J. Pawliszyn, "Dynamics of organic compound extraction from water using liquidcoated fused silica fibers", Anal. Chem. 64,1187 (1992). doi: 10.1021/ac00034a020
-
(1992)
Anal. Chem.
, vol.64
, pp. 1187
-
-
Louch, D.1
Motlagh, S.2
Pawliszyn, J.3
-
6
-
-
0026720630
-
Solventless determination of caffeine in beverages using solid-phase microextraction with fused-silica fibers
-
doi: 10.1016/00219673(92)85360-6
-
S.B. Hawthorne. DJ. Miller, J. Pawliszyn and C.L. Arthur, "Solventless determination of caffeine in beverages using solid-phase microextraction with fused-silica fibers", J. Chromatogr. A 603, 185 (1992). doi: 10.1016/00219673(92)85360-6
-
(1992)
J. Chromatogr. A
, vol.603
, pp. 185
-
-
Hawthorne, S.B.1
Miller, D.J.2
Pawliszyn, J.3
Arthur, C.L.4
-
7
-
-
33845518844
-
Passive sampler for dissolved organic matter in freshwater environments
-
doi: 10.1021/ac0608523
-
B. Lam and AJ. Simpson, "Passive sampler for dissolved organic matter in freshwater environments", Anal. Chem. 78, 8194 (2006). doi: 10.1021/ac0608523
-
(2006)
Anal. Chem.
, vol.78
, pp. 8194
-
-
Lam, B.1
Simpson, A.J.2
-
8
-
-
0036067447
-
Passive sampling
-
doi: 10.1016/S01659936(02)00407-7
-
T. Górecki and J. Namiesnik, "Passive sampling", Trends Anal. Chem. 21, 276 (2002). doi: 10.1016/S01659936(02)00407-7
-
(2002)
Trends Anal. Chem.
, vol.21
, pp. 276
-
-
Górecki, T.1
Namiesnik, J.2
-
9
-
-
27944443729
-
Passive sampling techniques for monitoring pollutants in water
-
doi: 10.1016/j.trac.2005.06.006
-
B. Vrana, I.J. Allan, R. Greenwood, G.A. Mills, E. Dominiak, K. Svensson, J. Knutsson and G. Morrison, "Passive sampling techniques for monitoring pollutants in water", Trends Anal. Chem. 24, 845 (2005). doi: 10.1016/j.trac.2005.06.006
-
(2005)
Trends Anal. Chem.
, vol.24
, pp. 845
-
-
Vrana, B.1
Allan, I.J.2
Greenwood, R.3
Mills, G.A.4
Dominiak, E.5
Svensson, K.6
Knutsson, J.7
Morrison, G.8
-
10
-
-
45249119985
-
Environmental mass spectrometry: Emerging contaminants and current issues
-
doi: 10.1021/ac800660d
-
S.D. Richardson, "Environmental mass spectrometry: emerging contaminants and current issues", Anal. Chem. 80, 4373 (2008). doi: 10.1021/ac800660d
-
(2008)
Anal. Chem.
, vol.80
, pp. 4373
-
-
Richardson, S.D.1
-
11
-
-
39749100759
-
Passive sampling in environmental analysis
-
doi: 10.1016/j.chroma.2007.07.070
-
S. Seethapathy, T. Górecki and X. Li, "Passive sampling in environmental analysis", J. Chromatogr. A 1184, 234 (2008). doi: 10.1016/j.chroma.2007.07.070
-
(2008)
J. Chromatogr. A
, vol.1184
, pp. 234
-
-
Seethapathy, S.1
Górecki, T.2
Li, X.3
-
12
-
-
77149120290
-
-
Syracuse Research Corporation Physical Property Database, accessed 10-14-2008
-
Syracuse Research Corporation Physical Property Database, http://www.syrres.com/esc/physdemo.htm(2005), accessed 10-14-2008.
-
(2005)
-
-
-
13
-
-
54749142863
-
Design and characterization of a multisource hand-held tandem mass spectrometer
-
doi: 10.1021/ac801275x
-
L. Gao, A. Sugiarto, J.D. Harper, R.G. Cooks and Z. Ouyang, "Design and characterization of a multisource hand-held tandem mass spectrometer", Anal. Chem. 80, 7198 (2008). doi: 10.1021/ac801275x
-
(2008)
Anal. Chem.
, vol.80
, pp. 7198
-
-
Gao, L.1
Sugiarto, A.2
Harper, J.D.3
Cooks, R.G.4
Ouyang, Z.5
-
14
-
-
33748491707
-
Handheld rectilinear ion trap mass spectrometer
-
doi: 10.1021/ ac061144k
-
L. Gao. Q. Song, G.E. Patterson, R.G. Cooks and Z. Ouyang, "Handheld rectilinear ion trap mass spectrometer", Anal. Chem. 78, 5994 (2006). doi: 10.1021/ ac061144k
-
(2006)
Anal. Chem.
, vol.78
, pp. 5994
-
-
Gao, L.1
Song, Q.2
Patterson, G.E.3
Cooks, R.G.4
Ouyang, Z.5
-
15
-
-
0037115658
-
Miniature cylindrical ion trap mass spectrometer
-
doi: 10.1021/ac020494d
-
G.E. Patterson, A.J. Guymon, L.S. Riter, M. Everly, J. Griep-Raming, B.C. Laughlin, Z. Ouyang and R.G. Cooks, "Miniature cylindrical ion trap mass spectrometer", Anal. Chem. 74, 6145 (2002). doi: 10.1021/ac020494d
-
(2002)
Anal. Chem.
, vol.74
, pp. 6145
-
-
Patterson, G.E.1
Guymon, A.J.2
Riter, L.S.3
Everly, M.4
Griep-Raming, J.5
Laughlin, B.C.6
Ouyang, Z.7
Cooks, R.G.8
-
16
-
-
0001615664
-
Miniature, high-resolution, quadrupole mass-spectrometer array
-
doi: 10.1063/1.1147947
-
O.J. Orient, A. Chutjian and V. Garkanian, "Miniature, high-resolution, quadrupole mass-spectrometer array", Rev. Sci. Inst. 68, 1393 (1997). doi: 10.1063/1.1147947
-
(1997)
Rev. Sci. Inst.
, vol.68
, pp. 1393
-
-
Orient, O.J.1
Chutjian, A.2
Garkanian, V.3
-
17
-
-
0032004479
-
Development of a portable time-of-flight membrane inlet mass spectrometer for environmental analysis
-
doi: 10.1063/1.1148695
-
A.J. White, M.G. Blamire, C.A. Corlett, B.W. Griffiths, D.M. Martin, S.B. Spencer and S.J. Mullock, "Development of a portable time-of-flight membrane inlet mass spectrometer for environmental analysis", Rev. Sci Inst. 69, 565 (1998). doi: 10.1063/1.1148695
-
(1998)
Rev. Sci Inst.
, vol.69
, pp. 565
-
-
White, A.J.1
Blamire, M.G.2
Corlett, C.A.3
Griffiths, B.W.4
Martin, D.M.5
Spencer, S.B.6
Mullock, S.J.7
-
18
-
-
4544361286
-
MICRA: A compact permanent magnet Fourier transform ion cyclotron resonance mass spectrometer
-
doi: 10.1255/ejms.620
-
G. Mauclaire, J. Lemaire, P. Boissel, G. Bellec and M. Heninger, "MICRA: A compact permanent magnet Fourier transform ion cyclotron resonance mass spectrometer", Eur. J. Mass Spectrom. 10, 155 (2004). doi: 10.1255/ejms.620
-
(2004)
Eur. J. Mass Spectrom.
, vol.10
, pp. 155
-
-
Mauclaire, G.1
Lemaire, J.2
Boissel, P.3
Bellec, G.4
Heninger, M.5
-
19
-
-
0035641084
-
Portable doublefocusing mass-spectrometer system for field gas monitoring
-
doi: 10.1002/fact.1016
-
J.A. Diaz, C.F. Giese and W.R. Gentry, "Portable doublefocusing mass-spectrometer system for field gas monitoring", Field Anal. Chem. Technol. 5,156 (2001). doi: 10.1002/fact.1016
-
(2001)
Field Anal. Chem. Technol.
, vol.5
, pp. 156
-
-
Diaz, J.A.1
Giese, C.F.2
Gentry, W.R.3
-
20
-
-
0034040401
-
Miniature mass analyzers
-
doi: 10.1002/1096-9888(200006)35:6<659::AIDJMS5>3.0.CO;2-V
-
E.R. Badman and R.G. Cooks, "Miniature mass analyzers", J. Mass Spectrom. 35, 659 (2000). doi: 10.1002/1096-9888(200006)35:6<659:: AIDJMS5>3.0.CO;2-V
-
(2000)
J. Mass Spectrom.
, vol.35
, pp. 659
-
-
Badman, E.R.1
Cooks, R.G.2
-
21
-
-
0006156938
-
Miniature quadrupole residual gas analyzer for process monitoring
-
doi: 10.1116/1.581251
-
D.H. Holkeboer, T.L. Karandy, F.C. Currier, L.C. Frees and R.E. Ellefson, "Miniature quadrupole residual gas analyzer for process monitoring", J. Vac. Sci. Technol. A 16, 1157, (1998). doi: 10.1116/1.581251
-
(1998)
J. Vac. Sci. Technol. A
, vol.16
, pp. 1157
-
-
Holkeboer, D.H.1
Karandy, T.L.2
Currier, F.C.3
Frees, L.C.4
Ellefson, R.E.5
-
22
-
-
0035564280
-
Sub-miniature ExB sector-field mass spectrometer
-
doi: 10.1016/S10440305(01)00245-8
-
J.A. Diaz, C.F. Giese and W.R. Gentry, "Sub-miniature ExB sector-field mass spectrometer", J. Am. Soc. Mass Spectrom. 12, 619 (2001). doi: 10.1016/S10440305(01)00245-8
-
(2001)
J. Am. Soc. Mass Spectrom.
, vol.12
, pp. 619
-
-
Diaz, J.A.1
Giese, C.F.2
Gentry, W.R.3
-
23
-
-
0000439125
-
High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10-9 to 10-2 Torr
-
doi: 10.1116/1.579938
-
R.J. Ferran and S. Boumsellek, "High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10-9 to 10-2 Torr", J. Vac. Sci. Technol. 14, 1258 (1996). doi: 10.1116/1.579938
-
(1996)
J. Vac. Sci. Technol.
, vol.14
, pp. 1258
-
-
Ferran, R.J.1
Boumsellek, S.2
-
24
-
-
27644526429
-
Monolithic MEMS quadrupole mass spectrometers by deep silicon etching
-
doi: 10.1109/JMEMS.2005.851799
-
M. Geear, R.R.A. Syms, S. Wright and A.S. Holmes, "Monolithic MEMS quadrupole mass spectrometers by deep silicon etching", J. Microelectromech. Syst. 14,1156 (2005). doi: 10.1109/JMEMS.2005.851799
-
(2005)
J. Microelectromech. Syst.
, vol.14
, pp. 1156
-
-
Geear, M.1
Syms, R.R.A.2
Wright, S.3
Holmes, A.S.4
-
25
-
-
13244276451
-
Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer
-
doi: 10.1002/jms.768
-
B.J. Shortt, M.R. Darrach, P.M. Holland and A. Chutjian "Miniaturized system of a gas Chromatograph coupled with a Paul ion trap mass spectrometer", J. Mass Spectrom. 40, 36 (2005). doi: 10.1002/jms.768
-
(2005)
J. Mass Spectrom.
, vol.40
, pp. 36
-
-
Shortt, B.J.1
Darrach, M.R.2
Holland, P.M.3
Chutjian, A.4
-
26
-
-
0032400893
-
A miniature cylindrical ion trap: Simulation and experiment
-
doi: 10.1021/ ac980908w
-
E.R. Badman, R.C Johnson, W.R. Plass and R.G. Cooks, "A miniature cylindrical ion trap: simulation and experiment", Anal. Chem. 70, 4896 (1998). doi: 10.1021/ ac980908w
-
(1998)
Anal. Chem.
, vol.70
, pp. 4896
-
-
Badman, E.R.1
Johnson, R.C.2
Plass, W.R.3
Cooks, R.G.4
-
27
-
-
18144384737
-
Atmospheric pressure ionization in a miniature mass spectrometer
-
doi: 10.1021/ ac0481708
-
B.C. Laughlin, C.C. Mulligan and R.G. Cooks, "Atmospheric pressure ionization in a miniature mass spectrometer", Anal. Chem. 77, 2928 (2005). doi: 10.1021/ ac0481708
-
(2005)
Anal. Chem.
, vol.77
, pp. 2928
-
-
Laughlin, B.C.1
Mulligan, C.C.2
Cooks, R.G.3
-
28
-
-
0037114062
-
Analytical performance of a miniature cylindrical ion trap mass spectrometer
-
doi: 10.1021/ac020494d
-
L.S. Riter. Y. Peng, R.J. Noll, G.E. Patterson, T. Aggerholm and R.G. Cooks, "Analytical performance of a miniature cylindrical ion trap mass spectrometer", Anal. Chem. 74, 6154 (2002). doi: 10.1021/ac020494d
-
(2002)
Anal. Chem.
, vol.74
, pp. 6154
-
-
Riter, L.S.1
Peng, Y.2
Noll, R.J.3
Patterson, G.E.4
Aggerholm, T.5
Cooks, R.G.6
-
29
-
-
0141427982
-
Ion/ molecule reactions performed in a miniature cylindrical ion trap mass spectrometer
-
doi: 10.1039/b303609j
-
L.S. Riter, E.C. Meurer, E.S. Handberg, B.C. Laughlin, H. Chen, G.E. Patterson, M.N. Eberlin and R.G. Cooks, "Ion/ molecule reactions performed in a miniature cylindrical ion trap mass spectrometer", Analyst 128, 1112(2003). doi: 10.1039/b303609j
-
(2003)
Analyst
, vol.128
, pp. 1112
-
-
Riter, L.S.1
Meurer, E.C.2
Handberg, E.S.3
Laughlin, B.C.4
Chen, H.5
Patterson, G.E.6
Eberlin, M.N.7
Cooks, R.G.8
-
30
-
-
1542271546
-
A microfabrication strategy for cylindrical ion trap mass spectrometer arrays
-
doi: 10.1109/ ICSENS.2002.1037178
-
H. Peddanenikalva, K. Potluri, S. Bhansali, R.T. Short and D. Fries, "A microfabrication strategy for cylindrical ion trap mass spectrometer arrays" Sensors, 2002. Proceedings of IEEE 20021, 651 (2002). doi: 10.1109/ ICSENS.2002.1037178
-
(2002)
Sensors, 2002. Proceedings of IEEE 20021
, vol.651
-
-
Peddanenikalva, H.1
Potluri, K.2
Bhansali, S.3
Short, R.T.4
Fries, D.5
-
31
-
-
33644833453
-
Fabrication and testing of a miniature cylindrical ion trap mass spectrometer constructed from low temperature co-fired ceramics
-
doi: 10.1016/j.ijms.2005.12.013
-
A. Chaudhary, F.H.W. van Amerom, RT. Short and S. Bhansali, "Fabrication and testing of a miniature cylindrical ion trap mass spectrometer constructed from low temperature co-fired ceramics", Int. J. Mass Spectrom. 251, 32 (2006). doi: 10.1016/j.ijms.2005.12.013
-
(2006)
Int. J. Mass Spectrom.
, vol.251
, pp. 32
-
-
Chaudhary, A.1
Van Amerom, F.H.W.2
Short, R.T.3
Bhansali, S.4
-
32
-
-
4043060624
-
Rectilinear ion trap: Concepts, calculations, and analytical performance of a new mass analyzer
-
doi: 10.1021/ac049420n
-
Z. Ouyang, G. Wu, Y. Song, H. Li, W.R. Plass and R.G. Cooks, "Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer", Anal. Chem. 76, 4595 [2004). doi: 10.1021/ac049420n
-
(2004)
Anal. Chem.
, vol.76
, pp. 4595
-
-
Ouyang, Z.1
Wu, G.2
Song, Y.3
Li, H.4
Plass, W.R.5
Cooks, R.G.6
-
33
-
-
38849163615
-
Monitoring of toxic compounds in air using a handheld rectilinear ion trap mass spectrometer
-
doi: 10.1021/ ac070906o
-
A. Keil, H. Hernandez-Soto, RJ. Noll, M. Fico, L. Gao, Z. Ouyang and R.G. Cooks, "Monitoring of toxic compounds in air using a handheld rectilinear ion trap mass spectrometer", Anal. Chem. 80, 734 (2008). doi: 10.1021/ ac070906o
-
(2008)
Anal. Chem.
, vol.80
, pp. 734
-
-
Keil, A.1
Hernandez-Soto, H.2
Noll, R.J.3
Fico, M.4
Gao, L.5
Ouyang, Z.6
Cooks, R.G.7
-
34
-
-
35448962977
-
Ambient mass spectrometry with a handheld mass spectrometer at high pressure
-
doi: 10.1021/ac071114x
-
A. Keil, N. Talaty, C Janfelt, R.J. Noll, L. Gao, Z. Ouyang and R.G. Cooks, "Ambient mass spectrometry with a handheld mass spectrometer at high pressure", Anal. Chem. 79, 7734 (2007). doi: 10.1021/ac071114x
-
(2007)
Anal. Chem.
, vol.79
, pp. 7734
-
-
Keil, A.1
Talaty, N.2
Janfelt, C.3
Noll, R.J.4
Gao, L.5
Ouyang, Z.6
Cooks, R.G.7
-
35
-
-
47749095092
-
Rapid hydrocarbon analysis using a miniature rectilinear ion trap mass spectrometer
-
doi: 10.1039/b805813j
-
E. Sokol, K.E. Edwards, K. Qian and R.G. Cooks, "Rapid hydrocarbon analysis using a miniature rectilinear ion trap mass spectrometer", Analyst 133,1064 (2008). doi: 10.1039/b805813j
-
(2008)
Analyst
, vol.133
, pp. 1064
-
-
Sokol, E.1
Edwards, K.E.2
Qian, K.3
Cooks, R.G.4
-
36
-
-
34249294897
-
Glow discharge electron impact ionization source for miniature mass spectrometers
-
doi: 10.1002/jms.1201
-
L. Gao, Q. Song. R.J. Noll, J. Duncan, R.G. Cooks and Z. Ouyang, "Glow discharge electron impact ionization source for miniature mass spectrometers", J. Mass Spectrom. 42, 675 (2007). doi: 10.1002/jms.1201
-
(2007)
J. Mass Spectrom.
, vol.42
, pp. 675
-
-
Gao, L.1
Song, Q.2
Noll, R.J.3
Duncan, J.4
Cooks, R.G.5
Ouyang, Z.6
-
38
-
-
5644249240
-
Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
-
October 15, doi: 10.1126/science.1104404
-
Z. Takats, J.M. Wiseman, B. Gologan and R.G. Cooks, "Mass spectrometry sampling under ambient conditions with desorption electrospray ionization", Science 306, 471 (October 15, 2004). doi: 10.1126/science. 1104404
-
(2004)
Science
, vol.306
, pp. 471
-
-
Takats, Z.1
Wiseman, J.M.2
Gologan, B.3
Cooks, R.G.4
-
39
-
-
44949201809
-
Breaking the pumping speed barrier in mass spectrometry: Discontinuous atmospheric pressure interface
-
doi: 10.1021/ac800014v
-
L. Gao, R.G. Cooks and Z. Ouyang, "Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface", Anal. Chem. 80, 4026 (2008). doi: 10.1021/ac800014v
-
(2008)
Anal. Chem.
, vol.80
, pp. 4026
-
-
Gao, L.1
Cooks, R.G.2
Ouyang, Z.3
-
40
-
-
0028972331
-
The solution-diffusion model: A review
-
doi: 10.1016/0376-7388(95)00102-1
-
J.G. Wijmans and R.W. Baker, "The solution-diffusion model: a review" J. Mem. Sci. 107,1 (1995). doi: 10.1016/0376-7388(95)00102-1
-
(1995)
J. Mem. Sci.
, vol.107
, pp. 1
-
-
Wijmans, J.G.1
Baker, R.W.2
-
41
-
-
0037444733
-
Amino acid clusters formed by sonic spray ionization
-
doi: 10.1021/ ac0260793
-
Z. Takats, S.C Nanita, R.G. Cooks, G. Schlosser and K. Vekey, "Amino acid clusters formed by sonic spray ionization", Anal. Chem. 75,1514 (2003). doi: 10.1021/ ac0260793
-
(2003)
Anal. Chem.
, vol.75
, pp. 1514
-
-
Takats, Z.1
Nanita, S.C.2
Cooks, R.G.3
Schlosser, G.4
Vekey, K.5
-
42
-
-
33645368331
-
Direct monitoring of toxic compounds in air using a portable mass spectrometer
-
doi: 10.1039/b517541k
-
CC Mulligan, D.R. Justes, R.J. Noll, N.L. Sanders, B.C. Laughlin and R.G. Cooks, "Direct monitoring of toxic compounds in air using a portable mass spectrometer", Analyst 131, 556 (2006). doi: 10.1039/b517541k
-
(2006)
Analyst
, vol.131
, pp. 556
-
-
Mulligan, C.C.1
Justes, D.R.2
Noll, R.J.3
Sanders, N.L.4
Laughlin, B.C.5
Cooks, R.G.6
-
43
-
-
33645398573
-
Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry
-
doi: 10.1039/b517541k
-
I. Cotte-Rodriguez, D.R. Justes, S.C. Nanita, R.J. Noll, C.C Mulligan, N.L. Sanders and R.G. Cooks, "Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry", Anaiyst 131, 579 (2006). doi: 10.1039/b517541k
-
(2006)
Anaiyst
, vol.131
, pp. 579
-
-
Cotte-Rodriguez, I.1
Justes, D.R.2
Nanita, S.C.3
Noll, R.J.4
Mulligan, C.C.5
Sanders, N.L.6
Cooks, R.G.7
-
44
-
-
17144443486
-
Electrosonic spray ionization, a gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion-molecule reactions at atmospheric pressure
-
doi: 10.1021/ac049848m
-
Z. Takáts, J.M. Wiseman, B. Gologan and R.G. Cooks, "Electrosonic spray ionization, a gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion-molecule reactions at atmospheric pressure", Anal. Chem. 76, 4050 (2004). doi: 10.1021/ac049848m
-
(2004)
Anal. Chem.
, vol.76
, pp. 4050
-
-
Takáts, Z.1
Wiseman, J.M.2
Gologan, B.3
Cooks, R.G.4
-
45
-
-
33748168091
-
Electrospray ion source: Another variation on the free-jet theme
-
doi: 10.1021/j150664a002
-
M. Yamashitat and J.B. Fenn, "Electrospray ion source: another variation on the free-jet theme", J. Phys. Chem. 88, 4451 (1984). doi: 10.1021/j150664a002
-
(1984)
J. Phys. Chem.
, vol.88
, pp. 4451
-
-
Yamashitat, M.1
Fenn, J.B.2
-
46
-
-
0028179264
-
Ion transport by viscous gas flow through capillaries
-
doi: 10.1016/1044-0305(94)87012-8
-
B. Lin and J. Sunner, "Ion transport by viscous gas flow through capillaries", J. Am. Soc. Mass Spectrom. 5, 873 (1994). doi: 10.1016/1044-0305(94)87012-8
-
(1994)
J. Am. Soc. Mass Spectrom.
, vol.5
, pp. 873
-
-
Lin, B.1
Sunner, J.2
-
47
-
-
12044253267
-
From ions in solution to ions in the gas phase
-
doi: 10.1021/ ac00070a001
-
P. Kebarle and L. Tang, "From ions in solution to ions in the gas phase", Anal. Chem. 65, 972A (1993). doi: 10.1021/ ac00070a001
-
(1993)
Anal. Chem.
, vol.65
-
-
Kebarle, P.1
Tang, L.2
-
48
-
-
0033911130
-
Some tenets pertaining to electrospray ionization mass spectrometry
-
doi: 10.1002/1096-9888(200007)35:7<763::AIDJMS16>3.0.CO;2-#
-
R.B. Cole, "Some tenets pertaining to electrospray ionization mass spectrometry", J. Mass Spectrom. 35, 763 (2000). doi: 10.1002/1096- 9888(200007)35:7<763::AIDJMS16>3.0.CO;2-#
-
(2000)
J. Mass Spectrom.
, vol.35
, pp. 763
-
-
Cole, R.B.1
-
49
-
-
0035497781
-
Practical implications of some recent studies in electrospray ionization fundamentals
-
doi: 10.1002/mas.10008
-
N.B. Cech and C.G. Enke, "Practical implications of some recent studies in electrospray ionization fundamentals", Mass Spectrom. Rev. 20, 362 (2001). doi: 10.1002/mas.10008
-
(2001)
Mass Spectrom. Rev.
, vol.20
, pp. 362
-
-
Cech, N.B.1
Enke, C.G.2
-
50
-
-
0033926938
-
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
-
doi: 10.1002/1096-9888(200007)35:7<804::AIDJMS22>3.0.CO;2-Q
-
P. Kebarle, "A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry", J. Mass Spectrom. 35, 804 (2000). doi: 10.1002/1096-9888(200007)35:7<804::AIDJMS22>3.0.CO;2- Q
-
(2000)
J. Mass Spectrom.
, vol.35
, pp. 804
-
-
Kebarle, P.1
-
51
-
-
84986793944
-
Mass spectrometry of explosives: Nitro compounds, nitrate esters, and nitramines
-
doi: 10.1002/mas.1280010304
-
J. Yinon, "Mass spectrometry of explosives: Nitro compounds, nitrate esters, and nitramines", Mass Spectrom. Rev. 1, 257 (1982). doi: 10.1002/mas.1280010304
-
(1982)
Mass Spectrom. Rev.
, vol.1
, pp. 257
-
-
Yinon, J.1
-
52
-
-
0004096493
-
-
nd Edn, Ed by J. Akhavan. The Royal Society of Chemistry, Cambridge, UK
-
nd Edn, Ed by J. Akhavan. The Royal Society of Chemistry, Cambridge, UK, pp. 21-48(2004).
-
(2004)
The Chemistry of Explosives
, pp. 21-48
-
-
Akhavan, J.1
-
53
-
-
77149175840
-
-
Syracuse Research Corporation Physical Property Database. accessed 10-14-2008.
-
Syracuse Research Corporation Physical Property Database. http://www.syrres.com/esc/physdemo.htm(2005), accessed 10-14-2008.
-
(2005)
-
-
-
54
-
-
77149174030
-
Mass spectra
-
NIST Mass Spec Data Center, S.E. Stein, director, NIST Standard Reference Database Number 69, Ed by PJ. Linstrom and W.G. Mallard. Gaithersburg, MD 20899, accessed 10-27-2009
-
NIST Mass Spec Data Center, S.E. Stein, director, "Mass Spectra" in NISTChemistry WebBook, NIST Standard Reference Database Number 69, Ed by PJ. Linstrom and W.G. Mallard. National Institute of Standards and Technology, Gaithersburg, MD 20899, http://webbook. nist.gov. http://nist.gov, accessed 10-27-2009.
-
NISTChemistry WebBook
-
-
|