메뉴 건너뛰기




Volumn 21, Issue 2, 2010, Pages 135-143

Intraocular lens choices for patients with glaucoma

Author keywords

Cataract surgery; Glaucoma; Intraocular lens

Indexed keywords

MITOMYCIN C; MYDRIATIC AGENT; NONSTEROID ANTIINFLAMMATORY AGENT; POLY(METHYL METHACRYLATE);

EID: 76949108452     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICU.0b013e3283365154     Document Type: Review
Times cited : (30)

References (173)
  • 1
    • 0031454101 scopus 로고    scopus 로고
    • Effect of cataract extraction on the results of automated perimetry in glaucoma
    • Smith SD, Katz J, Quigley HA. Effect of cataract extraction on the results of automated perimetry in glaucoma. Arch Ophthalmol 1997; 115:1515-1519.
    • (1997) Arch Ophthalmol , vol.115 , pp. 1515-1519
    • Smith, S.D.1    Katz, J.2    Quigley, H.A.3
  • 2
    • 0032031621 scopus 로고    scopus 로고
    • The effects of cataract extraction on the visual field of eyes with chronic open-angle glaucoma
    • Chen PP, Budenz DL. The effects of cataract extraction on the visual field of eyes with chronic open-angle glaucoma. Am J Ophthalmol 1998; 125:325-333.
    • (1998) Am J Ophthalmol , vol.125 , pp. 325-333
    • Chen, P.P.1    Budenz, D.L.2
  • 3
    • 0031861458 scopus 로고    scopus 로고
    • Effect of lens opacity on the glaucomatous field of vision
    • Gillies WE, Brooks AM. Effect of lens opacity on the glaucomatous field of vision. Aust NZ J Ophthalmol 1998; 26 (Suppl):19-21.
    • (1998) Aust NZ J Ophthalmol , vol.26 , Issue.SUPPL. , pp. 19-21
    • Gillies, W.E.1    Brooks, A.M.2
  • 4
    • 0034955544 scopus 로고    scopus 로고
    • Influence of cataract surgery on automated perimetry in patients with glaucoma
    • DOI 10.1016/S0002-9394(01)00920-5, PII S0002939401009205
    • Hayashi K, Hayashi H, Nakao F, et al. Influence of cataract surgery on automated perimetry in patients with glaucoma. Am J Ophthalmol 2001; 132:41-46. (Pubitemid 32600888)
    • (2001) American Journal of Ophthalmology , vol.132 , Issue.1 , pp. 41-46
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 5
    • 11144254412 scopus 로고    scopus 로고
    • Visual field changes after cataract extraction: The AGIS experience
    • Koucheki B, Nouri-Mahdavi K, Patel G, et al. Visual field changes after cataract extraction: the AGIS experience. Am J Ophthalmol 2004; 138:1022-1028.
    • (2004) Am J Ophthalmol , vol.138 , pp. 1022-1028
    • Koucheki, B.1    Nouri-Mahdavi, K.2    Patel, G.3
  • 6
    • 33845480063 scopus 로고    scopus 로고
    • Cataract extraction in the collaborative initial glaucoma treatment study: Incidence, risk factors, and the effect of cataract progression and extraction on clinical and quality-of-life outcomes
    • Musch DC, Gillespie BW, Niziolet LM, et al. Cataract extraction in the collaborative initial glaucoma treatment study: incidence, risk factors, and the effect of cataract progression and extraction on clinical and quality-of-life outcomes. Arch Ophthalmol 2006; 124:1694-1700.
    • (2006) Arch Ophthalmol , vol.124 , pp. 1694-1700
    • Musch, D.C.1    Gillespie, B.W.2    Niziolet, L.M.3
  • 7
    • 28444441281 scopus 로고    scopus 로고
    • Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    • Siddiqui MAR, Azuara-Blanco A, Neville S. Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma. Br J Ophthalmol 2005; 89:1569-1571.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1569-1571
    • Siddiqui, M.A.R.1    Azuara-Blanco, A.2    Neville, S.3
  • 8
    • 0028867163 scopus 로고
    • Effect of cataract extraction on automated fields in chronic open-angle glaucoma
    • Stewart WC, Rogers GM, Crinkley CM, et al. Effect of cataract extraction on automated fields in chronic open-angle glaucoma. Arch Ophthalmol 1995; 113:875-879.
    • (1995) Arch Ophthalmol , vol.113 , pp. 875-879
    • Stewart, W.C.1    Rogers, G.M.2    Crinkley, C.M.3
  • 9
    • 34247629081 scopus 로고    scopus 로고
    • Effect of cataract extraction on SITA perimetry in patients with glaucoma
    • Siddiqui MAR, Khairy HA, Azuara-Blanco A. Effect of cataract extraction on SITA perimetry in patients with glaucoma. J Glaucoma 2007; 16:205-208.
    • (2007) J Glaucoma , vol.16 , pp. 205-208
    • Siddiqui, M.A.R.1    Khairy, H.A.2    Azuara-Blanco, A.3
  • 10
    • 0037385106 scopus 로고    scopus 로고
    • Comparison of contrast sensitivity, visual acuity, and Humphrey visual field testing in patients with glaucoma
    • Hawkins AS, Szlyk JP, Ardickas Z, et al. Comparison of contrast sensitivity, visual acuity, and Humphrey visual field testing in patients with glaucoma. J Glaucoma 2003; 12:134-138.
    • (2003) J Glaucoma , vol.12 , pp. 134-138
    • Hawkins, A.S.1    Szlyk, J.P.2    Ardickas, Z.3
  • 11
    • 0024503776 scopus 로고
    • Psychophysical changes in glaucoma
    • Stamper RL. Psychophysical changes in glaucoma. Surv Ophthalmol 1989; 33:309-318.
    • (1989) Surv Ophthalmol , vol.33 , pp. 309-318
    • Stamper, R.L.1
  • 12
    • 0025775401 scopus 로고
    • Design of aspheric intraocular lenses
    • Atchison DA. Design of aspheric intraocular lenses. Ophthalmic Physiol Optics 1991; 11:137-146.
    • (1991) Ophthalmic Physiol Optics , vol.11 , pp. 137-146
    • Atchison, D.A.1
  • 13
    • 0036859728 scopus 로고    scopus 로고
    • Prospective randomized trial of an anterior surface modified prolate intraocular lens
    • Packer M, Fine H, Hoffman RS, Piers PA. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg 2002; 18:692-696.
    • (2002) J Refract Surg , vol.18 , pp. 692-696
    • Packer, M.1    Fine, H.2    Hoffman, R.S.3    Piers, P.A.4
  • 14
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: Clinical comparative study
    • Mester U, Dillinger P, Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg 2003; 29:652-660.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 15
    • 0141643152 scopus 로고    scopus 로고
    • Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; Prospective evaluation
    • Kershner RM. Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; prospective evaluation. J Cataract Refract Surg 2003; 29:1684-1694.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1684-1694
    • Kershner, R.M.1
  • 16
    • 2342497706 scopus 로고    scopus 로고
    • Improved functional vision with a modified prolate intraocular lens
    • DOI 10.1016/j.jcrs.2003.10.022, PII S0886335003010423
    • Packer M, Fine IH, Hoffman RS, Piers PA. Improved functional vision with a modified prolate intraocular lens. J Cataract Refract Surg 2004; 30:986-992. (Pubitemid 38595213)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.5 , pp. 986-992
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3    Piers, P.A.4
  • 17
    • 19344374372 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study
    • Bellucci R, Scialdone A, Buratto L, et al. Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study. J Cataract Refract Surg 2005; 31:712-717.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 712-717
    • Bellucci, R.1    Scialdone, A.2    Buratto, L.3
  • 18
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A, Martone G, Casprini F, Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 2007; 23:639-648.
    • (2007) J Refract Surg , vol.23 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 19
    • 33947595775 scopus 로고    scopus 로고
    • Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: Prospective randomized masked clinical trial
    • Pandita D, Raj SM, Vasavada VA, et al. Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial. J Cataract Refract Surg 2007; 33:603-610.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 603-610
    • Pandita, D.1    Raj, S.M.2    Vasavada, V.A.3
  • 20
    • 35348960381 scopus 로고    scopus 로고
    • Ocular aberrations and contrast sensitivity after cataract surgery with AcrySofIQ intraocular lens implantation; Clinical comparative study
    • Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Ocular aberrations and contrast sensitivity after cataract surgery with AcrySofIQ intraocular lens implantation; clinical comparative study. J Cataract Refract Surg 2007; 33:1918-1924.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1918-1924
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 21
    • 43049138747 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: A comparative study
    • Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 2008; 145:827-833.
    • (2008) Am J Ophthalmol , vol.145 , pp. 827-833
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 22
    • 54149099936 scopus 로고    scopus 로고
    • Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses
    • Mester U, Kaymak H. Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses. J Refract Surg 2008; 24:817-825.
    • (2008) J Refract Surg , vol.24 , pp. 817-825
    • Mester, U.1    Kaymak, H.2
  • 23
    • 65349090618 scopus 로고    scopus 로고
    • Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses
    • Kim SW, Ahn H, Kim EK, Kim TI. Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses. Eye 2008; 22:1493-1498.
    • (2008) Eye , vol.22 , pp. 1493-1498
    • Kim, S.W.1    Ahn, H.2    Kim, E.K.3    Kim, T.I.4
  • 24
    • 65349139486 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses
    • Trueb PR, Albach C, Montes-Mico R, Ferrer-Blasco T. Visual acuity and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses. Ophthalmology 2009; 116:890-895.
    • (2009) Ophthalmology , vol.116 , pp. 890-895
    • Trueb, P.R.1    Albach, C.2    Montes-Mico, R.3    Ferrer-Blasco, T.4
  • 25
    • 69249205437 scopus 로고    scopus 로고
    • Effect of intraocular lens asphericity on quality of vision after cataract removal: An intraindividual comparison
    • Kohnen T, Klaproth OK, Bü hren J. Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison. Ophthalmology 2009; 116:1697-1706.
    • (2009) Ophthalmology , vol.116 , pp. 1697-1706
    • Kohnen, T.1    Klaproth, O.K.2    Bühren, J.3
  • 26
    • 67651071003 scopus 로고    scopus 로고
    • Contrast sensitivity evaluation of aspheric and spherical intraocular lenses 2 years after implantation
    • Caporossi A, Casprini F, Martone G, et al. Contrast sensitivity evaluation of aspheric and spherical intraocular lenses 2 years after implantation. J Refract Surg 2009; 25:578-590.
    • (2009) J Refract Surg , vol.25 , pp. 578-590
    • Caporossi, A.1    Casprini, F.2    Martone, G.3
  • 27
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: A randomized prospective study
    • Rocha KM, Soriano ES, Chalita MR, et al. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 2006; 142:750-756.
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3
  • 28
    • 33846571317 scopus 로고    scopus 로고
    • Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation; Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision
    • Denoyer A, Le Lez ML, Majzoub S, Pisella PJ. Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation; effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision. J Cataract Refract Surg 2007; 33:210-216.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 210-216
    • Denoyer, A.1    Le Lez, M.L.2    Majzoub, S.3    Pisella, P.J.4
  • 29
    • 62649110736 scopus 로고    scopus 로고
    • Wavefront aberrations, depth of focus, and contrast sensitivity with aspheric and spherical intraocular lenses: Fellow-eye study
    • Nanavaty MA, Spalton DJ, Boyce J, et al. Wavefront aberrations, depth of focus, and contrast sensitivity with aspheric and spherical intraocular lenses: fellow-eye study. J Cataract Refract Surg 2009; 35:663-671.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 663-671
    • Nanavaty, M.A.1    Spalton, D.J.2    Boyce, J.3
  • 30
    • 33746068624 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity after cataract surgery wit the Tecnis Z9000 intraocular lens
    • Munoz G, Albarran-Diego C, Montes-Mico R, et al. Spherical aberration and contrast sensitivity after cataract surgery wit the Tecnis Z9000 intraocular lens. J Cataract Refract Surg 2006; 32:1320-1327.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1320-1327
    • Munoz, G.1    Albarran-Diego, C.2    Montes-Mico, R.3
  • 31
    • 33751409274 scopus 로고    scopus 로고
    • Visual performance of aspherical and spherical intraocular lenses: Intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations
    • DOI 10.1016/j.jcrs.2006.07.029, PII S0886335006011394
    • Kasper T, Buhren J, Kohnen T. Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations. J Cataract Refract Surg 2006; 32:2022-2029. (Pubitemid 44816410)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.12 , pp. 2022-2029
    • Kasper, T.1    Buhren, J.2    Kohnen, T.3
  • 32
    • 63449110651 scopus 로고    scopus 로고
    • Intraindividual comparison of functional vision and higher order aberrations after implantation of aspheric and spherical intraocular lenses
    • Su PY, Hu FR. Intraindividual comparison of functional vision and higher order aberrations after implantation of aspheric and spherical intraocular lenses. J Refract Surg 2009; 25:265-272.
    • (2009) J Refract Surg , vol.25 , pp. 265-272
    • Su, P.Y.1    Hu, F.R.2
  • 33
    • 68349150693 scopus 로고    scopus 로고
    • Spherical aberration after implantation of an aspheric versus a spherical intraocular lens in high myopia
    • Yu AY, Wang QM, Sun J, et al. Spherical aberration after implantation of an aspheric versus a spherical intraocular lens in high myopia. Clin Experiment Ophthalmol 2009; 37:558-565.
    • (2009) Clin Experiment Ophthalmol , vol.37 , pp. 558-565
    • Yu, A.Y.1    Wang, Q.M.2    Sun, J.3
  • 34
    • 33847220412 scopus 로고    scopus 로고
    • Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
    • Kurz S, Krummenauer F, Thieme H, Dick HB. Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery. J Cataract Refract Surg 2007; 33:393-400.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 393-400
    • Kurz, S.1    Krummenauer, F.2    Thieme, H.3    Dick, H.B.4
  • 35
    • 41149163942 scopus 로고    scopus 로고
    • Comparison of visual outcomes photopic contrast sensitivity wavefront analysis and patient satisfaction following cataract extraction and IOL implantation: Aspheric vs. spherical acrylic lenses
    • [Advance online publication]
    • Sandoval HP, Fernandez de Castro LE, Vroman DT, Solomon KD. Comparison of visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs. spherical acrylic lenses. Eye 2007 [Advance online publication].
    • (2007) Eye
    • Sandoval, H.P.1    Fernandez De Castro, L.E.2    Vroman, D.T.3    Solomon, K.D.4
  • 36
    • 16344378592 scopus 로고    scopus 로고
    • Optical performance of 3 intraocular lens designs in the presence of decentration
    • Altmann GE, Nichamin LD, Lane SS, Pepose JS. Optical performance of 3 intraocular lens designs in the presence of decentration. J Cataract Refract Surg 2005; 31:574-585.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 574-585
    • Altmann, G.E.1    Nichamin, L.D.2    Lane, S.S.3    Pepose, J.S.4
  • 37
    • 24944471397 scopus 로고    scopus 로고
    • Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye
    • Wang L, Koch DD. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch Ophthalmol 2005; 123:1226-1230.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1226-1230
    • Wang, L.1    Koch, D.D.2
  • 38
    • 33646168600 scopus 로고    scopus 로고
    • Ocular and systemic pseudoexfoliation syndrome [perspective]
    • Schlotzer-Schrehardt U, Naumann GOH. Ocular and systemic pseudoexfoliation syndrome [perspective]. Am J Ophthalmol 2006; 141:921-937.
    • (2006) Am J Ophthalmol , vol.141 , pp. 921-937
    • Schlotzer-Schrehardt, U.1    Naumann, G.O.H.2
  • 39
    • 0035125651 scopus 로고    scopus 로고
    • Exfoliation syndrome
    • DOI 10.1016/S0039-6257(00)00196-X, PII S003962570000196X
    • Ritch R, Schlotzer-Schrehardt U. Exfoliation syndrome. Surv Ophthalmol 2001; 45:265-315. (Pubitemid 32146432)
    • (2001) Survey of Ophthalmology , vol.45 , Issue.4 , pp. 265-315
    • Ritch, R.1    Schlotzer-Schrehardt, U.2
  • 40
    • 0031835486 scopus 로고    scopus 로고
    • Pseudoexfoliation syndrome for the comprehensive ophthalmologist; Intraocular and systemic manifestations
    • Naumann GOH, Schlotzer-Schrehardt U, Kuchle M. Pseudoexfoliation syndrome for the comprehensive ophthalmologist; intraocular and systemic manifestations. Ophthalmology 1998; 105:951-968.
    • (1998) Ophthalmology , vol.105 , pp. 951-968
    • Naumann, G.O.H.1    Schlotzer-Schrehardt, U.2    Kuchle, M.3
  • 41
    • 55649083932 scopus 로고    scopus 로고
    • Exfoliation syndrome: What we know now
    • Ritch R. Exfoliation syndrome: what we know now. Glaucoma Topics Trends 2006; 4:1-4.
    • (2006) Glaucoma Topics Trends , vol.4 , pp. 1-4
    • Ritch, R.1
  • 42
    • 0022538856 scopus 로고
    • Clinical signs of pseudoexfoliation syndrome
    • Prince AM, Ritch R. Clinical signs of pseudoexfoliation syndrome. Ophthalmology 1986; 93:803-807.
    • (1986) Ophthalmology , vol.93 , pp. 803-807
    • Prince, A.M.1    Ritch, R.2
  • 43
    • 0023942756 scopus 로고
    • The chamber angle in ex- foliation syndrome. Clinical and pathologic findings
    • Sampaolesi R, Zarate J, Croxato O. The chamber angle in ex- foliation syndrome. Clinical and pathologic findings. Acta Ophthalmol Suppl 1988; 184:48-53.
    • (1988) Acta Ophthalmol Suppl , vol.184 , pp. 48-53
    • Sampaolesi, R.1    Zarate, J.2    Croxato, O.3
  • 44
    • 0029399936 scopus 로고
    • Pseudoexfoliation material on an acrylic lens [letter]
    • Stewart JF, Jay JL. Pseudoexfoliation material on an acrylic lens [letter]. Br J Ophthalmol 1995; 79:1050-1051.
    • (1995) Br J Ophthalmol , vol.79 , pp. 1050-1051
    • Stewart, J.F.1    Jay, J.L.2
  • 45
    • 0028244532 scopus 로고
    • Exfoliation: The most common identifiable cause of open-angle glaucoma
    • Ritch R. Exfoliation: the most common identifiable cause of open-angle glaucoma. J Glaucoma 1994; 3:176-178.
    • (1994) J Glaucoma , vol.3 , pp. 176-178
    • Ritch, R.1
  • 46
    • 0029050970 scopus 로고
    • Spontaneous dislocation of the lens in pseudoexfoliation syndrome
    • Freissler K, Kuchle M, Naumann GOH. Spontaneous dislocation of the lens in pseudoexfoliation syndrome. Arch Ophthalmol 1995; 113:1095-1096.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1095-1096
    • Freissler, K.1    Kuchle, M.2    Naumann, G.O.H.3
  • 47
    • 0023228737 scopus 로고
    • Risk factors for intraoperative complications in 1000 extracapsular cataract cases
    • Guzek JP, Holm M, Cotter JB, et al. Risk factors for intraoperative complications in 1000 extracapsular cataract cases. Ophthalmology 1987; 94:461-466.
    • (1987) Ophthalmology , vol.94 , pp. 461-466
    • Guzek, J.P.1    Holm, M.2    Cotter, J.B.3
  • 48
    • 0027298741 scopus 로고
    • Exfoliation syndrome and cataract extraction
    • Lumme P, Laatikainen L. Exfoliation syndrome and cataract extraction. Am J Ophthalmol 1993; 116:51-55.
    • (1993) Am J Ophthalmol , vol.116 , pp. 51-55
    • Lumme, P.1    Laatikainen, L.2
  • 49
    • 0037636287 scopus 로고    scopus 로고
    • Outcomes of phacoemulsification in patients with and without pseudoexfoliation syndrome
    • Shingleton BJ, Heltzer J, O'Donoghue MW. Outcomes of phacoemulsification in patients with and without pseudoexfoliation syndrome. J Cataract Refract Surg 2003; 29:1080-1086.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1080-1086
    • Shingleton, B.J.1    Heltzer, J.2    O'Donoghue, M.W.3
  • 50
    • 0024237963 scopus 로고
    • Exfoliation syndrome as a risk factor for vitreous loss in extracapsular cataract surgery (preliminary report); The Erlanger Augenblatter- Group
    • Naumann GOH. Exfoliation syndrome as a risk factor for vitreous loss in extracapsular cataract surgery (preliminary report); the Erlanger Augenblatter- Group. Acta Ophthalmol Suppl 1988; 184:129-131.
    • (1988) Acta Ophthalmol Suppl , vol.184 , pp. 129-131
    • Naumann, G.O.H.1
  • 51
    • 67449097558 scopus 로고    scopus 로고
    • Pseudoexfoliation and the cataract surgeon: Preoperative, intraoperative, and postoperative issues related to intraocular pressure, cataract, and intraocular lenses
    • Shingleton BJ, Crandall AS, Ahmed IK. Pseudoexfoliation and the cataract surgeon: preoperative, intraoperative, and postoperative issues related to intraocular pressure, cataract, and intraocular lenses. J Cataract Refract Surg 2009; 35:1101-1120.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1101-1120
    • Shingleton, B.J.1    Crandall, A.S.2    Ahmed, I.K.3
  • 52
    • 37349015506 scopus 로고    scopus 로고
    • Intraocular pressure elevation within the first 24 h after cataract surgery in patients with glaucoma or exfoliation syndrome
    • Levkovitch-Verbin H, Habot-Wilner Z, Burla N, et al. Intraocular pressure elevation within the first 24 h after cataract surgery in patients with glaucoma or exfoliation syndrome. Ophthalmology 2008; 115:104-108.
    • (2008) Ophthalmology , vol.115 , pp. 104-108
    • Levkovitch-Verbin, H.1    Habot-Wilner, Z.2    Burla, N.3
  • 53
    • 0021751854 scopus 로고
    • Clinical trials of flurbiprofen to maintain pupillary dilation during cataract surgery
    • Keates RH, McGowan KA. Clinical trials of flurbiprofen to maintain pupillary dilation during cataract surgery. Ann Ophthalmol 1984; 16:919-921.
    • (1984) Ann Ophthalmol , vol.16 , pp. 919-921
    • Keates, R.H.1    McGowan, K.A.2
  • 54
    • 0032975488 scopus 로고    scopus 로고
    • Efficacy and safety profile of ketorolac 0.5% ophthalmic solution in the prevention of surgically induced miosis during cataract surgery
    • Stewart R, Grosserode R, Cheetham JK, Rosenthal A. Efficacy and safety profile of ketorolac 0.5% ophthalmic solution in the prevention of surgically induced miosis during cataract surgery. Clin Ther 1999; 21:723-732.
    • (1999) Clin Ther , vol.21 , pp. 723-732
    • Stewart, R.1    Grosserode, R.2    Cheetham, J.K.3    Rosenthal, A.4
  • 55
    • 33750207124 scopus 로고    scopus 로고
    • Capsular tension rings: Update on endocapsular support devices
    • DOI 10.1016/j.ohc.2006.07.001, PII S0896154906000563, Cataract Surgery in the New Millenium
    • Hasanee K, Ahmed IK. Capsular tension rings: update on endocapsular support devices. Ophthalmol Clin North Am 2006; 19:507-519. (Pubitemid 44604505)
    • (2006) Ophthalmology Clinics of North America , vol.19 , Issue.4 , pp. 507-519
    • Hasanee, K.1    Ahmed, I.I.K.2
  • 56
    • 0037325757 scopus 로고    scopus 로고
    • Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis
    • Jacob S, Agarwal A, Agarwal A, et al. Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis. J Cataract Refract Surg 2003; 29:315-321.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 315-321
    • Jacob, S.1    Agarwal, A.2    Agarwal, A.3
  • 57
    • 14644406132 scopus 로고    scopus 로고
    • Interim results of the United States investigational device study of the Ophtec capsular tension ring
    • Price FW Jr, Mackool RJ, Miller KM, et al. Interim results of the United States investigational device study of the Ophtec capsular tension ring. Ophthalmology 2005; 112:460-465.
    • (2005) Ophthalmology , vol.112 , pp. 460-465
    • Price Jr., F.W.1    MacKool, R.J.2    Miller, K.M.3
  • 58
    • 0034750895 scopus 로고    scopus 로고
    • Capsular tension ring implantation after capsulorhexis in phacoemulsification of cataracts associated pseudoexfoliation syndrome; Intraoperative complications and early postoperative findings
    • Bayraktar S, Altan T, Kucuksumer Y, Ylmaz OF. Capsular tension ring implantation after capsulorhexis in phacoemulsification of cataracts associated pseudoexfoliation syndrome; intraoperative complications and early postoperative findings. J Cataract Refract Surg 2001; 27:1620-1628.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1620-1628
    • Bayraktar, S.1    Altan, T.2    Kucuksumer, Y.3    Ylmaz, O.F.4
  • 59
    • 0036233920 scopus 로고    scopus 로고
    • Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery
    • Lee D-H, Shin S-C, Joo C-K. Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery. J Cataract Refract Surg 2002; 28:843-846.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 843-846
    • Lee, D.-H.1    Shin, S.-C.2    Joo, C.-K.3
  • 60
    • 0031659486 scopus 로고    scopus 로고
    • Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation
    • Cionni RJ, Osher RH. Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation. J Cataract Refract Surg 1998; 24:1299-1306.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1299-1306
    • Cionni, R.J.1    Osher, R.H.2
  • 61
    • 0141866731 scopus 로고    scopus 로고
    • Modified capsular tension ring for patients with congenital loss of zonular support
    • Cionni RJ, Osher RH, Marques DMV, et al. Modified capsular tension ring for patients with congenital loss of zonular support. J Cataract Refract Surg 2003; 29:1668-1673.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1668-1673
    • Cionni, R.J.1    Osher, R.H.2    Marques, D.M.V.3
  • 62
  • 63
    • 0036142525 scopus 로고    scopus 로고
    • Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses
    • Abela-Formanek C, Amon M, Schild G, et al. Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg 2002; 28:50-61.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 50-61
    • Abela-Formanek, C.1    Amon, M.2    Schild, G.3
  • 64
    • 0036062050 scopus 로고    scopus 로고
    • Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; Comparison to a control group
    • Abela-Formanek C, Amon M, Schauersberger J, et al. Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome; comparison to a control group. J Cataract Refract Surg 2002; 28:1160-1172.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1160-1172
    • Abela-Formanek, C.1    Amon, M.2    Schauersberger, J.3
  • 65
    • 55649117509 scopus 로고    scopus 로고
    • Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation: Single-surgeon series
    • Shingleton BJ, Laul A, Nagao K, et al. Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation: single-surgeon series. J Cataract Refract Surg 2008; 34:1834-1841.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1834-1841
    • Shingleton, B.J.1    Laul, A.2    Nagao, K.3
  • 66
    • 55649096429 scopus 로고    scopus 로고
    • Foveal thickness after phacoemulsification in patients with pseudoexfoliation syndrome, pseudoexfoliation glaucoma, or primary open-angle glaucoma
    • Yuksel N, Dogu B, Karabasx VL, Caglar Y. Foveal thickness after phacoemulsification in patients with pseudoexfoliation syndrome, pseudoexfoliation glaucoma, or primary open-angle glaucoma. J Cataract Refract Surg 2008; 34:1953-1957.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1953-1957
    • Yuksel, N.1    Dogu, B.2    Karabasx, V.L.3    Caglar, Y.4
  • 67
    • 0032924674 scopus 로고    scopus 로고
    • Latanoprost accelerates disruption of the blood-aqueous barrier and the incidence of angiographic cystoid macular edema in early postoperative pseudoaphakias
    • Miyake K, Ota I, Maekubo K, et al. Latanoprost accelerates disruption of the blood-aqueous barrier and the incidence of angiographic cystoid macular edema in early postoperative pseudoaphakias. Arch Ophthalmol 1999; 117:34-40.
    • (1999) Arch Ophthalmol , vol.117 , pp. 34-40
    • Miyake, K.1    Ota, I.2    Maekubo, K.3
  • 68
    • 0032424289 scopus 로고    scopus 로고
    • Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation
    • Hayashi H, Hayashi K, Nakao F, Hayashi F. Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Arch Ophthalmol 1998; 116:1579-1582.
    • (1998) Arch Ophthalmol , vol.116 , pp. 1579-1582
    • Hayashi, H.1    Hayashi, K.2    Nakao, F.3    Hayashi, F.4
  • 69
    • 0033497365 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses Part II: Choosing the correct haptic fixation and intraocular lens designs to help eradicate posterior capsular opacification
    • Ram J, Apple DJ, Peng Q, et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: choosing the correct haptic fixation and intraocular lens designs to help eradicate posterior capsular opacification. Ophthalmology 1999; 106:891-900.
    • (1999) Ophthalmology , vol.106 , pp. 891-900
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 70
    • 0033951073 scopus 로고    scopus 로고
    • Surgical prevention of posterior capsule opacification. Part 1: Progress in eliminating this complication of cataract surgery
    • Apple DJ, Peng Q, Visessook N, et al. Surgical prevention of posterior capsule opacification. Part 1: progress in eliminating this complication of cataract surgery. J Cataract Refract Surg 2000; 26:180-187.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 180-187
    • Apple, D.J.1    Peng, Q.2    Visessook, N.3
  • 72
    • 13144282668 scopus 로고    scopus 로고
    • A systemic overview of the incidence of posterior capsule opacification
    • Schaumberg DA, Dana MR, Christen WG, Glynn RJ. A systemic overview of the incidence of posterior capsule opacification. Ophthalmology 1998; 105:1213-1221.
    • (1998) Ophthalmology , vol.105 , pp. 1213-1221
    • Schaumberg, D.A.1    Dana, M.R.2    Christen, W.G.3    Glynn, R.J.4
  • 73
    • 27644439862 scopus 로고    scopus 로고
    • Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: A randomized trial
    • DOI 10.1016/j.ophtha.2005.06.021, PII S0161642005008833
    • Findl O, Buehl W, Menapace R, et al. Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial. Ophthalmology 2005; 112:2004-2008. (Pubitemid 41551931)
    • (2005) Ophthalmology , vol.112 , Issue.11 , pp. 2004-2008
    • Findl, O.1    Buehl, W.2    Menapace, R.3    Sacu, S.4    Georgopoulos, M.5    Rainer, G.6
  • 74
    • 4944259292 scopus 로고    scopus 로고
    • Effect of intraocular lenses on preventing posterior capsule opacification: Design versus material
    • Nishi O, Nishi K, Osakabe Y. Effect of intraocular lenses on preventing posterior capsule opacification: design versus material. J Cataract Refract Surg 2004; 30:2170-2176.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2170-2176
    • Nishi, O.1    Nishi, K.2    Osakabe, Y.3
  • 75
    • 24944579209 scopus 로고    scopus 로고
    • Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge
    • Hayashi K, Hayashi H. Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. Ophthalmology 2005; 112:1550-1556.
    • (2005) Ophthalmology , vol.112 , pp. 1550-1556
    • Hayashi, K.1    Hayashi, H.2
  • 76
    • 0032622426 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    • Hollick EJ, Spalton DJ, Ursell PG, et al. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 1999; 106:49-54.
    • (1999) Ophthalmology , vol.106 , pp. 49-54
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 77
    • 0034905521 scopus 로고    scopus 로고
    • Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification
    • Ram J, Pandey S, Apple DJ, et al. Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification. J Cataract Refract Surg 2001; 27:1039-1046.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1039-1046
    • Ram, J.1    Pandey, S.2    Apple, D.J.3
  • 78
    • 0033209776 scopus 로고    scopus 로고
    • The 50th anniversary of the intraocular lens and a quiet revolution. Guest editorial
    • Apple DJ, Peng Q, Ram J. The 50th anniversary of the intraocular lens and a quiet revolution. Guest editorial. Ophthalmology 1999; 106:1861-1862.
    • (1999) Ophthalmology , vol.106 , pp. 1861-1862
    • Apple, D.J.1    Peng, Q.2    Ram, J.3
  • 79
    • 0031309084 scopus 로고    scopus 로고
    • Overview of posterior capsule opacification
    • Sourdille P. Overview of posterior capsule opacification. J Cataract Refract Surg 1997; 23:1431-1432.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1431-1432
    • Sourdille, P.1
  • 80
    • 0021239195 scopus 로고
    • Complications of intraocular lenses. A historical and histopathological review
    • Apple DJ, Mamalis N, Lotfield K, et al. Complications of intraocular lenses. A historical and histopathological review. Surv Ophthalmol 1984; 29:1-54.
    • (1984) Surv Ophthalmol , vol.29 , pp. 1-54
    • Apple, D.J.1    Mamalis, N.2    Lotfield, K.3
  • 81
    • 0032913224 scopus 로고    scopus 로고
    • Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
    • Nishi O, Nishi K. Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. J Cataract Refract Surg 1999; 25:521-526.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 521-526
    • Nishi, O.1    Nishi, K.2
  • 82
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • Nishi O, Nishi K, Mano C, et al. The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers 1998; 29:119-125.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3
  • 83
    • 66249109286 scopus 로고    scopus 로고
    • Nd:YAG laser capsulotomy rates following implantation of square-edged intraocular lenses: Polymethyl methacrylate versus silicone versus acrylic
    • Ram J, Kumar S, Sukhija J, Severia S. Nd:YAG laser capsulotomy rates following implantation of square-edged intraocular lenses: polymethyl methacrylate versus silicone versus acrylic. Can J Ophthalmol 2009; 44:160-164.
    • (2009) Can J Ophthalmol , vol.44 , pp. 160-164
    • Ram, J.1    Kumar, S.2    Sukhija, J.3    Severia, S.4
  • 84
    • 66249112507 scopus 로고    scopus 로고
    • Incidence of Nd:YAG laser capsulotomies after cataract surgery: Comparison of 3 square-edged lenses of different composition
    • Boureau C, Lafuma A, Jeanbat V, et al. Incidence of Nd:YAG laser capsulotomies after cataract surgery: comparison of 3 square-edged lenses of different composition. Can J Ophthalmol 2009; 44:165-170.
    • (2009) Can J Ophthalmol , vol.44 , pp. 165-170
    • Boureau, C.1    Lafuma, A.2    Jeanbat, V.3
  • 85
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • Ursell PG, Spalton DJ, Pande MV, et al. Relationship between intraocular lens biomaterials and posterior capsule opacification. J Cataract Refract Surg 1998; 24:352-360.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 86
    • 0034858143 scopus 로고    scopus 로고
    • Neodymium: YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses
    • Ram J, Kaushik S, Brar GS, Gupta A. Neodymium: YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses. Ophthalmic Surg Lasers 2001; 32:375-382.
    • (2001) Ophthalmic Surg Lasers , vol.32 , pp. 375-382
    • Ram, J.1    Kaushik, S.2    Brar, G.S.3    Gupta, A.4
  • 87
    • 0032942859 scopus 로고    scopus 로고
    • Adhesion mechanisms of human lens epithelial cells on 4 intraocular lens materials
    • Versura P, Torreggiani A, Cellini M, Caramazza R. Adhesion mechanisms of human lens epithelial cells on 4 intraocular lens materials. J Cataract Refract Surg 1999; 25:527-533.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 527-533
    • Versura, P.1    Torreggiani, A.2    Cellini, M.3    Caramazza, R.4
  • 88
    • 0036365244 scopus 로고    scopus 로고
    • Neomydium: YAG capsulotomy rates after phacoemulsification with hydrophobic and hydrophilic acrylic intraocular lenses
    • Javdani Sanatgar Moghaddam Z, Huygens MMAV, Callebaut F. Neomydium: YAG capsulotomy rates after phacoemulsification with hydrophobic and hydrophilic acrylic intraocular lenses. Bull Soc Belge Ophtalmol 2002; 283:13-17.
    • (2002) Bull Soc Belge Ophtalmol , vol.283 , pp. 13-17
    • Javdani Sanatgar Moghaddam, Z.1    Mmav, H.2    Callebaut, F.3
  • 89
    • 9644294334 scopus 로고    scopus 로고
    • Comparison of Nd:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone or acrylic intra-ocular lenses in four European countries
    • European PCO study group
    • Auffarth GU, Brezin A, Caporossi A, et al. European PCO study group. Comparison of Nd:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone or acrylic intra-ocular lenses in four European countries. Ophthalmic Epidemiol 2004; 11:319-329.
    • (2004) Ophthalmic Epidemiol , vol.11 , pp. 319-329
    • Auffarth, G.U.1    Brezin, A.2    Caporossi, A.3
  • 90
    • 0034084997 scopus 로고    scopus 로고
    • Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: Two-year results of a randomized prospective trial
    • Hollick EJ, Spalton DJ, Ursell PG, et al. Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: two-year results of a randomized prospective trial. Am J Ophthalmol 2000; 129:577-584.
    • (2000) Am J Ophthalmol , vol.129 , pp. 577-584
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 91
    • 0043173719 scopus 로고    scopus 로고
    • A comparison of Nd:YAG capsulotomy rate in two different intraocular lenses: Acrysof and Stabibag
    • Stordahl PB, Drolsum L. A comparison of Nd:YAG capsulotomy rate in two different intraocular lenses: Acrysof and Stabibag. Acta Ophthalmol Scand 2003; 81:326-330.
    • (2003) Acta Ophthalmol Scand , vol.81 , pp. 326-330
    • Stordahl, P.B.1    Drolsum, L.2
  • 92
    • 0037254363 scopus 로고    scopus 로고
    • Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materials
    • Linnola RJ, SundM, Ylonen R, Pihlajaniemi T. Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materials. J Cataract Refract Surg 2003; 29:146-152.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 146-152
    • Linnola, R.J.1    Sundm Ylonen, R.2    Pihlajaniemi, T.3
  • 93
    • 0034003905 scopus 로고    scopus 로고
    • Two year results: Sharp versus rounded optic edges on silicone lenses
    • Kruger AJ, Schauersberger J, Abela C, et al. Two year results: sharp versus rounded optic edges on silicone lenses. J Cataract Refract Surg 2000; 26:566-570.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 566-570
    • Kruger, A.J.1    Schauersberger, J.2    Abela, C.3
  • 95
    • 17144414544 scopus 로고    scopus 로고
    • Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: Five-year results of a randomized study
    • Sacu S, Menapace R, Findl O, Georgeopoulos Ml. Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: five-year results of a randomized study. Am J Ophthalmol 2005; 139:696-703.
    • (2005) Am J Ophthalmol , vol.139 , pp. 696-703
    • Sacu, S.1    Menapace, R.2    Findl, O.3    Ml, G.4
  • 96
    • 0035115046 scopus 로고    scopus 로고
    • Eradication of posterior capsule opacification: Documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem
    • Apple DJ, Peng Q, Visessook N, et al. Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 2001; 108:505-518.
    • (2001) Ophthalmology , vol.108 , pp. 505-518
    • Apple, D.J.1    Peng, Q.2    Visessook, N.3
  • 97
    • 34548317041 scopus 로고    scopus 로고
    • Long-term effect of 1-piece and 3-piece hydrophobic acrylic intraocular lens on posterior capsule opacification: A randomized trial
    • Leydolt C, Davidovic S, Sacu S, et al. Long-term effect of 1-piece and 3-piece hydrophobic acrylic intraocular lens on posterior capsule opacification: a randomized trial. Ophthalmology 2007; 114:1663-1669.
    • (2007) Ophthalmology , vol.114 , pp. 1663-1669
    • Leydolt, C.1    Davidovic, S.2    Sacu, S.3
  • 98
    • 34248220388 scopus 로고    scopus 로고
    • Influence of three-piece and singlepiece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: A prospective, randomised, long-term clinical trial
    • Zemaitiene R, Jasinskas V, AuffarthGU. Influence of three-piece and singlepiece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial. Br J Ophthalmol 2007; 91:644-648.
    • (2007) Br J Ophthalmol , vol.91 , pp. 644-648
    • Zemaitiene, R.1    Jasinskas, V.2    Auffarth, G.U.3
  • 99
    • 33748922937 scopus 로고    scopus 로고
    • Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: One-year follow-up
    • Kugelberg M, Wejde G, Jayaram H, Zetterstrom C. Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up. J Cataract Refract Surg 2006; 32: 1627-1631.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1627-1631
    • Kugelberg, M.1    Wejde, G.2    Jayaram, H.3    Zetterstrom, C.4
  • 100
    • 0026338958 scopus 로고
    • Surface properties of intraocular lens materials and their influence on in vitro cell adhesion
    • Cunanan CM, Tarbaux NM, Knight PM. Surface properties of intraocular lens materials and their influence on in vitro cell adhesion. J Cataract Refract Surg 1991; 17:767-773.
    • (1991) J Cataract Refract Surg , vol.17 , pp. 767-773
    • Cunanan, C.M.1    Tarbaux, N.M.2    Knight, P.M.3
  • 101
    • 55649098560 scopus 로고    scopus 로고
    • Effect of intraocular lens design on posterior capsule opacification
    • Buehl W, Findl O. Effect of intraocular lens design on posterior capsule opacification. J Cataract Refract Surg 2008; 34:1976-1985.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1976-1985
    • Buehl, W.1    Findl, O.2
  • 102
    • 42649097233 scopus 로고    scopus 로고
    • Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification
    • Li N, Chen X, Zhang J, et al. Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification. Ophthalmology 2008; 115:830-838.
    • (2008) Ophthalmology , vol.115 , pp. 830-838
    • Li, N.1    Chen, X.2    Zhang, J.3
  • 103
    • 38649094851 scopus 로고    scopus 로고
    • Evaluating and defining the sharpness of intraocular lenses
    • Werner L, Muller M, Tetz M. Evaluating and defining the sharpness of intraocular lenses. J Cataract Refract Surg 2008; 34:310-317.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 310-317
    • Werner, L.1    Muller, M.2    Tetz, M.3
  • 104
    • 8344257990 scopus 로고    scopus 로고
    • The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification
    • Bilge AH, Aykan U, Akin T, Unsal U. The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification. Eur J Ophthalmol 2004; 14:375-380.
    • (2004) Eur J Ophthalmol , vol.14 , pp. 375-380
    • Bilge, A.H.1    Aykan, U.2    Akin, T.3    Unsal, U.4
  • 105
    • 2642514832 scopus 로고    scopus 로고
    • A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses
    • Nejima R, Miyata K, Honbou M, et al. A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. Br J Ophthalmol 2004; 88:746-749.
    • (2004) Br J Ophthalmol , vol.88 , pp. 746-749
    • Nejima, R.1    Miyata, K.2    Honbou, M.3
  • 106
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of singlepiece and three-piece truncated hydrophobic acrylic intraocular lenses
    • Wallin TR, Hinckley M, Nilson C, Olson RJ. A clinical comparison of singlepiece and three-piece truncated hydrophobic acrylic intraocular lenses. Am J Ophthalmol 2003; 136:614-619.
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinckley, M.2    Nilson, C.3    Olson, R.J.4
  • 107
    • 0036068597 scopus 로고    scopus 로고
    • Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge
    • Schmidbauer JM, Escobar-Gomez M, Apple DJ, et al. Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge. J Cataract Refract Surg 2002; 28:1251-1255.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1251-1255
    • Schmidbauer, J.M.1    Escobar-Gomez, M.2    Apple, D.J.3
  • 108
    • 0036145075 scopus 로고    scopus 로고
    • Comparison of long-term incidence of posterior capsular opacification between phacoemulsification and phacotrabeculectomy
    • Shin DH, Vandenbelt SM, Kim PH, et al. Comparison of long-term incidence of posterior capsular opacification between phacoemulsification and phacotrabeculectomy. Am J Ophthalmol 2002; 133:40-47.
    • (2002) Am J Ophthalmol , vol.133 , pp. 40-47
    • Shin, D.H.1    Vandenbelt, S.M.2    Kim, P.H.3
  • 109
    • 0031709164 scopus 로고    scopus 로고
    • Decrease of capsular opacification with adjunctive mitomycin C in combined glaucoma and cataract surgery
    • Shin DH, Kim YY, Ren J, et al. Decrease of capsular opacification with adjunctive mitomycin C in combined glaucoma and cataract surgery. Ophthalmology 1998; 105:1222-1226.
    • (1998) Ophthalmology , vol.105 , pp. 1222-1226
    • Shin, D.H.1    Kim, Y.Y.2    Ren, J.3
  • 110
    • 28244453714 scopus 로고    scopus 로고
    • Comparison of PMMA, foldable silicone and foldable acrylic hydrophobic intraocular lenses in combined phacoemulsification and trabeculectomy
    • Serpa E Jr, Wishart PK. Comparison of PMMA, foldable silicone and foldable acrylic hydrophobic intraocular lenses in combined phacoemulsification and trabeculectomy. Arquivos brasileiros de oftalmologia 2005; 68:29-35.
    • (2005) Arquivos Brasileiros de Oftalmologia , vol.68 , pp. 29-35
    • Serpa Jr., E.1    Wishart, P.K.2
  • 111
    • 0033780758 scopus 로고    scopus 로고
    • Posterior capsular opacification in phacotrabeculectomy: A long-term comparative study of silicone versus acrylic intraocular lens
    • discussion 1874
    • Ober MD, Lemon LC, Shin DH, et al. Posterior capsular opacification in phacotrabeculectomy: a long-term comparative study of silicone versus acrylic intraocular lens. Ophthalmology 2000; 107:1868-1873; discussion 1874.
    • (2000) Ophthalmology , vol.107 , pp. 1868-1873
    • Ober, M.D.1    Lemon, L.C.2    Shin, D.H.3
  • 112
    • 0036069017 scopus 로고    scopus 로고
    • Results of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in uveitic eyes with cataract: Comparison to a control group
    • DOI 10.1016/S0886-3350(02)01425-6, PII S0886335002014256
    • Abela-Formanek C, Amon M, Schauersberger J, et al. Results of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in uveitic eyes with cataract; comparison to a control group. J Cataract Refract Surg 2002; 28:1141-1152. (Pubitemid 34774205)
    • (2002) Journal of Cataract and Refractive Surgery , vol.28 , Issue.7 , pp. 1141-1152
    • Abela-Formanek, C.1    Amon, M.2    Schauersberger, J.3    Kruger, A.4    Nepp, J.5    Schild, G.6
  • 113
    • 0034126195 scopus 로고    scopus 로고
    • Anterior capsule opacification; A histopathological study comparing different IOL styles
    • Werner L, Pandy SK, Escobar-Gomez M, et al. Anterior capsule opacification; a histopathological study comparing different IOL styles. Ophthalmology 2000; 107:463-471.
    • (2000) Ophthalmology , vol.107 , pp. 463-471
    • Werner, L.1    Pandy, S.K.2    Escobar-Gomez, M.3
  • 114
    • 0036142484 scopus 로고    scopus 로고
    • Risk factors for contraction of the anterior capsule opening after cataract surgery
    • Kato S, Suzuki T, Hayashi Y, et al. Risk factors for contraction of the anterior capsule opening after cataract surgery. J Cataract Refract Surg 2002; 28:109-112.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 109-112
    • Kato, S.1    Suzuki, T.2    Hayashi, Y.3
  • 115
    • 49449083282 scopus 로고    scopus 로고
    • Comparison of anterior capsule contraction between 5 foldable intraocular lens models
    • Nagata M, Matsushima H, Mukai K, et al. Comparison of anterior capsule contraction between 5 foldable intraocular lens models. J Cataract Refract Surg 2008; 34:1495-1498.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1495-1498
    • Nagata, M.1    Matsushima, H.2    Mukai, K.3
  • 116
    • 28844470991 scopus 로고    scopus 로고
    • Influence of optic edge design, optic material, and haptic design on capsular bend configuration
    • Sacu S, Findl O, Menapace R, BuehlW. Influence of optic edge design, optic material, and haptic design on capsular bend configuration. J Cataract Refract Surg 2005; 31:1888-1894.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1888-1894
    • Sacu, S.1    Findl, O.2    Menapace, R.3    Buehl, W.4
  • 117
    • 13444311827 scopus 로고    scopus 로고
    • Intraocular lens factors that may affect anterior capsule contraction
    • Hayashi K, Hayashi H. Intraocular lens factors that may affect anterior capsule contraction. Ophthalmology 2005; 112:286-292.
    • (2005) Ophthalmology , vol.112 , pp. 286-292
    • Hayashi, K.1    Hayashi, H.2
  • 118
    • 0032836950 scopus 로고    scopus 로고
    • Capsule contraction after continuous curvilinear capsulorhexis: Poly(methyl methacrylate) versus silicone intraocular lenses
    • Cochener B, Jacq PL, Colin J. Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses. J Cataract Refract Surg 1999; 25:1362-1369.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1362-1369
    • Cochener, B.1    Jacq, P.L.2    Colin, J.3
  • 119
    • 0036732653 scopus 로고    scopus 로고
    • Changes in the area of the anterior capsule opening after intraocular lens implantation
    • Park TK, Chung SK, Baek NH. Changes in the area of the anterior capsule opening after intraocular lens implantation. J Cataract Refract Surg 2002; 28:1613-1617.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1613-1617
    • Park, T.K.1    Chung, S.K.2    Baek, N.H.3
  • 120
    • 0030953868 scopus 로고    scopus 로고
    • Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation
    • Hayashi K, Hayashi H, Nakao F, Hayashi F. Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Am J Ophthalmol 1997; 123:441-447.
    • (1997) Am J Ophthalmol , vol.123 , pp. 441-447
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 121
    • 11144337790 scopus 로고    scopus 로고
    • In vivo digital imaging of the square-edged barrier effect of a silicone intraocular lens
    • Nixon DR. In vivo digital imaging of the square-edged barrier effect of a silicone intraocular lens. J Cataract Refract Surg 2004; 30:2574-2584.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2574-2584
    • Nixon, D.R.1
  • 122
    • 4444244403 scopus 로고    scopus 로고
    • Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction
    • DOI 10.1016/j.jcrs.2004.01.042, PII S0886335004003542
    • Sacu S, Menapace R, Buehl W, et al. Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction. J Cataract Refract Surg 2004; 30:1875-1882. (Pubitemid 39165916)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.9 , pp. 1875-1882
    • Sacu, S.1    Menapace, R.2    Buehl, W.3    Rainer, G.4    Findl, O.5
  • 123
    • 0030924685 scopus 로고    scopus 로고
    • Surgical management of posteriorly dislocated silicone plate haptic intraocular lenses
    • Schneiderman TE, Johnson MW, Smiddy WE, et al. Surgical management of posteriorly dislocated silicone plate haptic intraocular lenses. Am J Ophthalmol 1997; 123:629-635.
    • (1997) Am J Ophthalmol , vol.123 , pp. 629-635
    • Schneiderman, T.E.1    Johnson, M.W.2    Smiddy, W.E.3
  • 124
    • 0031728590 scopus 로고    scopus 로고
    • Comparison of the results of primary and secondary implantation of flexible open-loop anterior chamber intraocular lens
    • Bayramlar H, Hepsen IF, Cekic O, Gunduz A. Comparison of the results of primary and secondary implantation of flexible open-loop anterior chamber intraocular lens. Eye 1998; 12:826-828.
    • (1998) Eye , vol.12 , pp. 826-828
    • Bayramlar, H.1    Hepsen, I.F.2    Cekic, O.3    Gunduz, A.4
  • 125
    • 0030889709 scopus 로고    scopus 로고
    • Randomized controlled trial of anteriorchamber intraocular lenses
    • Hennig A, Evans JR, Pradhan D, et al. Randomized controlled trial of anteriorchamber intraocular lenses. Lancet 1997; 349:1129-1133.
    • (1997) Lancet , vol.349 , pp. 1129-1133
    • Hennig, A.1    Evans, J.R.2    Pradhan, D.3
  • 126
    • 0027212002 scopus 로고
    • Secondary intraocular lens implantation: Anterior chamber vs. posterior chamber lenses
    • Lyle WA, Jin JC. Secondary intraocular lens implantation: anterior chamber vs. posterior chamber lenses. Ophthalmic Surg 1993; 24:375-381.
    • (1993) Ophthalmic Surg , vol.24 , pp. 375-381
    • Lyle, W.A.1    Jin, J.C.2
  • 127
    • 36349020908 scopus 로고    scopus 로고
    • Cataract and glaucoma surgery in pseudoexfoliation syndrome: A review
    • Drolsum L, Ringvold A, Nicolaissen B. Cataract and glaucoma surgery in pseudoexfoliation syndrome: a review. Acta Ophthalmol Scand 2007; 85:810-821.
    • (2007) Acta Ophthalmol Scand , vol.85 , pp. 810-821
    • Drolsum, L.1    Ringvold, A.2    Nicolaissen, B.3
  • 128
    • 0022819250 scopus 로고
    • A retrievable suture idea for anterior uveal problems [Classic Ideas]
    • McCannel MA. A retrievable suture idea for anterior uveal problems [Classic Ideas]. Ophthalmic Surg 1986; 17:739-741.
    • (1986) Ophthalmic Surg , vol.17 , pp. 739-741
    • McCannel, M.A.1
  • 129
    • 0024442687 scopus 로고
    • Dislocated posterior chamber intraocular lens: A new technique of management
    • Smiddy WE. Dislocated posterior chamber intraocular lens: a new technique of management. Arch Ophthalmol 1989; 107:1678-1680.
    • (1989) Arch Ophthalmol , vol.107 , pp. 1678-1680
    • Smiddy, W.E.1
  • 130
    • 0024059010 scopus 로고
    • Posterior chamber lens implantation in the absence of posterior capsular support [letter]
    • reply by WJ Stark, CL Goodman, DF Goodman, JD Gotlsch,606-607
    • Shin DH, Hu BV, Hong YJ, Gibbs KA. Posterior chamber lens implantation in the absence of posterior capsular support [letter]. Ophthalmic Surg 1988; 19:606; reply by WJ Stark, CL Goodman, DF Goodman, JD Gotlsch, 606-607.
    • (1988) Ophthalmic Surg , vol.19 , pp. 606
    • Shin, D.H.1    Hu, B.V.2    Hong, Y.J.3    Gibbs, K.A.4
  • 131
    • 34347241716 scopus 로고    scopus 로고
    • Small-incision iris fixation of foldable intraocular lenses in the absence of capsule support
    • Condon GP, Masket S, Kranemann C, et al. Small-incision iris fixation of foldable intraocular lenses in the absence of capsule support. Ophthalmology 2007; 114:1311-1318.
    • (2007) Ophthalmology , vol.114 , pp. 1311-1318
    • Condon, G.P.1    Masket, S.2    Kranemann, C.3
  • 132
    • 0037399274 scopus 로고    scopus 로고
    • Intraocular lens implantation in the absence of capsular support; A report by the American Academy of Ophthalmology (Ophthalmic Technology Assessment)
    • Wagoner MD, Cox TA, Ariyasu RG, et al. Intraocular lens implantation in the absence of capsular support; a report by the American Academy of Ophthalmology (Ophthalmic Technology Assessment). Ophthalmology 2003; 110:840-859.
    • (2003) Ophthalmology , vol.110 , pp. 840-859
    • Wagoner, M.D.1    Cox, T.A.2    Ariyasu, R.G.3
  • 133
    • 76949109381 scopus 로고    scopus 로고
    • Comparison of outcomes between IOL exchange and IOL suture repositioning for intraocular lens dislocation
    • Presented at the, Atlanta, GA, November 8-11
    • Teichman JC, Calafati J, Vold S, et al. Comparison of outcomes between IOL exchange and IOL suture repositioning for intraocular lens dislocation. Presented at the American Academy of Ophthalmology Annual Meeting, Atlanta, GA, November 8-11, 2008.
    • (2008) American Academy of Ophthalmology Annual Meeting
    • Teichman, J.C.1    Calafati, J.2    Vold, S.3
  • 134
    • 76949104962 scopus 로고    scopus 로고
    • Comparison of scleral-sutured and iris-sutured repositioning for intraocular lens dislocation
    • Presented at the, Atlanta, GA, November 8-11
    • Calafati J, Teichman JC, Vold S, et al. Comparison of scleral-sutured and iris-sutured repositioning for intraocular lens dislocation. Presented at the American Academy of Ophthalmology Annual Meeting, Atlanta, GA, November 8-11, 2008.
    • (2008) American Academy of Ophthalmology Annual Meeting
    • Calafati, J.1    Teichman, J.C.2    Vold, S.3
  • 135
    • 0033780231 scopus 로고    scopus 로고
    • Foldable silicone versus poly(methyl methacrylate) intraocular lenses in combined phacoemulsification and trabeculectomy
    • Braga-Mele R, Cohen S, Rootman DS. Foldable silicone versus poly(methyl methacrylate) intraocular lenses in combined phacoemulsification and trabeculectomy. J Cataract Refract Surg 2000; 26:1517-1522.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1517-1522
    • Braga-Mele, R.1    Cohen, S.2    Rootman, D.S.3
  • 136
    • 0031452728 scopus 로고    scopus 로고
    • Comparative study of silicone versus acrylic foldable lens implantation in primary glaucoma triple procedure
    • Lemon LC, Shin DH, Song MS, et al. Comparative study of silicone versus acrylic foldable lens implantation in primary glaucoma triple procedure. Ophthalmology 1997; 104:1708-1713.
    • (1997) Ophthalmology , vol.104 , pp. 1708-1713
    • Lemon, L.C.1    Shin, D.H.2    Song, M.S.3
  • 137
    • 8144225886 scopus 로고    scopus 로고
    • Foldable acrylic versus rigid polymethylmethacrylate intraocular lens in combined phacoemulsification and trabeculectomy
    • Alzafiri Y, Harasymowycz P. Foldable acrylic versus rigid polymethylmethacrylate intraocular lens in combined phacoemulsification and trabeculectomy. Can J Ophthalmol 2004; 39:609-613.
    • (2004) Can J Ophthalmol , vol.39 , pp. 609-613
    • Alzafiri, Y.1    Harasymowycz, P.2
  • 138
    • 0037243485 scopus 로고    scopus 로고
    • Axial length changes accompanying successful nonpenetrating glaucoma filtration surgery
    • Uretmen O, Ates H, Andac K, et al. Axial length changes accompanying successful nonpenetrating glaucoma filtration surgery. Ophthalmologica 2003; 217:199-203.
    • (2003) Ophthalmologica , vol.217 , pp. 199-203
    • Uretmen, O.1    Ates, H.2    Andac, K.3
  • 139
    • 11144281800 scopus 로고    scopus 로고
    • Changes in axial length following trabeculectomy and glaucoma drainage device surgery
    • Francis BA, Wang M, Lei H, et al. Changes in axial length following trabeculectomy and glaucoma drainage device surgery. Br J Ophthalmol 2005; 89:17-20.
    • (2005) Br J Ophthalmol , vol.89 , pp. 17-20
    • Francis, B.A.1    Wang, M.2    Lei, H.3
  • 140
    • 0035319528 scopus 로고    scopus 로고
    • Short-term effect of mitomycin-C augmented trabeculectomy on axial length and corneal astigmatism
    • Kook MS, Kim HB, Lee SU. Short-term effect of mitomycin-C augmented trabeculectomy on axial length and corneal astigmatism. J Cataract Refract Surg 2001; 27:518-523.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 518-523
    • Kook, M.S.1    Kim, H.B.2    Lee, S.U.3
  • 141
    • 0033498326 scopus 로고    scopus 로고
    • Axial length decrease accompanying successful glaucoma filtration surgery
    • Cashwell LF, Martin CA. Axial length decrease accompanying successful glaucoma filtration surgery. Ophthalmology 1999; 106:2307-2311.
    • (1999) Ophthalmology , vol.106 , pp. 2307-2311
    • Cashwell, L.F.1    Martin, C.A.2
  • 142
    • 0026694885 scopus 로고
    • The effect of trabeculectomy on corneal topography
    • Rosen WJ, Mannis MJ, Brandt JD. The effect of trabeculectomy on corneal topography. Ophthalmic Surg 1992; 23:395-398.
    • (1992) Ophthalmic Surg , vol.23 , pp. 395-398
    • Rosen, W.J.1    Mannis, M.J.2    Brandt, J.D.3
  • 143
    • 0029072184 scopus 로고
    • The effect of trabeculectomy on refraction, keratometry and corneal topography
    • Claridge KG, Galbraith JK, Karmel V, et al. The effect of trabeculectomy on refraction, keratometry and corneal topography. Eye 1995; 9 (Pt 3):292-298.
    • (1995) Eye , vol.9 , Issue.PART 3 , pp. 292-298
    • Claridge, K.G.1    Galbraith, J.K.2    Karmel, V.3
  • 144
    • 0032767595 scopus 로고    scopus 로고
    • Topographic and keratometric astigmatism up to 1 year following small flap trabeculectomy (microtrabeculectomy)
    • Vernon SA, Zambarakji HJ, Potgieter F, et al. Topographic and keratometric astigmatism up to 1 year following small flap trabeculectomy (microtrabeculectomy). Br J Ophthalmol 1999; 83:779-782.
    • (1999) Br J Ophthalmol , vol.83 , pp. 779-782
    • Vernon, S.A.1    Zambarakji, H.J.2    Potgieter, F.3
  • 145
    • 0031746604 scopus 로고    scopus 로고
    • The effect of mitomycin-C on postoperative corneal astigmatism in trabeculectomy and a triple procedure
    • Hong YJ, Choe CM, Lee YG, et al. The effect of mitomycin-C on postoperative corneal astigmatism in trabeculectomy and a triple procedure. Ophthalmic Surg Lasers 1998; 29:484-489.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 484-489
    • Hong, Y.J.1    Choe, C.M.2    Lee, Y.G.3
  • 146
    • 0026081937 scopus 로고
    • Changes in keratometry following trabeculectomy
    • Hugkulstone CE. Changes in keratometry following trabeculectomy. Br J Ophthalmol 1991; 75:217-218.
    • (1991) Br J Ophthalmol , vol.75 , pp. 217-218
    • Hugkulstone, C.E.1
  • 147
    • 67651158943 scopus 로고    scopus 로고
    • Predicted refraction versus refraction outcome in cataract surgery after trabeculectomy
    • Muallem MS, Nelson GA, Osmanovic S, et al. Predicted refraction versus refraction outcome in cataract surgery after trabeculectomy. J Glaucoma 2009; 18:284-287.
    • (2009) J Glaucoma , vol.18 , pp. 284-287
    • Muallem, M.S.1    Nelson, G.A.2    Osmanovic, S.3
  • 148
    • 11144319460 scopus 로고    scopus 로고
    • Refractive error with optimum intraocular lens power calculation after glaucoma filtering surgery
    • Tan HY, Wu SC. Refractive error with optimum intraocular lens power calculation after glaucoma filtering surgery. J Cataract Refract Surg 2004; 30:2595-2597.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2595-2597
    • Tan, H.Y.1    Wu, S.C.2
  • 149
    • 39149125443 scopus 로고    scopus 로고
    • Blue light-filter intraocular lenses in vitrectomy combined with cataract surgery: Results of a randomized controlled clinical trial
    • Falkner-Radler CI, Benesch T, Binder S. Blue light-filter intraocular lenses in vitrectomy combined with cataract surgery: results of a randomized controlled clinical trial. Am J Ophthalmol 2008; 145:499-503.
    • (2008) Am J Ophthalmol , vol.145 , pp. 499-503
    • Falkner-Radler, C.I.1    Benesch, T.2    Binder, S.3
  • 150
    • 57949093825 scopus 로고    scopus 로고
    • Influence of blue-lightfiltering intraocular lenses on color perception and contrast acuity
    • Wirtitsch MG, Schmidinger G, Prskavec M, et al. Influence of blue-lightfiltering intraocular lenses on color perception and contrast acuity. Ophthalmology 2009; 116:39-45.
    • (2009) Ophthalmology , vol.116 , pp. 39-45
    • Wirtitsch, M.G.1    Schmidinger, G.2    Prskavec, M.3
  • 151
    • 41249093676 scopus 로고    scopus 로고
    • Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens
    • Mester U, Holz F, Kohnen T, et al. Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens. J Cataract Refract Surg 2008; 34:608-615.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 608-615
    • Mester, U.1    Holz, F.2    Kohnen, T.3
  • 152
    • 33947596198 scopus 로고    scopus 로고
    • Effect of a yellow intraocular lens on scotopic vision, glare disability, and blue color perception
    • Muftuoglu O, Karel F, Duman R. Effect of a yellow intraocular lens on scotopic vision, glare disability, and blue color perception. J Cataract Refract Surg 2007; 33:658-666.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 658-666
    • Muftuoglu, O.1    Karel, F.2    Duman, R.3
  • 153
    • 33746552757 scopus 로고    scopus 로고
    • Visual function in patients with yellow tinted intraocular lenses compared with vision in patients with nontinted intraocular lenses
    • Hayashi K, Hayashi H. Visual function in patients with yellow tinted intraocular lenses compared with vision in patients with nontinted intraocular lenses. Br J Ophthalmol 2006; 90:1019-1023.
    • (2006) Br J Ophthalmol , vol.90 , pp. 1019-1023
    • Hayashi, K.1    Hayashi, H.2
  • 155
    • 27144446144 scopus 로고    scopus 로고
    • Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation
    • Rodriguez-Galietero A, Montes-Mico R, Munoz G, Albarran-Diego C. Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation. J Cataract Refract Surg 2005; 31:1736-1740.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1736-1740
    • Rodriguez-Galietero, A.1    Montes-Mico, R.2    Munoz, G.3    Albarran-Diego, C.4
  • 156
    • 32244442037 scopus 로고    scopus 로고
    • Clinical results of the blue-light filtering AcrySof Natural foldable acrylic intraocular lens
    • Marshall J, Cionni RJ, Davison J, et al. Clinical results of the blue-light filtering AcrySof Natural foldable acrylic intraocular lens. J Cataract Refract Surg 2005; 31:2319-2323.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2319-2323
    • Marshall, J.1    Cionni, R.J.2    Davison, J.3
  • 157
    • 65249104062 scopus 로고    scopus 로고
    • Intraindividual comparison of color perception and contrast sensitivity with and without a blue light-filtering intraocular lens
    • Eberhard R, Roberti P, Prü nte C. Intraindividual comparison of color perception and contrast sensitivity with and without a blue light-filtering intraocular lens. Eur J Ophthalmol 2009; 19:235-239.
    • (2009) Eur J Ophthalmol , vol.19 , pp. 235-239
    • Eberhard, R.1    Roberti, P.2    Prünte, C.3
  • 158
    • 30444435349 scopus 로고    scopus 로고
    • Bluelight- filter intraocular lens in patients with diabetes: Contrast sensitivity and chromatic discrimination
    • Rodriguez-Galietero A, Montes-Mico R, Munoz G, Albarran-Diego C. Bluelight- filter intraocular lens in patients with diabetes: contrast sensitivity and chromatic discrimination. J Cataract Refract Surg 2005; 31:2088-2092.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2088-2092
    • Rodriguez-Galietero, A.1    Montes-Mico, R.2    Munoz, G.3    Albarran-Diego, C.4
  • 159
    • 3042789531 scopus 로고    scopus 로고
    • Contrast sensitivity and color vision with a yellow intraocular lens
    • Yuan Z, Reinach P, Yuan J. Contrast sensitivity and color vision with a yellow intraocular lens. Am J Ophthalmol 2004; 138:138-140.
    • (2004) Am J Ophthalmol , vol.138 , pp. 138-140
    • Yuan, Z.1    Reinach, P.2    Yuan, J.3
  • 162
    • 0141501407 scopus 로고    scopus 로고
    • Multifocal versus monofocal intraocular lenses after cataract extract
    • Leyland M, Pringle E. Multifocal versus monofocal intraocular lenses after cataract extract. Cochrane Database Syst Rev 2003;(1):CD003169.
    • (2003) Cochrane Database Syst Rev , Issue.1
    • Leyland, M.1    Pringle, E.2
  • 163
    • 33646182938 scopus 로고    scopus 로고
    • Visual performance of AcrySof apodized diffractive IOL: A prospective comparative trial
    • Souza CE, Mucciolli C, Soriano ES, et al. Visual performance of AcrySof apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol 2006; 141:827-832.
    • (2006) Am J Ophthalmol , vol.141 , pp. 827-832
    • Souza, C.E.1    Mucciolli, C.2    Soriano, E.S.3
  • 164
    • 33845647705 scopus 로고    scopus 로고
    • Bilateral implantation of Tecnis ZM900 or ReSTOR diffractive IOLs versus ReZoom multifocal IOL
    • Presented at the June; Washington DC, USA
    • Ravalico G. Bilateral implantation of Tecnis ZM900 or ReSTOR diffractive IOLs versus ReZoom multifocal IOL. Presented at the Annual symposium of the American Society of Cataract and Refractive surgery; June 2006; Washington DC, USA.
    • (2006) Annual Symposium of the American Society of Cataract and Refractive Surgery
    • Ravalico, G.1
  • 165
    • 0033498225 scopus 로고    scopus 로고
    • A prospective comparative study of the AMO ARRAY zonal-progressive multifocal intraocular lens implantation: Functional status and quality of life
    • Steinert RF, Aker BL, Trentacost DJ, et al. A prospective comparative study of the AMO ARRAY zonal-progressive multifocal intraocular lens implantation: functional status and quality of life. Ophthalmology 1999; 106:1243-1255.
    • (1999) Ophthalmology , vol.106 , pp. 1243-1255
    • Steinert, R.F.1    Aker, B.L.2    Trentacost, D.J.3
  • 166
    • 0026766172 scopus 로고
    • A prospective, randomized, doublemasked comparison of a zonal-progressive multifocal intraocular lens
    • discussion by JT Holladay, 860-861
    • Steinert RF, Post CT Jr, Brint SF, et al. A prospective, randomized, doublemasked comparison of a zonal-progressive multifocal intraocular lens. Ophthalmology 1992; 99:853-860; discussion by JT Holladay, 860-861.
    • (1992) Ophthalmology , vol.99 , pp. 853-860
    • Steinert, R.F.1    Post Jr., C.T.2    Brint, S.F.3
  • 167
  • 168
    • 34250675214 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity: AcrySof ReSTOR versus AcrySof SA60AT monofocal intraocular lenses
    • Vingolo EM, Grenga PL, Iacobelli L, Grenga R. Visual acuity and contrast sensitivity: AcrySof ReSTOR versus AcrySof SA60AT monofocal intraocular lenses. J Cataract Refract Surg 2007; 33:1244-1247.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1244-1247
    • Vingolo, E.M.1    Grenga, P.L.2    Iacobelli, L.3    Grenga, R.4
  • 169
    • 76949098324 scopus 로고    scopus 로고
    • Point-counterpoint: Cataract surgery in the glaucoma patient: Don't use a multifocal?
    • Presented at the, Glaucoma Subspecialty Day, Atlanta GA, November 8
    • Ahmed IK, Teichman JC. Point-counterpoint: cataract surgery in the glaucoma patient: don't use a multifocal? Presented at the American Academy of Ophthalmology, Glaucoma Subspecialty Day, Atlanta GA, November 8, 2008.
    • (2008) American Academy of Ophthalmology
    • Ahmed, I.K.1    Teichman, J.C.2
  • 170
    • 76949108365 scopus 로고    scopus 로고
    • Multifocal IOLs and glaucoma: How much is too much?
    • Chang D, editor. . Thorofare, NJ: Slack Incorporated
    • Ahmed IK, Teichman JC. Multifocal IOLs and glaucoma: how much is too much? In: Chang D, editor. Transitioning to refractive IOLs: the art and science. Thorofare, NJ: Slack Incorporated; 2008. pp. 384-385.
    • (2008) Transitioning to Refractive IOLs: The Art and Science , pp. 384-385
    • Ahmed, I.K.1    Teichman, J.C.2
  • 171
    • 33845628387 scopus 로고    scopus 로고
    • Multifocal intraocular lenses in the setting of glaucoma
    • Kumar BV, Phillips RP, Prasad S. Multifocal intraocular lenses in the setting of glaucoma. Curr Opin Ophthalmol 2007; 18:62-66.
    • (2007) Curr Opin Ophthalmol , vol.18 , pp. 62-66
    • Kumar, B.V.1    Phillips, R.P.2    Prasad, S.3
  • 172
    • 0033998391 scopus 로고    scopus 로고
    • Visual outcome with the Array multifocal intraocular lens in patients with concurrent eye disease
    • Kameth GG, Prasad S, Danson A, Phillips RP. Visual outcome with the Array multifocal intraocular lens in patients with concurrent eye disease. J Cataract Refract Surg 2000; 26:576-581.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 576-581
    • Kameth, G.G.1    Prasad, S.2    Danson, A.3    Phillips, R.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.