메뉴 건너뛰기




Volumn 30, Issue 8, 2004, Pages 1661-1667

Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CATARACT; CATARACT EXTRACTION; CONTROLLED STUDY; HUMAN; IMAGING SYSTEM; INHIBITION KINETICS; LENS IMPLANT; MAJOR CLINICAL STUDY; POSTOPERATIVE CARE; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE;

EID: 4143145399     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2004.02.051     Document Type: Article
Times cited : (51)

References (23)
  • 1
    • 13144282668 scopus 로고    scopus 로고
    • A systematic overview of the incidence of posterior capsule opacification
    • Schaumberg D.A., Dana M.R., Christen W.G., Glynn R.J. A systematic overview of the incidence of posterior capsule opacification. Ophthalmology. 105:1998;1213-1221
    • (1998) Ophthalmology , vol.105 , pp. 1213-1221
    • Schaumberg, D.A.1    Dana, M.R.2    Christen, W.G.3    Glynn, R.J.4
  • 3
    • 0032895795 scopus 로고    scopus 로고
    • Posterior capsule opacification. Part 1: Experimental investigations
    • Nishi O. Posterior capsule opacification. Part 1. experimental investigations J Cataract Refract Surg. 25:1999;106-117
    • (1999) J Cataract Refract Surg , vol.25 , pp. 106-117
    • Nishi, O.1
  • 4
    • 0033497365 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification
    • Ram J., Apple D.J., Peng Q., et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification. Ophthalmology. 106:1999;891-900
    • (1999) Ophthalmology , vol.106 , pp. 891-900
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 5
    • 0031817140 scopus 로고    scopus 로고
    • Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens
    • Nishi O., Nishi K., Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers. 29:1998;587-594
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 587-594
    • Nishi, O.1    Nishi, K.2    Sakanishi, K.3
  • 6
    • 0036062180 scopus 로고    scopus 로고
    • Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses
    • Daynes T., Spencer T.S., Doan K., et al. Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses. J Cataract Refract Surg. 28:2002;1124-1129
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1124-1129
    • Daynes, T.1    Spencer, T.S.2    Doan, K.3
  • 7
    • 0036142525 scopus 로고    scopus 로고
    • Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses
    • Abela-Formanek C., Amon M., Schild G., et al. Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg. 28:2002;50-61
    • (2002) J Cataract Refract Surg , vol.28 , pp. 50-61
    • Abela-Formanek, C.1    Amon, M.2    Schild, G.3
  • 8
    • 0036062059 scopus 로고    scopus 로고
    • Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    • Buehl W., Findl O., Menapace R., et al. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 28:2002;1105-1111
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1105-1111
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 9
    • 0031456846 scopus 로고    scopus 로고
    • High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery
    • Pande M.V., Ursell P.G., Spalton D.J., et al. High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery. J Cataract Refract Surg. 23:1997;1521-1527
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1521-1527
    • Pande, M.V.1    Ursell, P.G.2    Spalton, D.J.3
  • 10
    • 0036166274 scopus 로고    scopus 로고
    • Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification
    • Buehl W., Findl O., Menapace R., et al. Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification. J Cataract Refract Surg. 28:2002;265-270
    • (2002) J Cataract Refract Surg , vol.28 , pp. 265-270
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 11
    • 0036169815 scopus 로고    scopus 로고
    • Assessment of anterior capsule opacification: Photographic technique and quantification
    • Sacu S., Findl O., Menapace R., et al. Assessment of anterior capsule opacification. photographic technique and quantification J Cataract Refract Surg. 28:2002;271-275
    • (2002) J Cataract Refract Surg , vol.28 , pp. 271-275
    • Sacu, S.1    Findl, O.2    Menapace, R.3
  • 12
    • 0037257792 scopus 로고    scopus 로고
    • Comparison of 4 methods for quantifying posterior capsule opacification
    • Findl O., Buehl W., Menapace R., et al. Comparison of 4 methods for quantifying posterior capsule opacification. J Cataract Refract Surg. 29:2003;106-111
    • (2003) J Cataract Refract Surg , vol.29 , pp. 106-111
    • Findl, O.1    Buehl, W.2    Menapace, R.3
  • 13
    • 0034827421 scopus 로고    scopus 로고
    • Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up
    • Nishi O., Nishi K., Menapace R., Akura J. Capsular bending ring to prevent posterior capsule opacification. 2 year follow-up J Cataract Refract Surg. 27:2001;1359-1365
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1359-1365
    • Nishi, O.1    Nishi, K.2    Menapace, R.3    Akura, J.4
  • 14
    • 0032913224 scopus 로고    scopus 로고
    • Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
    • Nishi O., Nishi K. Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. J Cataract Refract Surg. 25:1999;521-526
    • (1999) J Cataract Refract Surg , vol.25 , pp. 521-526
    • Nishi, O.1    Nishi, K.2
  • 15
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • Nishi O., Nishi K., Mano C., et al. The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers. 29:1998;119-125
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3
  • 16
    • 0033772907 scopus 로고    scopus 로고
    • Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
    • Nishi O., Nishi K., Wickström K. Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg. 26:2000;1543-1549
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1543-1549
    • Nishi, O.1    Nishi, K.2    Wickström, K.3
  • 17
    • 0030824089 scopus 로고    scopus 로고
    • Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule
    • Nagamoto T., Eguchi G. Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule. J Cataract Refract Surg. 23:1997;866-872
    • (1997) J Cataract Refract Surg , vol.23 , pp. 866-872
    • Nagamoto, T.1    Eguchi, G.2
  • 18
    • 0033968119 scopus 로고    scopus 로고
    • Surgical Prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense
    • Peng Q., Visessook N., Apple D.J., et al. Surgical Prevention of posterior capsule opacification. Part 3. intraocular lens optic barrier effect as a second line of defense J Cataract Refract Surg. 26:2000;198-213
    • (2000) J Cataract Refract Surg , vol.26 , pp. 198-213
    • Peng, Q.1    Visessook, N.2    Apple, D.J.3
  • 19
    • 0037398513 scopus 로고    scopus 로고
    • Quantification of posterior capsule opacification with round and sharp edge intraocular lenses
    • Auffarth G.U., Golescu A., Becker K.A., Völcker H.E. Quantification of posterior capsule opacification with round and sharp edge intraocular lenses. Ophthalmology. 110:2003;772-780
    • (2003) Ophthalmology , vol.110 , pp. 772-780
    • Auffarth, G.U.1    Golescu, A.2    Becker, K.A.3    Völcker, H.E.4
  • 20
    • 0034003905 scopus 로고    scopus 로고
    • Two year results: Sharp versus rounded optic edges on silicone lenses
    • Kruger A.J., Schauersberger J., Abela C., et al. Two year results. sharp versus rounded optic edges on silicone lenses J Cataract Refract Surg. 26:2000;566-570
    • (2000) J Cataract Refract Surg , vol.26 , pp. 566-570
    • Kruger, A.J.1    Schauersberger, J.2    Abela, C.3
  • 21
    • 0034911128 scopus 로고    scopus 로고
    • Sharp-edged intraocular lens design as a cause of permanent glare
    • Ellis M.F. Sharp-edged intraocular lens design as a cause of permanent glare. J Cataract Refract Surg. 27:2001;1061-1064
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1061-1064
    • Ellis, M.F.1
  • 22
    • 0033055918 scopus 로고    scopus 로고
    • Analysis of edge glare phenomena in intraocular lens edge designs
    • Holladay J.T., Lang A., Portney V. Analysis of edge glare phenomena in intraocular lens edge designs. J Cataract Refract Surg. 25:1999;748-752
    • (1999) J Cataract Refract Surg , vol.25 , pp. 748-752
    • Holladay, J.T.1    Lang, A.2    Portney, V.3
  • 23


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.