-
1
-
-
13144282668
-
A systematic overview of the incidence of posterior capsule opacification
-
Schaumberg D.A., Dana M.R., Christen W.G., Glynn R.J. A systematic overview of the incidence of posterior capsule opacification. Ophthalmology. 105:1998;1213-1221
-
(1998)
Ophthalmology
, vol.105
, pp. 1213-1221
-
-
Schaumberg, D.A.1
Dana, M.R.2
Christen, W.G.3
Glynn, R.J.4
-
3
-
-
0032895795
-
Posterior capsule opacification. Part 1: Experimental investigations
-
Nishi O. Posterior capsule opacification. Part 1. experimental investigations J Cataract Refract Surg. 25:1999;106-117
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 106-117
-
-
Nishi, O.1
-
4
-
-
0033497365
-
Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification
-
Ram J., Apple D.J., Peng Q., et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification. Ophthalmology. 106:1999;891-900
-
(1999)
Ophthalmology
, vol.106
, pp. 891-900
-
-
Ram, J.1
Apple, D.J.2
Peng, Q.3
-
5
-
-
0031817140
-
Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens
-
Nishi O., Nishi K., Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers. 29:1998;587-594
-
(1998)
Ophthalmic Surg Lasers
, vol.29
, pp. 587-594
-
-
Nishi, O.1
Nishi, K.2
Sakanishi, K.3
-
6
-
-
0036062180
-
Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses
-
Daynes T., Spencer T.S., Doan K., et al. Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses. J Cataract Refract Surg. 28:2002;1124-1129
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1124-1129
-
-
Daynes, T.1
Spencer, T.S.2
Doan, K.3
-
7
-
-
0036142525
-
Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses
-
Abela-Formanek C., Amon M., Schild G., et al. Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg. 28:2002;50-61
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 50-61
-
-
Abela-Formanek, C.1
Amon, M.2
Schild, G.3
-
8
-
-
0036062059
-
Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
-
Buehl W., Findl O., Menapace R., et al. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 28:2002;1105-1111
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1105-1111
-
-
Buehl, W.1
Findl, O.2
Menapace, R.3
-
9
-
-
0031456846
-
High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery
-
Pande M.V., Ursell P.G., Spalton D.J., et al. High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery. J Cataract Refract Surg. 23:1997;1521-1527
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 1521-1527
-
-
Pande, M.V.1
Ursell, P.G.2
Spalton, D.J.3
-
10
-
-
0036166274
-
Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification
-
Buehl W., Findl O., Menapace R., et al. Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification. J Cataract Refract Surg. 28:2002;265-270
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 265-270
-
-
Buehl, W.1
Findl, O.2
Menapace, R.3
-
11
-
-
0036169815
-
Assessment of anterior capsule opacification: Photographic technique and quantification
-
Sacu S., Findl O., Menapace R., et al. Assessment of anterior capsule opacification. photographic technique and quantification J Cataract Refract Surg. 28:2002;271-275
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 271-275
-
-
Sacu, S.1
Findl, O.2
Menapace, R.3
-
12
-
-
0037257792
-
Comparison of 4 methods for quantifying posterior capsule opacification
-
Findl O., Buehl W., Menapace R., et al. Comparison of 4 methods for quantifying posterior capsule opacification. J Cataract Refract Surg. 29:2003;106-111
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 106-111
-
-
Findl, O.1
Buehl, W.2
Menapace, R.3
-
13
-
-
0034827421
-
Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up
-
Nishi O., Nishi K., Menapace R., Akura J. Capsular bending ring to prevent posterior capsule opacification. 2 year follow-up J Cataract Refract Surg. 27:2001;1359-1365
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1359-1365
-
-
Nishi, O.1
Nishi, K.2
Menapace, R.3
Akura, J.4
-
14
-
-
0032913224
-
Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
-
Nishi O., Nishi K. Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. J Cataract Refract Surg. 25:1999;521-526
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 521-526
-
-
Nishi, O.1
Nishi, K.2
-
15
-
-
0031890039
-
The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
-
Nishi O., Nishi K., Mano C., et al. The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers. 29:1998;119-125
-
(1998)
Ophthalmic Surg Lasers
, vol.29
, pp. 119-125
-
-
Nishi, O.1
Nishi, K.2
Mano, C.3
-
16
-
-
0033772907
-
Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
-
Nishi O., Nishi K., Wickström K. Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg. 26:2000;1543-1549
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1543-1549
-
-
Nishi, O.1
Nishi, K.2
Wickström, K.3
-
17
-
-
0030824089
-
Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule
-
Nagamoto T., Eguchi G. Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule. J Cataract Refract Surg. 23:1997;866-872
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 866-872
-
-
Nagamoto, T.1
Eguchi, G.2
-
18
-
-
0033968119
-
Surgical Prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense
-
Peng Q., Visessook N., Apple D.J., et al. Surgical Prevention of posterior capsule opacification. Part 3. intraocular lens optic barrier effect as a second line of defense J Cataract Refract Surg. 26:2000;198-213
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 198-213
-
-
Peng, Q.1
Visessook, N.2
Apple, D.J.3
-
19
-
-
0037398513
-
Quantification of posterior capsule opacification with round and sharp edge intraocular lenses
-
Auffarth G.U., Golescu A., Becker K.A., Völcker H.E. Quantification of posterior capsule opacification with round and sharp edge intraocular lenses. Ophthalmology. 110:2003;772-780
-
(2003)
Ophthalmology
, vol.110
, pp. 772-780
-
-
Auffarth, G.U.1
Golescu, A.2
Becker, K.A.3
Völcker, H.E.4
-
20
-
-
0034003905
-
Two year results: Sharp versus rounded optic edges on silicone lenses
-
Kruger A.J., Schauersberger J., Abela C., et al. Two year results. sharp versus rounded optic edges on silicone lenses J Cataract Refract Surg. 26:2000;566-570
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 566-570
-
-
Kruger, A.J.1
Schauersberger, J.2
Abela, C.3
-
21
-
-
0034911128
-
Sharp-edged intraocular lens design as a cause of permanent glare
-
Ellis M.F. Sharp-edged intraocular lens design as a cause of permanent glare. J Cataract Refract Surg. 27:2001;1061-1064
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1061-1064
-
-
Ellis, M.F.1
-
22
-
-
0033055918
-
Analysis of edge glare phenomena in intraocular lens edge designs
-
Holladay J.T., Lang A., Portney V. Analysis of edge glare phenomena in intraocular lens edge designs. J Cataract Refract Surg. 25:1999;748-752
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 748-752
-
-
Holladay, J.T.1
Lang, A.2
Portney, V.3
|